• 제목/요약/키워드: Curved root canals

검색결과 57건 처리시간 0.022초

A comparison of shaping ability of four nickel-titanium rotary instruments in simulated root canals

  • Yun, Hyung-Hwa;Park, Jung-Won;Kim, Sung-Kyo
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.588.1-588
    • /
    • 2001
  • The purpose of this study was to compare the root canal shaping ability of four nickel-titanium rotary instruments. Forty eight simulated curved root canals were instrumented in plastic with the Crown-down technique using the $ProTaper^{TM}$ , the ProFile, the $GT^{TM}$, and the Quantec. Canals were instrumented until apical canal were up to size 30 by one operator. Each instrument was used only once and instrumentation time was measured.(omitted)

  • PDF

Comparison of canal transportation in simulated curved canals prepared with ProTaper Universal and ProTaper Gold systems

  • Silva, Emmanuel Joao Nogueira Leal;Muniz, Brenda Leite;Pires, Frederico;Belladonna, Felipe Goncalves;Neves, Aline Almeida;Souza, Erick Miranda;De-Deus, Gustavo
    • Restorative Dentistry and Endodontics
    • /
    • 제41권1호
    • /
    • pp.1-5
    • /
    • 2016
  • Objectives: The purpose of this study was to assess the ability of ProTaper Gold (PTG, Dentsply Maillefer) in maintaining the original profile of root canal anatomy. For that, ProTaper Universal (PTU, Dentsply Maillefer) was used as reference techniques for comparison. Materials and Methods: Twenty simulated curved canals manufactured in clear resin blocks were randomly assigned to 2 groups (n = 10) according to the system used for canal instrumentation: PTU and PTG groups, upto F2 files (25/0.08). Color stereomicroscopic images from each block were taken exactly at the same position before and after instrumentation. All image processing and data analysis were performed with an open source program (FIJI). Evaluation of canal transportation was obtained for two independent canal regions: straight and curved levels. Student's t test was used with a cut-off for significance set at ${\alpha}=5%$. Results: Instrumentation systems significantly influenced canal transportation (p < 0.0001). A significant interaction between instrumentation system and root canal level (p < 0.0001) was found. PTU and PTG systems produced similar canal transportation at the straight part, while PTG system resulted in lower canal transportation than PTU system at the curved part. Canal transportation was higher at the curved canal portion (p < 0.0001). Conclusions: PTG system produced overall less canal transportation in the curved portion when compared to PTU system.

수종의 Engine driven NiTi file과 stainless steel K-file을 이용한 근관형성 후 근관의 조직형태학적 변화에 관한 연구 (A STUDY OF HISTOMORPHOLOGICAL CHANGE OF CURVED ROOT CANAL PREPARATION USING GT ROTARY FILE, PROFILE AND STAINLESS STEEL K-FILE)

  • 고현정;백승호
    • Restorative Dentistry and Endodontics
    • /
    • 제27권6호
    • /
    • pp.612-621
    • /
    • 2002
  • The purpose of this study was to compare the histomorphological change of curved root canal preparation using GT rotary File, Profile .04 taper and stainless steel K-file. 45 mesial canals(over 20 degree) of extracted human mandibular first molars were mounted in resin using a modified Bramante muffle system and divided into three groups. The roots were cross-sectioned at 2.5mm 5mm and 8mm levels from apical foramen. Tracings of the canals were made from preinstrumentation pictures of the cross section. The canals were prepared using a step-back technique with stainless steel K file(group 1), Profile .04 taper rotary file(group 2) and GT rotary file(group 3). Tracings of the prepared canals were made from postinstrumentation picture. Canal centring ratio. amount of transportation, area of dentin removed and shape of canal were measured and statistically were evaluated with Student-Newman-Keuls test using Sigma Stat(Jandel Scientific Software, USA). The results were as followings : 1 Amount of transportation of group 2 was the lowest at apical part, but there was no statistical difference. The direction of transportation was the outside of curvature at apical part. 2. Centering ratio at the apical part of group 1 was the highest, and there was statistical differences between apical and middle part, apical and coronal part(p<0.05). Centering ratio at the middle part of group 3 was the lowest, and there was statistical difference between apical and middle part(p<0.05). Centering ratio of group 2 was the lowest at apical part, but there was no statistical difference. 3. Amount of dentin removed of group 1 was the highest at coronal, middle and apical part among three groups, and there was statistical difference(p<0.05). 4. The majority of the cross-sectioned canal shape after instrumentation were irregular at coronal, middle and apical part. But there are more number of round shaped canals at group 3 than other group.

A comparison of the shaping ability of reciprocating NiTi instruments in simulated curved canals

  • Yoo, Young-Sil;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • 제37권4호
    • /
    • pp.220-227
    • /
    • 2012
  • Objectives: The study was to compare the shaping ability of Reciproc (VDW) and WaveOne (Dentsply Maillefer) instruments compared with ProTaper, Profile and hand instrument during the preparation of simulated root canals. Materials and Methods: Five groups (n = 5) were established. Reciproc, WaveOne, ProTaper, Profile and K file (K-flexo file) were used to prepare the resin simulated canals. A series of preoperative and postoperative images were taken by a microscope and superimposed in 2 different layers. The amount of resin removed from both the inner and the outer sides of the canal was measured to the level of 10 mm from the apical tip, with a 1 mm increment. Results: The mean of resin removal from the inner canal wall was not different from the outer canal wall for Reciproc and WaveOne groups at apical third (1 - 3 mm level). There was no difference in the change of working length and maintenance of canal curvature. NiTi instruments are superior to stainless-steel K file in their shaping ability. Conclusions: Within the limitation of this present study, Reciproc and WaveOne instruments maintained the original canal curvature in curved canals better than ProTaper and Profile, which tend to transport towards the outer canal wall of the curve in the apical part of the canal.

만곡된 근관에서 Gutta-Percha 제거 시 스테인리스스틸 수기구와 회전식 NiTi 재치료용 기구의 효과 비교 (A Comparison of the Effectiveness of Stainless-Steel Hand Instrument and Rotary NiTi Retreatment Instrument to Remove Gutta-Percha in Curved Root Canals)

  • 남동구;김민정;조혜진;이광원;유미경
    • 구강회복응용과학지
    • /
    • 제27권1호
    • /
    • pp.99-107
    • /
    • 2011
  • 비외과적 재근관치료의 주된 목표는 치근주변의 치유를 위하여 근관 공간을 완전히 멸균하는 것이며, 이 목표를 달성하기 위해서는 이전 충전물질의 완전한 제거가 요구된다. 전통적으로 근관충전물질의 제거는 스테인리스스틸 수기구를 통해서 이루어져 왔으며 이는 시간과 노력이 많이 소요되는 작업이다. 최근 보다 효율적인 근관충전물질의 제거를 위해 재치료용 회전식 NiTi 기구가 소개되었다. 이 연구에서는 만곡된 근관에서의 스테인리스스틸 수기구, ProTaper Universal Retreatment (Dentsply Maillefer, Ballaigues, Switzerland), Mtwo retreatment (Sweden & Martina, Padova, Italy)의 gutta-percha 제거 효율을 비교하였다. 재치료 후 근관 내 남겨진 gutta-percha의 양은 실험군 사이에 유의한 차이가 발견되지 않았다. 하지만 재치료에 소요된 시간은 재치료용 회전식 NiTi 기구를 이용한 실험군에서 더 적게 소요되는 것으로 나타났다.

Characterization of mandibular molar root and canal morphology using cone beam computed tomography and its variability in Belgian and Chilean population samples

  • Torres, Andres;Jacobs, Reinhilde;Lambrechts, Paul;Brizuela, Claudia;Cabrera, Carolina;Concha, Guillermo;Pedemonte, Maria Eugenia
    • Imaging Science in Dentistry
    • /
    • 제45권2호
    • /
    • pp.95-101
    • /
    • 2015
  • Purpose: This study used cone-beam computed tomography (CBCT) to characterize mandibular molar root and canal morphology and its variability in Belgian and Chilean population samples. Materials and Methods: We analyzed the CBCT images of 515 mandibular molars (257 from Belgium and 258 from Chile). Molars meeting the inclusion criteria were analyzed to determine (1) the number of roots; (2) the root canal configuration; (3) the presence of a curved canal in the cross-sectional image of the distal root in the mandibular first molar and (4) the presence of a C-shaped canal in the second mandibular molar. A descriptive analysis was performed. The association between national origin and the presence of a curved or C-shaped canal was evaluated using the chi-squared test. Results: The most common configurations in the mesial root of both molars were type V and type III. In the distal root, type I canal configuration was the most common. Curvature in the cross-sectional image was found in 25% of the distal canals of the mandibular first molars in the Belgian population, compared to 11% in the Chilean population. The prevalence of C-shaped canals was 10% or less in both populations. Conclusion: In cases of unclear or complex root and canal morphology in the mandibular molars, CBCT imaging might assist endodontic specialists in making an accurate diagnosis and in treatment planning.

측방가압충전시 Nickel-Titanium spreader의 사용유무가 근관충전효과에 마치는 영향 (INFLUENCE OF NICKEL-TITANIUM SPREADER ON THE SEALING ABILITY IN LATERAL CONDENSATION TECHNIQUE)

  • 민경산;홍찬의;조용범
    • Restorative Dentistry and Endodontics
    • /
    • 제25권3호
    • /
    • pp.381-389
    • /
    • 2000
  • Lateral condensation with gutta-percha and sealer has been shown to provide an excellent apical seal; however, the lateral condensation technique has demonstrated less favorable apical leakage results in curved canals when compared with straight canals. Placement of endodontic spreaders to within 1 to 2mm of the root canal working length has been advocated for optimum gutta-percha obturation. Due to their stiffness, stainless-steel(SS) spreaders will often fail to achieve this position in curved canals. Newly marketed nickel-titanium(NT) spreaders may offer an advantage in this regard due to the increased flexibility of these instruments. The purpose of this study was to evaluate the effect of NT finger spreader on the sealing ability in lateral condensation technique, compared with conventional SS finger spreader. Twenty four standardized resin models simulating curved canals(30 degree) were randomly placed into 2 groups and instrumented to a #30 master apical file size with Ni-Ti Profile .04 taper series using step down technique. Each groups was obturated with standardized gutta-percha cone by standard lateral condensation technique using SS finger spreader, NT finger spreader. And then, each model was sectioned horizontally with microtome at 1, 2, 3, 4, 5mm levels from the apex. At each of 5 levels, ratio of the area of gutta-percha was obtained by calculating the area of gutta-percha to the total area of the canal. The data collected were then analyzed statistically using a t test for independent samples. The results as follows ; 1. The total mean ratio of area of gutta-percha was 89.20${\pm}$7.00(%) for SS spreader group. 92.20${\pm}$5.17(%) for NT spreader group. There was statistically significant difference between each group(p<0.05). 2. At 3mm level, the mean ratio of area of gutta-percha was 88.32${\pm}$5.41(%) for SS spreader group, 95.25${\pm}$2.60(%) for NT spreader group. There was statistically significant difference between each group(p<0.05). At 1,2,4mm levels, NT spreader group showed greater mean ratio of area of gutta-percha than SS spreader group, too. But there was no statistically significant difference. 3. At 5mm level, the mean ratio of area of gutta-percha was 91.83${\pm}$3.42(%) for SS spreader group, 87.91${\pm}$3.68(%) for NT spreader group. There was statistically significant difference between each group(p<0.05). This study concluded that the NT spreader demonstrated somewhat favorable apical sealing effect than SS spreader in prepared curved canals. The clinical use of NT spreaders may enhance our ability to create better apical seals in curved canals, but further studies in this area will help clarify some of the remaining areas with which practitioners are concerned, such as compaction forces exerted by NT spreaders.

  • PDF

CBCT를 이용한 유구치의 치근 및 근관의 형태학적 평가 (Assessment of Root and Root Canal Morphology of Human Primary Molars using CBCT)

  • 최유민;김선미;최남기
    • 대한소아치과학회지
    • /
    • 제47권1호
    • /
    • pp.25-35
    • /
    • 2020
  • 이 연구의 목적은 CBCT를 사용하여 유구치 치근 및 근관의 형태학적 특징을 평가하는 것이다. 과잉치 발거를 위해 전남대학교 치과병원 소아치과에 내원하여 CBCT를 촬영한 만 4 - 5세 환자 총 68명의 영상으로 연구를 진행하였다. 치근 흡수가 되지 않은 상악 제1유구치, 상악 제2유구치, 하악 제1유구치, 하악 제2유구치로 구분하여 분석하였다. 치근 및 근관의 수, 치근 및 근관의 길이와 각도 등의 다양한 변수들이 분석되었다. 상악 유구치는 모두 3개의 치근을 가졌고 원심 협측 치근과 구개 치근은 단일 근관을 가졌다. 한 치근에 2개의 근관이 있는 경우는 오직 상악 제2유구치의 근심 협측 치근에서 발견되었다. 하악 유구치는 대부분 근심과 원심 2개의 치근을 가졌다. 하악의 근심 치근은 대부분 2개의 근관을 가졌다. 치근의 길이와 관련하여, 상악의 구개 치근의 길이가 가장 긴 반면, 원심 협측 치근의 길이는 가장 짧은 것으로 밝혀졌다. 하악 유구치는 근심의 치근이 더 길었다. 상악 유구치에서는 구개 치근의 각도가 가장 컸으나 하악은 근심의 각도가 더 작았다. 상악 유구치의 치근 및 근관이 곡선형이 많은 반면 하악 유구치는 직선형을 더 많이 볼 수 있었다.

Endodontic treatment of mandibular molar with root dilaceration using Reciproc single-file system

  • Meireles, Daniely Amorin;Bastos, Mariana Mena Barreto;Marques, Andre Augusto Franco;Garcia, Lucas Da Fonseca Roberti;Sponchiado, Emilio Carlos Junior
    • Restorative Dentistry and Endodontics
    • /
    • 제38권3호
    • /
    • pp.167-171
    • /
    • 2013
  • Biomechanical preparation of root canals with accentuated curvature is challenging. New rotatory systems, such as Reciproc, require a shorter period of time to prepare curved canals, and became a viable alternative for endodontic treatment of teeth with root dilaceration. Thus, this study aimed to report a clinical case of endodontic therapy of root with accentuated dilaceration using Reciproc single-file system. Mandibular right second molar was diagnosed as asymptomatic irreversible pulpitis. Pulp chamber access was performed, and glide path was created with #10 K-file (Dentsply Maillefer) and PathFile #13, #16 and #19 (Dentsply Maillefer) up to the temporary working length. The working length measured corresponded to 20 mm in the mesio-buccal and mesio-lingual canals, and 22 mm in the distal canal. The R25 file (VDW GmbH) was used in all the canals for instrumentation and final preparation, followed by filling with Reciproc gutta-percha cones (VDW GmbH) and AH Plus sealer (Dentsply Maillefer), using thermal compaction technique. The case has been receiving follow-up for 6 mon and no painful symptomatology or periapical lesions have been found. Despite the difficulties, the treatment could be performed in a shorter period of time than the conventional methods.

NiTi Rotary Instruments에 의한 근관형성이 치근단부 근관형태에 미치는 영향 (THE EFFECT OF NITI ROTARY INSTRUMENTATION ON THE CONFIGURATION OF APICAL ROOT CANAL)

  • 오현정;홍찬의;조용범
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.244-253
    • /
    • 1997
  • During preparation of narrow curved canals, procedural accidents such as, ledge, zipping, and transportation are frequently encountered and may lead to failure of endodontic therapy. To reduce these procedural errors and efficiently manage curved canals, various modifications in instrumentation technique and the design and flexibility of instruments have been advocated. This study compared the maintenance of the original canal curvature, cross sectional canal shape, and preparation time during instrumentation with stainless steel hand (K-Flexo) file, and nickel-titanium rotary files (Profile and Lightspeed). Thirty resin blocks with simulated curved canals of 20~25 degrees were used and divided into three groups of 10 each. In group 1, canals were instrumented using a quarter turn/pull technique with K-Flexofiles. Group 2 canals were prepared with rotary NiTi Profiles. Group 3 was prepared with rotary NiTi Lightspeed instrument. Before and after instrumentation, all canals were scanned using stereo microcope, FlexCam camera, and Photoshop 3.0 computer program. The results were as follows : 1. All groups showed some loss of canal curvature after instrumentation. Average loss of canal curvature was 8.6 degrees for K-Flexofile, 7.7 degrees for Profile, and 5.8 degrees for Lightspeed. Lightspeed exhibited significantly less curvature loss than K-Flexofile (p<0.05). 2. At the apical 1-mm level, Profile produced significantly rounder canals than Lightspeed (p<0.05). At the 3-mm level, Profile and Lightspeed exhibited significantly rounder canals than K-Flexofile (p<0.05). 3. Preparation with Lightspeed was significantly faster than Profile and K-Flexofile, and Profile was faster than K-Flexofile (p<0.05). 4. There was no significant difference in incidence of zipping between the hand K-Flexofile and rotary NiTi (Profile and Lightspeed) instruments. Most of apical canals were slightly widened near the apical foramen. As a results of this study, rotary NiTi instruments are superior to the K-Flexofile in regard to the maintenance of original canal curvature, cross-sectional shape and preparation time. But more investigations and studies should be needed to evaluate the ideal canal instrumentation.

  • PDF