• Title/Summary/Keyword: Current sampling error

Search Result 73, Processing Time 0.023 seconds

A Novel Control Strategy on UPS output Voltage distortion by Rectifier Load (정류성 부하에 의한 UPS출력전압 왜형 보상을 위한 새로운 제어 기법)

  • Sung, Byoung-Mo;Park, Sung-Jun;Park, Han-Woong;Kim, Cheul-U
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1218-1220
    • /
    • 2000
  • A new control technique is proposed to reduce the distortion of UPS output voltage. The Load of UPS is rectifier which has many harmonics on its output current in many cases. The distortion of output voltage by the harmonics is repeated at the same position in one cycle. Therefore we can assume that the next cycle wave form would be similar to the previous one. The repeated error can be estimated and be compensated by the Multi controller at every sampling times.

  • PDF

Performance Analysis of Blind Channel Estimation for Precoded Multiuser Systems

  • Xu, Zhengyuan
    • Journal of Communications and Networks
    • /
    • v.4 no.3
    • /
    • pp.189-198
    • /
    • 2002
  • Precoder has been shown to be able to provide source diversity and design flexibility. In this paper we employ precoding techniques for block transmission based on a multirate filterbank structure. To accommodate multiuser communication with variable data rates, different precoders with corresponding coefficients and up/down sampling rates are used. However, due to unknown multipath distortion, different interferences may exist in the received data, such as multiuser interference, intersymbol interference and interblock interference. To estimate channel parameters for a desired user, we employ all structured signature waveforms associated with different symbols of that user and apply subspace techniques. Therefore better performance of channel estimator can be achieved than the conventional subspace method based only on the signature of the current symbol. The delay for that user can also be jointly estimated. Channel identifiability conditions and asymptotic channel estimation error are investigated in detail. Numerical examples are provided to justify the proposed method. gest either multicode (MC) or multiple processing gain (MPG) mechanism [2], while requiring data rates to be integral multiples of some basic low-rate. In order to support variable rate transmission however, a comprehensive scheme needs to be investigated.

Item sum techniques for quantitative sensitive estimation on successive occasions

  • Priyanka, Kumari;Trisandhya, Pidugu
    • Communications for Statistical Applications and Methods
    • /
    • v.26 no.2
    • /
    • pp.175-189
    • /
    • 2019
  • The problem of the estimation of quantitative sensitive variable using the item sum technique (IST) on successive occasions has been discussed. IST difference, IST regression, and IST general class of estimators have been proposed to estimate quantitative sensitive variable at the current occasion in two occasion successive sampling. The proposed new estimators have been elaborated under Trappmann et al. (Journal of Survey Statistics and Methodology, 2, 58-77, 2014) as well as Perri et al. (Biometrical Journal, 60, 155-173, 2018) allocation designs to allocate long list and short list samples of IST. The properties of all proposed estimators have been derived including optimum replacement policy. The proposed estimators have been mutually compared under the above mentioned allocation designs. The comparison has also been conducted with a direct method. Numerical applications through empirical as well as simplistic simulation has been used to show how the illustrated IST on successive occasions may venture in practical situations.

Improved Iterative Method for Wavefront Reconstruction from Derivatives in Grid Geometry

  • Nguyen, Vu-Hai-Linh;Rhee, Hyug-Gyo;Ghim, Young-Sik
    • Current Optics and Photonics
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • This paper proposes a robust, simple zonal wavefront-estimation method in a grid sampling model. More slopes are added to the integral equation of the algorithm to improve the accuracy and convergence rate of this approach, especially for higher-order optical aberrations. The Taylor theorem is applied to clarify the mathematical description of the remaining error in the proposed method. Several numerical simulations are conducted to ensure the performance and improvement in comparison to the Southwell and previous algorithm. An experiment is also conducted according to deflectometry output and the results are verified using a reference measured with a stylus system.

An Algorithm for Optimized Accuracy Calculation of Hull Block Assembly (선박 블록 조립 후 최적 정도 계산을 위한 알고리즘 연구)

  • Noh, Jac-Kyou
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.5
    • /
    • pp.552-560
    • /
    • 2013
  • In this paper, an optimization algorithm for the block assembly accuracy control assessment is proposed with consideration for the current block assembly process and accuracy control procedure used in the shipbuilding site. The objective function of the proposed algorithm consists of root mean square error of the distances between design and measured data of the other control points with respect to a specific point of the whole control points. The control points are divided into two groups: points on the control line and the other points. The grouped data are used as criteria for determining the combination of 6 degrees of freedom in the registration process when constituting constraints and calculating objective function. The optimization algorithm is developed by using combination of the sampling method and the point to point relation based modified ICP algorithm which has an allowable error check procedure that makes sure that error between design and measured point is under allowable error. According to the results from the application of the proposed algorithm with the design and measured data of two blocks data which are verified and validated by an expert in the shipbuilding site, it implies that the choice of whole control points as target points for the accuracy calculation shows better results than that of the control points on the control line as target points for the accuracy of the calculation and the best optimized result can be acquired from the accuracy calculation with a fixed point on the control line as the reference point of the registration.

Robust Double Deadbeat Control of Single-Phase UPS Inverter (단상 UPS 인버터의 강인한 2중 데드비트제어)

  • 박지호;허태원;안인모;이현우;정재륜;우정인
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.65-72
    • /
    • 2001
  • This paper deals with a novel full digital control of the single-phase PWM(Pulse Width Modulation) inviter for UPS(Uninterruptible Power Supp1y). The voltage and current of output filter capacitor as a state variable are the feedback control input. In the proposed scheme a double deadbeat control consisting of minor current control loop and major voltage control loop have been developed In addition, a second order deadbeat currents control which should be exactly equal to its reference in two sampling time without error and overshoot is proposed to remove the influence of the calculation time delay. The load current prediction is achieved to compensate the load disturbance. The simulation and experimental result shows that the proposed system offers an output voltage with THD(Total Harmonic Distortion) less than 5% at a full nonlinear load.

  • PDF

Design of a 2.5V 10-bit 300MSPS CMOS D/A Converter (2.5V 10-bit 300MSPS 고성능 CMOS D/A 변환기의 설계)

  • Kwon, Dae-Hoon;Song, Min-Kyu
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.7
    • /
    • pp.57-65
    • /
    • 2002
  • In this paper, a 2.5V 10-bit 300MSPS CMOS D/A Converter is described. The architecture of the D/A Converter is based on a current steering 8+2 segmented type, which reduces non-linearity error and other secondary effects. In order to achieve a high performance D/A Converter, a novel current cell with a low spurious deglitchnig circuit and a novel inverse thermomeer decoder are proposed. To verify the performance, it is integrated with $0.25{\mu}m$ CMOS 1-poly 5-metal technology. The effective chip area is $1.56mm^2$ and power consumption is about 84mW at 2.5V power supply. The simulation and experimental results show that the glitch energy is 0.9pVsec at fs=100MHz, 15pVsec at fs=300MHz in worst case, respectively. Further, both of INL and DNL are within ${\pm}$1.5LSB, and the SFDR is about 45dB when sampling, frequency, is 300MHz and output frequency is 1MHz.

Identification of Factors Affecting Errors of Velocity Calculation on Application of MLSPIV and Analysys of its Errors through Labortory Experiment (MLSPIV를 이용한 유속산정시 오차요인 규명 및 실내실험을 통한 유속산정오차 분석)

  • Kim, Young-Sung;Lee, Hyun-Seok
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.2
    • /
    • pp.153-165
    • /
    • 2010
  • Large-Scale Particle Image Velocimetry (LSPIV) is an extension of particle image velocimetry (PIV) for measurement of flows spanning large areas in laboratory or field conditions. LSPIV is composed of six elements - seeding, illumination, recording, image transformation, image processing, postprocessing - based on PIV. Possible error elements at each step of Mobile LSPIV (MLSPIV), which is a mobile version of LSPIV, in field applications are identified and summarized the effect of the errors which were quantified in the previous studies. The total number of elemental errors is 27, and five error sources were evaluated previously, seven elemental errors are not effective to the current MLSPIV system. Among 15 elemental errors, four errors - sampling time, image resolution, tracer, and wind - are investigated through an experiment at a laboratory to figure out how those errors affect to velocity calculation. The analysis to figure out the effect of the number of images used for image processing on the velocity calculation error shows that if over 50 images or more are used, the error due to it goes below 1 %. The effect of the image resolution on velocity calculation was investigated through various image resolution using digital camera. Low resolution image set made 3 % of velocity calculation error comparing with high resolution image set as a reference. For the effect of tracers and wind, the wind effect on tracer is decreasing remarkably with increasing the flume bulk velocity. To minimize the velocity evaluation error due to wind, tracers with high specific gravity is favorable.

Generalized cross correlation with phase transform sound source localization combined with steered response power method (조정 응답 파워 방법과 결합된 generalized cross correlation with phase transform 음원 위치 추정)

  • Kim, Young-Joon;Oh, Min-Jae;Lee, In-Sung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.5
    • /
    • pp.345-352
    • /
    • 2017
  • We propose a methods which is reducing direction estimation error of sound source in the reverberant and noisy environments. The proposed algorithm divides speech signal into voice and unvoice using VAD. We estimate the direction of source when current frame is voiced. TDOA (Time-Difference of Arrival) between microphone array using the GCC-PHAT (Generalized Cross Correlation with Phase Transform) method will be estimated in that frame. Then, we compare the peak value of cross-correlation of two signals applied to estimated time-delay with other time-delay in time-table in order to improve the accuracy of source location. If the angle of current frame is far different from before and after frame in successive voiced frame, the angle of current frame is replaced with mean value of the estimated angle in before and after frames.

Development of Constant Output Power Supply System for Ozonizer (오존발생장치용 정출력 전원장치의 개발)

  • Woo, Jung-In;Woo, Sung-Hoon;Roh, In-Bae;Park, Jee-Ho;Kim, Dong-Wan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.7
    • /
    • pp.113-121
    • /
    • 2005
  • In this paper, a constant output power supply system for ozonizer is proposed to remove the noise of ozonizer and control the output of ozonizer using feedback control. The proposed system is based on the rouble control loop such as the outer voltage control loop and inner current control loop. In the proposed system overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The inner current control loop is adopted by an internal model controller. The internal model controller is designed to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. The outer voltage control loop employing P-Resonance controller is proposed. The resonance controller has an infinite gain at resonant frequency, and the resonant frequency is set to the fundamental frequency of the reference voltage in this paper. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been verified by the experimental results.