• Title/Summary/Keyword: Cut-Off

Search Result 2,220, Processing Time 0.035 seconds

GROUNDWATER POLLUTION CONTROL IN UNCONTROLLED WASTE LANDFILLS (폐기물 매립지 지반내에서의 지하수오염제어)

  • Lee, Gwang-Yeol;Jang, Yeon-Su;Han, Il-Yeong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1994.03a
    • /
    • pp.75-82
    • /
    • 1994
  • Groundwater in waste landfills can be contarninated by leachates produced from wastes and flow down toward rivers. These accidents are easily discovered in uncontrolled landfill sites. In this study, applications for controlling groundwater pollution and protecting river pollution were studied using installation of cut-off walls around the waste landfill. Analyses for the efficiency and applicability of the cut-off wall were made under environmental, economical anc technical considerations. Cut-off walls were installed at the upgradient and the downgradient. prediction analyses for the hydraulic head distribution over the site were made for concerning with the final cover and without the final cover. Also, the hydraulic head distribution was predicted with well-pumping on both cases, upgradient cut-off wall and downgradient cut-off wall.

  • PDF

Quantitative Evaluation of CT Artifact Elimination with various Cut-off Frequency of Hann Filter (Hann 필터의 Cut-off 주파수 변화에 따른 CT 영상의 Artifact 제거효과에 대한 정량적 평가)

  • Kang, Bo-Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.3
    • /
    • pp.5-9
    • /
    • 2008
  • In the computerized tomography(CT), various filters are using in the reconstruction algorithm to reduce or eliminate the artifacts which are intrinsically induced by the imperfection of mathematical methods for reconstruction, lack of real informations about anatomic structures in the projection image, errors in data acquisition and so on. Hann filter was used to evaluate the filter effects on the elimination of reconstruction artifact in the CT image. The quantitative study was done by changing cut-off frequency of Hann filter from 0.1 to 0.9 with frequency increasement by 0.2. NPS analysis was fulfilled for the quantitative evaluation of filter effect.

  • PDF

The Optimal Cut Off Score According to Self-Rated Health in Early Adulthood (초기 성인기 주관적 건강상태에 따른 절단 값 제시)

  • Kim, Yun-Young;Jang, Eun-Su
    • The Korean Journal of Health Service Management
    • /
    • v.11 no.2
    • /
    • pp.105-115
    • /
    • 2017
  • Objectives : The aim of this study was to suggest the optimal cut off for best, very good, good, slightly bad, and bad grades. Methods : The subjects were recruited from 4 areas of South Korea and 487 questionnaires were analyzed. The nominal and continuous self-rated health questions were used to reveal the optimal cut off and the Short Form-12 Health Survey questionnaire (SF-12) was additionally used. Frequency, Pearson's correlation coefficient, and ROC-curve analysis were used; the significance level was <.05. Results : Subjects assigned 15(3.1%), 90(18.5%), 237(48.7%), 130(26.7%), and 15(3.1%) to best, very good, good, slightly bad and bad groups respectively. The self-rated health score was associated with total Component (r=.563, p<.001), Physical Component (r=.520, p<.001) and Mental Component of SF-12 (r=.303, p<.001). The optimal cut off was 80.5, 70.5, 53.5, and 40.5 for best, very good or more, good or more, and under slightly bad respectively and area under curve was 0.898, 0.908, 0.945, and 0.908 accordingly. Conclusions : This study suggests that the self-rated health score and grade could be integrated with the optimal cut off.

Influence of die design variables on the sheared surface in cut-off process of sandwich sheet metal (샌드위치 강판의 전단가공에 있어서 전단면에 미치는 금형 설계 변수의 영향)

  • Kim J. Y.;Choi J. S.;Kim J. H.;Chung W. J.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.05a
    • /
    • pp.57-61
    • /
    • 2004
  • in order to improve the quality of the sheared surface in cutting of sandwich sheet metals the cut-off operation is mainly investigated which is the typical shearing process in sheet metal forming technology. For experiments the cut-off die is made which can be easily adjusted by die design variables such as blankholding force, pad force, and clearance. The sheet metals chose as specimen are clad304(STS304-Al1050-STS304) and anti-vibration sheet metal. The shearing process is visualized by the computer vision system installed in front of the cut-off die and the sheared surface before and after cut-off operation is measured and quantitatively compared with the help of the optical microscope. From test results the good sheared surface was shown when the clearance gets small with large blankholding force.

  • PDF

Determination of cut-off value by receiver operating characteristic curve of norquetiapine and 9-hydroxyrisperidone concentrations in urine measured by LC-MS/MS

  • Kim, Seon Yeong;Shin, Dong Won;Kim, Jin Young
    • Analytical Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.78-86
    • /
    • 2021
  • The objective of this study was to investigate urinary cut-off concentrations of quetiapine and risperidone for distinction between normal and abnormal/non-takers who were being placed on probation. Liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was employed for determination of antipsychotic drugs in urine from mentally disordered probationers. The optimal cut-off values of antipsychotic drugs were calculated using receiver operating characteristic (ROC) curve analysis. The sensitivity and specificity of the method for the detection of antipsychotic drugs in urine were subsequently evaluated. The area under the ROC curve (AUC) was 0.927 for norquetiapine and 0.791 for 9-hydroxyrisperidone, respectively. These antipsychotic drugs are classified readily in the ROC curve analysis. The cut-off values for distinguishing regular and irregular/non-takers were 39.1 ng/mL for norquetiapine and 67.9 ng/mL for 9-hydroxyrisperidone, respectively. The results of this study suggest the cut-off values of quetiapine and risperidone were highly useful to distinguish regular takers from irregular/non-takers.

Cut-Off Values of the Post-Intensive Care Syndrome Questionnaire for the Screening of Unplanned Hospital Readmission within One Year

  • Kang, Jiyeon;Jeong, Yeon Jin;Hong, Jiwon
    • Journal of Korean Academy of Nursing
    • /
    • v.50 no.6
    • /
    • pp.787-798
    • /
    • 2020
  • Purpose: This study aimed to assign weights for subscales and items of the Post-Intensive Care Syndrome questionnaire and suggest optimal cut-off values for screening unplanned hospital readmissions of critical care survivors. Methods: Seventeen experts participated in an analytic hierarchy process for weight assignment. Participants for cut-off analysis were 240 survivors who had been admitted to intensive care units for more than 48 hours in three cities in Korea. We assessed participants using the 18-item Post-Intensive Care Syndrome questionnaire, generated receiver operating characteristic curves, and analysed cut-off values for unplanned readmission based on sensitivity, specificity, and positive likelihood ratios. Results: Cognitive, physical, and mental subscale weights were 1.13, 0.95, and 0.92, respectively. Incidence of unplanned readmission was 25.4%. Optimal cut-off values were 23.00 for raw scores and 23.73 for weighted scores (total score 54.00), with an area of under the curve (AUC) of .933 and .929, respectively. There was no significant difference in accuracy for original and weighted scores. Conclusion: The optimal cut-off value accuracy is excellent for screening of unplanned readmissions. We recommend that nurses use the Post-Intensive Care Syndrome Questionnaire to screen for readmission risk or evaluating relevant interventions for critical care survivors.

Quartz를 이용한 마이크로스트립저역필터 특성에 관한 연구

  • U, Hyeong-Gwan;Kim, Eung-Gwon;Song, Jun-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.136-136
    • /
    • 2009
  • It is investigated the cut-off frequency of Z-cut quartz microstrip low pass filter by the variation of applied electric field. Designed microstrip filter was simulated using the Ensemble v7.0(Ansoft). As a result of the experiment, the cut-off frequency showed 50 MHz shift when the applied electric field was 3 kV/cm.

  • PDF

LOCAL TIMES OF GALACTIC COSMIC RAY INTENSITY MAXIMUM AND MINIMUM IN THE DIURNAL VARIATION (우주선 세기 일변화 최대 및 최소 지방시)

  • Oh Su-Yeon;Yi Yu
    • Journal of Astronomy and Space Sciences
    • /
    • v.23 no.2
    • /
    • pp.117-126
    • /
    • 2006
  • The Diurnal variation of galactic cosmic ray (GCR) flux intensity observed by the ground Neutron Monitor (NM) shows a sinusoidal pattern with the amplitude of $1{\sim}2%$ of daily mean. We carried out a statistical study on tendencies of the local times of GCR intensity daily maximum aad minimum. To test the influences of the solar activity and the location (cut-off rigidity) on the distribution in the local times of maximum and minimum GCR intensity, we have examined the data of 1996 (solar minimum) and 2000 (solar maximum) at the low-latitude Haleakala (latitude: 20.72 N, cut-off rigidity: 12.91 GeV) and the high-latitude Oulu (latitude: 65.05 N, cut-off rigidity: 0.81 GeV) NM stations. The most frequent local times of the GCR intensity daily maximum and minimum come later about $2{\sim}3$ hours in the solar activity maximum year 2000 than in the solar activity minimum you 1996. Oulu NM station whose cut-off rigidity is smaller has the most frequent local times of the GCR intensity maximum and minimum later by $2{\sim}3$ hours from those of Haleakala station. This feature is more evident at the solar maximum. The phase of the daily variation in GCR is dependent upon the interplanetary magnetic field varying with the solar activity and the cut-off rigidity varying with the geographic latitude.

Comparative Evaluation of Resolution according to Frequency Change for SPECT (단일광자방출전산화단층촬영(SPECT)을 위한 주파수 변동에 따른 분해능 비교평가)

  • Kim, Sung-Chul;Park, Soo-Yeun;Cho, Young-Kwon;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.322-331
    • /
    • 2009
  • In clinical SPECT, FWHM provides quality information of the images obtained under different observing conditions. Therefore, the purpose of this study was to determine the optimum cut off level with comparison of FWHM according to cut off levels in each filter - Band limited, Sheep-Logan, Hanning, Hamming, Low pass cosine, Parazen and Butterworth filter in a SPECT camera. I recorded images along the X, Y, Z-axis with 99mTcO4 point source and measured FWHM with profile curves. In conclusion, all filters showed the longest figures of FWHM with cut off level 0.4, which has the worst image resolution. The images with cut off level 0.7 showed best image resolution. The shortest average of FWHM in MS2 was $11.07\pm0.07mm$ using the Butterworth filter, in MS3 it was $8.44\pm0.19mm$ through using the Hanning filter.

Aperture Cut-off Filter for Reduction of Electromagnetic Field Penetration through a Slot in Conducting Screens (도체평판의 슬롯 침투 전자파 저감을 위한 개구면 차단필터)

  • Kim, Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.12
    • /
    • pp.1201-1211
    • /
    • 2014
  • The purpose of this paper is to present the aperture cut-off filter for reduction of electromagnetic field penetration through a slot in conducting screen. The reduction characteristics of electric field penetration by the aperture cut-off filter are considered. In order to establish the concept of the aperture cut-off filter, the integral equation on the slot aperture field distribution is derived and solved by method of moments, and the reduction characteristics of penetration electric fields for the incident plane wave are calculated. The numerical results showed that the aperture cut-off filter for reduction of electric field penetration through the slot can be realized. To check the validity of the concept of an aperture cut-off filter and the theoretical analysis, the calculated electric field penetration of the metallic wall with narrow slot were compared with the experimental results.