• Title/Summary/Keyword: Cut-off Distance

Search Result 47, Processing Time 0.023 seconds

Analysis of Plate Cutting Performance of Aluminum Linear Shaped Charge with Non-uniform Penetration Performance (불균일한 침투성능을 갖는 알루미늄 선상성형작약의 판재 절개성능 분석)

  • Young Jae Kim
    • Journal of the Korea Society for Simulation
    • /
    • v.33 no.3
    • /
    • pp.27-35
    • /
    • 2024
  • Generally, an Linear Shaped Charge(LSC) is used for cutting a mechanical structure of various weapon systems. The penetration performance of an LSC is subjected to the type of explosive, the amount of explosive charge per unit length, the type of sheath material, stand-off distance from the target etc. In addition, the non-uniform cross-sectional shape originated from the manufacturing process may affect penetration performance. In this study, in order to analyze the penetration performance of an LSC, Computed Tomography(CT) images of its internal shape were taken and penetration experiments of the LSC were performed on a square metal bar. The experimental results showed that the penetration depths varied depending on the longitudinal position of the LSC, and at some locations, did not meet the required cutting performance. The LSC used in the experiment was manufactured to be able to cut a 4 mm plate, but in the results of the penetration performance experiment, there were many locations where the penetration depth was less than 4 mm. To find this reason, the penetration performance that did not meet the required cutting performance was simulated through AUTODYN based numerical analysis to confirm whether the LSC is cut in the plate. Through numerical analysis, it was confirmed that the penetration performance of an LSC varies depending on the thickness of the incision target due to the distribution of stress.

Low-Pass Filter with Wide Stop-Band Characteristics Using Controllable Transmission Zeros (제어 가능한 전송 영점을 이용한 광대역 차단 특성을 갖는 저역 통과 필터)

  • Lee, Geon-Cheon;Kim, Yu-Seon;Kim, Kyung-Keun;Lee, Tae-Sung;Na, Hyeon-Sik;Lim, Yeong-Seog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.8
    • /
    • pp.887-894
    • /
    • 2007
  • In this paper, design and fabrication of the LPF with controllable four transmission zeros using electric coupling and added open stub is presented. Pass-band of the LPF is GSM band, and two transmission zeros are generated by the electric coupling at the WiBro and S-DMB band, And the other two transmission zeros are generated by the open stub at the upper frequencies. Harmonic frequency of the stop-band is suppressed by the realization of the filter using quasi-lumped element with small parasitic values. $C_M$, which is the electric coupling element of the equivalent circuit, is realized by the distance control between the open stubs of the filter structure. The fabricated LPF used teflon substrate with relative permittivity of 2.6. And it has a size of $38{\times}20{\times}0.79 mm^3$, which is including a feed line. The measured 3 dB cut-off frequency is 1.55 GHz, and locations of the transmission zeros are 2.20, 2.43, 4.11 and 6.84 GHz, respectively.

The reliability physics of SiGe hetero-junction bipolar transistors (실리콘-게르마늄 이종접합 바이폴라 트랜지스터의 신뢰성 현상)

  • 이승윤;박찬우;김상훈;이상흥;강진영;조경익
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.4
    • /
    • pp.239-250
    • /
    • 2003
  • The reliability degradation phenomena in the SiGe hetero-junction bipolar transistor (HBT) are investigated in this review. In the case of the SiGe HBT the decrease of the current gain, the degradation of the AC characteristics, and the offset voltage are frequently observed, which are attributed to the emitter-base reverse bias voltage stress, the transient enhanced diffusion, and the deterioration of the base-collector junction due to the fluctuation in fabrication process, respectively. The reverse-bias stress on the emitter-base junction causes the recombination current to rise, increasing the base current and degrading the current gain, because hot carriers formed by the high electric field at the junction periphery generate charged traps at the silicon-oxide interface and within the oxide region. Because of the enhanced diffusion of the dopants in the intrinsic base induced by the extrinsic base implantation, the shorter distance between the emitter-base junction and the extrinsic base than a critical measure leads to the reduction of the cut-off frequency ($f_t$) of the device. If the energy of the extrinsic base implantation is insufficient, the turn-on voltage of the collector-base junction becomes low, in the result, the offset voltage appears on the current-voltage curve.

Improvement of lower hybrid current drive systems for high-power and long-pulse operation on EAST

  • M. Wang;L. Liu;L.M. Zhao;M.H. Li ;W.D. Ma;H.C. Hu ;Z.G. Wu;J.Q. Feng ;Y. Yang ;L. Zhu ;M. Chen ;T.A. Zhou;H. Jia;J. Zhang ;L. Cao ;L. Zhang ;R.R. Liang;B.J. Ding ;X.J. Zhang ;J.F. Shan;F.K. Liu ;A. Ekedahl ;M. Goniche ;J. Hillairet;L. Delpech
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4102-4110
    • /
    • 2022
  • Aiming at high-power and long-pulse operation up to 1000 s, some improvements have been made for both 2.45 GHz and 4.6 GHz lower hybrid (LH) systems during the recent 5 years. At first, the guard limiters of the LH antennas with graphite tiles were upgraded to tungsten, the most promising material for plasma facing components in nuclear fusion devices. These new guard limiters can operate at a peak power density of 12.9 MW/m2. Strong hot spots were usually observed on the old graphite limiters when 4.6 GHz system operated with power >2.0 MW [B. N. Wan et al., Nucl. Fusion 57 (2017) 102019], leading to a reduction of the maximum power capability. With the new limiters, 4.6 GHz LH system, the main current drive (CD) and electron heating tool for EAST, can be operated with power >2.5 MW routinely. Long-pulse operation up to 100 s with 4.6 GHz LH power of 2.4 MW was achieved in 2021 and the maximal temperature on the guard limiters measured by an infrared (IR) camera was about 540 ℃, much below the permissible value of tungsten material (~1200 ℃). A discharge with a duration of 1056 s was achieved and the 4.6 GHz LH energy injected into the plasma was up to 1.05 GJ. Secondly, the fully-active-multijunction (FAM) launcher of 2.45 GHz system was upgraded to a passive-active-multijunction (PAM), for which the density of optimum coupling was relatively low (below the cut-off value). Good coupling with reflection coefficient ~3% has been achieved with plasma-antenna distance up to 11 cm for the new PAM. Finally, in order to eliminate the effect of ion cyclotron range of frequencies (ICRF) wave on 4.6 GHz LH wave coupling, the location of the ICRF launcher was changed to a port that is located 157.5° toroidally from the 4.6 GHz LH system and is not magnetically connected.

Analysis of Heating Effect of an Infrared Heating System in a Small Venlo-type Glasshouse (소형 벤로형 유리온실에서 적외선등 난방 시스템의 난방효과 분석)

  • Lim, Mi Young;Ko, Chung Ho;Lee, Sang Bok;Kim, Hyo Kyeong;Bae, Yong Han;Kim, Young Bok;Yoon, Yong Cheol;Jeong, Byoung Ryong
    • FLOWER RESEARCH JOURNAL
    • /
    • v.18 no.3
    • /
    • pp.186-192
    • /
    • 2010
  • An infrared heating system, installed in a small venlo-type glasshouse ($280m^2$) in Gyeongsang National University, Jinju, Korea, was used to investigate its heating effect with potted Phalaenopsis, Schefflera arboricola 'Hongkong', Ficus elastica 'Variegata', and Rosa hybrida 'Yellow King' as the test plants. Temperature changes in test plants with the system turned 'On' and 'Off' were measured by using an infrared camera and the consumption of electricity by this infrared heating system was measured and analyzed. In potted Phalaenopsis, when the set air temperature of the greenhouse was $18^{\circ}C$, temperature of leaves and the growing medium were $22.8{\sim}27^{\circ}C$ and $21.3{\sim}24.3^{\circ}C$, respectively. In such tall plants as Schefflera arboricola 'Hongkong' and Ficus elastica 'Variegata', the upper part showed the highest temperature of 24.0 and $26.9^{\circ}C$, respectively. From the results of temperature change measurements, the plant temperatures were near or above the set point temperatures with some fluctuations depending on the position or distance from the infrared heating system. When air temperature between night and dawn dropped sharply, plant temperatures were maintained close to the set temperature ($18^{\circ}C$). There was a significant difference between 'On' and 'Off' states of the infrared heating system in average temperatures of root zone and leaf: 21.8 and $17.8^{\circ}C$ with the system 'On' and 20.4 and $15.5^{\circ}C$ with the system 'Off', respectively, in a cut rose Rosa hybrida 'Yellow King'. The heating load was about $24,850{\sim}35,830kcal{\cdot}h^{-1}$, which comes to about 27,000~40,000 won in Korean currency when calculated in terms of the cost of heating by a hot water heating system heated by petroleum. The cost for heating by the infrared heating system was about 35% of that of a hot water heating system. With the infrared heating system, the air temperature during the night was maintained slightly lower than the set point air temperature, probably due to the lack of air tightness of the glasshouse. Therefore, glasshouses with an infrared heating system requires further investigation including the installation space of the heat-emitting units, temperature sensor positions, and convection.

Improvement of GPS positioning accuracy by static post-processing method (정적 후처리방식에 의한 GPS의 측위정도 개선)

  • 김민선;신현옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.4
    • /
    • pp.251-261
    • /
    • 2003
  • To measure the GPS position accuracy and its distribution according to the length of the baseline, 30 minutes to 24 hours observations at the fixed location were conducted with two GPS receivers (Ll, 12 channels) on May 29 to June 2, 2002. The GPS data received at the reference station, the rover station and the ordinary times GPS observation station operated by the National Geography Institute in Korea were processed in kinematic and static post-processing methods with a post -processing software. The results obtained are summarized as follows: 1. The number of the satellite that could be observed continuously more than six hours was 16 and most of these satellites were positioned at east-west direction on May 31, 2002. The number of the satellite observed and the geometric dilution of precision (GDOP) determined by the average of every 10 minute for the day were 8 and 3.89, respectively. 2. Both the average GPS positions before and after post-processing were shifted (standalone: 1.17 m, post -processing: 0.43m) to the south and west. The twice distance root mean square (2drms) measured with standalone was 6.65m. The 2drms could be reduced to 33.8% (standard deviation 0=17.2) and 5.3% (0=2.2) of standalone by the kinematic and the static post-processing methods, respectively. 3. The relationship between the length of the baseline x (km) and the 2drms y (m) obtained by the static post-processing method was y=0.00l6x+0.006 $(R^2=0.87)$. In the case of the positioning with the static post-processing method using the GPS receiver, it was found that a positioning within 20cm 2drms was possible when the length of the baseline was less than 100km and the receiving time of the GPS is more than 30 minutes.

Causes of High PM2.5 Concentrations in Cheongju Owing to Non-Asian Dust Events (비황사 사례에 기인한 청주시 PM2.5 고농도 원인)

  • Kim, Da-Bin;Moon, Yun-Seob
    • Journal of the Korean earth science society
    • /
    • v.41 no.6
    • /
    • pp.557-574
    • /
    • 2020
  • The purpose of this study is to analyze the cause of high PM2.5 mass concentrations in Cheongju for the period of non-Asian dust days using the weather chart, the stream lines at 850 hPa, the backward trajectory, and the weather and air quality model. As a result of analyzing the time series of PM2.5 concentrations and weather charts for the episodic days in Cheongju, the weather patterns were shown in related to long-range transport of PM2.5 from China or surrounding areas. In fact, in the PM2.5 time series, 60-80 ㎍ m-3, which is more than 2-3 times higher than the concentration attributed to Cheongju activities, was observed as a background concentration related to long-range transport. The distribution of high PM2.5 concentration was typically dependent on the locations of the high and low pressures above the ground while the upper jet stream passed through the Korean Peninsula. Consequently, the high PM2.5 concentration in Cheongju is due to massive air pollutants in the form of smog originated from industrial, household and energy combustion sources of Beijing and other nearby regions of China. These air pollutants move along a fast zonal wind caused by the atmospheric pressure arrangement. high concentration of PM2.5 in Cheongju City is because the mass of air pollutants in the form of smog generated from industrial, household and energy combustion origins in Beijing or other nearby regions of China move along a fast wind speed zone according to the atmospheric pressure arrangement of long-distance transportation. Air pollutants including PM2.5 show an M-shaped pattern that passes through the topography of the Cheongju basin from north to south as a belt or band-shaped pollutant. The ground high pressure according to the above-ground high pressure expansion area and cut-off low or low pressure arrangement, or the bands in the form of river stems appear in a gradual incremental pattern that changes into a U-shape under the influence of the wind.