• Title/Summary/Keyword: Curved root canals

Search Result 57, Processing Time 0.021 seconds

Comparison of apical transportation and change of working length in K3, NRT AND PROFILE rotary instruments using transparent resin block (Transparent resin block을 이용한 K3, NRT, PROFILE의 apical transportation 및 working length 변화양상의 비교)

  • Yoon, Min-Jung;Song, Min-Ju;Shin, Su-Jung;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.1
    • /
    • pp.59-65
    • /
    • 2011
  • Objectives: The purpose of this study is to compare the apical transportation and working length change in curved root canals created in resin blocks, using 3 geometrically different types of Ni-Ti files, K3, NRT, and Profile. Materials and Methods: The curvature of 30 resin blocks was measured by Schneider technique and each groups of Ni-Ti files were allocated with 10 resin blocks at random. The canals were shaped with Ni-Ti files by Crown-down technique. It was analyzed by Double radiograph superimposition method (Backman CA 1992), and for the accuracy and consistency, specially designed jig, digital X-ray, and CAD/CAM software for measurement of apical transportation were used. The amount of apical transportation was measured at 0, 1, 3, 5 mm from 'apical foramen - 0.5 mm' area, and the alteration of the working length before and after canal shaping was also measured. For statistics, Kruskal-Wallis One Way Analysis was used. Results: There was no significant difference between the groups in the amount of working length change and apical transportation at 0, 1, and 3 mm area (p = 0.027), however, the amount of apical transportation at 5 mm area showed significant difference between K3 and Profile system (p = 0.924). Conclusions: As a result of this study, the 3 geometrically different Ni-Ti files showed no significant difference in apical transportation and working length change and maintained the original root canal shape.

A Comparison of Three Stainless Steel Instruments in the Preparation of Curved Root Canals in vitro (세 종류의 Stainless Steel File을 이용한 만곡근관 형성 후 근관형태 변화에 관한 비교 연구)

  • Young-Tae Kim;Seung-Ho Baek;Kwang-Sik Bae;Sung-Sam Lim;Soo-Han Yoon
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.1
    • /
    • pp.9-15
    • /
    • 2001
  • 통상적인 근관형성 과정에서 근관형태의 직선화 경향을 발견할 수 있으며, 그 결과 만곡이 심한 근관에서 이상적인 근관형태를 얻기가 어렵다. 이를 극복하기 위한 많은 기구들과 근관 성형법들이 개선되고 소개되었다. 본 연구에서는 최근에 개발된 직사각형의 단면을 가지는 stainless steel file인 RT file과 Flex-R file, K-file을 이용하여 만곡근관 형성 후 최종 근관형태를 비교하여 각 file을 평가하고자 한다. 본 실험은 Bramante등의 방법을 변형하여 술 전의 근관형태와 술 후의 근관형태를 비교하였다. Schneider의 방법을 변형하여 3차원적 만곡을 계산하여 12도에서 36도 이내에 만곡도를 가진 근관을 선택하였다. 49개의 발거된 상악대구치 협측근관이나 하악대구치 근심근관을 3개의 군으로 나누고 레진과 플라스틱으로 제작된 mold에 투명한 교정용 레진으로 매몰하였다. 근첨에서 2.5, 5, 8mm지점에서 절단하여 각 mold에서 재조립한 후 다음과 같이 근관형성을 시행하였다. 제 1군은 SS K-file을 이용하여 step-back 방법 ; 제 2군은 Flex-R file을 이용하여 balanced force 방법 ; 제 3군은 RT file을 이용하여 step-back 방법으로 근관 형성하였다. 술 전과 술 후에 각 시편들을 체현미경으로 사진촬영하여 근관 중심 위치 이동률, 근관형성으로 삭제된 상아질양, 근관형성 후 모양을 Sigma scan/ image software program으로 계산하고 One way ANOVA로 통계적 유의성을 검증하여 다음과 같은 결론을 얻었다. 1. RT file이 치근단에서 K-file보다 유의성 있게 근관의 중심을 유지하는 것으로 보였다. 치아 중앙부에서는 RT file과 Flex-R file이 K-file에 대해 유의성 있게 우수한 것으로 나타났다. 2. 근관형성 후 삭제된 상아질양에서는 치근단에서 RT file이 적게 나왔으나 유의성은 없었다. 3. 근관형성 후 절단면 모양은 원형, 타원형, 불규칙한 형태들이 다양하게 나타났고 각 군간에 유의성 있는 차이는 없었다.

  • PDF

A Comparison of Stainless Steel K-file, Profile .04, and Quantec LX Instruments to Shape Curved Root Canals in vitro (Stainless Steel K-file, Profile .04와 Quantec LX를 이용한 만곡 근관 형성후의 근관형태의 변화에 관한 비교연구)

  • Lim, Kyung-A;Yoon, Soo-Han
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.133-143
    • /
    • 2000
  • 목 적: 통상적인 근관성형 과정에서 근관형태의 직선화 경향을 발견할수 있으며 그 결과 만곡이 심한 근관에서 이상적인 근관 형태를 얻기가 어려움으로 인해 이를 극복하기 위한 많은 기구들과 근관 성형법들이 개선되었고 소개되었다. 본 연구에서는 수통형 Stainless Steel K-file, Niti 엔진 구동형 Profile .04와 Quantec LX file를 이용하여 만곡 근관의 성형 후 최종 근관 형태를 비교하고 평가하고자 한다. 방 법: 본 실험은 Bramante등의 방법을 변형하여 술 전의 근관 형태와 술 후의 근관 형태를 비교하였다. Schneider의 방법에 따라 $12^{\circ}$에서 $68^{\circ}$ 이내에 만독도를 가진 45개의 발거된 상하악 대구치의 근심근관들을 선택하여 15개씩 3개의 군으로 나누고 알루미늄으로 제작된 mold에 투명한 교정용 레진으로 매몰하였다. 근첨에서 2.5, 5, 8mm 지점에서 절단하고 각 mold에 재조립한 후 다음과 같이 근관 성형을 시행하였다. 제 1 군은 SS K-file를 이용하여 Step-back 방법; 제 2 군은 NiTi 엔진 구동형인 Profile .04 ; 제 3 군은 NiTi 엔진 구동형인 Quantec LX file로 근관 성형하였다. 술 전과 술 후에, 각 시편들을 입체 현미경으로 사진 촬영하여 근관 중심 위치 이동률, 근관성형 후 면적과 모양, 잔존 상아질의 최 소 두께를 Sigma scan / image software program으로 계산하고 One way ANOVA로 통계적 유의성을 검증하였다. 결 론: 1. Profile .04와 Quantec LX는 SS K-file보다 근관성형시 근관의 본 형태를 유지하는 경향이 있었으나 통계적으로 유의성이 없었다(p>0.05). 2. 근관 성형 후 면적은 Profile .04 엔진 구동형 NiTi file를 이용한 군이 다른 군과 비해 가장 적었으나 통계적으로 유의성이 없었다(p>0.05). 2. 모든 방법들은 같은 부위에서 같은 방향으로 전이되는 양상을 보였다. 즉, 근단부에서는 바깥쪽으로, 중앙부에서는 안쪽으로 전이하려는 경향이 있었다. 그러나, 치관부에는 그러한 법칙이 적용되지 않아 전이되는 양상이 안쪽이나 바깥쪽으로 구별되지 않게 일어났다. 3. 술 후에 근관의 모양은 원형, 타원형, 불균일한 형태들이 다양하게 나타났지만, Profile .04와 Quantec LX를 사용했을 때 주로 원형 형태의 근관을 보여주었으며 Stainless Steel K-file은 타원형이나 불균일한 근관 형태를 보였다.

  • PDF

Comparative Study on the Ability of Instruments to Maintain Original Canal Curvature of Continuous rotary System and Single File System (Continuous rotary system과 single file system의 만곡 근관 형태 유지능에 대한 비교 연구)

  • Park, Sang-Hee;Kim, Deok-Joong;Song, Yong-Beom;Lee, Hye-Yun;Kim, Hyoung-Sun;Lee, Kwang-Won;Yu, Mi-Kyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.4
    • /
    • pp.371-383
    • /
    • 2012
  • Shaping the root canal system to maintain original canal curvature is essential to clinical success in endodontic treatment. Opposed to most root canals that are curved, endodontic instruments are made from straight metal blanks. They have a tendency of straightening the root canal during preparation and frequently result in procedural errors. A new treatment method to maintain original canal curvature during shaping has been introduced for preventing procedural errors. The aim of this study was to compare the ability of instruments to maintain original canal curvature of continuous rotary system and single file system. Thirty ISO 15, 0.02 taper, Endo Training Blocks(Dentsplay Maillefer) were used. Specimens were assigned to 1 of 3 groups for shaping: specimens in group 1 were shaped with ProFile #20/.06 at the WL. Specimens in group 2 were shaped with Mtwo #35/.04 at the WL. Specimens in group 3 were shaped with WaveOne Primary reciprocating files at the WL after the glide path was achieved with PathFile. Pre- and postinstrumentation digital images were superimposed and processed with Matlab r2010b(The MathWorks Inc, Natick, MA) software to analyze the curvature-radius ratio(CRr), representing canal curvature modification. Data for comparison on the ability of instruments to maintain original canal curvature depending on each Ni-Ti file were analyzed with 1-way ANOVA(P<.05). Data for comparison on the ability of instruments to maintain original canal curvature depending on each Ni-Ti file system were analyzed with independent t-test(P<.05). A statistically significant difference(P<0.05) was noted on each Ni-Ti file. ProFile and WaveOne instrumentations maintained the original canal curvature significantly better(P<0.05) than Mtwo file. There were no significant difference(P>0.05) between continuous rotary system and single file system. Under the conditions of this study, ProFile and WaveOne instruments maintained the original curvature significantly better than Mtwo file and were less modification of the canal curvature compared. There was no significant difference between continuous rotary system and single file system in shaping of simulated canals. As clinical practitioners, it may be advantages to use hybrid approach when root canal shapes depending on the design and usage of Ni-Ti files.

Comparison of screw-in effect of three NiTi file systems used by undergraduates (학생들이 사용한 세 종류 NiTi file systems의 screw-in effect 비교)

  • Oh, Seung-Hei;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.6
    • /
    • pp.477-484
    • /
    • 2006
  • The purposes of this study were to compare the apical terminus width of simulated curved root canal prepared with three NiTi file systems used by undergraduates for evaluation the effects of flute angle and pitch or radial land on reducing screw-in effect and to determine more safe NiTi file system for inexperienced operators. Fifty inexperienced undergraduate students prepared 150 simulated curved root canals in resin blocks with three NiTi file systems ; ProFile$^{(R)}$, Hero Shaper$^{(R)}$, K3$^{TM}$. The electric motor set at a speed of 300 rpm and torque of 30 in a 16 : 1 reduction handpiece was used. The simulated root canal was prepared to ISO #25 sizes with each file system. The scanned images of pre- and post-instrumented canal of resin block were superimposed. To evaluate the screw-in effect of three NiTi file systems, apical terminus width of root canal was measured from superimposed images and statistical analysis was performed. There were significant differences in three NiTi flle systems. ProFile$^{(R)}$ had significantly smaller width than Hero Shaper$^{(R)}$ and K3$^{TM}$"" (P < 0.05), but no significant difference was observed between K3$^{TM}$ and Hero Shaper$^{(R)}$. Under the condition of this study, active file system (Hero SHaper$^{(R)}$, K3$^{TM}$) with variable pitch and helical angle had more screw-in effect than passive file system (ProFile$^{(R)}$) with constant pitch and helical angle. It seems that the radial lands play more important role in reducing screw-in effect.

Comparison of shaping ability using various Nickel-Titanium rotary files and hybrid technique (다양한 전동 니켈 티타늄 파일과 혼합사용법에 의한 근관 성형 효율 비교)

  • Kim, Jung-Won;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.530-541
    • /
    • 2007
  • Currently, various Nickel-Titanium rotary files are used in endodontic treatment, but there is no one perfect system that can be applied to any clinical situation. Therefore, the combined uses of various file systems which can emphasize the advantages of each system are introduced as hybrid instrumentation. The ProTaper system is efficient in body shaping and apical pre-enlargement but is reported to have more possibility of transportation and produce more aberrations and deformation in more or less severe curved canals. Recently, new ProTaper system(ProTaper Universal) with different configuration and cross-sectional design to overcome the week points of ProTaper have been marketed. The purpose of this study was to compare and evaluate the shaping abilities of ProTaper, ProTaper Universal system, and two hybrid methods using S-series of ProTaper Universal and Hero Shaper or ProFile. The time lapses for instrumentation were measured and the used files were inspected for distortion. The pre- and post-instrumented root canals were scanned and superimposed to evaluate the aberrations and reduction of root canal curvature and change of radius of canal curvature. The increased canal width and apical centering ratio were calculated at 1, 2, 3, 4 and 5 mm levels from apical foramen. Under the conditions of this study, the ProTaper Universal seems to have better shaping ability than ProTaper in terms of instrumented width and instrumentation time. It may be suggested that the ProTaper Universal system is efficient as much as hybrid instrumentation using ProTaper and other constant-tapered NiTi file systems in highly experienced operators.

COMPARISON OF SCREW-IN EFFECT FOR SEVERAL NICKEL-TITANIUM ROTARY INSTRUMENTS IN SIMULATED RESIN ROOT CANAL (모형 레진 근관에서 수종의 전동 니켈-티타늄 파일에 대한 screw-in effect 비교)

  • Ha, Jung-Hong;Jin, Myoung-Uk;Kim, Young-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.4
    • /
    • pp.267-272
    • /
    • 2010
  • Screw-in effect is one of the unintended phenomena that occurs during the root canal preparation with nickel-titanium rotary files. The aim of this study was to compare the screw-in effect among various nickel-titanium rotary file systems. Six different nickel-titanium rotary instruments (ISO 20/.06 taper) were used: $K3^{TM}$ (SybronEndo, Glendora, CA, USA), $M_{two}$ (VDW GmbH, Munchen, Germany), NRT with safe-tip and with active tip (Mani Inc., Shioya-gun, Japan), ProFile$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland) and ProTaper$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland). For ProTaper$^{(R)}$, S2 was selected because it has size 20. Root canal instrumentations were done in sixty simulated single-curved resin root canals with a rotational speed of 300 rpm and single pecking motion. A special device was designed to measure the force of screw-in effect. A dynamometer of the device recorded the screw-in force during simulated canal preparation and the recorded data was stored in a computer with designed software (LCV-USE-VS, Lorenz Messtechnik GmbH, Alfdorf, Germany). The data were subjected to one-way ANOVA and Tukey's multiple range test for post-hoc test. P value of less than 0.05 was regarded significant. ProTaper$^{(R)}$ produced significantly more screw-in effects than any other instruments in the study (p < 0.001). $K3^{TM}$ produced significantly more screw-in effects than $M_{two}$, and ProFile$^{(R)}$ (p < 0.001). There was no significant difference among $M_{two}$, NRT, and ProFile$^{(R)}$ (p > 0.05), and between NRT with active tip and NRT with safe one neither (p > 0.05). From the result of the present study, it was concluded, therefore, that there seems significant differences of screw-in effect among the tested nickel-titanium rotary instruments. The radial lands and rake angle of nickel-titanium rotary instrument might be the cause of the difference.