Determining Optimal Cut-off Score for the Braden Scale on Assessment of Pressure Injury for Tertiary Hospital Inpatients (상급종합병원 입원환자의 욕창발생 위험예측을 위한 Braden Scale의 타당도 검증)

  • Park, Sook Hyun;Choi, hyeyeon;Son, Youn-Jung
    • Journal of Korean Critical Care Nursing
    • /
    • v.16 no.3
    • /
    • pp.24-33
    • /
    • 2023
  • Purpose : This study aims to establish an optimal cut-off score on the Braden scale for the assessment of pressure injury to detect pressure injury risks among inpatients in a South Korean tertiary hospital. Methods : This retrospective study used electronic medical records, from January to December 2022. A total of 654 patients were included in the study. Of these, 218 inpatients with pressure injuries and 436 without pressure injuries were classified and analyzed using 1:2 Propensity Score Matching (PSM), and the generalized estimating equation was performed using SPSS Version 26 and the R Machlt package program. Results : The cut-off value on the Braden scale for distinguishing pressure injury was 17 points, and the AUC (area under the ROC curve) was 0.531 (0.484-0.579). The sensitivity was 56.6% (45.5-67.7%) and the specificity was 69.7% (66.0-73.4%). With 17 points, the Braden scale cut-off distinguished those who had pressure injuries from those who did not at the time of admission (p < .03). In the pressure injury group, the Braden score on the day of the pressure injury was 14, with significant results in all subcategories except the moisture category. Conclusion : Our findings revealed that a cut-off value of 17 was optimal for predicting the risk of pressure injuries among tertiary hospital inpatients. Future studies should evaluate the optimal cut-off values in different clinical environments. Additionally, it is necessary to conduct multicenter large sample studies to verify the effectiveness of a 17 value in PI risk assessments.

Analysis and Cut-off Adjustment of Dried Blood Spot 17alpha-hydroxyprogesterone Concentration by Birth Weight (신생아의 출생 체중에 따른 혈액 여과지 17alpha-hydroxyprogesterone의 농도 분석 및 판정 기준 조정)

  • Park, Seungman;Kwon, Aerin;Yang, Songhyeon;Park, Euna;Choi, Jaehwang;Hwang, Mijung;Nam, Hyeongyeong;Lee, Eunhee
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.14 no.2
    • /
    • pp.150-155
    • /
    • 2014
  • The measurement of $17{\alpha}$-hydroxyprogesterone ($17{\alpha}$-OHP) in a dried blood spot on filter paper is an important for screening of congenital adrenal hyperplasia (CAH). Since high levels of $17{\alpha}$-OHP are frequently observed in premature infants without congenital adrenal hyperplasia, we evaluated cuts-off based on birth weight and performed validation. Birth weight and $17{\alpha}$-OHP concentration data of 292,204 newborn screening subjects in Greencross labopratories were analyzed. The cut-off values based on birth weight were newly evaluated and validated with the original data. The mean $17{\alpha}$-OHP concentration were 7.25 ng/mL in very low birth weight (VLBW) group, 4.02 ng/mL in low birth weight (LBW) group, 2.53 g/mL in normal birth weight (NBW) group, and 2.24 ng/mL in heavy birth weight (HBW) group. The cut-offs for CAH were decided as follows: 21.12 ng/mL for VLBW and LBW groups and 11.14 ng/mL for NBW and HBW groups. When applied new cut-offs for original data, positive rates in VLBW and LBW groups were decreased and positive rates in NBW and HBW groups were increased. The cut-offs based on birth weight should be used in the screening for CAH. We believe that our new cut-off reduce the false positive rate and false negative rate and our experience for cut-off set up and validation will be helpful for other laboratories doing newborn screening test.

The Cut Off Values for Diagnosing Cold Hypersensitivity of Hands by Using Digital Infrared Thermographic Imaging (적외선 체열 촬영을 이용한 수부냉증 진단의 절단값 산정)

  • Jo, Jun-Young;Park, Kyoung-Sun;Lee, Chang-Hoon;Jang, Jun-Bock;Lee, Kyung-Sub;Lee, Jin-Moo
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.25 no.3
    • /
    • pp.95-102
    • /
    • 2012
  • Purpose: The purpose of this study is to define the cut off values of cold hypersensitivity of hands by using digital infrared thermographic imaging(DITI). Methods: Thermographic images of 130 patients with cold hypersensitivity of hands(CHHG, n=65) and non-cold hypersensitivity of hands(NCHHG, n=65) were retrospectively reviewed. We used the temperature difference the palm(PC8) and the upper arm(LU4) for diagnosing cold hypersensitivity of hands. The temperature differences of between two groups were analysed using independent samples t-tests. The cut off values were calculated by ROC curve analysis. Analyses were undertaken using SPSS version 17.0. P value of < 0.05 was considered significant. Results: The temperature difference the palm(PC8) and the upper arm(LU4) were significantly different between groups(p < 0.001). Using receiver operating characteristic curve analysis, the sensitivity, specificity, and area under the curve were 70.8%, 73.8%, respectively both hands. The AUC was 0.822 on right hand and 0.818 on left hand. The optimum cut-off value was defined as $-0.05^{\circ}C$. Conclusions: These results suggest that DITI is a reliable instrument for estimating the cold hypersensitivity of hands.

The Cut Off Values for Diagnosing Hot flashes by Using Digital Infrared Thermographic Imaging (적외선 체열 촬영을 이용한 안면홍조 진단의 절단값 산정)

  • Jo, Jun-Young;Hwang, Deok-Sang;Lee, Chang-Hoon;Jang, Jun-Bock;Lee, Kyung-Sub;Lee, Jin-Moo
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.26 no.3
    • /
    • pp.85-92
    • /
    • 2013
  • Objectives: The purpose of this study is to find diagnostic points and define the cut off values of hot flashes by using digital infrared thermographic imaging. Methods: Thermographic images of 75 patients with hot flashes (HF, n=35) and non-hot flashes (NHF, n=40) were retrospectively reviewed. We used the temperature difference between Ex-HN3 and CV17, LU4, CV12, CV4 for diagnosing hot flashes. The temperature differences of between two groups were analysed using independent samples t-tests. The cut off values were calculated by received operating characteristic curve analysis. Analyses were undertaken using SPSS version 17.0. and p-value of <0.05 was considered significant. Results: The temperature difference Ex-HN3 and LU4 were the most significantly different between groups (p<0.001). Using receiver operating characteristic curve analysis, the sensitivity, specificity, and area under the curve were 65.7%, 72.5%, 0.729, respectively. The optimum cut off value was defined as $1.00^{\circ}C$. Conclusions: These results suggest that the digital infrared thermographic imaging is a reliable instrument for estimating hot flashes.

Quantitative Measurement of Laryngeal Electromyography Using Motor Unit Action Potential in Unilateral Vocal Cord Paralysis (일측성 성대 마비에서 운동단위 활동전위를 이용한 정량적 후두 근전도 분석)

  • Ha, Ryun;Kim, Dong Young;Kim, Dong Hyun;Woo, Joo Hyun
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.30 no.1
    • /
    • pp.28-33
    • /
    • 2019
  • Background and Objectives : Laryngeal electromyography (LEMG) is valuable to evaluate the innervation status of the laryngeal muscles and the prognosis of vocal fold paralysis (VFP). However, there is a lack of agreement on quantitative interpretation of LEMG. The aim of this study is to measure the motor unit action potentials (MUAP) quantitatively in order to find cut-off values of amplitude, duration, phase for unilateral vocal fold paralysis patients. Materials and Method : Retrospective chart review was performed for the unilateral VFP patients who underwent LEMG from March 2016 to May 2018. Patient's demography, cause of VFP, vocal cord mobility, and LEMG finding were analyzed. The difference between normal and paralyzed vocal folds and cut-off values of duration, amplitude, and phase in MUAP were evaluated. Results : Thirty-six patients were enrolled in this study. Paralyzed vocal fold had significantly longer duration (p=0.021), lower amplitude (p=0.000), and smaller phase (p=0.012) than the normal. The cut-off values of duration, amplitude, and phase in MUAP for unilateral VFP were 5.15 ms, $68.35{\mu}V$, and 1.85 respectively. Conclusion : An analysis of MUAP successfully provided quantitative differences between normal and paralyzed vocal folds. But, additional research is needed to get more available cut-off value which is helpful to evaluate the status of laryngeal innervations.

Application of Point Shearwave Elastography to Breast Ultrasonography: Initial Experience Using "S-Shearwave" in Differential Diagnosis (Point Shearwave Elastography의 유방 초음파에서의 적용: "S-Shearwave"를 이용한 감별진단의 초기경험)

  • Myung Hwan Lee;Eun-Kyung Kim;Eun Ju Lee;Ha Yan Kim;Jung Hyun Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.157-165
    • /
    • 2020
  • Purpose To evaluate the optimal measurement location, cut-off value, and diagnostic performance of S-Shearwave in differential diagnosis of breast masses seen on ultrasonography (US). Materials and Methods During the study period, 225 breast masses in 197 women were included. S-Shearwave measurements were made by applying a square region-of-interest automatically generated by the US machine. Shearwave elasticity was measured three times at four different locations of the mass, and the highest shearwave elasticity was used for calculating the optimal cut-off value. Diagnostic performance was evaluated by using the area under the receiving operator characteristic curve (AUC). Results Of the 225 breast masses, 156 (69.3%) were benign and 69 (30.7%) were malignant. Mean S-Shearwave values were significantly higher for malignant masses (108.0 ± 70.0 kPa vs. 43.4 ± 38.3 kPa; p < 0.001). No significant differences were seen among AUC values at different measurement locations. With a cut-off value of 41.9 kPa, S-Shearwave showed 85.7% sensitivity, 63.9% specificity, 70.7% accuracy, and positive and negative predictive values of 51.7% and 90.8%, respectively. The AUCs for US and S-Shearwave did not show significant differences (p = 0.179). Conclusion S-Shearwave shows comparable diagnostic performance to that of grayscale US that can be applied for differential diagnosis of breast masses seen on US.

Wire-cut 방전가공에서 가공조건이 표면거칠기에 미치는 영향

  • 유중학;최만성
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.04a
    • /
    • pp.109-114
    • /
    • 1992
  • This paper describes an effect of operating condition on surface roughness in wire-cut FDM. The experimental values of surface roughness were measured by the test pieces under the condition of changing. On time, Off time, and Feed rate after fixing other conditions. The material of the test pieces is the alloy tool steel(STD 11) and was used after heat treatment. The results are as follows: 1. The surface roughness became rapidly worse according to the increase of On time and Feed rate. 2. The surface roughness became slowly better according to the increase of Off time.

Epidemiological Cut-off Values Generated for Disc Diffusion Data from Streptococcus parauberis (Streptococcus parauberis의 디스크 확산법 결과에 대한 Epidemiological Cut-off Value의 설정)

  • Chun, Won-kyong;Lee, Yoonhang;Kim, Yoon-Jae;Roh, Heyong Jin;Kim, Ahran;Kim, Nameun;Seo, Jung-Soo;Kwon, Mun-Gyeong;Lee, Ji Hoon;Kim, Do-Hyung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.52 no.4
    • /
    • pp.382-388
    • /
    • 2019
  • Streptococcosis caused by Streptococcus parauberis is a very important disease in farmed olive flounder Paralichthys olivaceus. For most fish pathogens, including S. parauberis, there are no analytical criteria to distinguish antibioticsusceptible strains from antibiotic-resistant strains. In this study, epidemiological cut-off ($CO_{WT}$) values were generated to classify 75 strains of S. parauberis isolated from 1999 to 2018 as wild type (WT) and non-wild type (NWT) using disc diffusion data and normalized resistance interpretation (NRI) analysis. The susceptibility of the isolates to 16 antibiotics was evaluated using CLSI guideline M42-A. The wild-type cut-off values for amoxicillin, erythromycin, oxytetracycline, and florfenicol for S. parauberis were ${\geq}35$, 31, 28, and 27 mm, respectively. The NWT ratios of S. parauberis strains to treatment with GEN, FFC, ENR, SXT, EFT, VAN, and CHL were 17% or less, indicating that these antibiotics may be used to treat streptococcosis caused by S. parauberis. For recent S. parauberis isolates, the NWT ratios for AMX, ERY, OTC and FFC are much higher than for strains isolated from 1999-2007. The $CO_{WT}$ data from this study will assist aquatic animal disease professionals in prescribing appropriate antibiotics for the treatment of streptococcosis caused by S. parauberis, which will help reduce the misuse and abuse of antibiotics in the aquaculture sector.

CHEMICAL COMPATIBILITY OF SOIL-BENTONITE CUT-OFF WALL FOR IN-SITU GEOENVIRONMENTAL CONTAINMENT

  • Inui, Toru;Takai, Atsushi;Katsumi, Takeshi;Kamon, Masashi;Araki, Susumu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09c
    • /
    • pp.135-139
    • /
    • 2010
  • A construction technique to install the soil-bentonite (SB) cut-off wall for in-situ geoenvironmental containment by employing the trench cutting and re-mixing deep wall method is first presented in this paper. The laboratory test results on the hydraulic barrier performance of SB in relation to the chemical compatibility are then discussed. Hydraulic conductivity tests using flexible-wall permeameters as well as swell tests were conducted for SB specimens exposed to various types and concentrations of chemicals (calcium chloride, heavy fuel oil, ethanol, and/or seawater) in the permeant and/or in the pore water of original soil. For the SB specimens in which the pore water of original soil did not contain such chemicals and thus the sufficient bentonite hydration occurred, k values were not significantly increased even when permeated with the relatively aggressive chemical solutions such as 1.0 mol/L $CaCl_2$ or 50%-concentration ethanol solution. In contrast, the SB specimens containing $CaCl_2$ in the pore water had the higher k values. The excellent linear correlation between log k and swelling pressure implies that the swelling pressure can be a good indicator for the hydraulic barrier performance of the SB.

  • PDF

A Study on the Estimation of the Fatigue Life Using the Stress Generated Models in the Steel Railroad Bridges (강철도교의 응력발생모형을 이용한 피로수명 추정에 관한 연구)

  • Yong, Hwan Sun;Kim, Seok Tae;Lee, Seong Soo
    • Journal of Korean Society of Steel Construction
    • /
    • v.8 no.4 s.29
    • /
    • pp.19-29
    • /
    • 1996
  • In this paper, it is presumed that the stress time history was generated by simulation method and investigated compatibility in regard to the reappearance of stress time history. In this procedure, the identified frequency distribution of stress range of the steel railroad bridge varies with the rational values of cut off point and bar width. Thus, we show variable aspect of the equivalent stress range results from change of cut off point and bar width. In addition, we analyze the variable of RMC and RMS model due to the cut off point and bar width of the measured stress history which influencs the prediction of fatigue life in the steel railroad bridge. The simulated stress time history is carried out by the superposition method incorporating the vertical load with rotation moment obtained from the Hermition interpolation function, and compared with developing stress results from measured maxi mum stress. Through this study, we can estimate the remaining fatigue life from a safety point of view and comparative accuracy.

  • PDF