• Title/Summary/Keyword: Cut and Cover

Search Result 150, Processing Time 0.026 seconds

Seismic Performance Evaluation of the Underground Utility Tunnel by Response Displacement Method and Response History Analysis (응답변위법과 응답이력해석법을 이용한 지중 공동구의 내진성능 평가)

  • Kwon, Ki-Yong;Lee, Jin-Sun;Kim, Yong-Kyu;Youn, Jun-Ung;Jeong, Soon-Yong
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.11
    • /
    • pp.119-133
    • /
    • 2020
  • Underground utility tunnel, the most representative cut and cover structure, is subjected to seismic force by displacement of the surrounding soil. In 2020, Korea Infrastructure Safety Corporation has published "Seismic Performance Evaluation Guideline for Existing Utility Tunnel." This paper introduces two seismic evaluation methods, RDM (Response Displacement Method) and RHA (Response History Analysis) adopted in the guide and compares the methods for an example of an existing utility tunnel. The test tunnel had been constructed in 1988 and seismic design was not considered. RDM is performed by single and double cosine methods based on the velocity response spectrum at the base rock. RHA is performed by finite difference analysis that is able to consider nonlinear behavior of soil and structure together in two-dimensional plane strain condition. The utility tunnel shows elastic behavior for RDM, but shows plastic hinge for RHA under the collapse prevention level earthquake.

Search for Faint Quasars at z~5 using Medium-band Observations

  • Shin, Suhyun;Im, Myungshin;Kim, Yongjung;Hyun, Minhee;Jeon, Yiseul;Ji, Tae-Geun;Byeon, Seoyeon;Park, Woojin;Ahn, Hojae;Taak, Yoon Chan;Kim, Sophia;lim, Gu;Hwang, Sungyong;Paek, Insu;Paek, Gregory;Kim, Minjin;Kim, Dohyeong;Kim, Jae-Woo;Yoon, Yongmin;Choi, Changsu;Hong, Jueun;Jun, Hyunsung David;Karouzos, Marios;Kim, Duho;Kim, Ji Hoon;Lee, Seong-Kook;Pak, Soojong;Park, Won-Kee
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.36.2-36.2
    • /
    • 2018
  • Cosmic reionization era in the early universe was playing a leading part on making the present universe we know. However, we have not been able to reveal the main contributor to the cosmic reionization to date. Faint quasars have been mentioned as the alternative due to the uncertainty of the faint end slope of the quasars luminosity function. With the availability of the deep (~25mag) images from Subaru Hyper Suprime-Cam (HSC) Strategic Program survey, we have tried to find more quasar with low luminosity in the ELAIS-N1 field. Faint quasar candidates were selected from several multi-band color cut criteria based on the track of the simulated quasar at z ~ 5. The Infrared Medium-deep Survey (IMS) and The UKIRT Infrared Deep Sky Survey (UKIDSS) - Deep Extragalactic Survey (DXS) provide J band information which is used to cover the relatively long wavelength range of quasar spectra. To search the reliable candidates with possible Lyman break, medium-band observation was performed by the SED camera for QUasars in EArly uNiverse(SQUEAN) in the McDonald observatory and Seoul National University 4k Camera(SNUCAM) in the Maidanak observatory. Photometric redshifts of the observed candidates were estimated from chi-square minimization. Also, we predicted the importance of the faint quasar to the cosmic reionization from the expected number density of the faint quasar.

  • PDF

Environmental Factors on the Use of Wildlife Bridge by Striped Field Mouse (Apodemus agraius) (등줄쥐의 육교형 생태통로 이용에 미치는 환경 특성)

  • Gi-Yeong Jeong;Ji-Hoon Lee;Yong-Won Mo
    • Korean Journal of Environment and Ecology
    • /
    • v.37 no.5
    • /
    • pp.337-346
    • /
    • 2023
  • Although wildlife bridge are built as a way to reduce habitat fragmentation caused by road construction, there is still a lot of debate about their effectiveness. Monitoring methods such as footprint traps and camera traps are used evaluate the effectiveness of wildlife bridge, but there is a limit to evaluate of effectiveness. In this study, the degree of use the wildlfe bridge was surveyed by striped field mouse that is likely use the wildlife bridge and surrounding as a habitat with capture-mark-recapture method.(Apodemus agraius). The distance and route of movement were identified by connecting the capture points, and the environmental factors on the use of the wildlife bridge implemented a generalized linear model(GLM) with the capture number of captured as a dependent variable. Consequently of capture, no individuals crossing the wildlife bridge, striped field mouse use the wildlife bridge as a habitat.The environmental factors affecting the use of mice were vegetation cover(1~2m, 2~8m, over 8m), vegetation construction, maximum diameter at breast height were positively correlated and slope was nagatively correlated. In conclusion, it is expected that the effectiveness of the wildlife bridge will be further improved by planting shrubs and trees and preventing high slope and cut slope increasing the utilization of the rat, such as being used as a food source in the ecosystem.

Evaluation of fire-proofing performance of reinforced concrete tunnel lining coated by newly developed material (신개발 내화재료에 피복된 철근콘크리트 터널라이닝의 내화성능평가)

  • Park, Hae-Genn;Kim, Jang-Ho Jay
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.10 no.4
    • /
    • pp.329-336
    • /
    • 2008
  • Efficient traffic network is required in urban area for good living condition. However, dense traffic network creates traffic jam and gives bad influences to the ground environment. Therefore, advanced use of underground and tunnel is required. But, in the last 20 years many tunnel fire accidents have occurred all over the world. Increase of tunnels and increase of traffics result in increase of tunnel fire. Tunnel fire creates damage to people and to the tunnel structure. Also, tunnel fire creates a big economical loss. In a mountain tunnel, the stability of the tunnel will not be disturbed by fire although the tunnel lining will get a severe damage. However, in a shield tunnel or immersed tube tunnel, cut and cover tunnel, there is a high possibility that tunnel itself will collapse by fire because their tunnel concrete lining is designed as a structural member. The aim of this experimental research is to verify the fire protection performance of newly developed cementitious material compared with the broadly used existing products in Europe and Japan. For the experiments, the general NATM tunnel concrete linings with the newly developed material were tested using fire loading curve of RABT (Maximum peak temperature is $1,200^{\circ}C$) and RWS (Maximum peak temperature is $1,350^{\circ}C$). From the test results, the newly developed fire protection material applied with 30 mm thickness showed good fire-proofing performance under RABT fire loading.

  • PDF

Analysis of Forest Change Characteristics in North Korea using Multi-temporal Satellite Images (다시기 위성영상을 이용한 북한 전체의 산림 변화 특성 분석)

  • Lee, Hyoung-Kyu;Oh, Myoung-Kwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.633-638
    • /
    • 2018
  • We are constantly hearing about the seriousness of food shortages in North Korea through various media reports. Recently, the severity of the problem has increased, and international organizations and relief organizations have become increasingly concerned. Due to the shortage of food and firewood, residents illegally cut trees in the mountains and, as a result, North Korea has become the third fastest-growing area of forest degradation in Asia. However, since North Korea cannot directly measure the extent of forest degradation, remote sensing techniques using satellite imagery have to be applied. The purpose of this study was to analyze the characteristics of forest change in North Korea, in order to understand the severity of the forest degradation problem. For this purpose, Landsat 5 TM and Landsat 8 OLI TIRS satellite images were acquired and classified. As a result, it was found that the forests have turned into wilderness in the Nampo City and Pyongyang municipalities, while the wasteland has changed into forests in the north of Yanggangdo. In addition, the total forested area of the whole region decreased by $4,166.22km^2$, the residential area decreased by $2,017.03km^2$, and the amount of agricultural land increased by $6,625.74km^2$, which is similar to the amount of forested area lost, although the difference in the overall area of the forests between 2017 and 2006 was small.

Improvement of duty rate of Meteor Burst communication with Buried Antenna (매설형 안테나를 이용한 유성 버스트 통신의 도통율 개선)

  • 김병철;이영철;김기채
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.05a
    • /
    • pp.254-260
    • /
    • 1999
  • Meteor Burst Communication can provide effective and economical means of communication where long distance VHF NLOS data transmission is needed; often ranges more than 1000 km. It has been, however, so far considered unsuitable for short distance application because of phenomenal decrease in burst durations, which leads to decreation of total duty rate of the system. This paper extensively analyzes characteristics of shot distance MB(Meteor Burst) path and shows the low duty rate may be improved by increasing burst rate through adapting antenna beam width to cover entire hot-spot region in the space and, by compensating effective burst length through cutting down man-made noises introduced by antenna. Based on the analysis, we are developed a small-opening-cavity antenna, especially designed for short distance MB path. In operation, the antenna is to be buried under ground surface so as to improve directivity and reduces noise introduction. The antenna exhibits power gain of 3 dB with 90 degree beam width and thus enables to illuminate entire hot-spot regions with the elevation angle of 8-90 degree which is the case of transmission less than 100 km. Directivity horizontal to earth surface is suppressed to minimum which enables to cut man-made noises from near-by sources down to more than 3 dB from the level reported with conventional 4 element Yagi. A series of experiments performed on 100 km MB paths have conformed that, with the antenna installed at receiving site, the burst rate and duration time have been noticed to increase by 10 and 20 percent respectively from the values obtained by conventional 4-element Yagi antenna under same testing condition.

  • PDF

Improvement of Short Range Performance of Meteor Burst Path with Buried Antenna (지하 매설형 안테나를 이용한 근거리 유성 버스트 통신의 특성개선)

  • 김병철;김기채;이무영
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.6
    • /
    • pp.788-801
    • /
    • 1998
  • Meteor Burst Communication can provide effective and economical means of communication where long distance VHF NLOS data transmission is needed ; often ranges more than 1000 km. It has been, however, so far considered unsuitable for short distance application because of phenomenal decrease in burst durations, which leads to decreation of total duty rate of the system. This paper extensively analyzes characteristics of shot distance MB(Meteor Burst) path and shows the low duty rate may be improved by increasing burst rate through adapting antennal beam width to cover entire hot-spot region in the space and, by compensating effective burst length throughcutting down man-made noises introduced by antennal. Based on the analysis, we are developed a small-opening-cavity antennal, especially designed for short distance MB path. In operation, the antenna is to be buried under ground surface so as to improve directivity and reduces noise introduction. The antennal exhibits power gain of 3 dB with 90 degree beam width and thus enables to illuminate entire hot-spot regions with the elevation angle of 8-90 degree which is the case of transmission less than 100 km. Directivity horizontal to earth surface is suppressed to minimum which enables to cut man-made noises from near-by sources down to more than 3 dB from the level reported with conventional 4 element Yagi. A series of experiments performed on 100km MB paths have conformed that, with the antenna installed at receiving site, the burst rate and duration time have been noticed to increase by 10 and 20 percent respectively from the values obtained by conventional 4-element Yagi antennal under same testing condition.

  • PDF

Estimation of Earth Pressures Acting on Box Structures Buried in Ground (지중에 매설된 박스구조물에 작용하는 토압 산정)

  • Hong, Won-Pyo;Yun, Jung-Mann;Song, Young-Suk
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.2
    • /
    • pp.23-33
    • /
    • 2015
  • The earth pressure acting on underground structure was measured by application of the instrumentation system in the subway construction site constructed by the method of cut-and-cover tunnel. The measured earth pressure was compared with the earth pressure obtained from the existed theoretical equation, and the actual earth pressure diagram acting on the underground structure was investigated. As a result of investigation, the vertical earth pressure is mainly affected by the embankment height, and the lateral earth pressure is significantly affected by whether the existence of earth retaining structures or not. The measured vertical earth pressure is very similar to the theoretical earth pressure proposed by Bierbaumer. The measured lateral earth pressure is closed to the active earth pressure proposed by Rankine rather than the earth pressure at rest. The coefficient of earth pressure in soil deposit layer is about 0.35, and the coefficient in soft rock deposit layer is about 0.21. For design and construction the underground structures, therefore, it is reasonable estimation that the lateral earth pressure acting on structures installed in soil deposit layers is an average value between active earth pressure and earth pressure at rest. In rock deposit layers, the lateral earth pressure acting on structure is an active earth pressure only.

Analytical Study of Net Section Fracture in Special Concentrically Braced Frames (중심가새골조의 순단면 파단에 관한 해석적 연구)

  • Yoo, Jung Han
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.1
    • /
    • pp.63-70
    • /
    • 2009
  • Failure modes result in fracture or tearing, which may cause deterioration of resistance and reduction of inelastic deformation capacity. The potential failure modes for Special Concentrically Braced Frames (SCBFs) include fracture or tearing of the brace, net section fracture of the brace or gusset plate, fracture of the gusset plate welds, shear fracture of the bolts, block shear, excessive bolt bearing deformation, and buckling of the gusset plate. HSS tubular braces are commonly used in SCBFs, and net section fracture of the tubular brace may also occur through the brace net section at the end of the slot cut into the tube to slip over the gusset plate. This failure mode is categorized as a tension failure mode, and may cause dramatic loss of resistance and brittle behavior. Net section reinforcement is required according to AISC design specifications (AISC 2001). In this paper, the need to reinforce the net section area was discussed. Initially, the results of the net section fracture tests done by the University of California in Berkeley were presented with the modeling of these tests using FE models. To investigate the possibility of net section fracture in an actual frame, the slot end hole model was adapted to the frame FE model, and alternate near-fault histories were applied with tension-dominated cycles, since previous analyses showed that loading history was the most critical factor in net section fracture. The need for this reinforcement (cover plate) and the tension-dominated near-fault history were investigated.

The Effects of Artificial Dead Space on the Pulmonary Ventilation of Intubated Children with Mechanical Ventilation (기관 삽관후 인공호흡기를 적용한 개심술 환아의 인공기도 체외 용적이 폐환기 상태에 미치는 영향)

  • 유정숙;윤선희;송계희;민열하
    • Journal of Korean Academy of Nursing
    • /
    • v.31 no.1
    • /
    • pp.31-42
    • /
    • 2001
  • This study was done to evaluate the effect reducing artificial dead space on intubated children. Data were collected from July 1st, 1998 to August 31st, 1999. The subjects were selected from a pediatric intensive care unit of 'S' hospital and intubated with 3.5 mm or 4.5 mm endotracheal tube after open heart surgery. They were composed of 34 patients : 17 patients were assigned to the experimental group and the rest of them were placed in the control group. The artificial airway volume was minimized in the experimental group, and the control group maintained the artificial airway volume. ETCO2, PaCO2, SPO2 were measured as indicators of pulmonary ventilation. The tools of this study were GEM-Premier and Space-Lab patient monitors. The data were analyzed using the SPSS/PC+ program. The $\chi$2 -test was used to find general characteristics. The t-test was used to test the homogenety of the pulmonary ventilation status and mechanical ventilation setting before intervention between the two groups. Also, the paired t-test was used to examine the hypothesis. The results can be summerized as : 1. CO2 can be expelled effectively from the body in case artificial dead space was decreased. 2. As the artificial dead space was reduced, the difference between ETCO2 and PaCO2 was decreased, in other words pulmonary ventilation was improved. 3. If the artificial dead space occupied above 15 percent of tidal volume, the effect of CO2 was retention revealed in the body. 4. If the artificial dead space occupied below effect. Based on the results, the following is suggested to be applied practically : 1. A kind of the ventilator circuit acting artificial dead space should be removed from the intubated children with mechanical ventilaion. 2. The endotracheal tube should not be cut because extra-body space of the endotracheal tube did not have an effect on the dead space of the intubated children. Since the researcher could not cover this aspect in the study, they recommend the following. 1. The study should be extended to the other pulmonary disease patients for the effect of improving pulmonary ventilation. 2. Also, further studying with a more narrow interval in the extra-body space of the artificial airway will be able to explain the point of artificial dead space with proper ventilation.

  • PDF