• Title/Summary/Keyword: Curvature Effect

Search Result 650, Processing Time 0.025 seconds

Effects of Corrugated Webs on the Ultimate Behavior of Horizontally Curved I-shaped Girders (파형 복부판이 수평 곡선 I형 거더의 극한 거동에 미치는 영향)

  • Kim, Seungjun;Han, Taek Hee;Won, Deok Hee;Kang, Young Jong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1327-1336
    • /
    • 2013
  • In this study, the effects of corrugated webs on the ultimate behavior of horizontally curved I-shaped girders are investigated. Because of the geometric characteristics of corrugated plates, corrugated webs can be used for enhancing torsional and warping stiffness of plate girders. Many researches have been conducted to study the effects of corrugated webs on the ultimate behavior of straight girders. But, the studies of the ultimate behavior of horizontally curved girders with corrugated webs, which generally show out-of plane behavior manly, have been rarely performed so far. By performing inelastic-nonlinear analysis, the ultimate behavior of curved girders with corrugated webs is studied in this paper. Laterally unsupported length and subtended angle of girders, and length of height of corrugation of webs are considered as the geometric parameters which would be expected to affect the ultimate behavior. By this analytical study with considering the geometric parameters, the changes of ultimate behavior and load carrying capacity of curved girders with corrugated webs are investigated. Also, the effects of corrugated webs on the increase of load carrying capacity for curved girders are studied with comparing to the capacity of general curved girders with flat webs. According to the analytical results, corrugated webs can be used to increase the ultimate load carrying capacity of curved girders, because of their high torsional and warping stiffness. But, it is also indicated that they may decrease the load carrying capacity of curved girders which have relatively small subtended angle or initial curvature, because of an accordion effect.

The Effects of Yoga Program on Idiopathic Scoliosis (요가운동프로그램이 특발성 척추 측만증에 미치는 효과)

  • Eom, Chanil;Seo, Junhwan;Hong, Seonggyun
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.427-431
    • /
    • 2013
  • The purpose of this study in the patient suffering from scoliosis analyse the degree of scoliosis, Cobb's angle, by Yoga exercise therapy and then find the effects of Yoga program on idiopathic scoliosis. In this study, yoga program restores flexibility and elasticity by relaxing and contracting muscles around vertebrea. It could help scoliosis from balancing agonistic muscle, antagonistic muscle and synergistic muscle during exercise. so did pelvis movement and vertebral twisting movement. The subject for this experiment was a meddle school girl diagnosed with scoliosis in C hospital in Gwang-ju city. In order to find the effects of yoga program on idiopathic scoliosis, conducted yoga program 60minutes a day, 5days a week for 12weeks. Before and after experiment, measured Cobb's angle by radiation and verified effects. First, master of yoga and chiropractor studied and made movement together. Second, Yoga program-developed about scoliosis was prescribed for the meddle school girl suffering from scoliosis during 12weeks. Third, Feasibility and effect was verified on idiopathic scoliosis by yoga program. As a result, the amount of curvature was reduced about 5degrees than before and improved the idiopathic scoliosis. Lots of Yoga movements help patients of idiopathic scoliosis to be improved. It shows that Yoga program could give adolescent scoliosis a hand.

Pushover Analysis of a Five-Story Steel Framed Structure Considering Beam-to-Column Connection (보-기둥 접합부를 고려한 5층 철골골조구조물의 비탄성 정적해석)

  • Kang, Suk-Bong;Lee, Jae-Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.2
    • /
    • pp.129-137
    • /
    • 2010
  • In this study, a five-story steel frame was designed in accordance with KBC2005 to evaluate the effect of the beam-column connection on the structural behavior. The connections were designed as a fully rigid connection and as a semirigid connection. A fiber model was utilized to describe the moment-curvature relationship of the steel beam and column, and a three-parameter power model was adopted for the moment-rotation angle of the semirigid connection. To evaluate the effects of higher modes on structural behavior, the structure was subjected to a KBC2005-equivalent lateral load and lateral loads considering higher modes. The structure was idealized as a separate 2D frame and as a connected 2D frame. The pushover analysis of 2D frames for the lateral load yielded the top displacement-base shear force, design coefficients such as overstrength factor, ductility ratio, and response modification coefficient, demanded ductility ratio for the semirigid connection,and distribution of plastic hinges. The sample structure showed a greater response modification coefficient than KBC2005, the higher modes were found to have few effects on the coefficient, and the lateral load of KBC2005 was found to be conservative. The TSD connection was estimated to secure economy and safety in the sample structure.

Undifferentiated Adenocarcinoma with Rhabdoid Features in the Stomach: A Case Report (횡문근양 미분화 위선암 1예 보고)

  • Im, Myoung-Goo;Jun, Kyong-Hwa;Won, Yong-Sung;Jung, Ji-Han;Chin, Hyung-Min;Park, Woo-Bae;Chun, Chung-Soo
    • Journal of Gastric Cancer
    • /
    • v.7 no.2
    • /
    • pp.107-112
    • /
    • 2007
  • Rhabdoid tumor has been considered to be a rare subtype of Wilm's tumor with Rhabdomyoma features. Since rhabdoid tumor that developed in the kidney was described for the first time in 1989, it has been reported in the gastrointestinal tract, although this is rare. The appropriate treatment is radical resection, and the effect of adjuvant chemotherapy has not yet been reported on. The outcome of extra-renal rhabdoid tumor is different from renal rhabdoid tumor and the former shows a poor prognosis. Among extra-renal rhabdoid tumors, undifferentiated gastric adenocarcinoma with rhabdoid features is very rare and its prognosis is poor. A 63 years old male patient underwent total gastrectomy for a tumor that developed in the greater curvature of the gastric body and this was diagnosed as undifferentiated gastric adenocarcinoma with rhabdoid features, according to the histopathology. We experienced an undifferentiated gastric adenocarcinoma with rhabdoid features that was diagnosed by immunohistochemical staining and we report here on this case.

  • PDF

Bending of Korea red pine (Pinus densiflora) by Microwave Irradiation (마이크로파 가열에 의한 소나무재의 곡가공)

  • Jung, Sung-Soo;Lee, Weon-Hee
    • Journal of the Korean Wood Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.17-22
    • /
    • 1999
  • The effect of microwave irradiation on wood bending was investigated in this study. The specimens irradiated with microwave were bent around a form by using pedestal-steel and clamps. The specimens, korea red pine (Pinus densiflora), for this test were water-soaked for 78 hours. Saturated specimens were boiled in water for an hour. The size of specimens was 350mm(L) by 20mm(R) by 10mm(T). These specimens were heated by microwave of 2,450MHz. The most suitable time for microwave irradiation seems to range from 60 to 90 seconds. Wood moisture content decreased remarkably with the increase of irradiation time. When a softened wood piece is bent, its convex side was stretched while the concave side was compressed. It can be compressed considerably, but stretched very little. Therefore the failure will be governed by the tensile breaking strain and occur mainly on the convex face. So we obtained results from three different bending process methods as follows : 1) When bending with a pedestal-steel, convex face had not tensile breakings, but concave face had compression fails. 2) When bending with a clamp, bending time increased more than pedestal-steel and occurred tensile breaking. 3) Bending with a pedestal-steel and a clamp was found to be the most excellent operation method in this study.

  • PDF

The Effect of Pelvic Tilt on Muscle Activity of Cervical Erector Spinae & Upper Trapezius While Using a Smartphone (골반경사에 따른 스마트폰 사용이 목세움근과 위등세모근의 근활성도에 미치는 영향)

  • Song, Seong-In;Kang, Jong-Ho
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.4
    • /
    • pp.97-103
    • /
    • 2017
  • The purpose of this study was to investigate muscle activity of cervical erector spinae & upper trapezius while using a smartphone according to anterior pelvic tilt & posterior pelvic tilt in sitting position. & we also want to obtain basic data necessary for development of IoT devices. Fifteen healthy men & women aged 20-30 were enolled, After anterior pelvic tilt & posterior pelvic tilt in sitting position were adjusted, they used a smartphone for 5 minutes & EMG signal was measured simultaneously. We used median 3 minutes of measured EMG signal. The results of this study were as follows: In the sitting position, the use of smartphone in anterior pelvic tilt had significantly lower %RVC values in both cervical erector spinae (p <.001), left upper trapezius (p <.001) & right upper trapezius (p <.002) in comparison with posterior pelvic tilt. This means that anterior pelvic tilt make vertebrae maintain normal curvature & prevent forward head posture occurred while using a smartphone. It reduces loads around neck & shoulders, so that %RVC value is significantly lowered. In the future, new posture corrected IoT devices with an aspect of pelvic tilt should be developed.

THE EFFECT OF SOME CANAL PREPARATION TECHNIQUES ON THE SHAPE OF ROOT CANALS (수종의 근관형성 방법이 근관 형태에 미치는 영향)

  • Lee, Ji-Hyeon;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.337-345
    • /
    • 1999
  • The purpose of this study was to compare the shape of root canal after instrumentation with some engine driven NiTi files. Thirty narrow and curved canals(15-35 degree) of mesial canals of extracted human mandibular first molars were divided into three groups. Group 1: After radicular access with Gates Glidden drill, apical shaping using step back method with Flexo file Group 2: After radicular access with Gates Glidden drill, apical shaping with Profile .04 Group 3: Canal shaping with GT file and Profile .04. Using modified Bramante technique, the root was sectioned at 2 mm from apical foramen, height of curvature, 2 mm from canal orifice. Canal centering ratio, amount of transport, amount of dentin removed, shape of canal were measured and statistical analysis is done using SPSS Program V 7.5. The results were as follows: 1. Canal centering ratio of group 3 was the lowest at coronal part, but there was no statistical difference. Centering ratio of group 2 was the lowest at curve part, and there was statistical difference between group 1(P<0.05). Centering ratio of group 2 was the lowest at apical part, but there was no statistic difference. 2. Amount of transport of group 3 was the lowest at coronal part, but there was no statistical difference. Amount of transport of group 2 was the lowest at curve part, and there was statistical difference between group 1(P<0.05). Amount of transport of group 3 was the lowest at apical part, and there was statistical difference between group 1 and group 2, group 1 and group 3(P<0.05). 3. Amount of dentin removed of group 3 was the lowest at coronal part, bur there was no statistical difference. Amount of dentin removed of group 2 was the lowest at curve part, but there was no statistical difference. Amount of dentin removed or group 2 was the lowest at apical part, and there was statistical difference between group 1 and group 2, group 1 and group 3(P<0.05). 4. The shape of the canals after instrumentation varied among the groups. The majority of canals at coronal and curve part for group 1 were round in shape(7 in 10), those at apical part were oval(8 in 10). The majority of canals at coronal part for group 2 were round in shape(7 in 10) and there was no difference in the number of shape at other part. There was no difference in the number of shape at every part for group 3. As above results, NiTi rotary instrumentation showed a trend to remain more centered in the canal than SS file instrumentation. At using NiTi file, coronal shaping with Gates Glidden drill was not statistically different from shaping with GT file. But shaping with GT file showed tapered canals, so it may be said that shaping with GT file is a safe and valuable instrumentation method.

  • PDF

Spacing of Intermediate Diaphragms Horizontally Curved Steel Box Girder Bridges considering Bending-distortional Warping Normal Stress Ratio (곡선 강박스 거더의 휨-뒤틀림 응력비에 따른 중간 다이아프램 간격)

  • Lee, Jeong-Hwa;Lee, Kee-Sei;Lim, Jeong-Hyun;Choi, Jun-Ho;Kang, Young-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6325-6332
    • /
    • 2015
  • Although distortions of horizontally curved box girder are more susceptible than which of the straight girder due to curvature effect, current domestic design standards does not present spacing of intermediate diaphragms for the curved box girder. In this study, parametric studies for straight and curved box girder considering distortional warping normal stresses based on linear finite element analysis were carried out. Single span curved girders were chosen for analysis based on current domestic bridge data with 1-6 of solid intermediate diaphragms, 0-30 degree of subtended angle, 30m and 60m of span length and 2-3m of flange width and web height. The adequate spacing of diaphragms for the box girder were suggested considering subtended angles and bending and distortional warping normal stress ratios with 5%, 10%, 15% and 20%. The analysis results were also compared to a current design standard and suggested spacing of diaphragm were evaluated.

The effect analysis of birefringence of plastic f$\heta$ Iens on the beam diameter (플라스틱 f$\heta$렌즈의 복굴절이 결상빔경에 미치는 영향분석)

  • 임천석
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.2
    • /
    • pp.73-79
    • /
    • 2000
  • We measure a beam diameter of scan and sub-scan direction of LSD (Laser Scanning Urnt) which uses $fheta$ lens produced by injecLion molding method as a scanning lens. While the measured beam diameter in scan direction, which is $62muextrm{m}$ to $68\mu\textrm{m}$, shows similar size comparing to the design beam diameter, the sub-scan beam diameter shows sIzable beam diameter deviation as much as 37 11m ranging from $78\mu\textrm{m}$ to $115\mu\textrm{m}$. Injection molding lens has the surface figure error due to the shrinkage III the cooling time and the internal distortion (birefringence) due to the uneven cooling conditIOn so that these bring about wavefront aberration (i.e., the enlargement of beam size), and are eventually expre~sed as the deterioration of the pdnting image. In this paper. we first measure and analyze beam diameter, birefringence (polanzation ratio), and asphedcal figure error of mIens in order to know the principle cause of the beam diameter deviation in sub-scan directIOn. And Lhen. through the analysis of a designed depth of focus and a calculated field curvature (imaging position of the optical axis directIon) using the above figure elTor data, we know Lhat the birefringence IS the main factor of sizable beam diameter deVIation in sub-scan direction. ction.

  • PDF

C7 Fracture as a Complication of C7 Dome-Like Laminectomy : Impact on Clinical and Radiological Outcomes and Evaluation of the Risk Factors

  • Yang, Seung Heon;Kim, Chi Heon;Lee, Chang Hyun;Ko, Young San;Won, Youngil;Chung, Chun Kee
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.4
    • /
    • pp.575-584
    • /
    • 2021
  • Objective : Cervical expansive laminoplasty is an effective surgical method to address multilevel cervical spinal stenosis. During surgery, the spinous processes of C2 and C7 are usually preserved to keep the insertion points of the cervical musculature and nuchal ligament intact. In this regard, dome-like laminectomy (undercutting of C7 lamina) instead of laminoplasty is performed on C7 in selected cases. However, resection of the lamina can weaken the C7 lamina, and stress fractures may occur, but this complication has not been characterized in the literature. The objective of the present study was to investigate the incidence and risk factors for C7 laminar fracture after C7 dome-like laminectomy and its impact on clinical and radiological outcomes. Methods : Patients who underwent cervical open-door laminoplasty combined with C7 dome-like laminectomy (n=123) were classified according to the presence of C7 laminar fracture. Clinical parameters (neck/arm pain score and neck disability index) and radiologic parameters (C2-7 angle, C2-7 sagittal vertical axis, and C7-T1 angle) were compared between the groups preoperatively and at postoperatively at 3, 6, 12, and 24 months. Risk factors for complications were evaluated, and a formula estimating C7 fracture risk was suggested. Results : C7 lamina fracture occurred in 32/123 (26%) patients and occurred at the bilateral isthmus in 29 patients and at the spinolaminar junction in three patients. All fractures appeared on X-ray within 3 months postoperatively, but patients did not present any neurological deterioration. The fracture spontaneously healed in 27/32 (84%) patients at 1 year and in 29/32 (91%) at 2 years. During follow-up, clinical outcomes were not significantly different between the groups. However, patients with C7 fractures showed a more lordotic C2-7 angle and kyphotic C7-T1 angle than patients without C7 fractures. C7 fracture was significantly associated with the extent of bone removal. By incorporating significant factors, the probability of C7 laminar fracture could be assessed with the formula 'Risk score = 1.08 × depth (%) + 1.03 × length (%, of the posterior height of C7 vertebral body)', and a cut-off value of 167.9% demonstrated a sensitivity of 90.3% and a specificity of 65.1% (area under the curve, 0.81). Conclusion : C7 laminar fracture can occur after C7 dome-like laminectomy when a substantial amount of lamina is resected. Although C7 fractures may not cause deleterious clinical outcomes, they can lead to an unharmonized cervical curvature. The chance of C7 fracture should be discussed in the shared decision-making process.