• Title/Summary/Keyword: Curtain

Search Result 565, Processing Time 0.025 seconds

Structural Stability, Weathering and Conservation Method of Granite Standing Sculptured Buddha at Hwangsang-dong, Kumi (구미 황상동 마애여래입상의 구조적 안정성, 풍화 및 보존방안)

  • Lee, Chan Hee;Choi, Suck Won;Suh, Mancheol;Chae, Sang Jeong
    • Journal of Conservation Science
    • /
    • v.9 no.1
    • /
    • pp.21-32
    • /
    • 2000
  • Rock composition of the Hwangsang-dong Granite Standing Sculptured Buddha (Treasure No. 1122) in the Kumi City is biotite-hornblende granodiorite which consists of about 30 pieces of individual rock blocks of same compositions. However, the cap rocks is pebble-bearing coarse sandstone. Rock blocks of the Standing Buddha and surrounding out crops occur well developed several joint systems of $N25^{\circ}$ to $45^{\circ}W$ strike and nearly vertical (70 to $85^{\circ}SE$) dipping. Rock blocks of the Standing Buddha showed vertical, horizontal and oblique joints, and those blocks are well supported by individual blocks. However, the junction part of the blocks are under dangerous situation due 10 seriously mechanical and chemical weathering. Host rock of the Standing Buddha belongs to the HW grade, therefore mostly rock-forming minerals of the granodiorite Standing Buddha altered with clay and iron hydroxide minerals by mineralogical and chemical weathering. Near surface of the Standing Buddha show spore and mycelium of green algaes, and a joint plane alive with weeds. We suggest that if structural stability for the Standing Buddha remove essentially a unstable rock blocks from the main body, and the main body necessitate supporting by rock bolting method because of repeated unstability and minimizing stress to the rock blocks. For the opened joint planes, fractured surface and alive weeds will attempt to fill in a petro-epoxy, petro-filler and biochemical treatments for the algaes, and ground water curtain and wall seems to be necessary for water flow and diminishing humidity of the Standing Buddha.

  • PDF

A Numerical Study for Calculation of Overall Heat Transfer Coefficient of Double Layers Covering and Insulation Material for Greenhouse (온실용 이중피복 및 보온재의 관류열전달계수 산정을 위한 수치적 연구)

  • Lee, Jong-Won;Kim, Dong-Keon;Lee, Hyun-Woo
    • Current Research on Agriculture and Life Sciences
    • /
    • v.33 no.2
    • /
    • pp.41-47
    • /
    • 2015
  • This study calculated the overall heat transfer coefficient (U-value) of greenhouse covering materials with thermal screens using a simulation model and then estimated the validity of the calculated results by comparison with measured values. The U-value decreased gradually as the thickness of the air space between the double glazing increased, and then remained essentially constant at thicknesses exceeding 25 mm. The U-value also increased with the difference in temperature between the inside and outside of the hot box. The vigorous convective heat transfer between two plastic films caused unsteady heat flow and then created a nonlinear temperature distribution in the air space. The distance did not affect the U-value at distances of 50~200 mm between the plastic covering and thermal curtain. The numerical calculation results, with and without sky radiation, were in accord with the experimental results for a $30^{\circ}C$ temperature difference between the inside and outside of the hot box. In conclusion, a reliable U-value can be calculated for a temperature difference of $30^{\circ}C$ or more between the inside and outside of the hot box.

Field Survey on the Structure and Manure Treatment of Two-Storey and Sawdust Pig Houses in Korea (국내 2층 돈사와 톱밥돈사의 구조 및 분뇨처리 실태조사)

  • Jeong J. W.;Yoo Y. H.;Song J. I.;Kim T. I.;Jeon B. S.;Yang C. B.
    • Journal of Animal Environmental Science
    • /
    • v.11 no.3
    • /
    • pp.169-176
    • /
    • 2005
  • The farm house structure, ventilation system and manure treatment of two-storey buildings and sawdust pig houses were surveyed and analyzed. Based on the data for ten selected farms in five provinces during eight months, the goal is to eventually establish a standard two-storey pig house. Manure treatments were composting, slurry and activated sludge in two-storey pig houses, while fermentation method was done in sawdust pig house. The depth of sawdust as a litter material were 10 to 60cm, with a duration of 1/2, 1, 3 and 6 months, respectively. The ventilation systems were the mechanical type in two-storey pig houses and natural system in the sawdust pig house. Side wall in the two-storey pig house was enclosed with insulation materials such as block, colored metal sheet and sandwich panels. The minimum ceiling height in the first floor of the two-storey pig house was 2.0m and the maximum was 3.0m. On the second floor, ceiling height ranged from 2.0 to 2.7m. The construction cost in the two-storey systems were $700\~140$, and sidewall curtain systems were $30\~40$ thousand Won/pyung.

  • PDF

Estimation of Surplus Solar Energy in Greenhouse (I) - Case Study Based on 1-2W Type - (온실내 잉여 태양에너지 산정 (I) - 1-2W형을 중심으로 -)

  • Suh, Won-Myung;Bae, Yong-Han;Ryou, Young-Sun;Lee, Sung-Hyoun;Yoon, Yong-Cheol
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.5
    • /
    • pp.79-86
    • /
    • 2009
  • This research performed to analyze surplus solar energy, which is generated from a greenhouse during daytime, and to make the basic materials for designing thermal energy storage system for surplus solar energy. For this goal, it analyzed the surplus solar energy coming from two types of greenhouse. The results of this research are as per the below: In the case of 1-2W-type greenhouse, this research gave the same temperature and ventilation condition regardless of regions, but it was judged that the quantity of surplus solar energy could be greatly changed, depending on the energy consumed for the photosynthesis and evapotranspiration of crops in the greenhouse, on the heating temperature during daytime and night, on the existence/non-existence of a curtain and its warming effect, and on the ventilation temperature suitable for the overcoming of high temperature troubles or for the optimum cultivation temperature. In the case of a single-span greenhouse, there was a big difference in energy incoming and outgoing by month, but throughout seasons, 85.0 % of the total energy put into the greenhouse was solar energy and the energy input by heating was just 15.0 % of the total. 26.4 % of the total energy input for the greenhouse was used for photosynthesis and evapotranspiration of crops, and 44.2 % of the remaining 73.6 % went out in the form of radiant heat through the surface of the greenhouse. That is, 25.2 % of the total energy loss was just the surplus solar energy. 67.6 % of the total heating energy was concentrically used for 3 months from December to February next year, but the surplus solar energy during the same period was just 19.4 % of the total annual quantity so it was found that the given condition was more restrictive in directly converting the surplus heat into greenhouse heating. Under the disadvantageous circumstance of 3 months from December to February next year, it was possible to supplement 28 % (December) $\sim$ 85 % (February) of heating energy with surplus solar energy.

Current on the Heat Loss in Greenhouses during Winter Season - Case Study Based on Gyeongnam Area - (동절기 온실의 열 손실에 관한 실태조사 - 경남지역을 중심으로 -)

  • Im, Jae Un;Yun, Sung Wook;Kim, Hyeon Tae;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.22 no.1
    • /
    • pp.73-79
    • /
    • 2013
  • An experiment was conducted to study incidences of heat loss in greenhouse in Gyeongnam province using thermal imaging camera in order to determine ways minimizing greenhouse heat loss. Measurements of this work showed that temperature differences between two experiment zones before and after installation of thermal curtains were about $2.0{\sim}3.0^{\circ}C$ and $1.0{\sim}2.0^{\circ}C$ respectively. There was a high correlation between the temperature data measured using a thermal imaging camera and a temperature sensor. There was no serious difference among areas, but between places on the first and second floor with thermal curtains for heat insulation, there was a relatively larger heat loss on the first floor than the second floor. Then in general the greenhouse types had no particular bearing on this matter, there was a relatively large heat loss in the parts of side wall window, the gaps and the parts folded of horizontal thermal curtains, the gutter parts, and the gaps of thermal curtain in the side wall window and facade back side for heat insulation, aren't completely sealed. It was found that there was a substantial heat loss due to infiltration through cracks on covering material, doors, ventilating openings, roof gables and floors, in particular.

An Air Cleaning Efficiencies of Wet Air Cleaner in the Swine Finishing Winch Curtain Stall (윈치커튼식 비육돈사에서 습식공기정화기의 공기정화 효율 분석)

  • Oh, I.H.;Kim, W.G.;Lee, H.S.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.2
    • /
    • pp.75-80
    • /
    • 2008
  • High concentration of $NH_3$, $CO_2$, and lots of dust are found in modern densely raising stall system, as results, they provide a negative influence on animal and lamer health, and production ability. Therefore, it is necessary to keep clean the inside of stall air to increase the productivity. A wet type air cleaner has been developed to clean the stall air. The work principle is that the inside air are sucked through the fan, and the rotating discs make a water into a fineness spray and blows into the stall. The spray can take the dust, $NH_3$, and odor from the stall inside air and give back to the circulating water, which can be refreshed in 2 hours interval. In the Present study, we measured the $NH_3$, dust, odor, temperature and humidity in a swine stall that were installed two wet air cleaners with 700 fattening swine with on-mode and off-mode of wet air cleaners. In fall, the concentrations of $NH_3$ in off-mode stall were maximum 24 ppm and minimum 16 prm, and the average was 18.2 ppm. However in on-mode stall the $NH_3$ concentrations were maximum 7ppm and minimum 1ppm, and the average was 2.7ppm. The concentration of $NH_3$ in on-mode was 74% lower than off-mode stall. Odor was measured by olfactometer. In the off-mode stall, the odor unit was 3,800 OU/$m^3$, but in the on-mode stall the odor unit was 2,100 OU/$m^3$ Odor removal efficiency was about 45% in on-mode stall. The dust measure was divided into 3 categories, $PM_{10}$, $PM_{2.5}$ and $PM_{1.0}$. Whereas the $PM_{10}$ showed no significant differences between the tests, $PM_{2.5}$ and $PM_{1.0}$ in the fine particle range reduced remarkably in the on-mode.

  • PDF

Comparison of Heat Insulation Characteristics of Multi-layer Thermal Screen and Development of Curtain System (다겹보온자재의 보온성 비교 및 커튼개폐장치 개발)

  • Lee, Si-Young;Kim, Hark-Joo;Chun, Hee;Yum, Sung-Hyun;Lee, Hyun-Joo
    • Journal of Bio-Environment Control
    • /
    • v.16 no.2
    • /
    • pp.89-95
    • /
    • 2007
  • This study was accomplished to compare energy saving effects of several heat insulation materials in greenhouse and to develop new automatic opening and closing equipment which is suitable to the most effective heat insulation material. To find out more effective heat insulation material, the magnitude of heat transfer occurred through aluminum screen (ALS), non-woven fabric (NWF), double-layer aluminum screen with chemical cotton sheet (DAL), and multi-layer fabric screen material quilted with non-woven fabric, chemical cotton, poly foam, and polypropylene (MLF) were compared relatively. The results showed that the relative magnitude of heat transfer occurred through MLF was lower than DAL and ALS by 23.3% and 43.0% respectively. MLF screen material was the most effective compared with other heat insulation materials. But because of thickness, there was a need of new mechanism for automatic operation in greenhouse. Accordingly, new screen system using MLF-thick but profitable for keeping warm in greenhouse-was developed. Opening & closing equipment was designed to roll MLF with pipe axis during opening process and pull MLF with string during closing process with electric motors, clutches, drums, and so on. In hot pepper cultivation and energy saving test during winter time, the early stage yield of pepper under MLF screen system was higher than NWF by 27%, and gasoline consumption of MLF screen system was lower than NWF by 46%.

Relationship between Hydrochemical Variation of Groundwater and Gas Tigtness in the Underground Oil Storage Caverns (지하원유비축기지 공동주변 지하수의 수질화학적 변화와 기밀성과의 관계)

  • Jeong Chan Ho
    • The Journal of Engineering Geology
    • /
    • v.14 no.3 s.40
    • /
    • pp.259-272
    • /
    • 2004
  • The purpose of this study is to investigate the effect of hydrochemical variation of groundwater on the gas tigtness in an unlined oil storage cavern. The groundwater chemistry is greatly influenced by the seawater mixing, the water curtain and the dissolution of grounting cements. The chemical composition of groundwater greatly varies ac-cording to both the location of monitoring wells and the sampling period. Most of groundwater shows alkaline pH and high electrical conductivity. The chemical types of groundwater show the dominant order as follows : Na-Cl type > Ca-Cl type > $Ca-HCO_3(CO_3)$ type. Thermodynamic equilibrium state between chemical composition of groundwater and major minerals indicates that carbonate minerals except clay minerals can be precipitated as a secondary mineral. It means that the secondary precipitates can not greatly exerts the clogging effect into fracture aperture in rock mass around oil storage cavern. The content of total organic carbon (TOC) shows a slightly increasing trend from initial stage to late stage. The $EpCO_2$ was computed so as to assess the gas contribution on the $CO_2$ in groundwater. The $EpCO_2$ of 0$\~$41.3 indicates that the contribution of oil gas on $CO_2$ pressure in groundwater system can be neglected.

Characterization of Area Installing Combined Geothermal Systems : Hydrogeological Properties of Aquifer (복합지열시스템에 대한 부지특성화: 대수층의 수리지질학적 특성)

  • Mok, Jong-Koo;Park, Yu-Chul;Park, Youngyun;Kim, Seung-Kyum;Oh, Jeong-Seok;Seonwoo, Eun-Mi
    • The Journal of Engineering Geology
    • /
    • v.27 no.3
    • /
    • pp.293-304
    • /
    • 2017
  • This study was performed in order to hydrogeological analysis of aquifer, which is a necessary part for evaluating the efficiency of the combined well and open-closed loops geothermal (CWG) systems. CWG systems have been proposed for the effective utilization of geothermal energy by combining open loop geothermal systems and closed loop geothermal systems. Small aperture CWG systems and large aperture CWG systems were installed at a green house land with water curtain facilities in Chungju City. Aquifer tests include pumping tests and step-drawdown tests were conducted to analyse hydrogeological characteristics of aquifer in the study area. The transmissivity was estimated in the range of $13.49{\sim}58.99cm^2/sec$, and the storativity was estimated in the range of $1.13{\times}10^{-5}{\sim}5.20{\times}10^{-3}$. The geochemical analysis showed $Ca^{2+}$ ion and ${HCO_3}^-$ ion were dominant in groundwater. The Langelier Saturation Index and the Ryznar Stability Index showed low scaling potential of groundwater. In the analysis of vertical water temperature change, the geothermal gradient was estimated as $2.1^{\circ}C/100m$, which indicated the aquifer was enough for geothermal systems. In conclusion, groundwater is rich, can stably use geothermal heat, and it is less likely to cause deterioration of thermal energy efficiency by precipitation of carbonate minerals in study area. Therefore, the study area is suitable for installation of the combined geothermal system.

Study on the Physical Property of Thermal Curtains for Greenhouse (시설하우스용 보온커튼재의 물리적 특성에 관한 연구)

  • 장유섭;오권영;김승희;전종길;강금춘;정두호
    • Journal of Bio-Environment Control
    • /
    • v.5 no.1
    • /
    • pp.34-42
    • /
    • 1996
  • This study was conducted to investigate the physical and optical properties of polypropylene and polyester thermal curtains, in which tensile strength, heat reservance and light transmission of two different materials were measured. The results from this study are as follows. 1. The tensile weight of different materials were ranged from 3.4kg to 13.4kg, according to the thickness of materials, but that no difference in the tensile strength was appeared between the two materials. The Elongation of polypropylene materials and the tensile weight and strength of polyester materials were greater than any other materials. 2. The light transmittances of two materials were ranged from 50.3% to 81.7 %, light transmittances in polypropylene were higher by 20-30%,than those in polyester. 3. The heat reservances of two materials were ranged from 18.2% to 41.2%, in which polypropylene showed better performance than polyester. 4. From the results of the test, the polypropylene thermal material was better in elongation, heat reservances and light transmittances, but polyester thermal material was better in tensile strength and light isolation than the other material.

  • PDF