• Title/Summary/Keyword: Cycle Simulation

Search Result 1,633, Processing Time 0.026 seconds

Conceptual Design of Korea Aerospace Research Institute Lunar Explorer Dynamic Simulator

  • Rew, Dong-Young;Ju, Gwang-Hyeok;Kang, Sang-Wook;Lee, Sang-Ryool
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.4
    • /
    • pp.377-382
    • /
    • 2010
  • In lunar explorer development program, computer simulator is necessary to provide virtual environments that vehicle confronts in lunar transfer, orbit, and landing missions, and to analyze dynamic behavior of the spacecraft under these environments. Objective of simulation differs depending on its application in spacecraft development cycle. Scope of use cases considered in this paper includes simulation of software based, processor and/or hardware in the loop, and support of ground-based flight test of developed vehicle. These use cases represent early phase in development cycle but reusability of modeling results in the next design phase is considered in defining requirements. A simulator architecture in which simulator platform is located in the middle and modules for modeling, analyzing, and three dimensional visualizing are connected to that platform is suggested. Baseline concepts and requirements for simulator development are described. Result of trade study for selecting simulation platform and approaches of defining other simulator components are summarized. Finally, characters of lunar elevation map data which is necessary for lunar terrain generation is described.

A Characteristics Simulation of Heat Pump System for Sewage Water as a Heat Source (하수열원 열펌프 시스템의 성능 시뮬레이션)

  • Park, Il-Hwan;Chang, Ki-Chang;Lee, Young-Soo;Yoon, Hyung-Kee;Baek, Young-Jeen
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.4
    • /
    • pp.280-286
    • /
    • 2008
  • In this study, characteristics simulation of heat pump system is investigated for heating and cooling using sewage water as a heat source. A simulation program for preestimate operation characteristics of heat pump system is developed. The performance of this system is resolved by several variables and the characteristics which is based on actual air and sewage temperature data. The simulation results agree well with the experimental values of COP. In the analysis of system characteristics, the COP is changed between $3\sim5$ in winter season for heating load, $4\sim6$ in summer season for cooling load. As the results of Life Cycle Cost analysis over a 15 year life cycle, the energy cost could be reduced by 250 million won if a heat pump system was used instead of a conventional boiler and an absorbtion refrigerator on the office building.

An analysis on the characteristics of superheater organization of ORC system for marine waste heat recovery system(WHRS) (선박폐열회수(WHRS) ORC 시스템의 과열기 구성에 따른 특성 해석)

  • Kim, Jong-Kwon;Kim, You-Taek;Kang, Ho-Keun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.8-14
    • /
    • 2014
  • This research designed Waste Heat Recovery System(WHRS) generation system of 250kW whose working fluid is R-245fa and studied on cycle characteristics by superheater organization. It simulated two conditions; series connection and parallel connection between superheater and evaporator. In simulation of series connection of superheater and evaporator, output of 4.7% could be improved because of the increase of enthalpy by overheating of working fluid. When setting 250kW for target output, cycle flux could be reduced by 4.1%. When setting 250kW as a target output of cycle In parallel connection simulation of superheater and evaporator, cycle flux was reduced as flux of heat source fluid for superheater was increased. So, the maximum 7.9% of working fluid pump's electric power was reduced and there was no big change in cycle efficiency and net efficiency by flux ratio.

Dynamic Performance Simulation of OTEC According to Seawater Temperature Change (해수온도변화에 따른 온도차발전시스템의 동적 성능 시뮬레이션)

  • Lim, Seung-Taek;Lee, Ho-saeng;Kim, Hyeon-Ju
    • Journal of Power System Engineering
    • /
    • v.22 no.1
    • /
    • pp.34-40
    • /
    • 2018
  • In this paper, Performance of 1MW OTEC system using R32 with varying seawater temperature range is studied. Steady state cycle is designed and its output and generation efficiency were 1,014kW and 2.72%, respectively. Compared to dynamic cycle, system performance and change during long term operation is studied. The simulation is performed by decreasing surface seawater temperature from $29^{\circ}C$ to $25^{\circ}C$ with 20 minute of reaction time. Dynamic cycle with same condition applied to steady state cycle and it showed output and efficiency of 1,020kW and 2.75% respectively. Seawater temperature decreased from $29^{\circ}C$ and the vapor fraction of refrigerant decreased below 1 at $28^{\circ}C$. While the vapor fraction was above 1, the turbine output decreased by 0.017kW per second. After the seawater temperature reached $26.2^{\circ}C$, the turbine output decreased by 1.03kW per second. However, Driving the turbine below the saturation temperature caused the occurrence of surging and the influx of liquid refrigerant. When the liquid separator having a capacity of 1.0 m3 was used, the flow into the turbine was confirmed after 5 minutes from the first liquid refrigerant coming into the separator.

A comparative study on the simulation of single-stage and multi-stage refrigeration cycle using propane as a refrigerant (프로판 냉매를 활용한 단일 및 다단 냉동 사이클의 전산모사 비교 연구)

  • Noh, Sanggyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3327-3335
    • /
    • 2014
  • In this study, comparison works have been performed for single-stage and multi-stage refrigeration cycle using propane as a refrigerant in order to cool down the natural gas stream. A comparative analysis has been performed for a single, two, three and four stage refrigeration cycle using propane as a refrigerant for cooling the natural gas stream. For the simulation, natural gas feedstock properties supplied by KOGAS were utilized and Peng-Robinson equation of state model was used. As the number of compression stages increase, the condenser heat duty is decreased. The refrigeration heat duty for a four-stage refrigeration cycle is decreased by 20.36% compared to that for a single-stage refrigeration cycle. Moreover, the total refrigerant circulation rate for a four-stage refrigeration system is was reduced by 14.53% compared to the single stage refrigeration cycle. The total compression power for a four-stage compression was reduced by 41.61% compared to the single stage compression.

A Study on Regenerative OTEC System using the Condenser Effluent of Uljin Nuclear Power Plant (울진 원자력발전소 온배수를 이용한 재생식 해양온도차발전에 대한 연구)

  • Kang, Yun-Young;Park, Sung-Seek;Park, Yun-Beom;Kim, Nam-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.7
    • /
    • pp.591-597
    • /
    • 2012
  • For the past few years, the concern for clean energy has been greatly increased. Ocean thermal Energy Conversion(OTEC) power plants are studied as a viable option for the supply of clean energy. In this study, we examined the thermodynamic performance of the OTEC power system for the production of electric power. Computer simulation programs were developed under the same condition and various working fluids for closed Rankine cycle, regenerative cycle, Kalina cycle, open cycle, and hybrid cycle. The results show that the regenerative cycle showed the best system efficiency. And then we examined the thermodynamic performance of regenerative cycle OTEC power system using the condenser effluent from Uljin nuclear power plant instead of the surface water. The highest system efficiency of the condition was 4.55% and the highest net power was 181 MW.

Resolving Cycle Extension Overhead Multimedia Data Retrieval

  • Won, Youjip;Cho, Kyungsun
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.4 no.2
    • /
    • pp.164-168
    • /
    • 2002
  • In this article, we present the novel approach of avoiding temporal insufficiency of data blocks, jitter, which occurs due to the commencement of new session. We propose to make the sufficient amount of data blocks available on memory such that the ongoing session can survive the cycle extension. This technique is called ″pre-buffering″. We examine two different approaches in pre-buffering: (i) loads all required data blocks prior to starting playback and (ii) incrementally accumulates the data blocks in each cycle. We develop an elaborate model to determine the appropriate amount of data blocks necessary to survive the cycle extension and to compute startup latency involved in loading these data blocks. The simulation result shows that limiting the disk bandwidth utilization to 60% can greatly improve the startup latency as well as the buffer requirement for individual streams.

Electro Sensitive Traffic Light using Fuzzy Look Up Table

  • Hong, You-Sik;Park, Chong-Kug
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.06a
    • /
    • pp.596-700
    • /
    • 1998
  • Nowadays, with increasing many vehicles on restricted roads, the conventional traffic light creates prove startup-delaytime and end-lag-time. The conventional traffic light loses the function of optimal cycle. And so, 30∼45% of conventional traffic cycle is not matched to the present traffic cycle. In this paper proposes electrosensitive traffic light using fuzzy look up table method which will reduce the average vehicle waiting time and improve average vehicle speed. Computer simulation results prove that reducing the average vehicle waiting time which proposed considering passing vehicle length for optimal traffic cycle is better than fixed signal method which doesn't consider vehicle length.

  • PDF

Performance Characteristic of the compression-absorption hybrid cycles (흡수압축 하이브리드 사이클의 성능특성)

  • Kim Jae-Man;Kwon Oh-Kyung;Moon Choon-Geun;Seol Won-Sil;Yoon Jung-In
    • 한국가스학회:학술대회논문집
    • /
    • 1998.09a
    • /
    • pp.255-260
    • /
    • 1998
  • This study describes the results of Coefficient Of Performance(COP) analysis by cycle simulation for two types of absorption-compression hybride cycle using the water/Lithium Bromide solution pair, These types are basic hybride systems introducing a mechanical compression process into the refrigerant vapor phase of the single effect absorption cycle. In absorption-compression hybrid cycles, coefficient of performance is improved compared with absorption cycle. Hybride cycle Type ll is considered as a key technology to support energy utilization system, given its capability of utilizing waste heat to drive system with a high level of efficiency.

  • PDF

Algorithm of Optimal Traffic Signal Cycle using Neural Network and Fuzzy Rules (신경망 및 퍼지규칙을 이용한 최적 교통신호주기 알고리즘)

  • 홍용식;박종국
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.8
    • /
    • pp.88-100
    • /
    • 1997
  • This paper proposes a new concept for an optimal traffic signal cycle method which will reduce the average vehicle waiting time and improve average vehicle speed. Electro sensitive traffic system can extend the traffic cycle when there ar emany vehicles in the road or it can reduce the traffic consider vehicle length, so it can cause oveflow and reduce average vechicel waiting time at the intersection, we propose on optimal traffic cycle with fuzzy ruels and neural network. Computer simulation results prove that reducing the average vehicle waiting time which proposed considering passing vehicle's length for the optimal traffic cycle better than fixe dsignal method dosen't consider vehicle length.

  • PDF