• Title/Summary/Keyword: Current conditioning

Search Result 360, Processing Time 0.028 seconds

Development of a TFM load calculation program based on thermal response factor (열응답계수를 이용한 TFM 부하계산법의 제안)

  • 최우영;고철균;이재헌;류해성
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.5
    • /
    • pp.684-691
    • /
    • 1999
  • A load calculation program based on TFM(Transfer function method) has been proposed in this study. The validity of the current method has been verified by comparing heat gain calculation by TRF(Thermal response factor) with that by CTF(Conduction transfer function) adopted in ASHRAE. In addition, it seems that the CTF coefficients given in ASHRAE tables have somewhat ambiguity The load calculation program developed in the current study has been employed to calculate cooling load from the exterior walls and roof of example 6 in the ASHRAE. The results are found in good agreement.

  • PDF

Utilizing Advanced Pad Conditioning and Pad Motion in WCMP

  • Kim, Sang-Yong;Chung, Hun-Sang;Park, Min-Woo;Kim, Chang-Il;Chang, Eui-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.171-175
    • /
    • 2001
  • Chemical mechanical polishing(CMP) process has been widely used to planarize dielectrics and metal, which can apply to employed in integrated circuits for sub-micron technology. Despite the increased use of CMP process, it is difficult to accomplish the global planarization of free-defects in inter level dielectrics and metal. Especially, defects like (micro-scratch) lead to severe circuit failure, and affects yield. Current conditioning method - bladder type, orbital pad motion - usually provides unsuitable pad profile during ex-situ conditioning near the end of pad life. Since much of the pad wear occurs by the mechanism of bladder tripe conditioning and its orbital motion without rotation, we need to implement new ex-situ conditioner which can prevent abnormal regional force on pad caused by bladder-type and also need to rotate the pad during conditioning. Another important study of ADPC is related to the orbital scratch of which source is assumed as diamond grit dropped from the strip during ex-situ conditioning. Scratch from diamond grit damaged wafer severely so usual1y scraped. Figure 1 shows the typical shape of scratch damaged from diamond. We suspected that intensive forces to the edge area of bladder type stripper accelerated the drop of Diamond grit during conditioning, so new designed Flat stripper was introduced.

  • PDF

A Study on the Status and Improvement of Technical Standard on Building Mechanical System Engineering (건축기계 설비분야 기술기준 현황과 개선방안 연구)

  • Park, Jong-Il;Park, Yool;Im, Byeong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.4
    • /
    • pp.241-247
    • /
    • 2010
  • This study aims to investigate and improve the present state of technical standard on building mechanical system in Korea. At this point be tormented the energy depletions are big problem on the rise. Building mechanical system is configured air conditioning, sanitation, urban equipment. In the design of equipment, installation, maintenance, applies to all devices in the field of industrial equipment and general engineering equipment field are within bounds to say that all of the equipment field. However, domestic technology level is still fly short of international standards in architecture, we spent much energy. Because of this, find the current situation and identify the problems look up ways to improve them.

The Development & Performance Test of 10[kW] Power Conditioning System for Microgrid (마이크로그리드용 10[kW] PCS 개발 및 성능시험)

  • Lee, Hak-Ju;Chae, Woo-Kyu;Park, Jung-Sung;Kim, Ju-Yong;Kim, Chan-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.55-62
    • /
    • 2011
  • PCS(Power Conditioning System) is the necessary component in Microgrid, composed of multiple distributed generators and energy storage system. In this paper, the functions of PCS are defined and 10[kW] PCS for PV and BESS are developed. To apply PCSs to Microgrid, this paper presents a 3-phase inverter with the decoupling current controller, voltage controller and DPLL control system. PCSs were applied to 120[kW] pilot plant and its performance tests were carried out. Test results of PCS at each operation mode show stable in Microgrid.

High-Efficiency Power Conditioning System for Grid-Connected Photovoltaic Modules

  • Choi, Woo-Young;Choi, Jae-Yeon
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.561-567
    • /
    • 2011
  • This paper presents a high-efficiency power conditioning system (PCS) for grid-connected photovoltaic (PV) modules. The proposed PCS consists of a step-up DC-DC converter and a single-phase DC-AC inverter for the grid-connected PV modules. A soft-switching step-up DC-DC converter is proposed to generate a high DC-link voltage from the low PV module voltage with a high-efficiency. A DC-link voltage controller is presented for constant DC-link voltage regulation. A half-bridge inverter is used for the single-phase DC-AC inverter for grid connection. A grid current controller is suggested to supply PV electrical power to the power grid with a unity power factor. Experimental results are obtained from a 180 W grid-connected PV module system using the proposed PCS. The proposed PCS achieves a high power efficiency of 93.0 % with an unity power factor for a 60 Hz / 120 Vrms AC power grid.

Evaporator Superheat Control of a Multi-type Air-conditioning/Refrigeration System (멀티형 공조/냉동시스템의 증발기 과열도 제어)

  • Kim, Tae-Sub;Hong, Keum-Shik;Sohn, Hyun-Chul
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.712-717
    • /
    • 2001
  • This paper investigates the control problem of evaporator superheat, i.e., the difference between the temperature of the refrigerant at the entrance region of an evaporator and that at the exit region, for multi-type air-conditioning/refrigeration systems. Mathematical equations describing the characteristics of compressor, condenser, evaporator, and electronic expansion valve are first derived. Then, the transfer functions from the current input of the electronic expansion valve to wall temperatures of evaporator tube at two-phase region and superheated region, respectively, are derived. The stability and performance of the closed loop system with a PI controller are analyzed by Nyquist stability criterion. Simulation results are provided.

  • PDF

Modular Line-connected Photovoltaic PCS (모듈형 계통연계 태양광 PCS)

  • Seo, Hyun-Woo;Kwon, Jung-Min;Kim, Eung-Ho;Kwon, Bong-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.119-127
    • /
    • 2008
  • In this paper, the modular line-connected photovoltaic PCS (photovoltaic power conditioning system) is proposed. A step-up DC-DC converter using a active-clamp circuit and a dual series-resonant rectifier is proposed to achieve a high efficiency and a high input-output voltage ratio efficiently. An IncCond (incremental conductance) MPPT (maximum power point tracking) algorithm that improves MPPT characteristic is used. The PV module current is estimated without using a DC current sensor. By control a inverter using a linearized output current controller, a unity power factor is achieved. All algorithms and controllers are implemented on a single-chip microcontroller and the superiority of the proposed DC-DC converter and controllers is proved by experiments.

Heat and Mass Transfer Characteristics of a Falling Film Ammonia Absorber with Respect to the Vapor Flow Direction (유하액막식 암모니아 흡수기에서 증기 유동방향에 따른 열 및 물질전달 특성)

  • 권경민;정시영;김병주;정은수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.16-25
    • /
    • 2004
  • The flow and heat/mass transfer in the falling-film of a heat exchanger can be influenced by the motion of the surrounding refrigerant vapor. In this study, the effect of the vapor flow direction on the absorption heat transfer has been investigated for a falling-film helical coil which is frequently used as the absorber of ammonia/water absorption refrigerators. The experiments were carried out for different solution concentration. The heat and mass transfer performance was measured for both parallel and counter-current flow. The effect of vapor flow on the heat and mass transfer is found to be increased with decreasing solution concentration. In the experiments with low solution concentration, whose vapor specific volume is great, the counter-current flow of vapor resulted in uneven distribution of falling-film and reduced the heat transfer performance of the absorber. The direction of the vapor flow hardly affected the thermal performance as the solution concentration became stronger since the specific volume of the ammonia/water vapor was much smaller than that of the water vapor.

Modeling and Analysis of Leakage Currents in PWM-VSI-Fed PMSM Drives for Air-Conditioners with High Accuracy and within a Wide Frequency Range

  • Sun, Kai;Lu, Yangjun;Xing, Yan;Huang, Lipei
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.970-981
    • /
    • 2016
  • Leakage currents occur in pulse-width-modulated voltage source inverter (PWM-VSI)-fed permanent magnet synchronous motor (PMSM) drives for air-conditioners, which seriously affect system safety and operation performance. High accuracy modeling and prediction of leakage currents are key issues for the design and implementation of air-conditioning products. In this study, the generation mechanism of leakage currents is discussed. A systematic modeling approach of leakage currents is proposed, including the modeling of leakage current sources and leakage current paths. By using the proposed approach, the complete model of leakage currents in PWM-VSI-fed PMSM drives for air-conditioners has been developed based on the extraction of all parameters. A comparison between the simulated leakage currents based on the developed model and measured leakage currents in the outdoor unit of an air-conditioning product is conducted. The comparison verifies the effectiveness of the proposed modeling approach, and the developed model exhibits high accuracy within a wide frequency range.

The Experimental Study on The Counter-Current Flow Limit in The Flow Path with a Porous Plate (다공판 유로 내의 유동한계(CCFL)에 대한 실험적 연구)

  • Yang, Seung-Woo;Lee, Jin-Ki;Kwon, Jeong-Tae;Kim, Sang-Nyung;Kang, Yong-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.2
    • /
    • pp.156-161
    • /
    • 2007
  • A set of experiments of counter-current flow limit (CCFL) was performed to improve the drawbacks of Wallis' correlation which neglected the effects of channel size, channel length, injection method and the boundary conditions at the inlet of liquid and gas phase. In this study, CCFL was observed by changing the shape of porous plate using air and water. The results show that as the size of porous increases, CCFL with a round shape of the porous plate start to disappear, In this study, the CCFL correlation was calculated and the corresponding CCFL map was developed based on the experimental results.