• 제목/요약/키워드: Curved root canals

검색결과 58건 처리시간 0.025초

Comparison of the shaping ability of novel thermally treated reciprocating instruments

  • Keskin, Cangul;Demiral, Murat;Sariyilmaz, Evren
    • Restorative Dentistry and Endodontics
    • /
    • 제43권2호
    • /
    • pp.15.1-15.7
    • /
    • 2018
  • Objectives: The present study aimed to evaluate the shaping ability of 2 thermally treated nickel-titanium reciprocating systems in simulated curved canals. Materials and Methods: Forty simulated canals were prepared to apical size 25 using Reciproc Blue R25 (VDW) and WaveOne Gold Primary (Dentsply Sirona) instruments. Standard pre- and post-preparation images were taken and superimposed. The removal of resin material was measured at 5 standard points: the canal orifice, halfway between the canal orifice and the beginning of the curve, the beginning of the curve, the apex of the curve, and the end-point of the simulated canal. The data were analysed using the independent sample t-test with a 5% significance threshold. Results: The canals in which Reciproc Blue R25 was used showed a significantly greater widening than those in which WaveOne Gold was used at 4 of the 5 measurement points (p < 0.05). The Reciproc Blue R25 instrument removed significantly more resin from the inner aspect of the curve at 2 of the 5 points and similar amounts at the remaining 3 points. At the 2 apical points, there was no significant difference between the Reciproc Blue R25 and WaveOne Gold Primary instruments. Conclusion: Both instruments respected the original canal anatomy; however, WaveOne Gold resulted in a more conservative shape with less transportation.

수종의 근관형성 방법이 근관 형태에 미치는 영향 (THE EFFECT OF SOME CANAL PREPARATION TECHNIQUES ON THE SHAPE OF ROOT CANALS)

  • 이지현;조용범
    • Restorative Dentistry and Endodontics
    • /
    • 제24권2호
    • /
    • pp.337-345
    • /
    • 1999
  • The purpose of this study was to compare the shape of root canal after instrumentation with some engine driven NiTi files. Thirty narrow and curved canals(15-35 degree) of mesial canals of extracted human mandibular first molars were divided into three groups. Group 1: After radicular access with Gates Glidden drill, apical shaping using step back method with Flexo file Group 2: After radicular access with Gates Glidden drill, apical shaping with Profile .04 Group 3: Canal shaping with GT file and Profile .04. Using modified Bramante technique, the root was sectioned at 2 mm from apical foramen, height of curvature, 2 mm from canal orifice. Canal centering ratio, amount of transport, amount of dentin removed, shape of canal were measured and statistical analysis is done using SPSS Program V 7.5. The results were as follows: 1. Canal centering ratio of group 3 was the lowest at coronal part, but there was no statistical difference. Centering ratio of group 2 was the lowest at curve part, and there was statistical difference between group 1(P<0.05). Centering ratio of group 2 was the lowest at apical part, but there was no statistic difference. 2. Amount of transport of group 3 was the lowest at coronal part, but there was no statistical difference. Amount of transport of group 2 was the lowest at curve part, and there was statistical difference between group 1(P<0.05). Amount of transport of group 3 was the lowest at apical part, and there was statistical difference between group 1 and group 2, group 1 and group 3(P<0.05). 3. Amount of dentin removed of group 3 was the lowest at coronal part, bur there was no statistical difference. Amount of dentin removed of group 2 was the lowest at curve part, but there was no statistical difference. Amount of dentin removed or group 2 was the lowest at apical part, and there was statistical difference between group 1 and group 2, group 1 and group 3(P<0.05). 4. The shape of the canals after instrumentation varied among the groups. The majority of canals at coronal and curve part for group 1 were round in shape(7 in 10), those at apical part were oval(8 in 10). The majority of canals at coronal part for group 2 were round in shape(7 in 10) and there was no difference in the number of shape at other part. There was no difference in the number of shape at every part for group 3. As above results, NiTi rotary instrumentation showed a trend to remain more centered in the canal than SS file instrumentation. At using NiTi file, coronal shaping with Gates Glidden drill was not statistically different from shaping with GT file. But shaping with GT file showed tapered canals, so it may be said that shaping with GT file is a safe and valuable instrumentation method.

  • PDF

근단부 성형 크기에 따른 다양한 전동 니켈티타늄 파일의 중심 변위율 및 만곡도 감소 비교 (Comparison of the centering ratio and canal curvature reduction according to the apical preparation size using various NiTi rotary instruments)

  • 곽상원;박정길;허복;김현철
    • 대한치과의사협회지
    • /
    • 제47권7호
    • /
    • pp.435-443
    • /
    • 2009
  • The purpose of this study was to compare the centering ratio and reduction of canal curvature according to the preparation sizes of #30, #40 and #50 using three rotary NiTi instruments which have different shaft tapers. Seventy-two simulated root canals in clear resin blocks (Endo Training Bloc; Dentsply Maillefer, Ballaigues, Switzerland) were divided as following 3 groups according to the file system; the 24 canal blocks prepared with each of ProTaper Universal system (Group P), LightSpeed eXtra system (Group L), and K3 (Group K). The pre- and post-instrumented root canals were scanned and superimposed to evaluate and calculate the centering ratio and reduction of canal curvature. Mean scores of each group were statistically analyzed using one-way ANOV A and Duncan's multiple range test for post-hoc comparison. The results were as followings: 1. Group L showed better centering ratio, followed by K and P. And all experimental groups generally showed increasing tendency of centering ratio as the apical size was increasing from #30 to #50, except at 1 mm level of group P where showed reducing tendency of centering ratio. The smaller the ratio, the better the instrument remained centered in the canal. 2. Group P showed more decrease of canal curvature at all apical shaping size (p < 0.05). Under the conditions of this study, the shaft design could affect the quality of canal shaping and the smooth taperless flexible (LightSpeed) shaft design was capable of preparing canals with good morphological characteristics in curved canals.

  • PDF

엔진구동형 NiTi 파일의 근관성형효과 비교 (A COMPARISON OF THE SHAPING ABILITY OF FOUR ROTARY NICKEL-TITANIUM FILES IN SIMULATED ROOT CANALS)

  • 김보혜;최경규;박상혁;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제35권2호
    • /
    • pp.88-95
    • /
    • 2010
  • 이 연구의 목적은 4가지 엔진구동형 NiTi 기구의 근관성형력을 비교하는 것이다. 32개의 투명레진모형을 사용하여 파일의 단면도가 S자 형태이고 "single length"방법으로 근관성형을 시행하는 Mtwo와 crown-down 방법으로 근관성형을 하는 Profile, ProTaper Universal 및 K3로 근관성형을 하였다 (n = 8). 모든 근관은 한사람의 술자가 근단공 크기가 #30이 될 때까지 성형하였다. 기구 사용 전과 후 근관 모양을 디지털 영상을 기록하였고, 컴퓨터 영상 분석 프로그램(Expression Scanner와 Adobe Photoshop CS)으로 평가하였다. 다음과 같은 결론을 얻었다. 근첨으로부터 1, 2, 3, 4, 5, 6, 7 mm 떨어진 부위의 내측과 외측으로 삭제된 레진 양을 측정하였고, 자료는 SPSS법으로 비교 분석하였다. 1. 근관형성 시간은 Mtwo가 84.50초로 가장 짧았으며, 총 작업시간은 K3가 269.37초로 가장 길었다(p < 0.05). 2. 기구의 변형과 파절은 모든 구동형 NiTi 파일에서 발생하지 않았다. 3. 근관 내측 폭경의 변화는 Profile이 1, 2 mm 부위를 제외한 다른 부위에서 가장 적었으며, ProTaper Universal은 모든 부위에서 가장 많았다(p < 0.05). 4. 근관 외측 폭경의 변화는 Mtwo이 1 mm 부위를 제외한 모든 부위에서 가장 적었으며, Profile은 3, 4 mm 부위에서 가장 많았다(p < 0.05). ProTaper Universal와 K3는 1, 2, 6, 7 mm 부위에서 가장 많았다(p < 0.05). 5. 근관중심변위율(centering ratio)은 Profile이 1, 4, 5, 6 mm 부위에서 가장 적었다(p < 0.05). 이상의 결과, 구동성 NiTi 파일을 이용한 만곡 근관의 근관형성은 치경부는 ProTaper와 같은 삭제력이 높은 파일을 사용하는 것이 근관 입구를 효과적으로 넓히고 더 나은 taper를 형성하며, 근단부는 Profile과 같은 근관 중심 변위가 적은 파일을 사용하는 것이 근관형성 시간을 단축하고 근단부의 근관 변형(transportation)을 줄일 수 있다고 판단된다.

만곡된 레진 모형 근관에서 4종의 엔진 구동형 니켈-티타늄 기구의 근관 중심율 유지 능력 (The instrument-centering ability of four Nickel-Titanium instruments in simulated curved root canals)

  • 구재훈;장훈상;장석우;조환희;배지명;민경산
    • Restorative Dentistry and Endodontics
    • /
    • 제31권2호
    • /
    • pp.113-118
    • /
    • 2006
  • 본 연구의 목적은 새로 시판된 NRT 기구의 근관 형태 유지 능력을 기존의 3종의 기구와 비교하는 것이다. 만곡된 레진 모형 근관을 ProFile, K3, ProTaper, NRT 기구를 이용하여 형성하였고 형성 전, 후의 상을 스캔한 후 중첩시켜 이미지 분석 프로그램을 이용하여 근관 만곡도의 변화와 근관 중심축에 대한 근관의 변이 정도를 근관 중심율의 변화로 계산하여 분석하였다. 근관 변이의 유의성 검정을 위해 one-way ANOVA분석을 시행하였으며 각 기구간의 유의성 검정은 Duncan's test로 사후 분석하였다. 근첨에서 1, 2 mm 상방 위치에서의 근관 중심율은 ProFile 군이 다른 군에 비해 우수한 것으로 나타났다. (p < 0.05). NRT기구의 근관 중심율 변화를 측정한 결과 근첨으로부터 5 mm 상방에서는 Profile에 비해서만 큰 것으로 나타났고 6, 7 mm 상방에서는 다른 모든 군들에 비해 큰 것으로 나타났다 (p < 0.05). 비록 NRT기구가 근첨 부위에서는 ProFile을 제외한 다른 기구에 비해 유의차 없는 중심률 유지 능력을 보였으나 근관 입구 및 중간부위의 형성에 사용되는 스테인레스-스틸 파일로 인해 coronal flaring시 다른 기구들에 비해 더 많은 중심률의 변화를 보이는 것으로 사료된다.

GT rotary file을 이용한 만곡 근관형성시 작업 효율 및 file 변형 발생에 관한 연구 (A STUDY OF WORKING EFFICIENCY AND FILE DEFORMATION OF GT ROTARY FILE IN CURVED CANALS)

  • 신주희;백승호;배광식;임성삼;윤수한;김병현
    • Restorative Dentistry and Endodontics
    • /
    • 제26권5호
    • /
    • pp.418-435
    • /
    • 2001
  • Root canal preparation process is of utmost importance in successful treatment of root canal. Also, one of the most important purpose of the root canal preparation is to enlarge the root canal three dimensionally without changing the curvature of the root canal However as the curvature of the root canal increases, there are many difficulties involved in formation of optimum root canal. Therefore in order to solve the above mentioned problems, new developments in methods of root canal preparation and equipments for such purposes were made. Recently, vigorous studies about newly introduced engine-driven nickel-ti-tanium rotary file are conducted. As shown in research results to dates, it is well established that the use of nickel-titanium file is better suited for curved root canal than stainless steel file in maintaining the curvature or root canal and reducing the deformation of root canal. However it is also acknowledged that there are a few discrepancies in research results according to protocol, due to failure to remove variables in experiments. In addition, although it is recommended by the manufacturer that the GT rotary file should maintain a low rotational speed of 150~350rpm and 'light pressure' as light as not to break the lead of a pencil, academic studies about the vertical force which is not yet standardized are not sufficiently explored. Therefore, this research devised and utilized a special research equipment to standardize the appropriate range of vertical force for GT rotary file through experiments by breaking of the lead of a pencil as expressed by the manufacturer and to accurately measure factors involved through repeating and recreating the environment of root canal preparation. Forming nine experimental groups by varying the vertical forces (150g. 220g, 300g) and rpm (150rpm, 250rpm, 350rpm), the effects of changing vertical forces and rpm on working efficiency were measured in terms of time expended in root canal preparation by crown-down method using a transparent resin block with 35 degree curvature and GT rotary file (z-test). The following research using this special research equipment that involved nine experimental groups and varying the vertical force for root canal preparation from 300g which is within the normal vertical force range to 700g and 1000g which fall outside the normal rpm range. The results were as follows : 1. Analysis of the experiment results revealed that the time spent in root canal preparation decreased as the vertical forces and rpm increased (p<0.05). Also, the effects of rpm were greater than those of the vertical forces within the normal vertical force range ($\beta$-weight test). 2. Observation of the deformation of GT rotary file revealed that deformation increases in a direct correlation with the vertical force increase and in a reverse correlation with the rpm decrease. In the case of the vertical forces close to the normal range, the probability of GT rotary file deformation were quite different depending on the rpm changes. In the case of greater vertical forces, the occurrences of deformation of the file were more frequent regardless of the rpm changes. 3. Deformation and breakage of file were also commonly observed in the expended time measurement experiments and GT rotary file deformation experiments in which low speed rpm (150rpm) was used and at the curved portion of the resin block.

  • PDF

만곡 근관에서 다양한 엔진 구동형 Nickel-Titanium 파일의 근관 성형능력에 대한 연구 (A Study on the Shaping Ability of Three Different Rotary Nickel-Titanium Instruments in Simulated Curved Root Canal)

  • 김경아;전성민;권수미;이광원;유미경
    • 구강회복응용과학지
    • /
    • 제23권4호
    • /
    • pp.293-302
    • /
    • 2007
  • I. Objectives The purpose of this study was to compare the shaping ability between the single length technique performed with Mtwo instruments (VDW, Munich, Germany) and the crown-down technique using K3 (SybronEndo, West Collins, CA, USA) and RaCe (FKG, La Chaux-de-Fonds, Switzerland) instruments. II. Materials & Methods Forty five curved canals in resin blocks were equally divided in to three groups. Group 1 (Mtwo) was instrumented used the full length of canal according to the manufacturer's instructions. The simulated canals was prepared to an instrument size of 35, 0.04 taper canal terminus. In group 2 (Race) and group 3 (K3) was instrumented in a crown-down manner and prepared to an instrument size of 30, 0.06 taper canal terminus. Pre- and post-instrumentation images were scanned and assessment of canal shape was completed with a computer image analysis program. Material removal was measured at 7 measuring points, beginning 1mm from the end point of preparation. Differenced of centering ratio were statistically analyzed using One-way ANOVA followed by Duncan's test. II. Results & Conclusion There was no significant difference on 1, 2, 3 and 7mm measuring point. At 4 and 5 measuring point, significant difference showed between the Mtow instruments and other two instruments. (p<0.05)

0.06-경사도의 니켈-티타늄 기구로 형성된 레진 만곡근관에서 비표준화 GUTTA-PERCHA CONE의 근관충전 효율 (Obturation efficiency of non-standardized gutta-percha cone in curved root canals prepared with 0.06 taper nickel-titanium instruments)

  • 이은아;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제30권2호
    • /
    • pp.79-85
    • /
    • 2005
  • 최근, 다양한 경사도의 니켈-티타늄 근관기구와 더불어 다양한 경사도의 gutta-percha cone이 소개되었다. 효율적인 근관 충전을 위해서는 짧은 시간에 적은 수의 기구 및 재료를 사용하여 균일한 gutta-percha로 근관을 충전할 필요가 있다. 본 연구에서는 0.06 경사도의 니켈-티타늄 전동화일로 형성된 만곡 근관에서 측방 가압법으로 근관충전시 비표준화 medium 크기 master gutta-percha cone의 충전효율을 ISO 표준화 규격의 master cone과 비교하여 평가하고자 하였다. 60개의 모형레진 만곡근관에서 0.06 경사도의 니켈-티타늄 전동화일 ($ProTaper^{TM},\;ProFile^{(R)}$, Dentsply-Maillefer, Ballaigues, Switzerland)을 사용하여 근단부 근관이 30번 크기가 되게 crown-down법으로 근관을 형성하였다. 근관은 master gutta-percha cone, AH 26 실러 (Dentsply-DeTrey, Konstanz, Germany), 그리고 type A accessory cone (Dentsply-Maillefer, Ballaigues, Switzerland)을 사용하여 측방가압법으로 충전하였으며, 이 때 사용된 master gutta-percha cone(Diadent, Chongju, Korea)과 Finger spreader(B type, Dentsply-Maillefer, Ballaigues, Switzerland)에 따라 임의로 15개씩 4개의 군으로 나누어 실험하였는데, St/SS 군에서는 ISO 표준화 규격의 30번 master cone과 스테인레스 스틸 finger spreader를, St/NT 군에서는 ISO 표준화 규격의 30번 master cone과 니켈-티타늄 finger spreader를, Non-St/SS 군에서는 비표준화 medium 규격 master cone과 스테인레스 스틸 spreader를, 그리고 Non-St/NT 군에서는 비표준화 medium 크기 master cone과 니켈-티타늄 finger spreader를 각각 사용하였다. 충전된 근관은 $37^{\circ}C$, 상대습도 $100\%$하에서 24시간 보관한 후, 치근단 1, 3및 5 mm수준에서 횡절단하여 입체현미경 하에서 관찰하고 컴퓨터에 저장한 다음, $Auto^{(R)}$CAD 2000 프로그램을 이용하여, 형성된 근관 및 gutta-percha 충전물의 외형을 추적하여 근관내 gutta-percha 면적비를 계산하였다. Gutta-percha 면적비의 결과치는 two-way ANOVA를, 그리고 accessory cone 수는 one-way ANOVA 및 Duncan's multiple range test를 이용하여 통계 분석하여 다음과 같은 결과를 얻었다. 스테인레스 스틸 finger spreader를 사용한 경우 및 니켈-티타늄 finger spreader를 사용한 경우 공히, 모든 치근단 수준에서 비표준화 medium 크기 master cone 사용군이 ISO 표준화 규격의 master cone 사용군에 비해 유의하게 높은 gutta-percha 면적비를 나타내었다 (p < 0.01). 비표준화 medium크기 master cone 사용군에서는 표준화 규격의 master cone 사용군에 비해 유의하게 적은 수의 accessory cone이 사용되었다 (p < 0.01).

만곡근관의 확대시 기구에 따른 형태변화에 관한 연구 (TRANSPORTATION OF CURVED CANAL AFTER CANAL ENLARGEMENT ACCORDING TO FILING INSTRUMENTS)

  • 이석종;신영근;황호길
    • Restorative Dentistry and Endodontics
    • /
    • 제24권3호
    • /
    • pp.503-510
    • /
    • 1999
  • The purpose of this study was to evaluate the amount of transportation of original canal, zip formation, permanent deformation and fracture of instruments after canal enlargement. In this study, the 60 resin blocks that have curved canals were randomly divided into 3 experimental groups with 20 teeth each according to instrument types and filling methods for canal enlargement. The curved canals of each experimental groups were enlarged to No 40 ISO size with the K-flexo stainless steel file (Group 1), Engine-driven Ni-Ti Profile new series(Group 2) and Engine-driven Ni-Ti Quantec 2000 series(Group 3) according to the manufacturer's recommendation. Pre- and postoperative X-rays were taken at same position and the films were scanned and the canal images were traced to determine the canal curvature according to the method of Schneider. The amount of reduction in canal curvature were calculated between pre- and postoperative X-rays. In addition to zip formation, permanent deformation and fracture of instruments were examined after canal enlargement. The results were as follows : 1. All experimental groups showed some loss of canal curvature after instrumentation. There was a significant change in curvature between before and after instrumentation in each group(p<0.001). 2. Engine-driven Ni-Ti instrumentations resulted in an average loss of curvature of 2.36 degrees for Profile new series, 3.43 degrees for Quantec series, and hand instrumentation showed an average loss of curvature of 6.48 degrees for K-flexo file. There was a statistical significant difference between hand instrumentation and engine-driven Ni-Ti instrumentations(p<0.05). But there was no statistical difference between Profile new series and Quantec series. 3. There were many apical zip formations in group 1(Hand instrumentation). But there were no apical zip formations in group 2,3(Engine-driven Ni-Ti instrumentation). 4. The instrument deformation occured 9 cases in group 1(K-flexo file), 2 cases in group 2(Profile new series) and 3 cases in group 3(Quantec) after instrumentation. And the instrument fracture occured 1 case in each group. The results showed that the engine-driven Ni-Ti instruments, if we use carefully according to manufacturer's recommendations, can be use effectively for instrumenting the curved root canals in case of the MAF was over size 40.

  • PDF

전동화일로 형성된 근관에서 비표준화 Gutta-percha Cone의 적합성 (APICAL FITNESS OF NON-STANDARDIZED GUTTA-PERCHA CONES IN SIMULATED ROOT CANALS PREPARED WITH ROTARY ROOT CANAL INSTRUMENTS)

  • 권오상;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제25권3호
    • /
    • pp.390-398
    • /
    • 2000
  • 근관형성을 위해 표준화된 근관형성기구에 비해 taper가 큰 기구들이 사용되고 있으며 이를 이용하여 형성된 근관은 taper가 큰 근관의 모양을 갖는다. 근관충전방법에 있어 근관의 크기에 적합한 1차적 gutta-percha cone을 선택할 필요가 있다. 본 연구에서는 .04 및 .06 taper의 전동화일로 형성된 근관에 열연화충전법을 위해 가장 적합한 1차 cone을 선택하기 위한 지침 마련의 목적으로, 근단공의 크기와 근관의 taper에 따른 gutta-percha cone의 근단부 근관 내 적 합도를 평가하였다. ProFile$^{(R)}$ .04 taper와 .06 taper를 이용하여 Crown down 방법으로 60개의 모형근관을 형성하였다. 표준화 gutta-percha cone, Dia-Pro ISO-.04$^{TM}$ 및 .06 gutta-percha cone, MF, F, FM 및 M 크기의 비표준화 gutta-percha cone의 근관 내 적합도는 치근단 5mm의 근관면적에 대한 gutta-percha cone의 점유 면적비(%)로 하였다. .04 taper, 25번 크기의 근관에서는 F, MF 크기의 비표준화 cone이 표준화 cone과 Dia-Pro 180-.04$^{TM}$ 보다 우수한 근관적합도를 나타내었고(p<0.05), 30번 크기의 근관에서는 F, Dia-Pro ISO-.04$^{TM}$, FM 크기의 gutta-percha cone 모두 표준화 cone보다 우수한 근관적합도를 나타내었으나(p<0.05), 35번 크기의 근관에서는 모든 gutta-percha cone 사이에 유의한 차이를 나타내지 않았다(p>0.05) .06 taper, 25번 크기의 근관에서는 사용된 비표준화 cone 모두가 표준화 cone, Dia-Pro ISO-.06$^{TM}$ 보다 나은 근관적합도를 나타내었고(P<0.05), 30번 크기의 근관에서는 표준화 cone을 제외한 나머지 gutta-percha cone에서 유의한 차이를 발견할 수 없었다. 35번 크기의 근관에는 M 크기의 비표준화 cone이 가장 우수한 근관적합도를 보이고 있는 것으로 나타났으며, FM과 Dia-Pro ISO-.06$^{TM}$ 사이에서는 유의한 차이가 나타나지 않았다(p>0.05).

  • PDF