• 제목/요약/키워드: Current generator

검색결과 1,278건 처리시간 0.028초

Numerical Calculations and Analyses in Diagonal Type Magnetohydrodynamic Generator

  • Le, Chi Kien
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1365-1370
    • /
    • 2013
  • This paper examines the effects of magnetic induction attenuation on current distribution in the exit regions of the Faraday-type, non-equilibrium plasma Magnetohydrodynamic (MHD) generator by numerical calculation using cesium-seeded helium. Calculations show that reasonable magnetic induction attenuation creates a very uniform current distribution near the exit region of generator channel. Furthermore, it was determined that the current distribution in the middle part of generator is negligible, and the output electrodes can be used without large ballast resistors. In addition, the inside resistance of the exit region and the current concentration at the exit electrode edges, both decrease with the attenuation of magnetic flux density. The author illustrates that the exit electrodes of the diagonal Faraday-type, non-equilibrium plasma MHD generator should be arranged in the attenuation region of the magnetic induction, in order to improve the electrical parameters of the generator.

Influence of Different Frequency Harmonic Generated by Rectifier on High-speed Permanent Magnet Generator

  • Qiu, Hongbo;Wei, Yanqi;Yang, Cunxiang;Fan, Xiaobin
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.1956-1964
    • /
    • 2018
  • Since the stator winding of High-Speed Permanent Magnet Generator (HSPMG) has few winding turns and low inductance value, it is more prone to be influenced by harmonic current. Moreover, the operation efficiency and the torque stability of HSPMG will be greatly influenced by harmonic current. Taking a 117 kW, 60 000 rpm HSPMG as an example, in order to analyze the effects of harmonic current on HSPMG in this paper, the 2-D finite element electromagnetic field model of the generator was established and the correctness of the model was verified by testing the generator prototype. Based on the model, the losses and torque of the generator under different frequency harmonic current were studied. The change rules of the losses and torque were found out. Based on the analysis of the influence of the harmonic phase angle on torque ripple, it is found that the torque ripple could be weakened through changing the harmonic phase angle. Through the analysis of eddy current density in rotor, the change mechanism of the rotor eddy current loss was revealed. These conclusions can contribute to reduce harmonic loss, prevent demagnetization fault and optimize torque ripple of HSPMG used in distributed power supply system.

플럭스 펌프 적용을 위한 대용량 초전도 풍력발전기 파라미터 튜닝 (Parameter tuning of a large-scale superconducting wind power generator for applying a flux pump)

  • 성해진;고병수;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1106-1107
    • /
    • 2015
  • A flux pump (FP) can inject the DC current into high temperature superconducting (HTS) field coils of a HTS rotating machine without slip ring and current lead. However, it has limits to improve the value of DC current, and has time constants of DC current according to inductances of the HTS field coils. When a large-scale HTS generator with the FP is designed, a proper point about the inductance, field current, and time constant is demanded to decide parameters of the generator. In this paper, a parameter tuning skill of a large-scale superconducting wind power generator for applying a FP has been proposed. The design of the FP has been fixed, and 12 MW HTS generators have been variously designed by adjusting parameters related with the inductance of the HTS field coil. The induced current values have been calculated based on the FP design. The time constants of the induced currents depending on the DC current values and inductances of the generator have been represented. The results of the parameter tuning of the HTS generator have been discussed in detail.

  • PDF

전류제어형 PWM컨버터를 이용한 동기발전기용 여자시스템에 관한연구 (A Study on Excitation System for Synchronous Generator using Current Mode Controlled PWM Converter)

  • 장수진;류동균;서민성;김준호;원충연;배기훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.151-156
    • /
    • 2002
  • The output voltage of Synchronous Generator is regulated constantly by field current control in excitation system. A synchronous generator is equipped with an automatic voltage regulator(AVR), which is responsible for keeping the constant output voltage under normal operating conditions about various levels. High frequency PWM converter (Current Mode Control Buck converter) type excitation system for synchronous generator is able to sustain output voltage level properly when the fault condition happened. This paper deals with the design and evaluation of the excitation system controller for a synchronous generator to improve the steady state and transient stability. The simulation and experimental results show that the proposed excitation system is improve the respons time by the AVR(automatic voltage regulator) of 50kW synchronous generator that is applied the current mode control excitation system.

  • PDF

OTA를 이용한 전류-제어 톱니파 발생기 (Current-controllable saw-tooth waveform generator using OTA's)

  • 임동빈;정원섭;송재훈;김희준
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(5)
    • /
    • pp.177-180
    • /
    • 2001
  • A saw-tooth waveform generator with current-controllable frequency is described. The generator utilizes operational transconductance amplifiers as switching element. It features simple and wide sweep capability. The circuit built with commercially avaliable components exhibits good linearity of current to frequency and relatively low temperature sensitivity.

  • PDF

Influence Analysis of Power Grid Harmonics on Synchronous Hydro Generators

  • Qiu, Hongbo;Fan, Xiaobin;Feng, Jianqin;Yang, Cunxiang
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1577-1584
    • /
    • 2018
  • The content of harmonic current increases with an increase in the number of power electronic devices in power grid. When a generator is directly connected to the power grid through a step-up transformer, the influence of the harmonic currents on the generator is inevitable. To study the influences of harmonics on generators, a 24-MW bulb tubular turbine generator is taken as an example in this paper. A 2-D transient electromagnetic field model is established. Through a comparative analysis of the data of experiments and simulations, the correctness of the model is verified. The values of the air gap magnetic density, torque and losses of the generator under various conditions are calculated using the finite element method. Taking the rated condition as a reference, the influence of the harmonic currents on the magnetic flux density is analyzed. It is confirmed that the time harmonic is a key factor affecting the generator performance. At the same time, the effects of harmonic currents on the torque ripple, average torque and eddy current loss of the generator are studied, and the mechanism of the variation of the eddy current loss is also discussed.

울돌목 조류발전소 설치용 1MW 발전설비 시제품 제어특성 (Control characteristics of the prototype power trains of 1MW Uldolmok tidal current plant)

  • 박정우;이기욱;김동욱;이광수;박진순
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.644-647
    • /
    • 2007
  • We have developed electrical power train for 1MW tidal current plant which is composed of both 500kW tidal current plant with doubly-fed induction generator and 500kW tidal current plant with synchronous generator. To check performances of the protype, 2MW dynamometer is used to simulate a helical turbine, and then protype generator and converter are coupled with the dynamometer separately. From the suggested experimental results it is reconfirmed that two kinds of the power train to be installed at the Uldolmok located at southwestern shore in Korea are able to operate under all kinds of the condition about speed and power.

  • PDF

모델 기반의 풍력발전용 유도발전기의 최소 손실 제어 (Model-Based Loss Minimization Control for Induction Generators - in Wind Power Generation Systems)

  • 아보칼릴 아메드;이동춘
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권7호
    • /
    • pp.380-388
    • /
    • 2006
  • In this paper, a novel control algorithm to minimize the power loss of the induction generator for wind power generation system is presented. The proposed method is based on the flux level reduction, where the flux level is computed from the machine model for the optimum d-axis current of the generator. For the vector-controlled induction generator, the d-axis current controls the excitation level in order to minimize the generator loss while the q-axis current controls the generator torque, by which the speed of the induction generator is controlled according to the variation of the wind speed in order to produce the maximum output power. Wind turbine simulator has been implemented in laboratory to validate the theoretical development. The experimental results show that the loss minimization process is more effective at low wind speed and that the percent of power loss saving can approach to 25%. Experimental results are shown to verify the validity of the proposed scheme.

EL-CID를 이용한 발전기 고정자 철심의 건전성 평가 (Healthy Assessment of Generator Stator Cores using EL-CID (ELectromagnetic Core Imperfection Detector))

  • 김병래;김희동
    • 전기학회논문지
    • /
    • 제58권2호
    • /
    • pp.356-362
    • /
    • 2009
  • The ELectromagnetic Core Imperfection Detector (EL-CID) test was performed on a small generator in the laboratory and a gas turbine generator in the field to assess the fault condition of generator stator core. Artificial defects with six different sizes were introduced in the small generator. The scan results on six defects show a very large increase in the magnitude of fault current compared to that obtained with a healthy core. After the stator core heats up, a thermal imaging camera was used to detect hot spot on the inner surface of the core for comparison. Several faults were found during inspection of the gas turbine generator with the EL-CID. It has been shown that the existence of a fault can be determined by monitoring the magnitude of fault current.

Loss Minimization of DFIG for Wind Power Generation

  • Abo-Khalil, Ahmed G.;Park, Hong-Geuk;Lee, Dong-Choon;Lee, Se-Hyun
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.315-317
    • /
    • 2007
  • This paper proposes a loss minimization algorithm for doubly-fed induction generator (DFIG) by controlling the stator reactive power. The proposed strategy directly controls the rotor current to achieve the operating point of minimum generator loss and maximum power point tracking. The maximum power is obtained by tracking the q-axis rotor current with generator speed variation and the minimum generator loss is achieved by controlling the d-axis rotor current. Experimental results are shown to verify the validity of the proposed scheme.

  • PDF