• 제목/요약/키워드: Cut-off value

검색결과 509건 처리시간 0.027초

Comparison of Sensitivity Between Balb/c 3T3 Cell and HaCaT Cell by NRU Assay to Predict Skin Phototoxicity Potential

  • Lee, Jong-Kwon;Lee, Eun-Hee;Lee, Sun-Hee
    • Toxicological Research
    • /
    • 제18권3호
    • /
    • pp.227-232
    • /
    • 2002
  • In order to find out the appropriate in vitro method for high correlation with in vivo, we com-pared the sensitivities of phototoxicity (PT) in vitro method between in human keratinocytes, HaCaT cells and in 3T3 fibroblast cells derived from Balb/c mice. Both cells were exposed to six known phototoxic chemicals : promethazine, neutral red, chlortetracycline, amiodarone, bithionol, 8-methoxypsoralen, or non-phototoxic chemical, ALS (ammonium laureth sulfate) and then irradiated with 5 J/$cm^2$ of UVA. Cell viability ($IC_{50}$ ) was measured by neutral red uptake (NRU) assay. The ratio of $IC_{50}$ value of chemicals in the presence and absence of UVA was determined by the cut-off value. The phototoxic potential of test chemicals in NRU assay was determined by measuring the photoirriation factor (PIF) with a cut-off value of 5. In both 3T3 and HaCaT cells, all known phototoxic chemicals were positive (over 5 of PIF value), except that bithionol was found to be non-phototoxic to HaCaT cells, and ALS, non-phototoxic chemical was negative. These results suggest that Balb/c 3T3 cell was more sensitive than HaCaT cell to predict phototoxicity potential.

초음파영상에서의 임신초기 복부피하지방두께를 이용한 임신성당뇨 위험인자 평가 (Evaluation of Gestational Diabetes Mellitus Risk Factors Using Abdominal Subcutaneous Fat Thickness for Early Pregnancy in the US Imaging)

  • 김창수;양성희;김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권1호
    • /
    • pp.35-40
    • /
    • 2017
  • 본 연구는 임신초기 초음파에 의해 측정된 임산부의 복부 피하지방두께(Abdominal Subcutaneous Fat Thickness; ASFT)와 임신중기 발현되는 임신성당뇨(Gestational Diabetes Mellitus; GDM)와의 연관성을 확인하고 GDM 예측을 위한 ASFT의 기준을 알아보고자 하였다. 286명의 임산부를 대상으로 임신초기 ASFT를 측정한 후 임신중기 GDM 선별검사(50 g OGTT) 140 mg/dL 이상을 고위험군으로 산정하고 산모연령, 임신 전 체질량지수, 임신 중 체중증가량과 함께 비교 분석하였다. ROC 곡선분석을 이용하여 GDM 예측을 위한 ASFT의 cut-off value를 결정하였다. 산모연령, 임신 중 체중증가량은 임신중기 GDM과 관련성이 없었으며, 임신 전 체질량지수와 임신초기 ASFT는 정상군과 GDM 고위험군에서 의미있는 차이를 보였다. GDM 예측을 위한 ASFT의 cut-off value는 2.23 cm(AUC 0.913, Sensitivity 76.19%, Specificity 93.72%)로 결정하였다. 임신초기 초음파로 측정된 ASFT는 임신중기 GDM 예측을 위한 중요한 지표로 유용하게 평가되었다. 따라서 ASFT는 GDM을 조기에 인식하는데 있어서 보조적인 진단지표로 활용할 수 있을 것으로 사료된다.

Serum Biomarkers for Early Detection of Hepatocellular Carcinoma Associated with HCV Infection in Egyptian Patients

  • Zekri, Abdel-Rahman;Youssef, Amira Salah El-Din;Bakr, Yasser Mabrouk;Gabr, Reham Mohamed;El-Rouby, Mahmoud Nour El-Din;Hammad, Ibtisam;Ahmed, Entsar Abd El-Monaem;Marzouk, Hanan Abd El-Haleem;Nabil, Mohammed Mahmoud;Hamed, Hanan Abd El-Hafez;Aly, Yasser Hamada Ahmed;Zachariah, Khaled S.;Esmat, Gamal
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권3호
    • /
    • pp.1281-1287
    • /
    • 2015
  • Background: Early detection of hepatocellular carcinoma using serological markers with better sensitivity and specificity than alpha fetoprotein (AFP) is needed. Aims: The aim of this study was to evaluate the diagnostic value of serum sICAM-1, ${\beta}$-catenin, IL-8, proteasome and sTNFR-II in early detection of HCC. Materials and Methods: Serum levels of IL-8, sICAM-1, sTNFR-II, proteasome and ${\beta}$-catenin were measured by ELISA assay in 479 serum samples from 192 patients with HCC, 96 patients with liver cirrhosis (LC), 96 patients with chronic hepatitis C (CHC) and 95 healthy controls. Results: Serum levels of proteasome, sICAM-1, ${\beta}$-catenin and ${\alpha}FP$ were significantly elevated in HCC group compared to other groups (P-value<0.001), where serum level of IL-8 was significantly elevated in the LC and HCC groups compared to CHC and control groups (P-value <0.001), while no significant difference was noticed in patients with HCC and LC (P-value=0.09). Serum level of sTNFR-II was significantly elevated in patients with LC compared to HCC, CHC and control groups (P-value <0.001); also it was significantly higher in HCC compared to CHC and control groups (P-value <0.001). ROC curve analysis of the studied markers between HCC and other groups revealed that the serum level of proteasome had sensitivity of 75.9% and specificity of 73.4% at a cut-off value of $0.32{\mu}g/ml$ with AUC 0.803 sICAM-1 at cut off value of 778ng/ml, the sensitivity was 75.8% and the specificity was 71.8% with AUC 0.776. ${\beta}$-catenin had sensitivity and specificity of 70% and 68.6% respectively at a cut off value of 8.75ng/ml with an AUC of 0.729. sTNFR-II showed sensitivity of 86.3% and specificity of 51.8% at a cut off value of 6239.5pg/ml with an AUC of 0.722. IL-8 had sensitivity of 70.4% and specificity of 52.3% at a cut off value of 51.5pg/ml with AUC 0.631. Conclusions: Our data supported the role of proteasome, sICAM-1, sTNFR-II and ${\beta}$-catenin in early detection of HCC. Also, using this panel of serological markers in combination with ${\alpha}FP$ may offer improved diagnostic performance over ${\alpha}FP$ alone in the early detection of HCC.

Customized BMI and waist circumference cut-off values are needed to identify metabolic syndrome among South Koreans according to their Sasang constitutional type

  • Yu, Jun-Sang;Baek, Younghwa;Hyun, Daesung;Chang, Sei-Jin
    • 대한한의학회지
    • /
    • 제39권4호
    • /
    • pp.51-61
    • /
    • 2018
  • Introduction: This study evaluated whether body mass index (BMI) and waist circumference (WC) cut-offs for predicting metabolic syndrome (MetS) were different according to Sasang constitutional type. Methods: Data were obtained from 3,117 South Koreans (20-90 years old), and MetS was defined according to the revised NCEP-ATPIII criteria. Age-adjusted BMI and WC cut-offs were calculated according to Sasang constitutional type (Soyangin [SY], Taeeumin [TE], and Soeumin [SE]), sex, and age (men: ${\geq}40$ vs. <40 years, women: ${\geq}50$ vs. <50 years). Results: The prevalences of MetS were 29.9% (<40-year-old men), 35.1% (${\geq}40$-year-old men), 14.8% (<50-year-old women), and 47.7% (${\geq}50$-year-old women). The BMI ($kg/m^2$) and WC (cm) cut-offs for <40-year-old men were 25.9 and 89.9 (SY), 25.5 and 90.5 (TE), and 21.8 and 86.2 (SE). The cut-offs for ${\geq}40$-year-old men were 23.1 and 88.9 (SY), 25.0 and 89.9 (TE), and 22.2 and 87.5 (SE). The BMI and WC cut-offs for <50-year-old women were 22.5 and 81.2 (SY), 25.1 and 83.0 (TE), and 21.5 and 79.8 (SE). The cut-offs for ${\geq}50$-year-old women were 22.2 and 80.5 (SY), and 25.2 and 89.1 (TE), and 21.9 and 80.3 (SE). Conclusions: The BMI and WC cut-offs for identifying MetS varied according to Sasang constitution type.

일측성 성대 마비에서 운동단위 활동전위를 이용한 정량적 후두 근전도 분석 (Quantitative Measurement of Laryngeal Electromyography Using Motor Unit Action Potential in Unilateral Vocal Cord Paralysis)

  • 하륜;김동영;김동현;우주현
    • 대한후두음성언어의학회지
    • /
    • 제30권1호
    • /
    • pp.28-33
    • /
    • 2019
  • Background and Objectives : Laryngeal electromyography (LEMG) is valuable to evaluate the innervation status of the laryngeal muscles and the prognosis of vocal fold paralysis (VFP). However, there is a lack of agreement on quantitative interpretation of LEMG. The aim of this study is to measure the motor unit action potentials (MUAP) quantitatively in order to find cut-off values of amplitude, duration, phase for unilateral vocal fold paralysis patients. Materials and Method : Retrospective chart review was performed for the unilateral VFP patients who underwent LEMG from March 2016 to May 2018. Patient's demography, cause of VFP, vocal cord mobility, and LEMG finding were analyzed. The difference between normal and paralyzed vocal folds and cut-off values of duration, amplitude, and phase in MUAP were evaluated. Results : Thirty-six patients were enrolled in this study. Paralyzed vocal fold had significantly longer duration (p=0.021), lower amplitude (p=0.000), and smaller phase (p=0.012) than the normal. The cut-off values of duration, amplitude, and phase in MUAP for unilateral VFP were 5.15 ms, $68.35{\mu}V$, and 1.85 respectively. Conclusion : An analysis of MUAP successfully provided quantitative differences between normal and paralyzed vocal folds. But, additional research is needed to get more available cut-off value which is helpful to evaluate the status of laryngeal innervations.

Usefulness of Estimated Height Loss for Detection of Osteoporosis in Women

  • Yeoum, Soon-Gyo;Lee, Jong-Hwa
    • 대한간호학회지
    • /
    • 제41권6호
    • /
    • pp.758-767
    • /
    • 2011
  • Purpose: This study was done to examine the threshold value of estimated height loss at which the risk of osteoporosis increases and to verify its discriminative ability in the detection of osteoporosis. Methods: It was conducted based on epidemiological descriptive methods on 732 Korean women at a public healthcare center in Seoul between July and November 2010. ANOVA, Pearson correlation, logistic regression analysis and receiver operating characteristics (ROC) curve were used for data analysis. Results: There was an age-related correlation between bone mineral density (lumbar spine: F=37.88, p<.001; femur: F=54.27, p<.001) and estimated height loss (F=27.68, p<.001). Estimated height loss increased significantly with decreasing bone mineral density (lumbar spine: r=-.23, p<.001; femur: r=-.34, p<.001). The odds ratio for the point at which the estimated height loss affects the occurrence of osteoporosis was found to increase at a cut-off value of 2 cm and the area under ROC curve was .71 and .82 in lumbar spine and femur, respectively. Conclusion: The optimal cut-off value of the estimated height loss for detection of osteoporosis was 2 cm. Height loss is therefore a useful indicator for the self-assessment and prognosis of osteoporosis.

운동선수들의 혈액분석을 통한 Etrythropoietin 간접도핑검사 (Blood Analysis for Indirect Doping Control of Erythropoietin in Sports)

  • 이정란;김소영;홍지연;김명수;최명자
    • 약학회지
    • /
    • 제47권6호
    • /
    • pp.422-431
    • /
    • 2003
  • The use of recombinant human erythropoietin (rhEPO), a stimulator of erythropoiesis, banned in sports because of the medical risk associated with thrombosis. Due to analytical difficulties to differentiate between natural human EPO (hEPO) and rhEPO, blood parameters of erythropoiesis such as contents of hemoglobin (cut-off value <17.5 g/d l for man, and < 16.0 g/dl for women), hematocrit and reticulocytes (cut-off value <2.0%) were measured to focus the misuse of rhEPO. We conducted anti-doping test for 122 blood samples of the World Cup athletes. The mean values of key parameters are as follows; 14.5$\pm$1.0 g/dl for hemoglobin, 41.7$\pm$2.8% for hematocrit, and 1.3$\pm$0.4% for reticulocyte. Blood sample was found to be stable up to 8 hours for the reticulocyte measurement. In addition, the soluble transferrin receptor and ferritin levels were measured by immunoassay methods using plasma samples (n=28) in which the mean value was 0.8$\pm$0.5 $\mu\textrm{g}$/$m\ell$ and 54.6$\pm$33.7 ng/$m\ell$, respectively. The results indicate that all samples tested were negative for the blood parameters of indirect anti-doping test for hEPO misuse. The statistical evaluation suggest that several other parameters such as red blood cell, mean corpuscular hemoglobin concentration, mean corpuscular volume, mean corpuscular hemoglobin and white blood cell could be considered as factors influencing hEPO function in addition to five parameters mentioned.

An Optimal Thresholding Method for the Voxel Coloring in the 3D Shape Reconstruction

  • Ye, Soo-Young;Kim, Hyo-Sung;Yi, Young-Youl;Nam, Ki-Gon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1695-1700
    • /
    • 2005
  • In this paper, we propose an optimal thresholding method for the voxel coloring in the reconstruction of a 3D shape. Our purposed method is a new approach to resolve the trade-off error of the threshold value on determining the photo-consistency in the conventional method. Optimal thresholding value is decided to compare the surface voxel of photo-consistency with inside voxel on the optic ray of the center camera. As iterating the process of the voxels, the threshold value is approached to the optimal value for the individual surface voxel. And also, graph cut method is reduced to the surface noise on eliminating neighboring voxel. To verify the proposed algorithm, we simulated in the virtual and real environment. It is advantaged to speed up and accuracy of a 3D face reconstruction by applying the methods of optimal threshold and graph cut as compare with conventional algorithms.

  • PDF

초음파영상을 이용한 간탄력도 검사의 유용성 (The Usefulness of Liver Fibroscan Test Using Ultrasound Image)

  • 안현;이진수;임인철;양성희
    • 한국방사선학회논문지
    • /
    • 제11권4호
    • /
    • pp.205-212
    • /
    • 2017
  • 만성간질환(Chronic diffuse hepatopathy)의 진단은 간경화, 간부전, 간암으로 인한 사망률과 유병율을 감소시키는 중요한 임상과제 중 하나이다. 이에 본 연구에서는 초음파진단 영상을 바탕으로 간탄력도검사(Fibroscan)를 통해 지방간, 만성간질환을 예측할 수 있는 기준을 알아보고자 하였다. 280명의 환자를 대상으로 혈청학적 검사, 간탄력도 검사 측정값(kPa)을 분석하였으며 ROC 곡선분석을 이용하여 지방간 및 만성간질환을 예측을 위한 간탄력도 측정값의 cut-off value를 결정하였다. 혈청학적 검사에서 Bililubin, PT(prothrombin time)은 질병예측에 관련성이 없었으며(p=0.243, p=0.115), 혈당과 중성지방수치는 지방간에서 의미 있는 차이를 보이며 높게 나타났다(p<0.05). 간탄력도 측정값은 정상 대조군, 지방간, 만성간질환 순으로 높게 측정되었으며 만성간질환 예측을 위한 cut-off value는 10.3 kPa(AUC 0.98, Sensitivity 94.94%, Specificity 94.93%)로 결정하였다. 따라서 정량적인 평가로 만성간질환 환자의 진단에 일차적인 도구로 활용될 것으로 사료된다.

다운증후군위험도 예측에서 통합선별검사를 이용한 파라미터의 유의성 (Guideliness of the Parameters Using Integrated Test in Down Syndrome Risk Prediction)

  • 이진원;고성진;강세식;김창수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권4호
    • /
    • pp.549-555
    • /
    • 2016
  • 본 연구는 다운증후군 위험도의 예측을 위해 통합선별검사를 실시한 산모를 대상으로, 각 표지자의 유의성에 대한 평가를 하였다. 초음파로 측정한 NT 영상, 산모혈청 PAPP-A, AFP, uE3, hCG, 인히빈 A의 상관성을 후향적으로 분석하였다. 그 결과 NT, uE3, hCG, 인히빈 A와 유의한 상관관계를 보였다(p<.001). ROC분석에서 인히빈 A의 AUC가 0.851로 다운증후군의 가장 큰 예측인자로 분석되었으며. cut-off value 1.33 MoM(민감도 87.5%, 특이도 71.5%)으로 결정되었다. 결론적으로 통합선별검사에서 인히빈 A가 다운증후군을 예측하는 가장 유용한 인자로 나타났다. 이에 각 표지자(parameter)들의 cut-off value를 바탕으로 통합선별검사의 단점을 보완한다면 다운증후군 선별의 독립적인 지표로 사용될 수 있을 것으로 사료된다.