• Title/Summary/Keyword: Current imbalance

Search Result 209, Processing Time 0.026 seconds

Coupled Inductor Based Voltage Balancing in Dual-Output CLL Resonant Converter for Bipolar DC Distribution System (양극성 DC 배전 시스템 적용을 위한 결합 인덕터 기반의 전압 밸런싱 이중 출력 CLL 공진형 컨버터)

  • Lee, Seunghoon;Kim, Jeonghun;Cha, Honnyong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.4
    • /
    • pp.348-355
    • /
    • 2022
  • A bipolar DC distribution system suffers from an imbalance in voltages when asymmetric loads are connected at the outputs. Dedicated voltage balancers are required to address the imbalance in bipolar voltage levels. However, additional components eventually increase the cost and decrease the efficiency and power density of the system. Therefore, to deal with the imbalance in output voltages without adding any extra components, this study presents a coupled inductor-based voltage balancing technique with a dual-output CLL resonant converter. The proposed coupled inductor does not require extra magnetic components to balance the output voltages because it is the result of resonant inductors of the CLL tank circuit. It can also avoid complex control schemes applied to voltage balancing. Moreover, with the proposed coupled inductor, the CLL converter acquires good features including zero voltage and zero current switching. Detailed analysis of the proposed coupled inductor is presented with different load conditions. A 3.6-kW hardware prototype was built and tested to validate the performance of the proposed coupled inductor-based voltage balancing technique.

Anti-inflammatory Action of Calorie Restriction for Life-Prolongation: A Possible Mechanism

  • Chung, Hae-Young
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.173-174
    • /
    • 2002
  • Oxidative modification of cellular structures and functions by redox imbalance is the basis of the current oxidative stress hypothesis of aging. The experimental support for this hypothsis has been generated from recent molecular probing on the interrelation between the age-related functional impairments and the pathogenesis. (omitted)

  • PDF

Current Sharing Control Strategy for IGBTs Connected in Parallel

  • Perez-Delgado, Raul;Velasco-Quesada, Guillermo;Roman-Lumbreras, Manuel
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.769-777
    • /
    • 2016
  • This work focuses on current sharing between punch-through insulated gate bipolar transistors (IGBTs) connected in parallel and evaluates the mechanisms that allow overall current balancing. Two different control strategies are presented. These strategies are based on the modification of transistor gate-emitter control voltage VGE by using an active gate driver circuit. The first strategy relies on the calculation of the average value of the current flowing through all parallel-connected IGBTs. The second strategy is proposed by the authors on the basis of a current cross reference control scheme. Finally, the simulation and experimental results of the application of the two current sharing control algorithms are presented.

LSTM based Supply Imbalance Detection and Identification in Loaded Three Phase Induction Motors

  • Majid, Hussain;Fayaz Ahmed, Memon;Umair, Saeed;Babar, Rustum;Kelash, Kanwar;Abdul Rafay, Khatri
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.1
    • /
    • pp.147-152
    • /
    • 2023
  • Mostly in motor fault detection the instantaneous values 3 axis vibration and 3phase current in time domain are acquired and converted to frequency domain. Vibrations are more useful in diagnosing the mechanical faults and motor current has remained more useful in electrical fault diagnosis. With having some experience and knowledge on the behavior of acquired data the electrical and mechanical faults are diagnosed through signal processing techniques or combine machine learning and signal processing techniques. In this paper, a single-layer LSTM based condition monitoring system is proposed in which the instantaneous values of three phased motor current are firstly acquired in simulated motor in in health and supply imbalance conditions in each of three stator currents. The acquired three phase current in time domain is then used to train a LSTM network, which can identify the type of fault in electrical supply of motor and phase in which the fault has occurred. Experimental results shows that the proposed single layer LSTM algorithm can identify the electrical supply faults and phase of fault with an average accuracy of 88% based on the three phase stator current as raw data without any processing or feature extraction.

PFC Controller Design for 3-Phase Modular UPS (3상 모듈형 UPS용 PFC 제어기 설계)

  • Park, Nae Chun;Kim, Sang Hoon;Ji, Jun Keun
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.44-45
    • /
    • 2010
  • In this paper a new PFC Controller for 3-Phase Modular UPS is proposed. The PFC circuit for 3-Phase Modular UPS is implemented using three 1-phase 3-level boost PFC circuits. To control DC output voltage and AC input current, single voltage controller considering imbalance of two capacitor voltages and three independent current controllers are used in proposed PFC controller.

  • PDF

Power Quality Improvement for Grid Connected Inverters under Distorted and Unbalanced Grids

  • Kim, Hyun-Sou;Kim, Jung-Su;Kim, Kyeong-Hwa
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1578-1586
    • /
    • 2016
  • A power quality improvement scheme for grid connected inverters, even in the presence of the disturbances in grid voltages due to harmonic distortions and three-phase imbalance, is presented for distributed generation (DG) power systems. The control objective is to force the inverter currents to follow their references with robustness even under external disturbances in grid voltages. The proposed scheme is realized by a disturbance observer (DOB) based current control scheme. Since the uncertainty in a system can be effectively canceled out using an estimated disturbance by the DOB, the resultant system behaves like a closed-loop system consisting of a disturbance-free nominal model. For experimental verification, a 2 kVA laboratory prototype of a grid connected inverter has been built using a digital signal processor (DSP) TMS320F28335. Through comparative simulations and experimental results under grid disturbances such as harmonic distortion and imbalance, the effectiveness of the proposed DOB based current control scheme is demonstrated.

Droop Control Scheme of a Three-phase Inverter for Grid Voltage Unbalance Compensation

  • Liu, Hongpeng;Zhou, Jiajie;Wang, Wei;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1245-1254
    • /
    • 2018
  • The stability of a grid-connected system (GCS) has become a critical issue with the increasing utilization of renewable energy sources. Under grid faults, however, a grid-connected inverter cannot work efficiently by using only the traditional droop control. In addition, the unbalance factor of voltage/current at the common coupling point (PCC) may increase significantly. To ensure the stable operation of a GCS under grid faults, the capability to compensate for grid imbalance should be integrated. To solve the aforementioned problem, an improved voltage-type grid-connected control strategy is proposed in this study. A negative sequence conductance compensation loop based on a positive sequence power droop control is added to maintain PCC voltage balance and reduce grid current imbalance, thereby meeting PCC power quality requirements. Moreover, a stable analysis is presented based on the small signal model. Simulation and experimental results verify the aforementioned expectations, and consequently, the effectiveness of the proposed control scheme.

Design Methodology for Transformers Including Integrated and Center-tapped Structures for LLC Resonant Converters

  • Jung, Jee-Hoon;Choi, Jong-Moon;Kwon, Joong-Gi
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.215-223
    • /
    • 2009
  • A design methodology for transformers including integrated and center-tapped structures for LLC resonant converters is proposed. In the LLC resonant converter, the resonant inductor in the primary side can be merged in the transformer as a leakage inductance. And, the absence of the secondary filter inductor creates low voltage stress on the secondary rectifiers and is cost-effective. A center-tapped structure of the transformer secondary side is widely used in commercial applications because of its higher efficiency and lower cost than full-bridge structures in the rectifying stages. However, this transformer structure has problems of resonance imbalance and transformer inefficiency caused by leakage inductance imbalance in the secondary side and the position of the air-gap in the transformer, respectively. In this paper, gain curves and soft-switching conditions are derived by first harmonic approximation (FHA) and operating circuit simulation. In addition, the effects of the transformer including integrated and center-tapped structures are analyzed by new FHA models and simulations to obtain an optimal design. Finally, the effects of the air-gap position are analyzed by an electromagnetic field simulator. The proposed analysis and design are verified by experimental results with a 385W LLC resonant converter.

Average Current Control for Parallel Connected Converters

  • Jassim, Bassim M.H.;Zahawi, Bashar;Atkinson, David J.
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1153-1161
    • /
    • 2019
  • A current sharing controller is proposed in this paper for parallel-connected converters. The proposed controller is based on the calculation of the magnitudes of system current space vectors. Good current distribution between parallel converters is achieved with only one Proportional-Integral (PI) compensator. The proposed controller is analyzed and the circulating current impedance is derived for paralleled systems. The performance of the new control strategy is experimentally verified using two parallel connected converters employing Space Vector Pulse Width Modulation (SVPWM) feeding a passive RL load and a 2.2 kW three-phase induction motor load. The obtained test results show a reduction in the current imbalance ratio between the converters in the experimental setup from 53.9% to only 0.2% with the induction motor load.

Effects of Induced Abortion and Son Preference on the Imbalance of Sex Ratio in Korea (한국의 인공임신중절과 남아선호관이 출생시 성비의 불균형에 미치는 영향)

  • Cho, Nam-Hoon;Hong, Moon-Sik;Kim, Il-Hyun
    • Korea journal of population studies
    • /
    • v.17 no.2
    • /
    • pp.77-97
    • /
    • 1994
  • Despite the fact that the national family planning program in korea has accomplished its primary goals of fertility reduction and universal contraceptive use, the induced abortion is still high and there has been an increasing trend in the population sex ratio at birth. It seems that the changes in the imbalance of sex ratio have originated from traditonal boy preference. This indicates that much of the current family planning program can be overhauled, so that the program quality could be better controlled, by preventing the number of unwanted pregnancies and the imbalance of sex ratios. This paper aims, therefore, to examine the determinants of induced abortion through the investigation of pregnancy outcomes and their changes over time and to study the interaction between induced abortion, boy preference and the imbalance of sex ratio in Korea. The abortion rate had increased rapidly until the mid-1980s when there were about the same number of abortions as live births. Thereafter, the abortion rate has been maintained at this high level. By parity it shows a much higher abortion rate for a higher parity at all time. From the first parity, the sex composition of previous children stands out as the most important factor in deciding the pregnancy outcome at all time. The probability of a pregnancy ending in an abortion increases substantially when parents already had a son. The decline of the desired family size and the sustained strong son preference has made the sex of children a more important factor in the determination of the pregnancy outcome. Women's education has had consistently positive effects on the probability of a pregnancy ending in an abortion, but the effect shows a steady decline over time. The premarital pregnancy and urban residence also increase the abortion probability. This study suggests that the main concerns of the family planning program should be to strengthen the social support policies so as to weaken the son preference value leading to a balanced sex ratio and prevention of induced abortions.

  • PDF