• Title/Summary/Keyword: Curved probe

Search Result 16, Processing Time 0.02 seconds

The Application of Electron Microprobe Analysis in Geological Science (EPMA의 지질학(地質學)에의 응용(應用))

  • Sang, Ki Nam
    • Economic and Environmental Geology
    • /
    • v.17 no.4
    • /
    • pp.315-320
    • /
    • 1984
  • The newly discovered minerals found during 30 years have been discovered with election microprobe analysis, and several other new minerals have been described largely on the basis of probe analysis. Widely used types of instrument are the wavelength dispersive spectrometer (WDS) and the energy dispersive Spectrometer (EDS), with emitted X-ray dispersed by a curved crystal that is arranged to satisfy the Bragg equation ($n{\lambda}=2dsin{\theta}$). Atomic Nos of Z 4 to 92 can be analyzed quantitatively if they present in amount exceeding 50~100ppm. The application of the microprobe in mineralogical and geological research is quantitative chemical analysis of grains as small as a few microns in diameter, individual grains in a rock or can be analyzed in thin section and polished section, analysis can be made comparatively short time, methods in non-destructure, to photographical and crystallographical information. This paper was written in order to document data evaluation procedure for quantitative energy dispersive election probe analysis.

  • PDF

The cover of an ear thermometer probe as a split-thickness skin graft mold in external auditory canal reconstruction

  • Chae Rim Lee;Sungyeon Yoon;Ji Hun Kim;Jangyoun Choi;Kyoung Ho Park;Deuk Young Oh
    • Archives of Craniofacial Surgery
    • /
    • v.24 no.4
    • /
    • pp.198-201
    • /
    • 2023
  • Maintaining the patency of the external auditory canal (EAC) during reconstruction is important because of its physiological role in hearing and immunological protective functions. The curved shape of the EAC presents a challenge when performing a skin graft. One of the key points for a successful skin graft is to ensure compression on the wound bed, and many novel methods, including prefabricated ear molds, have been reported for this purpose. In this study, we present a case of a skin graft performed to reconstruct a skin defect following excision of actinic keratosis in the EAC, using the cover of an ear thermometer probe as a mold for the graft to match the curvature of the EAC. This is an economical and practical method for secure compression dressing of a skin graft in the EAC.

Characteristics of Sound Response in Ear Canal of Human and Reproduction of Acoustical Space (인간 이도의 소리응답특성과 음향공간의 재현)

  • Ahn, Tae-Soo;Lee, Doo-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.9
    • /
    • pp.842-849
    • /
    • 2011
  • The human ear canal amplifies the sound pressure level at specific frequency bands. The characteristics of the ear canal are very similar to those of curved cylindrical tube. In this study, the characteristics of sound transfer in human ear canal were measured and the acoustical space of ear canal was reproduced from the canal cavity geometry. For the measurement of sound transfer function in ear canal, a probe microphone and a reference microphone were used. The sound transfer functions were measured for 5 human subjects. To reproduce the acoustical space of the ear canal, two kinds of ear simulator were designed. The first one is a straight cylindrical tube type and the other is a real-shape ear of which geometry was taken from a micro-CT scanning of a human ear. The characteristics of the reproduced apparatus were compared with those of the human and a commercial ear simulator, RA0045 of G.R.A.S. Inc. The comparison results show that the developed apparatus well represent the ear canal characteristics in the low frequency, but have limited coincidence in level over high frequency range.

Velocity Measurement Technique in a Narrow Passage by Hot-wire Anemometer (열선유속계를 이용한 좁은 유로 내 유속 측정법)

  • Kim, Won-Kap;Han, Seong-Ho;Choi, Young-Don
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.2
    • /
    • pp.191-201
    • /
    • 2007
  • It was noted by the several researchers that the voltage outputs in response to a single yawed hot-wire sensor in a flow perpendicular to the axis deviate from the theoretical voltage output by King's law and Jorgensen's relation. This study noticed that the calibration coefficients of original Grande's method are not constant and fairly sensitive to the radial angle (${\alpha}_{R}$). For more accuracy, this study interpolated the parameters of the Grande relation as a function of radial angle and compared velocity components with ones by Jorgensen and original Grande relation in the calibration jet flow. Finally, as a test case, 3-dimensional turbulent flows of the inlet plane of 180 degree bend are measured and compared the velocity components by above three methods and showed the characteristics of the flows.

Effect of Cu-Additions on the Hand-Over Layer of an Aluminum Alloy - Hardening for the Top Ring Groove of Automotive Piston by the Plasma Transferred Arc Welding Process -

  • Moon, J.H.;Seo, C.J.;Hwang, S.H.
    • International Journal of Korean Welding Society
    • /
    • v.1 no.1
    • /
    • pp.58-62
    • /
    • 2001
  • The surface of AC8A Ah alloy was modified by adding the Cu powder using a Plasma Transferred Arc (PTA) welding process. Under the optimum fabricating conditions, the modified surface of AC8A Ah alloy was observed to possess the sound microstructure with a minimum porosity. Hardness and wear resistance properties of the as-fabricated alloy were compared with those of the 76 heat-treated one. In case of the as-fabricated alloy, the hardness of the modified layer was twice that of the matrix region. Although significant increase in the hardness of the matrix region was observed after T6 heat treatment, the hardness of the modified layer was not observed to change. The wear resistance of the modified layer was significantly increased compared to that of the matrix region. The microstructure of a weld zone and the matrix region were investigated using the optical microscope, scanning electron microscope (SEM), electron probe microanalysis (EPMA), and transmission electron microscope (TEM). The primary and eutectic silicon in the weld zone were finer and more curved than in the matrix region, while some precipitates has had been found therein. According to the TEM observation, the predominant precipitate present in the weld zone was the $\theta$'phase, which is precipitated during cooling by rapid solidification in PTA welding process. Improvement of hardness and wear properties in the weld zone in the as-fabricated condition can be explained based on the presence of $\theta$’precipitates and fine primary and eutectic silicon distribution.

  • PDF

THE IRRIGATING EFFECT BEFORE AND AFTER CORONAL FLARING (Coronal flaring 전, 후의 근관세척효과)

  • Hwang, Ho-Keel;Bae, Seong-Chul;Cho, Young-Lin
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.1
    • /
    • pp.72-79
    • /
    • 2003
  • The objective of this in vitro study was to evaluate the efficacy of a Ca(OH)$_2$removal before and after early coronal flaring using different types of instruments. 100 plastic blocks with 30$^{\circ}$artificial curved canals were used in this study and randomly divided into a control group and 4 experimental groups(GG, OS, GT, PT Group) 20 teeth each. The canals were instrumented, and Ca(OH)$_2$was temporary filled into the each canal. Irrigation was peformed with Max-i-Probe 25- 30-gauge probes before and after recapitulation. The results of this study were as follows 1. There were no significant difference among the groups in size of irrigating needle(p<0.05). 2. There was a significant difference between before and after recapitulation regardless size of irrigating needle(p<0.05). 3. Before recapitulation, there was a significant difference between 25- and 30-gauge needle in all groups(P<0.05). 4. After recapitulation, there was a significant difference between 25- and 30-gauge needle in the control group(p<0.05). But there were no significant difference among the experimental groups. It is concluded that the effectiveness of canal irrigation was decided to the depth of irrigating needle into the canal. The effect of canal irrigation tend to facilitate by the early coronal flaring. The recapitulation was the most effective during canal irrigation regardless the size of irrigating needle. Therefore, the recapitulation is a mandatory way to facilitate the effectiveness of canal irrigation during canal enlargement.