• Title/Summary/Keyword: Cut-off Frequency

Search Result 406, Processing Time 0.026 seconds

Development of Eyes Inspection Questionnaire(EIQ) and Regression Analysis between EIQ Items and deficiency or excess patterns of Eyes Inspection (안진(眼診) 설문지 개발 및 안진(眼診) 설문의 허실(虛實) 연관성 연구)

  • Seo, Jae-Ho;Choi, Jin-Yong;Oh, Whan-Sup;Park, Young-Bae;Park, Young-Jae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.18 no.2
    • /
    • pp.75-84
    • /
    • 2014
  • Objectives Eyes, one of visual inspection regions, present important clues to pathological patterns including deficiency and excess patterns to the clinicians. The purpose of this study was to develop Eyes Inspection Questionnaire (EIQ) and to examine which items among the EIQ were more predictive of clinicians' determination for the deficiency and excess patterns. Methods Nine questionnaire items for Visual Inspection of Eyes were extracted through the literature review. These items were presented to the 4 Korean medical doctors who are specialized in visual inspection to conduct the Delphi method. The Korean medical doctors were asked to rate the importance of each items for the corresponding Visual Inspection of Eyes, using a Likert 5-point scale(the 3 points of importance as a cut-off point). Then, out of 75 photographs submitted to the Society of HyungSang Medicine in 2009, 30 portrait pictures were selected as samples. The samples were copied to make 60 sample pictures, and then randomly assigned to 4 clinicians. The 4 clinicians evaluated the 60 samples for excess and deficiency of the eyes and were asked to check the 6 questionnaire items. The results were recorded as 5-points-scale, and their average and standard deviations were calculated. Intra- class reliability test and multi regression test were performed using SPSS 13. Results Intra-class correlation coefficient (ICC) was between 0.750 to 0.841 (P<0.05). Indices for visual inspection of the eyes were: endowment of the bone structure around the eyes; brightness of the eyes; upward deviation of the eyes; eye shapes; and definition of iris. 76.92% of deficiency symptom patterns and 86.42% of the excess symptom patterns matched the patterns predicted by the visual inspection of the eyes, according to the frequency analysis. According to the multiple regression analysis, were significantly related to the excessive symptoms, and to the deficiency symptoms. Conclusion This study is the first attempt of development for checklist of excess and deficiency of Visual Inspection of Eyes and quantitative measurement of excess and deficiency using the Visual Inspection of Eyes by the visual inspection experts. Still, additional studies are needed regarding the relationship visual inspection methods have with existing standards of diagnosis.

The Relationship of Depressive Symptomatology with a Glycemic Control in Korean Women (한국 여성에서 우울증상과 혈당 조절의 연관성)

  • Yoon, Dae-Hyun;Park, Jin-Ho;Park, Min-Jeong;Shin, Chan-Soo;Cho, Sang-Heon;Oh, Byung-Hee
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.14 no.1
    • /
    • pp.47-52
    • /
    • 2006
  • Backgrounds : Depression has been prevalent in women and maintaining optimal glycemic control is an important goal of diabetes management. Although depression is common in adults with diabetes, its relationship to glycemic control remains unclear, espacilly in Korean women. The current study examined the relationship of depressive symptomatology with glycemic control in Korean women. Methods : Beck depression inventory (BDI), $HbA_{1c}$ as an index of long-term glycemic control, fasting glucose level and body mass index (BMI) were measured in sample of 4,567 women of whom 4.7%, 216 women had diabetes, and the relationship between depression and glycemic control was analyzed. BDI Scores of 16 and above is a cut off point to indicate possible clinical depression. Results The frequency of depressed women (p<0.001) and the mean score of BDI (p<0.001) were significantly higher in diabetic women. The mean level of $HbA_{1c}$ (p<0.01) and fasting glucose (p<0.05) were higher in depressed women. There was a graded relationship between the percentile of depressed women and a degree of glycemic control impairment (p=0.001). Conclusion : The current study found the relationship of depressive symptomatology with glycemic control in Korean women. This relationship may be mediated by decreased self-care behaviors or by neurobiological dysregulation. Improving identification and treatment of depression in women with diabetes might have favorable effects on diabetic outcomes.

  • PDF

Fabrication and characterization of the 0.25 ${\mu}m$ T-shaped gate P-HEMT and its application for MMIC low noise amplifier (0.25 ${\mu}m$ T형 게이트 P-HEMT 제작 및 특성 평가와 MMIC 저잡음 증폭기에 응용)

  • Kim, Byung-Gyu;Kim, Young-Jin;Jeong, Yoon-Ha
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.1
    • /
    • pp.38-46
    • /
    • 1999
  • o.25${\mu}m$ T-shaped gate P-HEMT is fabricated and used for design of X0band three stage monolithic microwave integrated circuit(MMIC) low noise amplifier(LNA). The fabricated P-HEMT exhibits an extrinsis transconductance of 400mS/mm and a drain current of 400mA/mm. The RF and noise characteristics show that the current gain cut off frequency is 65GHz and minimum noise figure(NFmin) of 0.7dB with an associated gain of 14.8dB at 9GHz. In the design of the three stage LNA, we have used the inductive series feedback circuit topology with the short stub. The effects of series feedback to the noise figure, the gain, and the stability have been investigated to find the optimal short stub length. The designed three staage LNA showed a gain of above 33dB, a noise figure of under 1.2dB, and ainput/output return loss of under 15dB and 14dB, respectively. The results show that the fabricated P-HEMT is very suitable for a X-band LNA with high gain.

  • PDF

Development of Gait Analysis Algorithm for Hemiplegic Patients based on Accelerometry (가속도계를 이용한 편마비 환자의 보행 분석 알고리즘 개발)

  • 이재영;이경중;김영호;이성호;박시운
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.4
    • /
    • pp.55-62
    • /
    • 2004
  • In this paper, we have developed a portable acceleration measurement system to measure acceleration signals during walking and a gait analysis algorithm which can evaluate gait regularity and symmetry and estimate gait parameters automatically. Portable acceleration measurement system consists of a biaxial accelerometer, amplifiers, lowpass filter with cut-off frequency of 16Hz, one-chip microcontroller, EEPROM and RF(TX/RX) module. The algerian includes FFT analysis, filter processing and detection of main peaks. In order to develop the algorithm, eight hemiplegic patients for training set and the other eight hemiplegic patients for test set are participated in the experiment. Acceleration signals during 10m walking were measured at 60 samples/sec from a biaxial accelerometer mounted between L3 and L4 intervertebral area. The algorithm, detected foot contacts and classified right/left steps, and then calculated gait parameters based on these informations. Compared with video data and analysis by manual, algorithm showed good performance in detection of foot contacts and classification of right/left steps in test set perfectly. In the future, with improving the reliability and ability of the algerian so that calculate more gait Parameters accurately, this system and algerian could be used to evaluate improvement of walking ability in hemiplegic patients in clinical practice.

Fuzzy discretization with spatial distribution of data and Its application to feature selection (데이터의 공간적 분포를 고려한 퍼지 이산화와 특징선택에의 응용)

  • Son, Chang-Sik;Shin, A-Mi;Lee, In-Hee;Park, Hee-Joon;Park, Hyoung-Seob;Kim, Yoon-Nyun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.2
    • /
    • pp.165-172
    • /
    • 2010
  • In clinical data minig, choosing the optimal subset of features is such important, not only to reduce the computational complexity but also to improve the usefulness of the model constructed from the given data. Moreover the threshold values (i.e., cut-off points) of selected features are used in a clinical decision criteria of experts for differential diagnosis of diseases. In this paper, we propose a fuzzy discretization approach, which is evaluated by measuring the degree of separation of redundant attribute values in overlapping region, based on spatial distribution of data with continuous attributes. The weighted average of the redundant attribute values is then used to determine the threshold value for each feature and rough set theory is utilized to select a subset of relevant features from the overall features. To verify the validity of the proposed method, we compared experimental results, which applied to classification problem using 668 patients with a chief complaint of dyspnea, based on three discretization methods (i.e., equal-width, equal-frequency, and entropy-based) and proposed discretization method. From the experimental results, we confirm that the discretization methods with fuzzy partition give better results in two evaluation measures, average classification accuracy and G-mean, than those with hard partition.

The Forecasting a Maximum Barbell Weight of Snatch Technique in Weightlifting (역도 인상동작 성공 시 최대 바벨무게 예측)

  • Hah, Chong-Ku;Ryu, Ji-Seon
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.3
    • /
    • pp.143-152
    • /
    • 2005
  • The purpose of this study was to predict the failure or success of the Snatch-lifting trial as a consequence of the stand-up phase simulated in Kane's equation of motion that was effective for the dynamic analysis of multi-segment. This experiment was a case study in which one male athlete (age: 23yrs, height: 154.4cm, weight: 64.5kg) from K University was selected The system of a simulation included a multi-segment system that had one degree of freedom and one generalized coordinate for the shank segment angle. The reference frame was fixed by the Nonlinear Trans formation (NLT) method in order to set up a fixed Cartesian coordinate system in space. A weightlifter lifted a 90kg-barbell that was 75% of subject's maximum lifting capability (120kg). For this study, six cameras (Qualisys Proreflex MCU240s) and two force-plates (Kistler 9286AAs) were used for collecting data. The motion tracks of 11 land markers were attached on the major joints of the body and barbell. The sampling rates of cameras and force-plates were set up 100Hz and 1000Hz, respectively. Data were processed via the Qualisys Track manager (QTM) software. Landmark positions and force-plate amplitudes were simultaneously integrated by Qualisys system The coordinate data were filtered using a fourth-order Butterworth low pass filtering with an estimated optimum cut-off frequency of 9Hz calculated with Andrew & Yu's formula. The input data of the model were derived from experimental data processed in Matlab6.5 and the solution of a model made in Kane's method was solved in Matematica5.0. The conclusions were as follows; 1. The torque motor of the shank with 246Nm from this experiment could lift a maximum barbell weight (158.98kg) which was about 246 times as much as subject's body weight (64.5kg). 2. The torque motor with 166.5 Nm, simulated by angular displacement of the shank matched to the experimental result, could lift a maximum barbell weight (90kg) which was about 1.4 times as much as subject's body weight (64.5kg). 3. Comparing subject's maximum barbell weight (120kg) with a modeling maximum barbell weight (155.51kg) and with an experimental maximum barbell weight (90kg), the differences between these were about +35.7kg and -30kg. These results strongly suggest that if the maximum barbell weight is decided, coaches will be able to provide further knowledge and information to weightlifters for the performance improvement and then prevent injuries from training of weightlifters. It hopes to apply Kane's method to other sports skill as well as weightlifting to simulate its motion in the future study.

The reliability physics of SiGe hetero-junction bipolar transistors (실리콘-게르마늄 이종접합 바이폴라 트랜지스터의 신뢰성 현상)

  • 이승윤;박찬우;김상훈;이상흥;강진영;조경익
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.4
    • /
    • pp.239-250
    • /
    • 2003
  • The reliability degradation phenomena in the SiGe hetero-junction bipolar transistor (HBT) are investigated in this review. In the case of the SiGe HBT the decrease of the current gain, the degradation of the AC characteristics, and the offset voltage are frequently observed, which are attributed to the emitter-base reverse bias voltage stress, the transient enhanced diffusion, and the deterioration of the base-collector junction due to the fluctuation in fabrication process, respectively. The reverse-bias stress on the emitter-base junction causes the recombination current to rise, increasing the base current and degrading the current gain, because hot carriers formed by the high electric field at the junction periphery generate charged traps at the silicon-oxide interface and within the oxide region. Because of the enhanced diffusion of the dopants in the intrinsic base induced by the extrinsic base implantation, the shorter distance between the emitter-base junction and the extrinsic base than a critical measure leads to the reduction of the cut-off frequency ($f_t$) of the device. If the energy of the extrinsic base implantation is insufficient, the turn-on voltage of the collector-base junction becomes low, in the result, the offset voltage appears on the current-voltage curve.

Risk Factors of Allogenous Bone Graft Collapse in Two-Level Anterior Cervical Discectomy and Fusion

  • Woo, Joon-Bum;Son, Dong-Wuk;Lee, Su-Hun;Lee, Jun-Seok;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.450-457
    • /
    • 2019
  • Objective : Anterior cervical discectomy and fusion (ACDF) is commonly used surgical procedure for cervical degenerative disease. Among the various intervertebral spacers, the use of allografts is increasing due to its advantages such as no harvest site complications and low rate of subsidence. Although subsidence is a rare complication, graft collapse is often observed in the follow-up period. Graft collapse is defined as a significant graft height loss without subsidence, which can lead to clinical deterioration due to foraminal re-stenosis or segmental kyphosis. However, studies about the collapse of allografts are very limited. In this study, we evaluated risk factors associated with graft collapse. Methods : We retrospectively reviewed 33 patients who underwent two level ACDF with anterior plating using allogenous bone graft from January 2013 to June 2017. Various factors related to cervical sagittal alignment were measured preoperatively (PRE), postoperatively (POST), and last follow-up. The collapse was defined as the ratio of decrement from POST disc height to follow-up disc height. We also defined significant collapses as disc heights that were decreased by 30% or more after surgery. The intraoperative distraction was defined as the ratio of increment from PRE disc height to POST disc height. Results : The subsidence rate was 4.5% and graft collapse rate was 28.8%. The pseudarthrosis rate was 16.7% and there was no association between pseudarthrosis and graft collapse. Among the collapse-related risk factors, pre-operative segmental angle (p=0.047) and intra-operative distraction (p=0.003) were significantly related to allograft collapse. The cut-off value of intraoperative distraction ${\geq}37.3%$ was significantly associated with collapse (p=0.009; odds ratio, 4.622; 95% confidence interval, 1.470-14.531). The average time of events were as follows: collapse, $5.8{\pm}5.7months$; subsidence, $0.99{\pm}0.50months$; and instrument failure, $9.13{\pm}0.50months$. Conclusion : We experienced a higher frequency rate of collapse than subsidence in ACDF using an allograft. Of the various preoperative factors, intra-operative distraction was the most predictable factor of the allograft collapse. This was especially true when the intraoperative distraction was more than 37%, in which case the occurrence of graft collapse increased 4.6 times. We also found that instrument failure occurs only after the allograft collapse.

High LO-RF Isolation W-band MIMIC Single-balanced Mixer (높은 LO-RF 격리 특성의 W-band MIMIC Single-balanced 믹서)

  • An Dan;Lee Bok-Hyung;Lim Byeong-Ok;Lee Mun-Kyo;Lee Sang-Jin;Jin Jin-Min;Go Du-Hyun;Kim Sung-Chan;Shin Dong-Hoon;Park Hyung-Moo;Park Hyim-Chang;Kim Sam-Dong;Rhee Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.6 s.336
    • /
    • pp.67-74
    • /
    • 2005
  • In this paper, high LO-RF isolation W-band MIMIC single-balanced mixer was designed and fabricated using a branch line coupler and a $\lambda$/4 transmission line. The simulation results of the designed 94 GHz balun show return loss of -27.9 dB, coupling of -4.26 dB, and thru of -3.77 dB at 94 GHz, respectively. The isolation and phase difference were 23.5 dB and $180.2^{\circ}$ at 94 GHz. The W-band MIMIC single-balanced mixer was designed using the 0.1 $\mu$m InGaAs/InAlAs/GaAs Metamorphic HEMT diode. The fabricated MHEMT was obtained the cut-off frequency(fT) of 189 GHz and the maximum oscillation frequency(fmax) of 334 GHz. The designed MIMIC single-balanced mixer was fabricated using 0.1 $\mu$m MHEMT MIMIC Process. From the measurement, the conversion loss of the single-balanced mixer was 23.1 dB at an LO power of 10 dBm. Pl dB(1 dB compression point) of input and output were 10 dBm and -13.9 dBm respectively. The LO-RF isolations of single-balanced mixer was obtained 45.5 dB at 94.19 GHz. We obtained in this study a higher LO-RF isolation compared to some other balanced mixers in millimeter-wave frequencies.

MIMIC 94 GHz high isolation single balanced cascode mixer (94 GHz 대역의 높은 격리 특성의 MIMIC single balanced cascode 믹서)

  • Lee, Sang-Jin;An, Dan;Lee, Mun-Kyo;Moon, Sung-Woon;Bang, Suk-Ho;Baek, Tae-Jong;Kwon, Hyuk-Ja;Jun, Byoung-Chul;Yoon, Jin-Seob;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.9
    • /
    • pp.25-33
    • /
    • 2007
  • In this paper, the high isolation and wideband 94 GHz MIMIC(Millimeter-wave Monolithic Integrated Circuit) single balanced cascode mixer was designed and fabricated. Also, we designed and fabricated a 3 dB tandem coupler which has a high isolation and wideband characteristic. The single balanced resistive mixer which does not require an external IF balun was designed using the 0.1 ${\mu}m$ InGaAs/InAlAs/GaAs metamorphic HEMT(High Electron Mobility Transistor). The DC characteristics of MHEMT's are 665 mA/mm of drain current density, 691 mS/mm of maximum transconductance. The current gain cut-off frequency($f_T$) is 189 GHz and the maximum oscillation frequency($f_{max}$) is 334 GHz. A 94 GHz single balanced cascode mixer was fabricated using our 0.1 ${\mu}m$ MHEMT MIMIC process. From the measurements, the fabricated couplers showed wideband characteristics. The conversion loss of single balanced cascode mixer was 9.8 dB at an LO power of 10.9 dBm. The LO to RF isolation of single balanced cascode mixer was 29.5 dB at 94 GHz. We obtained in this study a higher LO-RF isolation compared to some other single balanced mixers.