• Title/Summary/Keyword: Curve measurement

Search Result 991, Processing Time 0.033 seconds

Usefulness of the quantitative analysis by using the functional parameter index from dynamic salivary glands scintigraphy (동적 타액선 신티그라피에서 기능적 매개변수 지표를 활용한 정량 분석의 유용성)

  • Shin, Chae Ho;Kim, Bong Su;Cho, Yong Gyi;Jo, Jin Woo;JIn, Sung Eun;Pyo, Sung Jai
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.81-86
    • /
    • 2015
  • Purpose This study was to evaluate the usefulness through the comparison of patients group and healthy control group by acquiring a variety of functional parameters index from time-activity curves of salivary gland scintigraphy using $^{99m}Tc$. Materials and Methods From December 2014 to February 2015 with the targets of 30 patients in the patient group who presented themselves with xerostomia and underwent the salivary gland scan and 10 people in healthy control group, approximately 30 minutes of dynamic Scan was carried out after the intravenous bolus injection of 370 MBq of $^{99m}TcO_4{^-}$ and per os stimulation with Vitamin C powder 20 minutes after the injection. The method of quantitative analysis was as follows, the time-activity curve was drawn after the parotid gland and submandible gland were prescribed as a region of interest, a variety of functional parameters index was obtained in each position of the curve, and the patients group and the control group were compared. Results As for the methods applied in comparison and measurement, uptake ratio (UR), time at maximum counts (Tmax), time at minimum counts (Tmin), maximum accumulation (MA), accumulation velocity, maximum secretion (MS), maximum stimulation secretion (MSS), and secretion velocity (SV) were used. In the comparison of functional parameters index of patient group and normal group, the healthy normal group showed significant difference compared to the patient group in all indices except for the minimum radioactivity time (Tmin), and also in terms of variation over time the normal group showed significant difference compared to the patient group (p<0.05). Conclusion Consequently, it was considered that the quantitative analysis that used a variety of functional parameters index would be useful for evaluating the function of the salivary glands of the patients with xerostomia as an objective and standardized information.

  • PDF

Structural Characteristics and Physical Properties of Wild Silk Fibres; Antheraea pernyi and Antheraea yamamai (야잠사의 구조특성 및 물리적 성질)

  • 권해용;박영환
    • Journal of Sericultural and Entomological Science
    • /
    • v.36 no.2
    • /
    • pp.138-146
    • /
    • 1994
  • The structural characteristics of Antheraea yamamai and Antheraea pernyi silk were investigated by using x-ray diffraction method, IR spectroscopy and polarizing microscopy. The amino acid composition, fiber density, thermal decomposition temperature and glass transition temperature were also measured for relating these physical properties to the structure in comparison with those of Bombyx mori silk fiber. There was no significant structural difference between A. yamamai and A. pernyi silk fiber on an examination of x-ray diffraction curve and IR spectrum. Both of these wild silk fibers showed double diffraction peaks at the Bragg angle 2Θ16.7˚ and 20.5˚by x-ray diffraction analysis as well as IR absorption peaks for the bending vibration of specific groups related to ala-ala amino acid sequence. On the other hand, the x-ray diffraction curve and IR spectrum of Bombyx mori silk fiber are different from those of wild silk fibers, indicating different crystal structure as well as amino acid sequences. It showed under the polarizing microscope examination that the birefringence and optical orientation factor of wild silk fibers are much lower than those of B. mori silk. Also, the surface of degummed wild silk fibers was characterized by the longitudinal stripes of microfibrils in the direction of fiber axies. The amino acid composition, which is strongly related to the fine structure and properties, was not significantly different between these two wild silk fibers. However, the alanine content was somewhat less and polar amino acid content more for A. yamamai. As a result of fiber density measurement, the specific gravities of B. mori, A. pernyi and A. yamamai were 1.355~1.356, 1.308~1.311, 1.265~1.301g/㎤ in the order, respectively. The calculated crystallinity(%) was 64% for B. mori and 51~52% for wild silk fibers, which showed same trend by IR method in spite of somewhat higher value. The thermal decomposition behaviour was examined by DSC and TGA, showing that the degradation temperature was in the order of B mori, A. prernyi and A. yamamai at around 350$^{\circ}C$. It was also observed by TGA that the decomposition seems to proceed step by step according to their specific regions in the fiber structure, resulting the difference in their thermal stabilities. The glass transition temperature was turned out to be 220$^{\circ}C$ for B. mori, 240$^{\circ}C$ A. yamamai and 255$^{\circ}C$ A. pernyi by the dynamic mechanical analysis. It is expected that the chemical properties are affected by the dynamic mechanical behavior in accordance with their structural characters.

  • PDF

Diagnostic Value of Cyfra 21-1 in Differential Diagnosis of Pleural Effusion (흉수의 감별 전단으로 Cyfra 21-1의 진단적 가치)

  • Lee, Hak-Jun;Lee, Kwan-Ho;Shin, Kyeong-Cheol;Shin, Chang-Jin;Park, Hye-Jung;Mun, Yeung-Chul;Lee, Kyung-Hee;Chung, Jin-Hong;Hyun, Myung-Soo;Lee, Hyun-Woo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.1
    • /
    • pp.50-56
    • /
    • 1999
  • Background : Pleural effusion is a common clinical problem and many clinical and laboratory evaluations, such as tumor marks, have been studied to discriminate malignant pleural fluid from benign pleural fluid. However their usefulness in the diagnosis of pleural effusion is still not established fully. We studied the diagnostic value of cyfra 21-1 in diagnosis of malignant pleural effusion. Methods: Pleural fluid was obtained from 45 patients with malignant diseases(32 lung cancer patients, 13 metastatic malignant diseases) and 47 patients with benign diseases. The level of cyfra 21-1 in the pleural fluid and serum were determined using a CYFRA 21-1 enzyme immunoassay kit(Cis-Bio International Co.). The t-test was used for comparison between two diseases groups and receiver operating characteristic(ROC) curves were constructed by calculating the sensitivities and specificities of the cyfra 21-1 at several points to determine the diagnostic accuracy of the cyfra 21-1. Results: In patients with primary lung cancer, the level of cyfra 21-1 in the pleural fluid was significantly higher than those of patients with benign diseases and had positive correlations between the level of cyfra 21-1 in the pleural fluid and serum levels. In the ROC curve analysis of the pleural fluid, the curve for primary lung cancer group was located closer to the left upper comer and the cut off value, sensitivity and specificity of the cyfra 21-1 of the primary lung cancer group was determined as 22.25ng/ml, 81.8% and 78.7% respectively. Conclusions: Our data indicates that the measurement of cyfra 21-1 level in pleural effusion has useful diagnostic value to discriminate malignant pleural effusion in primary lung cancer from benign pleural effusion.

  • PDF

THE ANTICANCER EFFECT OF PACLITAXEL($Taxol^{(R)}$) IN ORAL SQUAMOUS CELL CARCINOMA XENOGRAFT (이종 이식된 구강편평세포 암종에서 Paclitaxel ($Taxol^{(R)}$)의 항암 효과)

  • Kim, Ki-Hwan;Kim, Chul-Hwan;Han, Se-Jin;Lee, Jae-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.2
    • /
    • pp.95-110
    • /
    • 2006
  • The treatment for oral and maxillofacial carcinoma with chemotherapeutic agents is evaluated by many effective methods to reduce the tumor mass and cancer cell proliferation. However these chemotherapy have many serious side effects, such as bone marrow suppression, renal toxicity, G-I troubles. Therefore a possible approach to develop a clinically applicable chemotherapeutic agent is to screen anticancer activity of Taxol which is known to have very little side effect and have been used to breast cancer and ovarian carcinoma. Taxol is a new anti-microtubular anti-cancer agent extracted from the bark of the Pacific yew, Taxus brevifolia. Paclitaxel(Taxol) acts by promoting tubulin polymerization and over stabilizing microtubules agianst depolymerization. Despite the constant improvements of methods of the cancer treatment especially chemotherapy, the rate of cancer metastasis and recurrent are not decreased. Thus the investigation of new drug which have very little side effect and a possible clinically application continues to be a high priority. Considering that the Taxol have shown very effective chemotherapeutic agent with relatively low toxicity in many solid tumors, it deserves to evaluate its efficacy in oral squamous cell carcinoma. In this study, to investigate the in-vivo and in-vitro anti-cancer efficacy of Taxol in oral squamous cell carcinoma and lastly, the potency of Paclitaxel in the clinical application for oral cancer was evaluated. In vivo study, after HN22 cell line were xenografted in nude mice, the growth of tumor mass was observed, 3 mg/Kg taxol was injected intraperitoneally into nude mice containing tumor mass. The methods of these study were measurement of total volume of tumor mass, histopathologic study, immunohistochemical study, drug resistance assay, growth curve, MTT assay, flow cytometry, cDNA microarray in vivo and in vitro. The results were obtained as following. 1. The visual inspection of the experimental group showed that the volume of the tumor mass was slightly decreased but no significant difference with control group. 2. Ki-67 index was decreased at weeks 4 in experimental group. 3. Microscopic view of the xenografted tumor mass showed well differentiated squamous cell carcinoma and after Taxol injection, some necrotic tissue was seen weeks 4. 4. The growth curve of the tumor cells were decreased after 1day Taxol treatment. 5. According to the MTT assay, HN22 cell line showed relative drug resistancy above $5\;{\mu}g/ml$ concentrations of Taxol. 6. In drug resistance assay, the decrease of cell counts was seen relatively according to concentration. 7. In Flow cytometry, G2M phase cell arrests were seen in low concentration of the Taxol, while S phase cell arrests were seen in high concentration of the Taxol. 8. Using cDNA microarray technique, variable gene expression of ANGPTL4, TXNRD1, FAS, RRAGA, CTGF, CYCLINEA, P19, DUSP5, CEBPG, BTG1 were detacted in the oral squamous cell carcinoma cell after taxol treatment. In this study paclitaxel is effective against oral squamous cell carcinoma cell lines in vitro, but week effect was observed in vivo. So we need continuous study about anticancer effect of taxol in vivo in oral squamous cell carcinoma.

Competitive ELISA for the Measurement of Glycoprotein Purified from Acanthopanx senticosus (가시오가피로부터 분리한 단백 다당물질의 경쟁적 ELISA법에 의한 분석)

  • Ha, Eun-Suk;Hwang, Soo-Hyun;Shin, Kwang-Soon;Yu, Kwang-Won;Lee, Keyung-Ho;Choi, Joo-Sun;Park, Woo-Mun;Yoon, Taek-Joon
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.1209-1215
    • /
    • 2003
  • This study was carried out to establish a quantitative analysis method of separating immuno-activating substance (EN-SP) from Acanthopanax senticosus (A. senticosus) by competitive direct ELISA. Mouse antiserum (anti-EN-SP) against EN-SP was generated by immunization (s.c.) of EN-SP purified from A. senticosus as an immunogen. The titer of anti-EN-SP was about 1 : 400, and the optimal dilution of EN-SP-HRP conjugate was 1 : 1,000. When the standard curve was constructed by ELISA, its sensitivity was about $0.2{\mu}g/mL$. The coefficient variation of intra- and inter-assay were $6.13{\sim}8.81%$ and $6.73{\sim}8.60%$, respectively. According to the standard curve, the concentration of EN-SP in various senticosus extracts was found to be only $59.85\;{\mu}g$ in 10mg of extract from the bark of A. senticosus. Similarly, the immunostimulating activity to produce $TNF-{\alpha}$ or IL-12 among the various extracts of Acanthopanax was shown to be correlated with the content of EN-SP. These results demonstrated that competitive ELISA was a convenient, fast, reproducible, and accurate method for the determination of EN-SP as an immunologically active standard substance in extract of A. senticosus.

Model Equations to Estimate the Soil Water Characteristics Curve Using Scaling Factor (Scaling Factor를 이용한 토양수분특성곡선 추정모형)

  • Eom, Ki-Cheol;Song, Kwan-Cheol;Ryu, Kwan-Shig;Sonn, Yeon-Kyu;Lee, Sang-Eun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.28 no.3
    • /
    • pp.227-232
    • /
    • 1995
  • The model equations including scaling factors to estimate the soil water characteristics curve(SWCC) without direct measurement of soil water tension were developed. Scaling were applied to a data set of soil water content, soil water tension, particle size distribution, and OM contents of the 134 soil samples with the 10 soil textural classes. The capability of the model equations was tested on another 205 soil samples. The parameter, ${\theta}^*$, of soil water contents was used by scale transformation as follows : ${\theta}^*=[{\theta}i-{\theta}(1.5MPa)]$/$[{\theta}(10KPa)-{\theta}(1.5MPa)]$ Using ${\theta}^*$ a model equation to estimate SWCC, which was applicable to all textural classes, was developed as follows: $H(0.1MPa)=0.13{\cdot}({\theta}^*)^{-2.04}$. Other model equations to estimate the water content at the soil water tension of 10KPa [${\theta}(10KPa)$] and 1.5MPa [${\theta}(1.5MPa)$], which are required to ${\theta}^*$ were developed by using scale factors of sand(S) and silt(Si) content and organic matter content(OM) as foilows : ${\theta}(10KPa)=26.80-3.99ln[S]+2.36{\sqrt{[Si]}}+2.88[OM]$ ($R=0.81^{**}$) ${\theta}(1.5KPa)=15.75-2.86ln[S]+0.55{\sqrt{[Si]}}+0.70[OM]$ ($R=0.76^{**}$) The measured and estimated values of ${\theta}(1/30MPa)$ on the 205 soil samples were highly correlated on 1 : 1 corresponding line with $R=0.85^{**}$.

  • PDF

Comparisons of Soil Water Retention Characteristics and FDR Sensor Calibration of Field Soils in Korean Orchards (노지 과수원 토성별 수분보유 특성 및 FDR 센서 보정계수 비교)

  • Lee, Kiram;Kim, Jongkyun;Lee, Jaebeom;Kim, Jongyun
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.401-408
    • /
    • 2022
  • As research on a controlled environment system based on crop growth environment sensing for sustainable production of horticultural crops and its industrial use has been important, research on how to properly utilize soil moisture sensors for outdoor cultivation is being actively conducted. This experiment was conducted to suggest the proper method of utilizing the TEROS 12, an FDR (frequency domain reflectometry) sensor, which is frequently used in industry and research fields, for each orchard soil in three regions in Korea. We collected soils from each orchard where fruit trees were grown, investigated the soil characteristics and soil water retention curve, and compared TEROS 12 sensor calibration equations to correlate the sensor output to the corresponding soil volumetric water content through linear and cubic regressions for each soil sample. The estimated value from the calibration equation provided by the manufacturer was also compared. The soil collected from all three orchards showed different soil characteristics and volumetric water content values by each soil water retention level across the soil samples. In addition, the cubic calibration equation for TEROS 12 sensor showed the highest coefficient of determination higher than 0.95, and the lowest RMSE for all soil samples. When estimating volumetric water contents from TEROS 12 sensor output using the calibration equation provided by the manufacturer, their calculated volumetric water contents were lower than the actual volumetric water contents, with the difference up to 0.09-0.17 m3·m-3 depending on the soil samples, indicating an appropriate calibration for each soil should be preceded before FDR sensor utilization. Also, there was a difference in the range of soil volumetric water content corresponding to the soil water retention levels across the soil samples, suggesting that the soil water retention information should be required to properly interpret the volumetric water content value of the soil. Moreover, soil with a high content of sand had a relatively narrow range of volumetric water contents for irrigation, thus reducing the accuracy of an FDR sensor measurement. In conclusion, analyzing soil water retention characteristics of the target soil and the soil-specific calibration would be necessary to properly quantify the soil water status and determine their adequate irrigation point using an FDR sensor.

Effect of the Degree of Weathering on the Distribution of Aggregate Particle Size and the Generation of Fine Rock Particles during Crushing of Granite (화강암 파쇄시 풍화정도가 골재 입도분포 및 미석분 발생에 미치는 영향)

  • You, Byoung-Woon;Lee, Jin-Young;Lee, Dong-kil;Cheong, Young-Wook
    • Economic and Environmental Geology
    • /
    • v.55 no.5
    • /
    • pp.429-438
    • /
    • 2022
  • This study evaluated the effect of the degree of weathering on the particle size distribution and the amount of fine particles generated in the aggregate production process during the crushing of igneous rock. Rock samples were collected from three areas with differences in strength from the Schmith hammer measurement at the aggregate quarry in Geochang, Gyeongsangbuk-do. After crushing with a jaw crusher under the same conditions in laboratory, particle size analysis, mineral analysis, chemical analysis, and weathering index were calculated. The Schmidt hammer measurements were 56, 28, and <10, and the CIA and CIW values of weathering index were also different, so the rock samples were classified into hard rock, soft rock, and weathered rock according to the weathering degree. It shows a smaller particle size distribution toward weathered rocks under the microscope, and the proportion of altered clay minerals such as sericite increased. The composition of feldspar and quartz was high for hard rock, and the ratio of muscovite and kaolinite was low. As a result of the crushing of the jaw crusher, hard rock produced a lot of coarse crushed material (13.2mm), while soft rock and weathered rock produced fine crushed material (4.75mm). The former showed the characteristics of the beta distribution curve, and the latter showed the bimodal distribution curve. The production of fine rock particles (based on 0.71mm of sieve, wt. %) increased to 13%<21%<22% in hard rock, soft rock, and weathered rock, and the greater the degree of weathering, the more fine rock particles were generated. The fine particles are recovered by the operation of the sand unit in the wet aggregate production process. Therefore, in order to minimize the amount of sludge generated in the aggregate production process, it was judged that a study on the optimal operation of cyclones could be necessary.

Development and Verification of a Large Scale Resonant Column Testing System (대형 공진주시험기의 개발 및 검증)

  • Kim, Nam-Ryong;Ha, Ik-Soo;Shin, Dong-Hoon;Kim, Min-Seub
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.6C
    • /
    • pp.295-304
    • /
    • 2012
  • In this study, a resonant column testing system which is the largest in Korea has been developed to evaluate the dynamic deformation characteristics of coarse granular geomaterials, and the performance and the applicability of the testing system have been verified. The system has been developed as a typical Stokoe type device whose boundary conditions are fixed bottom and free top with additional mass, and can adopt a large specimen with 200 mm in diameter and 400 mm in height. The driving and measurement instruments are configured as high performance and precision systems, hence the automated testing system is appropriate to drive enough stress and to measure the behavior precisely for the test in practical manner. The dynamic response of the mechanical components and the applicability of the system have been evaluated using metal specimens as well as polyurethane specimens, and its precision was verified by comparing its results with those from other equipment and/or methods. To confirm the applicability of the large system for coarse geomaterials, the resonant column test results from both large and normal scale apparatus for the same material were compared and it was found that the result can be partially affected by scale. Finally, the dynamic deformation characteristics of coarse geomaterial which is used for construction of large dam was evaluated using the large system and its practicality could be confirmed.

Design of Optical System for LED Lamp using MR16 (MR16용 LED 램프 조명설계)

  • Kim, Jun-Hyun;Moon, Byung-Kwon;Ryu, In-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.10
    • /
    • pp.4725-4732
    • /
    • 2012
  • This paper studies MR16 that can strengthen the strength and make up for the weakness of MR16 by replacing halogen light source using multifaceted Reflector(MR16) with LED light source. To achieve this, developed MR16 for LED applying optical system that four aspheric lens is one sheet. Optical system is designed by optics software and lighting performance of the designed data is predicted lighting simulation program. Also, heatsink's heat radiation analysis program to predict the thermal performance. Finally, optical prototype system based on simulation analysis data is manufactured and the results comparing performance of the developed system and the designed data are follows: Radiation angle was around $50^{\circ}{\sim}60^{\circ}$ in results of simulation analysis and the test of the prototype system. Also, temperature measurement result indicates that the thermal equilibrium is realized after one minute and thirty seconds and heat is generated up $60^{\circ}C$ in all of simulation analysis and the test of the prototype system. Finally, simulation analysis result on light disturbance curve of MR16 is similar to that of performance of the prototype system.