• Title/Summary/Keyword: Curtain Wall Engineering

Search Result 123, Processing Time 0.022 seconds

Forecast on Internal Condensation at Ceiling of Super-high Apartment Building Faced with Open Air (외기에 면한 초고층 아파트 천정 내부결로 예측)

  • Ahn Jae-Bong;Song Young-Woong;Choi Yoon Ki
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.626-629
    • /
    • 2003
  • This study is to forecast possible occurrence of internal condensation around parpets and H-beam located at the inside of balcony ceilings on the uppermost floor of super-high apartment buildings faced with open air in order to provide dwellers with more comfortable environment in the related space and get rid of their uneasiness about the condensation. In this study, we estimated internal condensation. which vary in accordance with humidity pressure distribution, at curtain walls, stone panels or lower parts of slabs that constitute outer space of the residence and are weak against heat, through temperature forecast and temperature distribution interpretation program at normal two-dimension temperature.

  • PDF

A Study on the Fire Protection System in the Stage (공연장의 소방시설 설치기준의 개선방안에 관한 연구)

  • 장상태;이영재
    • Fire Science and Engineering
    • /
    • v.13 no.4
    • /
    • pp.13-19
    • /
    • 1999
  • Currently, conventional fire prevention facility installation standard is based on the use and size of the domestic theaters. In the study, theaters with 1,900 seats were examined to suggest a suitable method to adapt a better fire preventing system. The proposed systems are as follow. - 100% of backup pressed-water outlet device, considering waterproof pressure for fire prevention facility at the top floor. - The supplement of the side wall type header and a large caliber outlet header for stage open sprinkler. - Subdividing a installation rule for special detector and implementing the latestdetector. - Installation of fire curtain for dividing stage area and auditorium area, and also the method of installation of fire curtain.

  • PDF

Implementing Activity-based LCA Model for Carbon Dioxide Emission Analysis and Allocation of Environment Cost (세부 공정별 CO2 배출 분석 및 환경비용 원가배분을 위한 Activity-based LCA 모델의 도입 - 커튼월 공사를 중심으로 -)

  • Lim, Ji-Youn;Yi, June-Seong;Shin, Seung-Woo;Son, Jeong-Wook
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.4
    • /
    • pp.78-88
    • /
    • 2012
  • As worldwide efforts to reduce global warming gases, the construction Industry is endeavoring to diminish carbon dioxides emissions. Especially, by introducing the LCA methodology to the industry, A variety of related studies to measure the emission of carbon dioxides have been conducted. However, when the conventional LCA methodology is applied to the construction projects, some limitations have been reported. To overcome the restrictions derived from the industry characteristics, this research suggested the Activity-based LCA model by applying the Activity-based Costing (ABC), which breaks down the whole life cycles into more detailed stages. By implementing the newly developed model, forecasting accuracy of $CO_2$ emission was elevated, and the critical control points on carbon dioxides were established. Through the case study of aluminium curtain-wall system, this research verified the usefulness of the Activity-based LCA.

An Approach on Life Cycle Based Efficiency Measurement in Construction Industry (건설 생산의 Life Cycle을 고려한 효율성 측정방안)

  • Jung Soon-Oh;Yoon Su-Won;Chin Sangyoon;Kim Yea-Sang;Park Ji-Hoon
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2004.11a
    • /
    • pp.608-611
    • /
    • 2004
  • Efficiency of the construction process is one of the most important factors to project success. However efficiency is not well defined or measured in construction projects in general. More importantly, efficiency of the construction should be viewed through the life-cycle of the whole production system not in a single phase of the construction process. Therefore, this study defines the concept of efficiency and suggests the efficiency measurement model in construction. As a case study, the suggested model was applied to the curtain wall construction process of the high rise buildings as well.

  • PDF

Assessing the Impact of RFID based materials tracking - Focusing on Curtain-Wall Work - (RFID 기반 물류 관리의 적용 효과 분석 - 커튼월 공사를 중심으로 -)

  • Yoon, Su-Won;Chin, Sang-Yoon;Kim, Yea-Sang
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.1
    • /
    • pp.24-35
    • /
    • 2012
  • RFID-based logistics is increasingly adopted in various areas of the construction industry as a technology that can improve effectiveness and efficiency of construction logistics. However, the technology is not widely adopted yet compared to the potential of RFID applications in the construction industry that the existing research has shown. Since the validation and verification of the benefit from RFID applications were biased toward the productivity of managers, more wide aspect of validation and verification is necessary. Therefore, the objective of this paper is to show how much impact the RFID-based logistics management system can have on resource leveling and allocation that have a direct impact on a construction project as well as the managers' productivity improvement that was shown by the existing research. This paper also discusses issues arisen during the test process.

Design of the Submerged Outlet Structure for Reducing Foam at a Power Plant using a Numerical Model Simulating Air Entrainment (공기연행 수치모형을 이용한 발전소 거품저감 수중방류구조 설계)

  • Kim, Ji-Young;Kang, Keum-Seok;Oh, Young-Min;Oh, Sang-Ho
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.5
    • /
    • pp.452-460
    • /
    • 2008
  • Anti-foaming agents and foam fences have been used to remove the foam at the outfall of power plants, but there are some problems as consumption of maintenance costs and insufficiency of effect. Therefore, development of the methods how to remove the foam by stable coastal structure has been required. In this study, numerical simulation of air entrainment was carried out to design the submerged outlet structure for reducing foam using curtain walls. The air entrainment rate and the discharge of entrained air change according to the shape of weir and curtain wall. Hence, it is necessary to design the optimum section through comparison of each case. The optimum section which has the maximum rate of foam reduction was determined by the simulation results. In addition, it was found that the flow velocity at the submerged outlet is to be smaller than 1 m/s and the submerged depth of curtain wall is to be taller than height of the submerged outlet section.

Development and comparative analysis of slat angle control algorithm of venetian blind according to window-to-wall ratio and zone orientation (창면적비 및 향변화에 따른 슬랫형 블라인드의 최적각도 제어 알고리즘 산출 및 비교분석)

  • Kwon, Hyuk-Ju;Lee, Keum-Ho;Lee, Kwang Ho
    • KIEAE Journal
    • /
    • v.17 no.4
    • /
    • pp.75-81
    • /
    • 2017
  • Purpose: Most contemporary office buildings supply external views, a sense of openness and a sense of time to their occupants by adopting the curtain walls, which are equipped with an outer cover having large window area. As a result, the amount of radiation increases, adversely affecting cooling load during the summer in office buildings. Although solar radiation decreases heating load and reduces energy costs during the winter period, due to the characteristics of offices where occupants work largely during daytime, the cooling load is important compared to the heating. Therefore, diverse measures to resolve those trade-offs and annual energy cost have been investigated. Method: In this study, the annual thermal load was comparatively analyzed according to the slat angle of the venetian blind along with lighting control technique. Result: After selecting effective conditions, in order to resolve such issues, this study established automated control strategies of slat angle depending on the window-to-wall ratio and zone orientation, so that the findings of this study can be effectively generalized to other circumstances.

Stability Analysis of Upper Structures by Soil Grouting (지반 그라우팅에 의한 상부구조물의 안전성 분석)

  • Hwang, Chulsung
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.4
    • /
    • pp.58-65
    • /
    • 2013
  • Transportation and further expansion of social infrastructure was needed along the development of urbanization and population concentration. To use the underground space due to the lack of availability of land, it is inevitable to intersect between present structure and tunnel during construction. Soil grouting is one of the ground improvement methods to reinforce weak soil around the underground structures by injection of grouting liquid. Some of central columns of an upper structure are damaged during injection of grouting liquid by injection pressure. To investigate and improve the stability of the tunnel, three dimensional analysis are performed with full construction stages which includes the construction of present underpass, damaging columns of the underpass, reinforcing the columns by H-pile and shear walls, and excavation and construct tunnel. The arrangement of grouting holes such as curtain and horizontal type affects largely to the stability of upper structure and horizontal arrangement diminish the shear forces which is the cause of damage of central columns. The liquid injection type of reinforcement for tunnel is not recommended while the presence of upper structure with columns. Wall type reinforcing is utilize for permant support of upper structures which is affected by grouting injection pressure. H-pile is utilize for temporary support, but not for permanent since the sharing of shear forces is not much to shear wall during tunnel construction.

FE assessment of dissipative devices for the blast mitigation of glazing façades supported by prestressed cables

  • Amadioa, Claudio;Bedon, Chiara
    • Structural Engineering and Mechanics
    • /
    • v.51 no.1
    • /
    • pp.141-162
    • /
    • 2014
  • The paper focuses on the dynamic response of a blast-invested glass-steel curtain wall supported by single-way pretensioned cables. In order to mitigate the critical components of the façade from severe structural damage, an innovative system able to absorb and dissipate part of the blast-induced stresses in the critical façade components is proposed. To improve the blast reliability of the studied glazing system, specifically, rigid-plastic and elastoplastic devices are introduced at the base and at the top of the vertical bearing cables. Several combinations and mechanical calibrations of these devices are numerically investigated and the most structurally and economically advantageous solution is identified. In conclusion, a simple analytical formulation totally derived from energetic considerations is also suggested for a preliminary estimation of the maximum dynamic effects in single-way cable-supported façades subjected to high-level blast loads.

A Study on IDM Development for Automation of BIM-based Architectural Facade Design - Focused on Musical Proportion - (BIM기반 건축 파사드 디자인 자동화를 위한 IDM 개발에 관한 연구 - 음계비례를 중심으로 -)

  • Heo, Kyu-Souk;Choo, Seung-Yeon
    • Korean Journal of Computational Design and Engineering
    • /
    • v.15 no.5
    • /
    • pp.393-402
    • /
    • 2010
  • Existing construction industry is composed of several processes with various characteristics. The tendency of current construction industry is getting complicated and diversified; it has limitation to solve problems through existing processes. As a problem-solving method, BIM (Building Information Modeling), environment to manage building life cycle from design and construction to management, is being suggested. Currently, BIM is only focused on technology development by engineers, and the automation of architectural theories is insufficiency except architectural design modeling. Therefore, this research aims to back up theses drawbacks through intellectual curtain wall arrangement by using musical proportions. In order to apply to construction automation, analysised of musical proportions method are performed. The BPMN-based Process Map is listed to develop IDM for the application to BIM Software.