• Title/Summary/Keyword: Cutting knife

Search Result 59, Processing Time 0.029 seconds

Characteristics of a PZT-Driven Micro Depth Adjustment Device for Cutting Coated Film (박막 절단용 PZT 구동 미세깊이 조절 장치의 특성)

  • Ryu, Sang-Oh;Kim, Hwa-Young;Ahn, Jung-Hwan
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.6
    • /
    • pp.630-635
    • /
    • 2014
  • This study aims to develop a PZT-driven depth adjustment device with a flexure hinge and to investigate its static/dynamic characteristics. This device will be applied to rapidly and accurately trace a flat surface with slight waviness of up to several hundreds of micrometers in magnitude. One typical example is to cut a film coated on a steel plate. A depth control system composed of PMAC, PZT/PZT amplifier, flexure hinge/knife, and laser displacement sensor is implemented on a desktop three-axis machine and an actual cutting test is conducted on a steel workpiece with a sinusoidal-wavy surface. It is verified that the dynamic characteristics of the device limit the maximum cutting speed and depth precision.

Development of a Rapeseed Reaping Equipment Attachable to a Conventional Combine (I) - Design and Construction of a Prototype - (보통형 콤바인 부착용 유채 예취장치 개발(I) - 시작기 설계 및 제작 -)

  • Lee, Choung-Keun;Choi, Yong;Jun, Hyun-Jong;Lee, Seung-Kyu;Ryu, Chan-Seok;Kim, Dong-Min
    • Journal of Biosystems Engineering
    • /
    • v.33 no.6
    • /
    • pp.371-378
    • /
    • 2008
  • Bio-diesel applications seem to be extended due to bio-diesel policies and changes of agricultural environment. This study was conducted to develop a rapeseed reaping equipment attachable to the conventional combine. This paper was intended to report concept design, process and manufacturing of the prototype rapeseed reaping equipment. For concept design, physical properties of "SUNMANG", which is a typical rapeseed as bio-diesel materials, were considered. The designed prototype rapeseed reaping equipment consisted of wide-width plates, finger type knifes, side cutter knifes and drive equipments. The wide-width plate is 2.1 m wide, 0.7 m long, and 0.002 m thick. The finger type cutter knifes have 14.5 fingers, 30 knifes, and the specification was 7.6 cm of pitch, 8.3 cm of length and $21^{\circ}$ of cutting angle. The side cutter knifes consisted of a hydraulic pump, a hydraulic motor, a flow control and a relief valve, a hydraulic hose, a driving equipment and a reciprocating cutter knife. The 18 reciprocating cutter knifes were 137 cm long and knife pitch, knife length and cutting angle were 7.7 cm, 10.5 cm, and $18^{\circ}$. Prototype weight of the rapeseed reaping equipment was heavier by 272 kg when compared with the manual reaping equipments. Load distributions of left and right side showed 50% and 49%, and those of front and rear side showed 64% and 36%. Static turn-over angles in left and right of the prototype were $38.1^{\circ}$ and $38.7^{\circ}$, respectively. The designed prototype rapeseed reaping equipment was properly mounted at the front of a conventional combine.

Advanced Treatment Planning Method for Gamma Knife Radiosurgery of Cerebral Arteriovenous Malformations (뇌동정맥기형의 감마나이프 방사선 수술 -치료 계획 방법의 개선을 중심으로-)

  • Jang Geon-Ho;Lim Young Jin;Hong Seong Eon;Leem Won
    • Radiation Oncology Journal
    • /
    • v.13 no.1
    • /
    • pp.87-94
    • /
    • 1995
  • Since March 1992, total 200 patients who visited our hospital as functional or organic lesions of central nervous system were treated by gamma knife stereotactic radiosurgery for 27 months. Thirty-nine patients of total cases was diagnosed as cerebral arteriovenous malformation. The rate of magnification on X-ray film was reduced by cutting fixation adaptor from 1.0 to below 1.45 times. In order to treat the deep- and lateral-seated cerebral arteriovenous malformation, we slightly modified the angiographic indicator, the commercial Leksell system, by cutting each inner sides about 5mm, We performed the more distinction of the scales by adapting 0.5mm or 1mm copper filter to angiographic indicator. The center point of indicator(X=100mm, Y=100mm, Z=100mm) is corrected by adjusting scales of X-, Y-, Z-axis to each inner 100 and outer 100 point within 1-2mm by repeated exposure of X-ray on films in trial-and-errors. We have developed the 'GKANGIO' programed as the Fortran-77 in Microvax - 3100, which can save treatment planning time and perform accurate pretreatment planning using the theoretical target metrix center. The theoretical description of the simplified method is presented for the reduction of experimental and numerical errors in treatment planning of radiosurgery.

  • PDF

Analysis of the Cutting Shape as a Function of Feed Rate and Cutting Speed of Korean and Japanese Combines

  • Jin, Byung-Ok;Lee, Min-Ho;Jo, Jin-Seok;Jung, Ho-Jun;Kim, Chi-Ho;Kim, Hyeon-Tae
    • Journal of Biosystems Engineering
    • /
    • v.42 no.2
    • /
    • pp.80-85
    • /
    • 2017
  • Purpose: In this study, we attempted to analyze, by using a high-speed camera, the cutting shape as a function of cutting speed and feed rate. We compared the differences in cutting shape between domestic and foreign combines. Methods: Experiments were performed using plastic straws, and the results of two combine cutting blades, one from the Daedong Industry and one from Kuboda, were compared. The quality and performances of cutting were measured at three cutting positions: center and 68 cm to the left and right of the center. The feed rates were 0.6 m/s, 1.1 m/s, 1.6 m/s, and the cutting speeds were 600 RPM, 990 RPM, 1,380 RPM. For each speed, the cutting shape was measured three times, and the entire procedure was also repeated three times. Results: In the experiments, the domestic cutting blade achieved better results than the Japanese cutting blade. These results were obtained by studying the combination of feed rate and cutting speed, with the domestic combine attaining approximately 80% performance of the Japanese combine. We believe that additional data analysis is required, obtained from field experiments. Conclusions: The domestic cutting knives achieved better results than the Japanese cutting knives. These results are estimated from experiments conducted with different feed rates and cutting speeds; an in-depth analysis will require experiments in the real field with actual combines and a combination of multiple variables. Repeating the investigation on the length differences, broken and cut angle with various combinations of feed rate and cutting speed, will surely help to find the optimal cutting speed.

A Numerical Analysis on the Coating Thickness in Continuous Hot-Dip Galvanizing (연속 아연 도금 코-팅 두께에 관한 수치 해석적 연구)

  • Lee, Dong-Won;Shin, Seung-Young;Kim, Byung-Ji;Kwon, Young-Doo;Kwon, Soon-Bum
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2955-2960
    • /
    • 2007
  • To control the coating thickness of zinc in the process of continuous hot-dip galvanizing, it is known from early day that the gas wiping through an air knife system is the most effective because of the obtainable of uniformity of coating thickness, possibility of thin coating, working ability in high speed and simplicity of control. But, the gas wiping using in the galvanizing process brings about a problem of splashing from the strip edge for a certain high speed of coating. And, it is known that the problem of splashing is caused mainly by the existence of separation bubble at the neighbor of the strip surface. In theses connections, in the present study, we proposed two kinds of air knife systems having the same expansion rate of nozzle, and the jet structures and coating thicknesses from a conventional and new proposed nozzles are compared. In numerical analysis, the governing equations consisted of two-dimensional time dependent Navier-Stokes equations, standard ${\kappa}-{\varepsilon}$ turbulence model to solve turbulence stress and so on are employed. As a result, it is found that it had better to use the constant rate nozzle from the point view of the energy saving to obtain the same coating thickness. Also, to reduce the size of separation bubble and to enhance the cutting ability at the strip, it is recommendable to use an air knife having the constant expansion rate nozzle.

  • PDF

A NUMERICAL STUDY ON THE COATING THICKNESS IN CONTINUOUS HOT-DIP GALVANIZING (연속 아연 도금 두께에 관한 수치 해석적 연구)

  • Lee, Dong-Won;Shin, Seung-Young;Cho, Tae-Seok;Kwon, Young-Doo;Kwon, Soon-Bum
    • Journal of computational fluids engineering
    • /
    • v.14 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • To control the coating thickness of zinc in the process of continuous hot-dip galvanizing, it is known from early days that the gas wiping through an air knife system is the most effective because of the obtainable of uniformity of coating thickness, possibility of thin coating, working ability in high speed and simplicity of control. But, the gas wiping using in the galvanizing process brings about a problem of splashing from the strip edge for a certain high speed of coating. Also, it is known that the problem of splashing directly depends upon the galvanizing speed and nozzle stagnation pressure. In theses connections, in the present study, we proposed two kinds of air knife systems having the same expansion rate of nozzle, and the jet structures and coating thicknesses from a conventional and new proposed nozzles are compared. In numerical analysis, the governing equations consisted of two-dimensional time dependent Navier-Stokes equations, standard k-e turbulence model to solve turbulence stress and so on are employed. As a result, it is found that it had better to use the constant rate nozzle from the point view of the energy saving to obtain the same coating thickness. Also, to enhance the cutting ability at the strip, it is advisable to use an air knife with the constant expansion rate nozzle.

The Microbiological Assessment of Plastic Container and Kitchen Utensils Used in Employee Feeding Foodservice Operation in Seoul (서울 시내 산업체 급식소의 plastic용기 및 기구류 위생에 관한 연구)

  • 전희정;백재은;이윤경;김은실
    • Korean journal of food and cookery science
    • /
    • v.14 no.1
    • /
    • pp.21-24
    • /
    • 1998
  • The purpose of this study was to evaluate the microbiological quality of kitchen utensils in institutional foodservices in Seoul. Total plate count of plastic container, knife, wiping clothes and cutting board are 1${\times}$$10^3$-1${\times}$10/sup/5(CFU/100 $cm^2$). There were many coliforms in plastic container (2${\times}$$10^1$CFU/100 $m^2$), knife (2-3${\times}$$10^1$CFU/100 $cm^2$), wiping clothes (4-6${\times}$$10^1$CFU/100 $cm^2$) and cutting board (4-9${\times}$$10^1$CFU/100 $cm^2$). The results of microbiological test of kitchen utensils indicated that the sanitary conditions of plastic container, knife, wiping clothes and cutting board should be improved promptly. Electron microscopic observation showed that there were too many bacteria in plastic containers.

  • PDF

Corrosion and Abrasion Characteristics of PE Sheet Laminated Corrugated Steel Pipe (PE 선피복 파형강관의 부식 및 마모 특성)

  • Kim, Seog-ku;Jeong, Jang-sik;Kwak, Phill-jae;Choi, Jun-hyang;Lee, Hyun-dong;Lee, Tae-yoon
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.2
    • /
    • pp.163-169
    • /
    • 2004
  • Feasibility of using PE sheet laminated CSP(Corrugated steel pipe) to sewers were tested via corrosion and abrasion tests for PE sheet laminated CSP; 1) corrosion test for PE film and PE coated plate, 2) corrosion test for joint of PE sheet laminated CSP, 3) corrosion test for outside of PE sheet laminated CSP, and 4) abrasion test for inside of PE sheet laminated CSP. The results for the corrosion and abrasion tests are as follows. 1. Results for corrosion tests on PE films and zinc coated steel plates that were coated with PE films show that the surfaces of both PE were not changed compared to those of original PE samples. Furthermore, PE films maintained strong adhesion on the steel plates even though they were exposed to sewage and seawater provided cutting planes of the steel plates were treated with molding. But, results for corrosion tests on the spots that were previously cut off by a knife and a cutting planes of the steel plates were treated without molding show that steel plates have been corroded if they were exposed to sewage and seawater. 2. Results for corrosion tests on joints of PE sheet laminated corrugated steel using sewage show that gathering rust was observed at cutting plane of PE sheet laminated corrugated steel after 180 days, but PE film was not flaked off. However, PE film at cutting plane was flaked off when PE sheet laminated corrugated steel was exposed to seawater. Furthermore, flaking process was severely progressed at lockseam points of which the surfaces were not smooth. 3. Results for laying PE sheet laminated corrugated steel under the ground show that the surface of untouched PE film was almost identical to that of original PE film. However, the spots that were previously cut off by a knife and a cutting plane of PE sheet laminated corrugated steel have flaked off. 4. As a result of abrasion tests conducted with PE sheet laminated corrugated steel and sand, brilliance and thickness of PE was not greatly changed under the severe abrasion conditions. Therefore, the durability of PE sheet laminated corrugated steel for abrasion was determined to be good.

A Study on the Integrated Unrolling, Cutting, and Softening System of Round Bale Silage for Pig Feeding (I) (양돈 급여에 적합한 원형베일 사일리지 해체·세절·연화 일관시스템 연구 (I))

  • Hong, Jong-Tae;Kim, Hyuck-Joo;Yu, Byeong-Kee;Hyun, Chang-Sig;Kim, Sung-Kee;Yoo, Ji-Soo;Hong, Young-Sin;Seo, Hung-Dug
    • Journal of Animal Environmental Science
    • /
    • v.19 no.1
    • /
    • pp.9-18
    • /
    • 2013
  • Currently, there was no producing system of TMR for pig feeding in Korea. In this study, we examined unrolling, cutting, and softening for the round bale silage. We designed and developed the prototype system of round bale silage for pig feeding. Unroll method were lower chain conveying and upper belt conveying which includes an hydraulic vertical fodder knife. Gathering and cutting method were rotating auger and flywheel which have 10 cutters, input roller of 280 rpm, and cutter rotating speed of 1,750 rpm. Softening device was rotating hammer in inclined cylinder adjustable to $25^{\circ}C$ and rotating speed up to 1,300 rpm. The prototype system was integrated working for unrolling, cutting, and softening. We found that when the round bale silage in unrolling apparatus cut length of 20 cm to input cutting apparatus, the cutting performance was well in continuous working up to input rate of 1,000 kg/h, the softening apparatus was working well.

Isolation and Serotyping of Listeria monocytogenes in Pork Fabrication processing Environment (돈육가공 작업환경에서 Listeria monocytogenes의 분리와 혈청형 분포조사)

  • 홍종해;안상철
    • Journal of Food Hygiene and Safety
    • /
    • v.13 no.4
    • /
    • pp.425-429
    • /
    • 1998
  • Three pork fabrication processing were examined for isolation and serotyping of Listeria monocytogenes. Three hundred thirty samples were collected from gloves, knife sharpeners, knives, cutting boards, conveyer belts, skinning machines, working room air, pig carcasses, and cut meat. Among the 234 samples taken from processing environment, the isolation rates of Listeria monocytogenes and other Listeria spp. were 17.5%, 34.2% respectively. Isolation rates of Listeria monocytogenes from different specimens during processing were 20.8% in gloves, 21.3% in knife sharpeners, 14.6% in knives, 20.8% in cutting boards, 28.6% in conveyer belts, 16.7% in skinnig machines. Listeria monocytogenes and other Listeria spp. were not detected in working room air. Isolation rate of Listeria monocytogenes 14.6% in pork was increased compared to that of 8.5% in pig carcasses (p<0.05). The serovars of 41 isolates from processing environment were 4b 36.6%, 1/2a 24.4%, 4ab 17.0%, 4a 4.9%, 1/2c 2.4%, and 4c 2.4%. The serovars of 4b, 1/2a, 4ab were detected from carcassess and cut meats.

  • PDF