• 제목/요약/키워드: Cylindrical chamber

검색결과 159건 처리시간 0.033초

2D-ICP(inductively coupled plasma)에서 정전 탐침 삽입 시의 플라즈마 수치 계산 (Numerical Modeling of Perturbation Effects of Electrostatic Probe into 2D ICP(inductively coupled plasma))

  • 주정훈
    • 한국표면공학회지
    • /
    • 제44권1호
    • /
    • pp.26-31
    • /
    • 2011
  • Numerical modeling is used to investigate the perturbation of a single Langmuir probe (0.2 mm diameter shielded with 6 mm insulator) inserted along the center axis of a cylindrical inductively coupled plasma chamber filled with Ar at 10 mTorr and driven by 13 MHz. The probe was driven by a sine wave. When the probe tip is close to a substrate by 24.5 mm, the probe characteristics was unperturbed. At 10 mm above the substrate, the time averaged electric potential distribution around the tip was severly distorted making a normal probe analysis impossible.

Thermoelastic Behaviors of Fabric Membrane Structures

  • Roh, Jin-Ho;Lee, Han-Geol;Lee, In
    • Advanced Composite Materials
    • /
    • 제17권4호
    • /
    • pp.319-332
    • /
    • 2008
  • The thermoelastic behaviors of an inflatable fabric membrane structure for use in a stratospheric airship envelope are experimentally and numerically investigated. Mechanical tensile properties of the membrane material at room, high, and low temperatures are measured using an $Instron^{(R)}$ universal testing machine and an $Instron^{(R)}$ thermal chamber. To characterize the nonlinear behavior of the inflated membrane structure due to wrinkling, the bending behavior of an inflated cylindrical boom made of a fabric membrane is observed at various pressure levels. Moreover, the envelope of a stratospheric airship is numerically modeled based on the thermoelastic properties of the fabric membrane obtained from experimental data, and the wrinkled deformed shape induced by a thermal load is analyzed.

엔진 흡기계에 쓰이는 다공형 직조관의 음향특성 측정 및 성능예측 (Measurement of Acoustic Properties and Prediction of Acoustic Performance of Porous Woven Hoses for Engine Intake Systems)

  • 박철민;이정권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.182-186
    • /
    • 2000
  • The porous woven hose is recently considered as an effective element of automotive intake systems. In order to predict the acoustic performance of an intake system with a porous woven hose, the information on the acoustic wall impedance is required. In this article, a measurement technique that is valid over the low frequency range and without mean flow condition is presented. The measurement is performed in a cylindrical chamber with a concentric layout of the sample and the resistance is estimated from measured reactance and transmission loss data. It is observed that the measured transmission loss for a porous woven hose with an arbitrary length agrees well with the predicted one that uses the estimated impedance for a small sample length.

  • PDF

이온 전리함 및 TLD 법을 이용한 Multi-Detector Computed Tomography의 흡수선량 및 체표면 선량 평가 (Evaluation of Absorbed Dose and Skin Dose with MDCT Using Ionization Chamber and TLD)

  • 전경수;오영기;백종근;김옥배;김진희;최태진;정동혁;김정기
    • 한국의학물리학회지:의학물리
    • /
    • 제24권1호
    • /
    • pp.35-40
    • /
    • 2013
  • 최근 세기조절 방사선치료(Intensity Modulated Radiation Therapy, IMRT)와 같은 고 정밀 방사선 치료의 발전과 함께 두 경부 환자의 진단 및 치료 계획 그리고 추적관찰(follw-up)을 목적으로 한 CT 촬영 횟수가 크게 증가하고 있다. 이러한 CT 촬영의 증가와 MDCT와 같은 CT의 발전과 한 검사로 받는 피폭 선량이 상대적으로 다른 검사에 비하여 월등히 크기 때문에 환자 피폭 선량의 정확한 선량 평가가 요구된다. 본 연구에서는 두 경부용 물팬텀(cylindrical water phantom)을 자체 제작하여, 연필형 이온 전리함 및 30 cc 이온 전리함 그리고 LiF:Mg,Cu,P TL 분말을 사용한 열형광 선량 측정법(Thermoluminescent Dosimetry, TLD)을 이용하여 Multi Detector Computed Tomography, MDCT의 흡수 선량 및 체표면 선량을 비교 평가하였다. MDCT의 슬라이스 폭의 일정한 선량 균일성을 확인하기 위하여 콜리메이션 2 mm 단일 빔의 프로필을 1 mm 간격으로 80 mm 측정한 결과 빔의 폭이 12 mm이고 선량 분포는 80~100%로 빔의 출력은 +Y 방향으로 높게 나타났다. 물팬텀의 중심부에서 연필형 이온 전리함 및 30 cc 이온 전리함과 TLD의 흡수 선량은 각각 31.83 mGy, 33.58 mGy, 32.73 mGy로 TLD의 흡수 선량은 이온전리함으로 구한 흡수선량과 오차범위 내에서 일치하고 있음을 알 수 있었다. 체표면 10 mm 깊이에서의 TLD 선량은 33.92 mGy로 중심부보다 약 3.5% 높게 평가 되었다. 이러한 흡수선량은 두 경부 환자가 최초 진단을 위한 CT 촬영으로부터 치료계획 및 추적관찰을 목적으로 한 CT촬영까지 4회의 CT촬영을 할 경우, 이로 인한 피폭 선량이 약 14 cGy임을 알 수 있었다. 따라서 방사선치료를 위한 CT 촬영으로 인한 환자의 피폭이 적지않음을 확인하였고 가능한 한 피폭을 줄이려는 노력을 기울여야 할 것이다.

형상계수를 이용한 사질토 지반에 타설된 테이퍼말뚝의 지지력 산정 (Calculation of Bearing Capacity of Tapered Drilled Shafts in Cohesionless Soils Using Shape Factor)

  • 백규호;이준환
    • 한국지반공학회논문집
    • /
    • 제24권12호
    • /
    • pp.13-22
    • /
    • 2008
  • 지반조건과 말뚝의 테이퍼각도가 태야퍼말뚝의 지지력에 미치는 영향을 조사하기 위해서 원통형말뚝과 테이퍼각도가 다른 두 개의 메이퍼딸뚝을 이용해서 모형말뚝재하시험을 수행하였다. 시험결과에 띠르면 지반의 평균응력과 상대밀도가 커지면 테이퍼말뚝의 단위 선단지지력은 증가하였고, 말뚝의 테이퍼각도가 커집에 따라 느슨한 지반에서는 단위 선단지지력은 증가하였으나 조밀한 지반에서는 단위 선단지지력이 반대로 감소하였다. 그리고 테이퍼말뚝의 단위 주면마찰력은 지반의 수평 및 연직응력과 상대밀도, 말뚝의 테이퍼각도가 커짐에 따라 증가하는 것으로 나타났다. 한편, 모형말뚝재하시험의 결과에 근거해서 형상계수를 표함한 테이퍼말뚝의 지지력 산정식을 제안하였고, 이 제안식에서는 지반조건과 테이퍼각도가 말뚝의 지지력에 미치는 영향이 고려되였다. 제안한 지지력 산정식에 대한 정확도를 검증하기 위해서 점토질 모래지반에 설치된 중간규모의 원통형말뚝과 테이퍼말뚝에 대한 현장재하시험이 실시되었고, 이때 측정된 지지력이 제안식에서 얻은 예측치와 비교되었다. 그 결과 제안된 지지력 산정식은 테이퍼말뚝의 지지력을 비교적 정확하게 예측하는 것으로 나타났다.

Study of Radio Frequency Thawing for Cylindrical Pork Sirloin

  • Kim, Jinse;Park, Jong Woo;Park, Seokho;Choi, Dong Soo;Choi, Seung Ryul;Kim, Yong Hoon;Lee, Soo Jang;Park, Chun Wan;Han, Gui Jeung;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • 제41권2호
    • /
    • pp.108-115
    • /
    • 2016
  • Purpose: Radio frequency (RF) heating is a promising thawing method, but it frequently causes undesirable problems such as non-uniform heating. This can occur because of the food shape, component distribution, and initial temperature differences between food parts. In this study, RF heating was applied to the thawing of cylindrically shaped pork sirloin by changing the shape of electrodes and the surrounding temperature. Methods: Curved electrodes were utilized to increase the thawing uniformity of cylindrically shaped frozen meat. Pork sirloin in the shape of a half-circle column was frozen in a deep freezer at $-70^{\circ}C$ and then thawed by RF heating with flat and curved electrodes. In order to prevent fast defrosting of the food surface by heat transfer from air to the food, the temperature of the thawing chamber was varied by -5, -10, and $-20^{\circ}C$. The temperature values of the frozen pork sirloin during RF thawing were measured using fiber-optic thermo sensors. Results: After multiple applications of curved electrodes resembling the food shape, and a cooled chamber at $-20^{\circ}C$ the half-cylindrically shaped meat was thawed without surface burning, and the temperature values of each point were similarly increased. However, with the parallel electrode, the frozen meat was partially burned by RF heating and the temperature values of center were overheated. The uniform heating rate and heat transfer prevention from air to the food were crucial factors for RF thawing. In this study, these crucial factors were accomplished by using a curved electrode and lowering the chamber temperature. Conclusions: The curved shape of the electrode and the equipotential surface calculated from the modeling of the parallel capacitor showed the effect of uniform heating of cylindrically shaped frozen food. Moreover, the low chamber temperature was effective on the prevention of the surface burning during RF thawing.

토모테라피 치료 시 MVCT Image의 Slice Thickness 차이에 따른 선량 비교 (Extra Dose Measurement of Differential Slice Thickness of MVCT Image with Helical Tomotherapy)

  • 이병구;강수만
    • 한국방사선학회논문지
    • /
    • 제7권2호
    • /
    • pp.145-149
    • /
    • 2013
  • 의료용 선형가속기 (linear accelerator)와 나선형 컴퓨터 단층 촬영 장치 (helical computed tomography scanner)의 결합 장치인 토모테라피는 세기 변조 방사선 치료 (intensity modulated radiation therapy(IMRT))의 큰 혁신을 이끌었다. 토모테라피 치료 과정에서, Megavoltage computed tomography (MVCT) 영상획득은 치료 환자의 정확한 자세 정렬을 위해 치료 전 또는 후에 이용된다. 그러나 이는 환자의 총 선량을 증가시키는 결과를 만들며, 본 연구는 이처럼 MVCT 영상 획득 시 증가되는 선량을 Cylindrical "Cheese" Phantom을 이용하여 측정, 비교하였다. 각각의 pitch 별로 (1, 2, 3 mm) 동일한 개수의 slice (10 slice), 그리고 동일한 length (약 9 cm)를 scanning하여, 이때의 선량 (MVCT Scanning Dose)을 A1SL ion chamber를 이용하여 측정하였다. 측정 결과 동일한 Slice 개수 (각각의 pitch 당 10개)일 때, MVCT scanning dose의 평균값은 각각 (pitch 1, 2, 3mm) 2.24 cGy, 1.02 cGy, 0.81 cGy가 측정되었다. 동일한 length에서 MVCT scanning dose의 평균값은 각각 (pitch 1, 2, 3mm) 2.47 cGy, 1.28 cGy, 0.88 cGy가 측정되었다. 이는 할당된 pitch와 scanning length가 MVCT scanning dose에 큰 영향을 미치는 가장 중요한 매개 변수임을 말하며, pitch는 MVCT scanning dose와 역비례 관계를 나타냈다. 때문에 적절한 pitch와 scanning length의 선택으로 치료 선량 외의 추가 선량을 최소로 줄여야 하겠다.

전극 구조에 관한 2차원 RF 플라즈마의 모델링 (Modeling of Two-dimensional Self-consistent RF Plasmas on Discharge Chamber Structures)

  • 소순열;임장섭;김철운
    • 조명전기설비학회논문지
    • /
    • 제19권4호
    • /
    • pp.1-8
    • /
    • 2005
  • 본 연구에서는 2차원적 유체 모델을 통하여 보다 실질적인 플라즈마를 이해하고자 하였으며, 기하학적인 방전전극 구조를 반영하도록 전극단에서 챔버 외벽의 거리를 변화시키면서 플라즈마의 특성을 정량적으로 비교 분석하고자 하였다. 방전 챔버의 구조로서, 전극의 반경과 방전 챔버의 높이는 일정하게 유지하면서 방전 챔버의 넓이를 변화시킴에 따라 형성되는 플라즈마의 특성을 분석하였다. 그 결과, 전극단과 챔버 외벽의 거리가 짧을수록 그 영역에서 전계가 강하게 형성되어, 외벽을 향하는 각 입자들의 움직임도 매우 활발하다는 것을 알 수 있었다. 또한, 전각단과 외벽과의 거리가 짧을수록 전극 면상에서 형성되는 입자들의 수밀도와 유속의 변화가 일정하게 형성되는 것을 알 수 있었다. 이러한 결과는 웨이퍼의 대구경화에 따른 플라즈마의 균일성을 고려할 경우에 매우 효과적일 것으로 고려되어 진다.

원통형 및 테이퍼말뚝의 하중-침하특성 및 CPT지지력상관계수 (Evaluation of CPT-based Pile Load Capacity Factors with Cylindrical and Taper Pile)

  • 이준환;백규호;김대홍;김민기;황성욱
    • 한국지반공학회논문집
    • /
    • 제23권4호
    • /
    • pp.59-68
    • /
    • 2007
  • 본 논문에서는 토조에 실시된 모형말뚝 재하실험과 콘관입실험을 통하여, 말뚝형태별 지지력 특성분석과 CPT지지력 상관계수를 평가하였다. 고려된 말뚝의 형태는 일반적인 현장타설말뚝에 적용되는 원통형 말뚝과 테이퍼형 말뚝이 고려되었다. 본 연구는 궁극적으로 강관주 송전탑의 기초구조물 형식개발과 설계기준 수립을 목표로 하고 있으며, 이를 위해 기초형식별 거동과 지반상태의 영향 등을 중점적으로 살펴보았다. 말뚝 토조실험을 통해 나타난 결과에 의하면, 원통형 및 테이퍼형 말뚝의 전체지지력의 차이는 크지 않았으나, 개별 지지력요소의 거동은 말뚝형태별로 상이한 것으로 나타났다. 토조실험결과와 동일한 지반조건에 대해 수행된 CPT결과를 통해 말뚝지지력과 콘지지력의 관계를 나타내는 CPT지지력 상관계수의 변화추이를 도출하였다. CPT상관계수는 원통형 및 테이퍼형 말뚝형태를 비교함으로써 나타내었으며, 선단지지력과 주면마찰력의 요소별 변화추이를 제안하였다.

교정정수 변화에 의한 원통형이온함의 안정성 평가 (Evaluation of the Long-Term Stability for the Cylindrical Ionization Chambers)

  • 라정은;홍주영;김귀야;임천일;정희교;신동오;서태석
    • Radiation Oncology Journal
    • /
    • 제24권2호
    • /
    • pp.138-143
    • /
    • 2006
  • 목적: 식품의약품안전청(Korea Food Drug Administration, KFDA)의 도움을 받아 1998년부터 2004년까지 장기간에 걸친 교정정수의 분석을 통해 원통형이온함의 모델별 안정성을 확인하고자 한다. 대상 및 방법: 치료방사선기관에서 교정을 의뢰한 이온함 중 Farmer형의 원통형이온함만을 대상으로 하였으며 모델은 PTW사의 30001 (30006), 30013, 30002, 30004, 23333과 Capintec사의 PR06C, NE사의 2571, Exradin사의 A12 그리고 Wellhofer사의 FC65G (IC70) 등 총 9개 종류의 이온함에 대해 에어커마 교정정수 및 물흡수선량 교정정수를 분석하였으며 에어커마 교정정수를 이용하여 계산한 물흡수선량 교정정수(cal. $N_{D,W}$)와 실제측정에 의해 결정된 물흡수선량 교정정수(mea. $N_{D,W}$)를 상호 비교하였다. 결과: 교정정수 변화를 분석해 본 결과, PTW사의 30013 (30006), Wellhofer사의 FC65G (IC70) 그리고 NE사의 2571 이온함의 경우 측정 표준편차 0.2% 이내에서 잘 일치하여 다른 모델의 이온함에 비해 안정된 값을 가지는 것으로 나타났으며 계산에 의한 물흡수선량 교정정수와 실제 측정에 의해 결정된 물흡수선량 교정정수를 비교 분석한 결과는 모든 이온함에서 측정에 의한 물흡수선량 교정정수가 약 1.0% 큰 것으로 나타났다. 결론: 본 연구에서는 원통형이온함의 교정정수 값들에 대하여 장기간의 안정성 평가를 토대로 임상에서 요구되는 이온함의 선택 기준을 제시함으로써 표준체계에 따른 이온함의 선택 뫼 선량측정의 정확성을 향상시킬 것으로 기대한다.