Kim, Young-Sang;Nho, Seung-Gu;Choi, Jong-Moon;Choi, Hee-Seon
Analytical Science and Technology
/
v.6
no.3
/
pp.289-296
/
1993
The formation of Mo(VI)-alizarin red S chelate ion and its extraction into an organic solvent by ion-pairing were studied for the separative determination of trace Mo(VI) in natural water samples. Natural water 100mL was sampled in 250mL separatory funnel. After Mo(VI)-ARS chelate ion was formed by adding 0.01M alizarin red S solution 0.5mL to the water sample of pH 4.0, 0.2% aliquat-336 chloroform solution 10mL was added and the solution was vigorously shaked for about 30 seconds to from the ion-pair between Mo(VI)-ARS and aliquat-336, completely. The solution was stood for about 90 minutes. And the organic phase was taken for the absorbance measurement of the ion-pair at 520 nm. The content of Mo(VI) in sample was obtained from the standard calibration curve. Several extraction conditions such as pH, adding amounts of alizarin red S and aliquat-336, and shaking and standing times were optimized. This procedure was applied to the analysis of river and tap waters. It could be confirmed from the recoveries of over 99% in samples spiked with a given amount of Mo(VI) that this method was quantitiative in the determination of trace Mo(VI) in a natural water.
The epidemiological relationship between the current prevalence and monthly reinfection rate of Ascaris lumbricoides was observed in rural communities in Korea by means of blanket mass chemotherapy and worm collection for measurement of the prevalence and reinfection rates. During the period from 1975 to 1980, a total of 4,466 inhabitants in 10 different localities were treated with 10 mg/kg of pyrantel pamoate and 2 days' whole stools were collected from 2,547 inhabitants. The stools were examined for the presence of expelled adult and/or young worms, which represent the prevalence and reinfection rates for past 2 months respectively. After then, the obtained rates were correlated each other applying the timeprevalence curve proposed by Hayashi. It was observed that the prevalence (overall worm positive rate) and worm burden per individual ranged by areas from 13. 6 to 72. 3% and 1.4~10. 2 respectively. The calculated monthly reinfection rates (X) (from young worm positive rates) according to areas were in the range, 2.6~16.2%, and clearly correlated with the current prevalence (Y) under the equation, $Y=1-(l-X)^{7.2}$ where 7.2 is time in month. The equation means that after one time mass chemotherapy the period needed to attain equilibrium of prevalence again would be about 7~8 months. And it is inferred that the majority of reinfected worms in human host turn over every 7~8 months.
Water surface velocity meters with microwave were applied to stream discharge measurements and its practical aspects were evaluted. The rating of the surface velocity meters was performed through a carriage and a water tank for the ship model test. It gave5.5% or less errors of average measured velocities under the vertical tilt ang1e of 20$^{\circ}$, 35$^{\circ}$, or 45$^{\circ}$ . A surface velocity meter was used to measure flood velocities at Yoju bridge from 8:00 a.m. to 10:00 a.m. on August 26, 1995. The results showed that surface velocities ranged from 2 to 4 m/s. With the measured surface velocities multiplied by 0.85, the discharge was computed as 10,500 m$^3$/s. It differed $\pm$2% or less from the value of a stage-discharge curve and that of an unsteady flow simulation. Although the measured data are used sparsely per 40 or 60 meters, the computed discharges do not give large variation. Stream discharge measurements were also performed under the normal condition without floods. With the known values of Taechong Dam releases. the depth averaging factors of velocity were calculated by 0.83~0.87. Although there are errors from wind action and inherent ones in the velocity meters, the research showed that surface velocity meters could be an simple and practical alternative for flood discharge measurements.
Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
/
2001.06a
/
pp.1526-1526
/
2001
To improve the accuracy of sweetness sensor in automated sorting operations, it is necessary to clarify unevenness of the sugar content distribution within fruits. And it is expected that the technique to evaluate the content distribution in fruits contribute to the development of the near-infrared (NIR) imaging spectroscopy. Sugiyama (1999) had succeeded to visualize the distribution of the sugar content on the surface of a half-cut green fresh melon. However, this method cannot be applied to red flesh melons because it depends on information of the absorption band of chlorophyll (676 nm), which is affected by the color of the fresh. The objective of this study was to develop the universal visualization method depends on the absorption band of sugar, which can be applied to various kinds of melons and other fruits. The relationship between the sugar contents and absorption spectra of both green and red fresh melons were investigated by using a NIR spectrometer to determine the absorption band of sugar. The combination of 2$\^$nd/ derivative absorbances at 902 nm and 874 nm was highly correlated with the sugar contents. The wavelength of 902 nm is attributed to the absorption band of sugar. A cooled charge-coupled device (CCD) imaging camera which has 16 bit (65536 steps) A/D resolution was equipped with rotating band-pass filter wheel and used to capture the spectral absorption images of the flesh of a vertically half-cut red fresh melon. The advantage of the high A/D resolution in this research is that each pixel of the CCD is expected to function as a detector of the NIR spectrometer for quantitative analysis. Images at 846 nm, 874 nm, 902 nm and 930 nm were acquired using this CCD camera. Then the 2$\^$nd/ derivative absorbances at 902 nm and 874 nm at each pixel were calculated using these four images. On the other hand, parts of the same melon were extracted for capturing the images and squeezed for the measurement of sugar content. Then the calibration curve between the combination of 2$\^$nd/ derivative absorbances at 902 nm and 874 nm and sugar content was developed. The calibration method based on NIR spectroscopy techniques was applied to each pixel of the images to convert the 2$\^$nd/ derivative absorbances into the Brix sugar content. Mapping the sugar content value of each pixel with linear color scale, the distribution of the sugar content was visualized. As a result of the visualization, it was quantitatively confirmed that the Brix sugar contents are low at the near of the skin and become higher towards the seeds. This result suggests that the visualization technique by the NIR imaging spectroscopy could become a new useful method fer quality evaluation of melons.
Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
/
v.33
no.5
/
pp.453-461
/
2015
In order to manage the deflection of a curved PCT girder bridge during construction, a GPS receiver was installed at the spot predicted to be the weak point during the incremental launching so as to measure the deflection at each construction stage. The deflections obtained in the experiment were compared with those derived from the monitoring of stress, temperature and inclination. The comparative analysis of the GPS measurement and analytical values obtained from finite element modeling with respect to the launching distance showed that the measured values differ by 0.6 to 1.6 times to the analytical results. This difference could be significantly reduced by thermal calibration. From the analysis of the behavioral pattern of the bridge, deflection occurred during construction in the concrete tip due to the deflection at the head of the nose at the 95m and 75m-spots, and compression and tension developed respectively at the compression weak zone and tension weak zone. The application of GPS appeared to enable more efficient management of the deflection during the erection of the curved PCT girder bridge and is expected to be helpful for the prediction and management of the behavior in future ILM construction sites.
Purpose : Glomerular filtration rate (GFR) is a fundamental parameter in assessing renal function and predicting the progression of chronic renal disease. Because the use of serum creatinine has several disadvantages, many studies have investigated the use of cystatin C for estimating GFR. We compared creatinine clearance and GFR with formulas using serum creatinine and cystatin C. Methods : We retrospectively analyzed 211 patients with various renal diseases and classified them into two groups according to creatinine clearance (Group 1: CrCl >$90mL/min/1.73m^2$, Group 2: CrCl <$90mL/min/1.73m^2$). We measured serum creatinine, cystatin C, and creatinine clearance. We calculated GFR using the Schwartz, Counahan, Filler and Lepage, Bokencamp et al, and Grubb et al formulas. Results : GFR determined by the Schwartz formula had the highest correlation to creatinine clearance (r=0.415, P=0.00). GFR determined by various formulas using cystatin C had lower correlation to creatinine clearance (r=0.187, r=0.187, r=0.291). The Schwartz and Counahan formulas showed greater diagnostic accuracy in detecting decreased GFR than cystatin C in group 2 (areas under the curve: Schwartz, 0.596; Counahan, 0.572; Filler, 0.512; Bokencamp, 0.508; and Grubb, 0.514). Conclusion : GFR determined by the Schwartz and Counahan formulas using serum creatinine showed higher correlation coefficient than that determined by formulas using cystatin C. The formulas using cystatin C were not superior to those using serum creatinine in detecting decreased GFR. Cystatin C measurement was not satisfactory for assessing GFR in patients whose renal function was not severely decreased.
The analytical method of lead in plasma by ICP-MS was validated after securing environment within class 1,000 classification. We tested specificity and accuracy of within-run and between-run. According to measurement of the amount of suspended particulates in a clean room, 0.3~62 particles were detected in 0.3 µm size while 0.0~28.3 particles were observed in 0.5 µm size. Total suspended particulates met required environment with up to 90.3 particles. The MDL (Method detection limit) of the sample which has been fabricated using fetal bovine serum (FBS) blank was 1.77 ng/L, and LOQ (Limit of quantification) was 5.55 ng/L. The slope, intercept and correlation coefficient of the calibration curve were y=1.09×10−3x+4.88×10−2 and r=0.9999, which showed good correlation. The specificity, within-run and between-run accuracy satisfied the standard at more than 50 ng/L. The average lead concentration in plasma of the general people, current workers and retired workers was 55.4 ng/L, 440 ng/L, and 132 ng/L.
Journal of Korean Tunnelling and Underground Space Association
/
v.16
no.1
/
pp.51-61
/
2014
It is necessary to perform a dynamic analysis to numerically evaluate the effect of blasting on nearby facilities. The blast load time history, which cannot be directly measured, is most often determined from empirical equation. The load has to be adjusted to account for various factors influencing the load and the frequency, but there is not a clear guideline on how to adjust the load. In this study, a series of 2D dynamic numerical analyses that simulates a closely monitored test blasting is performed, from which the blast load that matches the measured vibrations are derived. In the analyses, it is assumed that the hole generated by the blasting is in the form of a circle, and the load was applied normally to the wall of the opening. Special attention was given in selecting the damping ratio for the ground, since it has important influence on the wave propagation and attenuation characteristics of the blast induce waves. The damping ratio was selected such that it matches favorably with the attenuation curve of the measurement. The analyses demonstrate that the empirical blast load widely used in practice highly overstimates the vibration since it does not account for the energy loss due to rock fragmentation. If the empirical load is used without proper adjustment, the numerical analysis may seriously overstimate the predicted vibration, and thus has to be reduced in the analysis.
Journal of the Korea Academia-Industrial cooperation Society
/
v.15
no.6
/
pp.3442-3447
/
2014
A simple method to evaluate the hygroscopic characteristics of polymer of microelectronic plastic package is suggested. To evaluate the characteristics, specimens were prepared, and the internally absorbed moisture masses were measured as a function of the absorbing time and calculated numerically. The hygroscopic pressure ratio was calculated by heat transfer analysis supported by commercial FEM code because the hygroscopic diffusion equation has the same form as the heat transfer equation. The moisture masses were then summed by the self developed code. The nonconductive polymers had quite different characteristics for the different lots, even though they were the same products. The absorbed moisture mass variations were calculated for several different characteristics, and the optimal curve of the mass variation close to experimental data was selected, whose solubility and diffusivity were affected by the hygroscopic characteristics of the material. The method can be useful in the industrial fields to quickly characterize the polymer material of the semiconductor package because the fast correspondence is normally required in industry. The weight changes in the aluminum-nonconductive-polymer joint due to moisture absorption were measured. The deformed system was also measured using the Moire Interferometry system and compared with the results of finite element analysis.
Yang, Kyoung Hoon;Kim, Nam Kyu;Kim, Young Soo;Ko, Yong;Oh, Seong Hoon;Oh, Suck Jun;Kim, Kwang Myung
Journal of Korean Neurosurgical Society
/
v.29
no.1
/
pp.78-86
/
2000
Objective : Lumbar spinal instability occurs when normal biomechanics support in lumbar vertebrae interrupted. Despite the recent enthusiastic studies, the precise radiological assessment has not been fully established, yet. Therefore, we carefully studied our cases to analyze the radiologic findings in lumbar spinal instability. Patients and Methods : We have put together radiological analysis and assessment based on 38 patients who have been diagnosed and treated for lumbar spinal instabilities from June 1994 to December 1998, Patients who have been diagnosed and treated for trauma were excluded from study. Results : The outcomes are as follows : 1) Lumbar lordotic curve was statistically significant in unstable group by 23.7, compared to the control group ($17.0^{\circ}$). 2) According to the resting x-ray, sagittal plane angulation measured on unstable group was $21.1^{\circ}$, control group $18.0^{\circ}$. Therefore unstable group was noticeably higher(p<0.01). 3) According to the resting x-ray sagittal plane displacement, unstable group had 4.3mm, the comparison had 1.2mm. Therefore measurement from the unstable group were significantly higher(p<0.01). 4) According to stress view, sagittal plane translation was 4.1mm for the unstables and 2.7mm for the comparisons. Therefore unstables were noticeably higher(p<0.01). 5) According to stress view, sagittal plane rotation was $15.1^{\circ}$ at L3-4, $22.0^{\circ}$ at L4-5, $27.9^{\circ}$ at L5S1 for the unstable group and $11.3^{\circ}$, $18.1^{\circ}$, $21.0^{\circ}$ each for the comparison. 6) Facet angle for unstable group, left $29.3^{\circ}-61.5^{\circ}$, right $24.4^{\circ}-63.2^{\circ}$ and the mean for each are $43.1^{\circ}$, $47.2^{\circ}$. The difference between left and right facet angle was $3.5^{\circ}-20.7^{\circ}$ and the mean value $15.3^{\circ}$. Facet angle for the comparisons for the left was $29.3^{\circ}-59.5^{\circ}$, right was in between $25.7^{\circ}-64.5^{\circ}$ range and the each mean are $44.9^{\circ}$ and $47.6^{\circ}$. Also, the difference between left and right facet angle was $4.1^{\circ}-9.3^{\circ}$ and the average was $17.1^{\circ}$. The average and the difference between the left and right angle are found not to have statistic necessity for both unstable and stable measurements(p>0.01). 7) 19 patients were found to have vacuum facet phenomenon among unstable group etc. results were collected. Conclusion : According to above results, we attempted to prepare the application to the patient of radiological analysis and assessment for lumbar spinal instability early checkup.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.