• Title/Summary/Keyword: Cycle by Cycle Variation

Search Result 553, Processing Time 0.023 seconds

A Study on Improvement of High Resolution Regional NWP by Applying Ocean Mixed Layer Model (해양혼합층 모델 적용을 통한 고해상도 지역예측모델 성능개선에 대한 연구)

  • Min, Jae-Sik;Jee, Joon-Bum;Jang, Min;Park, Jeong-Gyun
    • Atmosphere
    • /
    • v.27 no.3
    • /
    • pp.317-329
    • /
    • 2017
  • Ocean mixed layer (OML) depth affects diurnal cycle of sea surface temperature (SST) induced by change of solar radiation absorption and heat budget in ocean. The diurnal SST variation can lead to convection over the ocean, which can impact on localized precipitation both over coastal and inland. In this study, we investigate the OML characteristics affecting the diurnal cycle of SST for the Korean Peninsula and surrounding areas. To analyze OML characteristics, HYCOM oceanic mixed layer depth (MLD) and wind field at 10 m from ERA-interim during 2008~2016 are used. In the winter, MLD is deeply formed when the strong wind field is located on perpendicular to continental slope over deep seafloor areas. Besides, cooling SST-induced vertical mixing in OML is reinforced by dry cold air originated from Siberia. The OML in summer is shallowly distributed about 20 m. In order to estimate the impact of OML model in high resolution NWP model, four experimental simulations are performed. At this time, the prognostic scheme of skin SST is applied in NWP to simulate diurnal SST. The simulation results show that CNTL (off-OML) overestimates diurnal cycle of SST, while EXPs (on-OML) indicate similar results to observations. The prediction performance for precipitation of EXPs shows improvement compared with CNTL over coastal as well as inland. This results suggest that the application of the OML model in summer season can contribute to improving the prediction for performance of SST and precipitation over coastal area and inland.

Data Archive Project of 44-year Full Disk CaII K Images at Kyoto University

  • Kitai, Reizaburo;Uenoi, Satoru;Asai, Ayumi;Isobe, Hiroaki;Hayashi, Hiroo
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.90.2-90.2
    • /
    • 2011
  • At Kyoto University, a continuous solar full-disk observation in CaII K line had been done during 44 years of 1926 - 1969. The observation was done with a Askania spectroheliograph on daily base. The images were taken on photographic plates. We started a project to archive these image data into a digital database which will be open to the public for scientific researches. One of the scientific usage of the database is to study the long term variation of the solar chromospheres. Since the area of CaII K plage area is a measure of solar chromospheric heating, we can do comparative study of the sunspot cycle and the chromospheric heating cycle of the sun. Another interesting field of scientific utilization of the database is the long term variation of the heating of terrestrial upper atmosphere. As was shown by Yokoyama, Masuda and Sato (2005), the area of the CaII K plage is a good proxy measure of solar EUV irradiation onto the upper atmosphere of the earth. Thus the completion of our database will serve to supply a basic and long-span data for upper atmospheric heating issues by the cooperative study with the Inter-university Upper atmosphere Global Observation NETwork (IUGONET) developed in Japan.

  • PDF

An Experimental Study on the Performance of Inverter Heat Pump with a Variation of Frequency and Capillary Size

  • Choi, Jong-Min;Kim, Yong-Chan;Kim, Jong-Yup
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.27-35
    • /
    • 1998
  • An experimental study was performed to investigate the optimum cycle of an inverter heat pump as a function of frequency. The performance of the inverter heat pump with the rated cooling capacity of 4,141 W(3,550kcal/h) was measured with a variation of frequency, indoor and outdoor temperature, and length of capillary tube in the psychrometric test room. As a base case, the inverter heat pump with the standard capillary length of l,000mm(optimum size for the frequency of 60Hz) and ASHRAE Test condition "A" was tested by varying frequency from 30Hz to 80Hz. Then, the optimum cycles were investigated by varying the length of capillary tube at each frequency level of 30, 60 and 80Hz. Based on the experimental data, the change of system characteristics between the optimum and the base case were analyzed for each selected frequency level. Generally, for low frequency level(30Hz), the longer length of the capillary tube compared with the standard size showed the higher energy efficiency ratio(EER), while for high frequency level(80Hz) the shorter length of the capillary tube showed the higher EER.

  • PDF

Investigation of Cyclic Variations of IMEP Under Idling Operation in Spark Ignition Engines

  • Han, Sung-Bin
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.81-87
    • /
    • 2001
  • Cyclic variability limits the range of operating conditions of spark ignition engines, especially under lean and highly diluted operation conditions. The cyclic combustion variations can be characterized by pressure parameters, combustion related parameters, and flame-front related parameters. The coefficient of variation (COV) in indicated mean effective pressure (IMEP) defines the cyclic variability in indicated work per cycle.

  • PDF

Estimation of the Blood Pressure Using Point Variation Aspect of Dicrotic Notch on Pulsating Waveform at Each Cardiac Periods (주기별 맥동파형의 절흔점 위치변화 특성을 이용한 혈압 추정)

  • Baik, Seongwan;Park, Sungmin;Shon, Jungman;Park, Geunchul;Lee, Sanghoon;Jang, Wooyoung;Jeon, Ahyoung;Jeon, Gyerok
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.136-143
    • /
    • 2013
  • In the study, novel blood pressure estimation method was proposed to improve the accuracy of oscillometric method. The proposed algorithm estimated the blood pressure by comparing and analyzing the point variation aspect of dicrotic notch on pulsating waveform during each cardiac cycle. The waveforms of each cardiac cycle were extracted by maximum points. The extracted pulsating waveforms were applied by re-sampling, end-matching, and normalization. The systolic and diastolic blood pressures were estimated by point variation aspect of dicrotic notch. The blood pressures, which were estimated from proposed algorithm, were compared and analyzed by blood pressures from oscillometric methods and auscultation. The systolic blood pressure from oscillometric methods were +0.88 mmHg more than proposed algorithm, and 1.875 less than the diastolic blood pressures from proposed algorithm. The systolic and diastolic blood pressures from auscultation were 2.89 mmHg and 3.44 mmHg less than the blood pressures from proposed algorithm. As the errors between blood pressures from proposed algorithm, oscillometric method and auscultation were less than 5 mmHg, the proposed algorithm was effective.

Evaluation of monthly environmental loads from municipal wastewater treatment plants operation using life cycle assessment

  • Piao, Wenhua;Kim, Ye-jin
    • Environmental Engineering Research
    • /
    • v.21 no.3
    • /
    • pp.284-290
    • /
    • 2016
  • Life cycle assessment (LCA) methodology can be used to assess impacts on the environment that might be generated during treatment of wastewater and sludge treatment. In this work, LCA methodology was suggested to evaluate monthly environmental impact of wastewater treatment plants (WWTPs). Two field scale WWTPs, A2/O process and conventional activated sludge process (CAS), were selected as target plants and the operational data were collected from those plants. As the function units, the unit volume of treated wastewater of $1m^3$ and 1 kg T-N eq. removed were selected. The environmental effect of target WWTPs operation were assessed as impact categories such as global warming potential, eutrophication potential, and so on. From monthly profiles of each index, it was shown that the environmental impact of WWTPs has seasonal patterns influenced by the influent flow rate variation causing higher impacts in winter than summer. This is due to the fact that there were no significant increase in the electricity consumption and chemical usage during the summer while the treated volume of wastewater was increased.

Cycle Analysis of Air-Cooled Double-Effect Absorption Cooling System Using H2O/LiBr+HO(CH2)3OH (H2O/LiBr+HO(CH2)3OH계 공냉형 이중효용 흡수식 냉방시스템의 사이클 해석)

  • Kwon, Oh-Kyung;Moon, Choon-Geun;Yoon, Jung-In
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.2
    • /
    • pp.272-280
    • /
    • 1999
  • A cycle analysis was achieved to predict the characteristics by comprehensive modeling and simulation of an air-cooled, double-effect absorption system using a new $H_2O/LiBr+HO(CH_2)_3OH$ solution. The simulation results showed that the new working fluid may provide the crystallization limit 8% higher than the conventional $H_2O/LiBr$ solution. With a crystallization margin of 3wt%(weight%), the optimal solution distribution ratio was found in the range of 36 to 40%. Variation of cooling air Inlet temperature has a sensitive effect on the cooling COP and corrosion problem. The simulation of heat exchangers with UA value revealed that the absorber and the evaporator are relatively important for an air-cooled system compared with the condenser and the low temperature generator. The effect of cooling air flow rate, circulation weak solution flow rate and chilled water inlet temperature were also examined. The new working fluid may provide the COP approximately 5% higher than the conventional $H_2O/LiBr$ solution.

THE PREDICTION OF SOLAR ACTIVITY FOR SOLAR MAXIMUM (태양활동극대기를 대비한 태양활동예보)

  • LEE JINNY;JANG SE JIN;KIM YEON HAN;KIM KAP-SUNG
    • Publications of The Korean Astronomical Society
    • /
    • v.14 no.2
    • /
    • pp.103-112
    • /
    • 1999
  • We have investigated the solar activity variation with period shorter than 1000 days, through Fourier transformation of solar cycle 21 and 22 data. And real time predictions of the flare maximum intensity have been made by multilinear regression method to allow the use of multivariate vectors of sunspot groups or active region characteristics. In addition, we have examined the evolution of magnetic field and current density in active regions at times before and after flare occurrence, to check short term variability of solar activity. According to our results of calculation, solar activity changes with periods of 27.1, 28.0, 52.1, 156.3, 333.3 days for solar cycle 21 and of 26.5, 27.1, 28.9, 54.1, 154, 176.7, 384.6 days for solar cycle 22. Periodic components of about 27, 28, 53, 155 days are found simultaneously at all of two solar cycles. Finally, from our intensive analysis of solar activity data for three different terms of $1977\~1982,\; 1975\~1998,\;and\;1978\~1982$, we find out that our predictions coincide with observations at hit rate of $76\%,\;63\%$, 59 respectively.

  • PDF

Comparison of Performance in CO2 Cooling System with an Ejector for Various Operating Conditions (다양한 운전조건에서 이젝터를 적용한 CO2 냉동기의 성능비교)

  • Kang, Byun;Cho, Hong-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.7
    • /
    • pp.505-512
    • /
    • 2011
  • Recently, many researchers have analyzed the performance of the transcritical $CO_2$ refrigeration cycle in order to identify opportunities to improve the system energy efficiency. The reduction of the expansion process losses is one of the key issues to improve the efficiency of the transcritical $CO_2$ refrigeration cycle. In this study, the analytical study on the performance characteristics of $CO_2$ cycle with an ejector carried out with a variation of outdoor temperature, gascooler inlet air velocity, evaporator inlet air velocity, and evaporator inlet air temperature. As a result, the system performance could be improved over 85% by using an ejector for various operating condition because of the reduction of compressor work. Moreover, the cooling capacity increased about 18% for variable outdoor condition. Therefore, the high performance of an ejector system could be maintained for wide operating conditions and system reliability could be improved compared to that of a basic system.

Effects of Refrigerant Charge Amount on the Cooling Performance of a Transcritical $CO_{2}$ Cycle (냉매충전량이 초임계 이산화탄소 사이클의 냉방성능에 미치는 영향에 대한 연구)

  • Cho Honghyun;Ryu Changgi;Kim Yongchan;Sim Yunhee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.410-417
    • /
    • 2005
  • The cooling performance of a transcritical $CO_{2}$ cycle varies significantly with a variation of refrigerant charge amount. In this study, the performance of the $CO_{2}$ system was measured and analyzed by varying refrigerant charge amount at a standard test condition. Besides, the losses of the major components in the $CO_{2}$ system were estimated by evaluating entropy generation with refrigerant charge amount. The losses in the expansion device and the gascooler show the major portion of the total loss. For undercharging conditions, the expansion loss dominates the overall system performance, while the gascooler loss increases significantly with an increase of refrigerant charge amount.