• 제목/요약/키워드: Cyclic surfaces

검색결과 107건 처리시간 0.025초

Effects of air-abrasion pressure on the resin bond strength to zirconia: a combined cyclic loading and thermocycling aging study

  • Al-Shehri, Eman Z.;Al-Zain, Afnan O.;Sabrah, Alaa H.;Al-Angari, Sarah S.;Dehailan, Laila Al;Eckert, George J.;Ozcan, Mutlu;Platt, Jeffrey A.;Bottino, Marco C.
    • Restorative Dentistry and Endodontics
    • /
    • 제42권3호
    • /
    • pp.206-215
    • /
    • 2017
  • Objectives: To determine the combined effect of fatigue cyclic loading and thermocycling (CLTC) on the shear bond strength (SBS) of a resin cement to zirconia surfaces that were previously air-abraded with aluminum oxide ($Al_2O_3$) particles at different pressures. Materials and Methods: Seventy-two cuboid zirconia specimens were prepared and randomly assigned to 3 groups according to the air-abrasion pressures (1, 2, and 2.8 bar), and each group was further divided into 2 groups depending on aging parameters (n = 12). Panavia F 2.0 was placed on pre-conditioned zirconia surfaces, and SBS testing was performed either after 24 hours or 10,000 fatigue cycles (cyclic loading) and 5,000 thermocycles. Non-contact profilometry was used to measure surface roughness. Failure modes were evaluated under optical and scanning electron microscopy. The data were analyzed using 2-way analysis of variance and ${\chi}^2$ tests (${\alpha}=0.05$). Results: The 2.8 bar group showed significantly higher surface roughness compared to the 1 bar group (p < 0.05). The interaction between pressure and time/cycling was not significant on SBS, and pressure did not have a significant effect either. SBS was significantly higher (p = 0.006) for 24 hours storage compared to CLTC. The 2 bar-CLTC group presented significantly higher percentage of pre-test failure during fatigue compared to the other groups. Mixed-failure mode was more frequent than adhesive failure. Conclusions: CLTC significantly decreased the SBS values regardless of the air-abrasion pressure used.

Fabrication of Carbon Microcapsules Containing Silicon Nanoparticles-Carbon Nanotubes Nanocomposite for Anode in Lithium Ion Battery

  • Bae, Joon-Won;Park, Jong-Nam
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권9호
    • /
    • pp.3025-3032
    • /
    • 2012
  • Carbon microcapsules containing silicon nanoparticles (Si NPs)-carbon nanotubes (CNTs) nanocomposite (Si-CNT@C) have been fabricated by a two step polymerization method. Silicon nanoparticles-carbon nanotubes (Si-CNT) nanohybrids were prepared with a wet-type beadsmill method. A polymer, which is easily removable by a thermal treatment (intermediate polymer) was polymerized on the outer surfaces of Si-CNT nanocomposites. Subsequently, another polymer, which can be carbonized by thermal heating (carbon precursor polymer) was incorporated onto the surfaces of pre-existing polymer layer. In this way, polymer precursor spheres containing Si-CNT nanohybrids were produced using a two step polymerization. The intermediate polymer must disappear during carbonization resulting in the formation of an internal free space. The carbon precursor polymer should transform to carbon shell to encapsulate remaining Si-CNT nanocomposites. Therefore, hollow carbon microcapsules containing Si-CNT nanocomposites could be obtained (Si-CNT@C). The successful fabrication was confirmed by scanning electron microscopy (SEM) and X-ray diffraction (XRD). These final materials were employed for anode performance improvement in lithium ion battery. The cyclic performances of these Si-CNT@C microcapsules were measured with a lithium battery half cell tests.

수종 임플랜트 지대주나사의 반복하중 후 나사풀림에 관한 연구 (A STUDY OF SCREW LOOSENING AFTER DYNAMIC CONTINOUS FATIGUE TEST OF SEVERAL ABUTMENT SCREW)

  • 김진만;한중석;이선형;양재호;이재봉;김영수
    • 대한치과보철학회지
    • /
    • 제41권4호
    • /
    • pp.519-531
    • /
    • 2003
  • Statement of problem : Chronic implant screw loosening remains a problem in restorative practices. Some implant manufactureres have introduced abutment screws with treated material, surfaces and macrostructures in an effort to reduce potential loosening. Purpose : This study evaluated the materials and loading cycles on detorque value after dynamic continous fatigue test in the sinulated conditions of posterior single restoration. Material and method : Fourteen of each of the following abutment screws - titanium alloy, gold alloy, gold-tite, and titanium alloy modified - were used in test. SEM is used to verify macrostructures of each screws. $ZrO_2/Al_2O_3$ composite abutment was tightened on $4{\times}10.0mm$ titanium external implant at 30 Ncm. Cyclic loading machine delivered dynamic loading forces between 20 and 320N for 100,000, 200,000, 300,000, 500,000, and 1,000,000 cycles at frequencies 14Hz. Torque and detorque value after loading was measured. Results : All measued screws had different screw length and thread form. Titanium modified screw had greater detorque value than others before and after cyclic loadings(p<0.05). All abutment screws had no significant change in mean percentage of detorque value after loading to initial value after less than 500.000 cyclic loadings, but significant lower value after 1,000,000 cycles(p<0.05). Conclusion : Within limintations of this study all abutment screws may be loosend after about 1 year use. Annual check-up is nessasary to prevent screw loosening.

다양한 기공 크기 및 분포를 갖는 양극 탄소의 전극 특성 (Electrode properties of various carbon anodes containing different sizes and distributions of pores)

  • 안홍주;오한준;김인기;김세경;임창성;지충수;이재봉;박광규;고영신
    • 한국결정성장학회지
    • /
    • 제12권1호
    • /
    • pp.42-49
    • /
    • 2002
  • 기공 크기와 분포가 다른 세 종류의 전해용 탄소전극 즉, YBD-like grade carbon, YBD grade carbon, P2X grade carbon 전극의 전극 특성과 불소 전해특성을 비교하였다. 탄소전극의 특성 조사는 물리적 특성 및 1 mM의 $[[Fe(CN)_6]^\;{3-}/Fe(CN)_6$]$^{4-}$가 첨가된 0.5M $K_2SO_4$ 용액에서의 변전위 전류전압곡선과 한계확산전류밀도를 통하여 전기화학적 거동을 평가하고. 불소 전해특성은 $85^{\circ}C$의 KF.2HF용응염의 전기분해 시 임계전류밀도로 비교하였다. 이 결과 변.전위 전류전압곡선과 한계전류밀도에서는 적절한 기공을 함유한 P2X grade carbon 전극이, 불소 전해특성에서는 200~300$\mu$m의 기공 크기를 갖는 YBD-like grade carbon 전극이 우수한 전극 특성을 보였다. 이러한 전극 특성의 차이는 탄소전극 표면에 용도에 적합한 크기의 기공이 적절하게 분포되어 있음에 기인하였다.

API 2W Gr. 50 강재 용접부의 피로균열전파거동의 거시적 및 미시적 관찰 (Marco and Microscopic Observations of Fatigue Crack Growth Behavior in API 2W Gr. 50 Steel Joints)

  • 손혜정;김선진
    • 한국해양공학회지
    • /
    • 제26권5호
    • /
    • pp.73-80
    • /
    • 2012
  • It is well known that a considerable amount of scatter is shown in experimental results relating to fatigue crack growth even under identical and constant amplitude cyclic loading conditions. Moreover, flux cored arc welding (FCAW) is a common method used to join thick plates such as the structural members of large scale offshore structures and very large container ships. The objective of this study was to investigate the macro- and microscopic observations of the fatigue crack growth (FCG) behavior of the FCAWed API 2W Gr. 50 steel joints typically applied for offshore structures. In order to clearly understand the randomness of the fatigue crack growth behavior in the materials of three different zones, the weld metal (WM), heat affected zone (HAZ), and base metal (BM), experimental fatigue crack growth tests for each of five specimens were performed on ASTM standard compact tension (CT) specimens under constant amplitude cyclic loading. Special focus was placed on the fatigued fracture surfaces. As a result, a different behavior was observed at the macro-level, depending on the type of material property: BM, HAZ, or WM. The variability in the fatigue crack growth rate for WM was higher than that of BM and HAZ.

전동식 니켈 티타늄 파일의 표면 결함 및 단면 형태가 반복응력 하에서 피로 파절에 미치는 영향 (EFFECT OF SURFACE DEFECTS AND CROSS-SECTIONAL CONFIGURATION ON THE FATIGUE FRACTURE OF NITI ROTARY FILES UNDER CYCLIC LOADING)

  • 신유미;김의성;김광만;금기연
    • Restorative Dentistry and Endodontics
    • /
    • 제29권3호
    • /
    • pp.267-272
    • /
    • 2004
  • The purpose of this in vitro study was to evaluate the effect of surface defects and cross-sectional configuration of NiTi rotary files on the fatigue life under cyclic loading. Three NiTi rotary files ($K3^{TM},{\;}ProFile^{\circledR},{\;}and{\;}HERO{\;}642^{\circledR}$) with #30/.04 taper were evaluated. Each rotary file was divided into 2 subgroups : control (no surface defects) and experimental group (artificial surface defects), A total of six groups of each 10 were tested. The NiTi rotary files were rotated at 300rpm using the apparatus which simulated curved canal (40 degree of curvature) until they fracture. The number of cycles to fracture was calculated and the fractured surfaces were observed with a scanning electron microscope. The data were analyzed statistically. The results showed that experimental groups with surface defects had lower number of cycles to fracture than control group but there was only a statistical significance between control and experimental group in the $K3^{TM}$ (p<0.05), There was no strong correlation between the cross-sectional configuration area and fracture resistance under experimental conditions. Several of fractured files demonstrated characteristic patterns of brittle fracture consistent with the propagation of pre-existing cracks. This data indicate that surface defects of NiTi rotary files may significantly decrease fatigue life and it may be one possible factor for early fracture of NiTi rotary files in clinical practice.

쇼트피닝 처리를 한 베어링강의 고사이클 피로수명 및 파괴거동 (High Cyclic Fatigue Life and Fracture Behaviors of Shot-Peened Bearing Steel)

  • 윤상재;최낙삼
    • 대한기계학회논문집A
    • /
    • 제35권9호
    • /
    • pp.1119-1129
    • /
    • 2011
  • 쇼트피닝(shot-peening) 처리를 한 베어링강의 고사이클 피로거동을 연구하였다. 열처리한 베어링강(JISSUJ2) 시험편과 열처리 후 쇼트피닝 표면가공을 추가한 시험편을 사용해 회전굽힘피로시험을 수행하고 파단 된 시험편의 파면을 분석하였다. 시험편의 피로파괴는 표면 결함에서 비롯된 표면 파괴와, 내부의 비금속개 재물에서 비롯된 내부형 파괴의 두 종류로 발생하였다. 내부 파괴의 경우 비금속 개재물 주변에 어안(fisheye) 모양의 파괴양식이 관찰되었다. 개재물은 표면으로부터의 깊이와 형상에 따라 피로 수명에 큰 영향을 주었다. 쇼트피닝 가공을 한 베어링강은 저사이클 하중영역 및 고사이클 하중영역에서 모두 피로수명이 향상되었으며, 하중이 작아질수록 피로수명의 개선은 더욱 커졌다. 또한 2 모수 와이블(Weibull) 분포를 이용하여 베어링강의 확률-응력-수명 (P-S-N) 곡선을 구하여 신뢰도 높은 피로수명 예측을 하였다.

Evaluation on Interaction Surface of Plastic Resistance for Exposed-type Steel Column Bases under Biaxial Bending

  • Choi Jae-hyouk;Ohi Kenichi
    • Journal of Mechanical Science and Technology
    • /
    • 제19권3호
    • /
    • pp.826-835
    • /
    • 2005
  • Exposed-type steel column bases are used widely in low-rise building construction. Numerous researchers have examined methods to identify their stiffness and strength, but those studies have heretofore been restricted to in-plane behaviors. This paper presents an experimental investigation of inelastic behaviors of square hollow section (SHS) steel column bases under biaxial bending. Two types of failure modes are considered : anchor bolt yielding and base plate yielding. Different pinching effects and interaction surfaces for biaxial bending are observed for these two modes during bi-directional quasi-static cyclic loading tests. Differences are elucidated using limit analyses based on a simple analytical model.

Comparison of Metal Cleaning Effect on Pt Particles Supported on Carbon and Pt Black Observed by NMR, CV, and TEM

  • Han, Kee-Sung;Han, Oc-Hee
    • 한국자기공명학회논문지
    • /
    • 제6권1호
    • /
    • pp.38-44
    • /
    • 2002
  • 60% Pt on Vulcan XC-72 with similar Pt sizes to fuel cell grade Pt black was investigated by $\^$13/C nuclear magnetic resonance spectroscopy (NMR), cyclic voltammery (CV), transmission electron microscopy (TEM). Experiments were carried out on electrochemically cleaned samples as well as as-received. The TEM and CV results showed that the average particle sizes were changed by cleaning. However, the chemical shift ($\delta$$\_$G/) of $\^$13/C of $\^$13/CO absorbed on Pt surfaces did not show any appreciable variation with particle size change as did in Pt black. These results indicate that a combination of different analytic techniques is essential to understand the properties of the metal particle catalysts and that the presence of carbon black support strongly influences the NMR data, probably through metal-support interaction.

  • PDF

Doping된 Si 반도체 세계에서 pH 효과 (pH Effects at Doped Si Semiconductor Interfaces)

  • 천장호;라극환
    • 대한전자공학회논문지
    • /
    • 제27권12호
    • /
    • pp.1859-1864
    • /
    • 1990
  • The effect of H+ and OH- ion concentrations at doped Si semiconductor/pH buffer solution interfaces were investigated in terms of cyclic current-voltage characteristics. The effects of space charge on oppositely doped Si semiconductors, i.e., p-and n-Si semiconductors, can be effectively applied to study the pH effects and the slow surface states at the interfaces. The adsorptions of H+ and OH- inons on the doped Si semiconductor surfaces are physical adsorption rather than chemical adsorption. Adsorptive processes and charging effects of the slow surface states can be explained as the potential barrier variations and the related current-voltage characteristics at the interfaces. Under forward bias, the charged slow surface states on the p-and n-si semiconductor surface are donor and acceptor slow surface states, respectively. The effects of minority carriers on the slow surface states can be neglected at the doped Si semiconductor interfaces.

  • PDF