• Title/Summary/Keyword: Cutoff

Search Result 1,129, Processing Time 0.03 seconds

Study on a Forward Light Changes According to the Surface Treatment of Light Cutoff Panel (차광판 표면 처리 방법에 따른 전사광 변화에 관한 연구)

  • Gu, Jinhoi;Kwon, Myunghee;Lee, Yoon-Gyeong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.1-5
    • /
    • 2014
  • Since the "Light Pollution Prevention Act" was executed, the installation of the light cutoff panel to the security lightings which caused light trespass has been increased in the local government. The light cutoff panel is effective in reducing the light trespass in term of the cost-benefit. Because the installation of the light cutoff panel is inexpensive than the change of the security lighting. But the reflected light from the surface of the light cutoff panel has been regarded as another light pollution problem to solve. Therefore, we try to improve light cutoff panel by changing the light reflectivity characteristic of the surface of the light cutoff panel. First, we laminated the surface of light cutoff panel by black powder to reduce the light reflectivity of the light cutoff panel. After the black powder lamination, the light reflectivity on the light cutoff panel improved from 85% to 5%. And we compared reflected light caused by black powder laminated light cutoff panel with the one of no surface treatment cutoff panel. The vertical illuminance was measured at 3, 6, 9m in front of the security lighting and 3, 6, 9, 12, 15, 18m in back of the security lighting to evaluate the reflected light. And the measurement height was determined of 1.5m considering the height of the 1th floor of an apartment house. In this study, we found that the reflected light from the light cutoff panel can be reduced about 90% by the black powder lamination method. The results derived from this study will be helpful to develope the various kind of light cutoff panel which minimize the adverse effect like reflected light of light cutoff panel.

Optimization of Cutoff Shields in Projection Headlight Systems to Achieve High Intensity Gradient and Low Color Separation at the Cutoff Line

  • Joo, Byung-Yun;Ko, Jae-Hyeon
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.118-124
    • /
    • 2016
  • The shape and location of the cutoff shield in a projection-type headlight system were optimized by a ray-tracing technique. A shield based on a Petsval surface showed better cutoff characteristics than a flat or cylindrical shield, such as a sharp intensity gradient and less color separation at the cutoff line. Adjustment of the shield’s location between the reflector and the aspheric lens further improved its cutoff characteristics.

Column-loss response of RC beam-column sub-assemblages with different bar-cutoff patterns

  • Tsai, Meng-Hao;Lua, Jun-Kai;Huang, Bo-Hong
    • Structural Engineering and Mechanics
    • /
    • v.49 no.6
    • /
    • pp.775-792
    • /
    • 2014
  • Static loading tests were carried out in this study to investigate the effect of bar cutoff on the resistance of RC beam-column sub-assemblages under column loss. Two specimens were designed with continuous main reinforcement. Four others were designed with different types of bar cutoff in the mid-span and/or the beam-end regions. Compressive arch and tensile catenary responses of the specimens under gravitational loading were compared. Test results indicated that those specimens with approximately equal moment strength at the beam ends had similar peak loading resistance in the compressive arch phase but varied resistance degradation in the transition phase because of bar cutoff. The compressive bars terminated at one-third span could help to mitigate the degradation although they had minor contribution to the catenary action. Among those cutoff patterns, the K-type cutoff presented the best strength enhancement. It revealed that it is better to extend the steel bars beyond the mid-span before cutoff for the two-span beams bridging over a column vulnerable to sudden failure. For general cutoff patterns dominated by gravitational and seismic designs, they may be appropriately modified to minimize the influence of bar cutoff on the progressive collapse resistance.

Fast Measurement using Wave-Cutoff Method

  • Seo, Sang-Hun;Na, Byeong-Geun;Yu, Gwang-Ho;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.30-30
    • /
    • 2011
  • The wave-cutoff tool is a new diagnostic method to measure electron density and electron temperature. Most of the plasma diagnostic tools have the disadvantage that their application to processing plasma where toxic and reactive gases are used gives rise to many problems such as contamination, perturbation, precision of measurement, and so on. We can minimize these problems by using the wave-cutoff method. Here, we will present the results obtained through the development of the wave-cutoff diagnostic method. The frequency spectrum characteristics of the wave-cutoff probe will be obtained experimentally and analyzed through the microwave field simulation by using the CST-MW studio simulator. The plasma parameters are measured with the wave-cutoff method in various discharge conditions and its results will be compared with the results of Langmuir probe. Another disadvantage is that other diagnostic methods spend a long time (~ a few seconds) to measure plasma parameters. In this presentation, a fast measurement method will be also introduced. The wave-cutoff probe system consists of two antennas and a network analyzer. The network analyzer provides the transmission spectrum and the reflection spectrum by frequency sweeping. The plasma parameters such as electron density and electron temperature are obtained through these spectra. The frequency sweeping time, the time resolution of the wave-cutoff method, is about 1 second. A short pulse with a broad band spectrum of a few GHz is used with an oscilloscope to acquire the spectra data in a short time. The data acquisition time can be reduced with this method. Here, the plasma parameter measurement methods, Langmuir probe, pulsed wave-cutoff method and frequency sweeping wave-cutoff method, are compared. The measurement results are well matched. The real time resolution is less than 1 ?sec. The pulsed wave-cutoff technique is found to be very useful in the transient plasmas such as pulsed plasma and tokamak edge plasma.

  • PDF

Luminous Environment and Light Pollution in Gas Stations with Non-cutoff Luminaires (Non-cutoff 조명기구가 설치된 주유소의 조명환경 및 빛공해 평가)

  • Kong, Hyo-Joo;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.7-16
    • /
    • 2008
  • Lighting for gas station should be carefully designed with safety and visually attraction. Recent studies have shown that non-cutoff luminaires should not be used for gas station. duo to light pollution and energy waste. This paper aims to evaluate the luminous environment in gas station with non-cutoff luminaires. The CS-100 and Radiant Imaging Prometric-1400 were used to measure the luminance of building surface, canopy, ceiling and ground surface. The result shows that the whole luminance of various combination elements in gas station increases by rising the total luminaires of the canopy. All of the gas stations with non-cutoff luminaries produce light pollution. Some guidelines for outdoor lighting in gas station is necessary.

A Cutoff Probe for the Measurement of High Density Plasma

  • Yu, Gwang-Ho;Na, Byeong-Geun;Kim, Dae-Ung;Yu, Sin-Jae;Kim, Jeong-Hyeong;Seong, Dae-Jin;Sin, Yong-Hyeon;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.148-148
    • /
    • 2012
  • A cutoff probe is the novel diagnostic method to get the absolute plasma density with simple system and less assumption. However, high density of ion flux from plasma on probe tip can make the error of plasma density measurement because the dielectric material of probe tip can be damaged by ion flux. We proposed a shielded cutoff probe using the ceramic tube for protection from ion flux. The ceramic tube on probe tip can intercept the ion flux from plasma. The transmitted spectrum using the shielded cutoff probe is good agreement with E/M wave simulation result (CST Microwave Studio) and previous circuit simulation of cutoff probe [1]. From the analysis of the measured transmitted spectrum base on the circuit modeling, the parallel resonance frequency is same as the unshielded cutoff probe case. The obtained results of electron density is presented and discussed in wide range of experimental conditions, together with comparison result with previous cutoff method.

  • PDF

Performance of Soil-Bentonite Cutoff Wall considering Defects and Formation of Bentonite Cake

  • Nguyen, The Bao;Lee, Chul-Ho;Lim, Jee-Hee;Jeoung, Jae-Hyeung;Choi, Hang-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1264-1273
    • /
    • 2010
  • Soil-bentonite cutoff walls are widely recognized to be the effective barrier for containment of wastes and groundwater. Bentonite cake is usually found remaining on the trench surface due to the use of bentonite slurry during the excavation for the cutoff wall construction. Defects also inevitably take place due to the inappropriate construction procedures or improperly mixed soil-bentonite backfill. The defects include insufficient keys and windows in the soilbentonite cutoff wall. In this study, the performance of the soil-bentonite cutoff wall is evaluated based on the flow rates through the wall. Three-dimensional numerical models were applied to simulate the groundwater flow through the soil-bentonite cutoff walls of typical geometries with consideration of the defects and bentonite cake. Results of the simulations showed that the bentonite cake has no effect in the insufficient key cases. In the keyed wall cases, the bentonite cake with very low hydraulic conductivity significantly impedes the flow of groundwater through the wall. The presence of the bentonite cake not only compromises the window defect but also renders the wall construction more effective in blocking the groundwater flow. These findings show the significance of the bentonite cake in a soil-bentonite cutoff wall construction.

  • PDF

A Study on Magnetized Inductively Coupled Plasma Using Cutoff Probe (Cutoff Probe를 이용한 자화유도결합 플라즈마의 특성 연구)

  • Son, Eui-Jeong;Kim, Dong-Hyun;Lee, Ho-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1706-1711
    • /
    • 2016
  • Electromagnetic wave simulation was performed to predict characteristics of manufactured cutoff probe at low temperature magnetized plasma medium. Microwave cutoff probe is designed for research the properties of magnetized inductively coupled plasma. It was shown that the cutoff probe method can safely be used for weakly magnetized high density plasma sources. Cutoff probe system with two port network analyzer has been prepared and applied to measure electron density distributions in large area, 13.56MHz driven weakly magnetized inductively coupled plasma source. The results shown that, the plasma frequency confirmed cut-off characteristics in low temperature plasma. Especially, cut-off characteristics was found at upper hybrid resonance frequency in the environment of the magnetic field. In case of a induced weak magnetic field in inductively coupled plasma, plasma density estimated from the cutoff frequency in the same way at unmagnetized plasma due to nearly same plasma frequency and upper hybrid resonance frequency. The plasma density is increased and uniformity is improved by applying a induced weak magnetic field in inductively coupled plasma.

A Novel Transmission line model of Cutoff Probe for precise measurement of high density plasma

  • Kim, Si-Jun;Lee, Jang-Jae;Kim, Gwang-Gi;Lee, Ba-Da;Yeom, Hui-Jung;Lee, Yeong-Seok;Kim, Dae-Ung;Kim, Jeong-Hyeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.185.1-185.1
    • /
    • 2016
  • Cutoff probe, diagnostics instrument for plasma density, have been received an extensive attention due to simple, robust and lowest assumption. Although the cutoff probe has a long history, physical model is limited in low density plasma. For that reason, we propose a novel transmission line model of cutoff probe for precise measurement of high density plasma. In addition simplified circuit model can be obtained from transmission line model. It can explain simply physics of cutoff probe in high density plasma.

  • PDF