• Title/Summary/Keyword: Current Reference

Search Result 2,338, Processing Time 0.028 seconds

Harmonic Current Reference Generation of Single-Phase Active Filter for the Converter-Fed Locomotives (고속전철용 단상능동필터의 기준고조파전류 발생 방법)

  • Sung, Gi-Seok;Song, Joong-Ho;Choi, Ik;Choi, Ju-Yeop;Kim, Gwang-Bae;Kim, Kwon-Ho;Lim, Myo-Taek
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.338-341
    • /
    • 1999
  • PWM controlled line-side converters of modern ac traction locomotives inject harmonic currents into the feeding overhead line. This causes problem of electromagnetic interference. Passive and Active filters are usually provided for a reduction of the line harmonics. Active filters are more reasonable than passive filters in terms of weight and space of the filters. Successful control of active filters requires an accurate harmonic current reference. A technique to generate the harmonic current reference is proposed in this paper. The analysis is performed in frequency domain and its effectiveness is verified by simulation.

  • PDF

A CMOS Charge Pump Circuit with Short Turn-on Time for Low-spur PLL Synthesizers

  • Sohn, Jihoon;Shin, Hyunchol
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.6
    • /
    • pp.873-879
    • /
    • 2016
  • A charge pump circuit with very short turn-on time is presented for minimizing reference spurs in CMOS PLL frequency synthesizers. In the source switching charge pump circuit, applying proper voltages to the source nodes of the current source FETs can significantly reduce the unwanted glitch at the output current while not degrading the rising time, thus resulting in low spur at the synthesizer output spectrum. A 1.1-1.6 GHz PLL synthesizer employing the proposed charge pump circuit is fabricated in 65 nm CMOS. The current consumption of the charge pump is $490{\mu}A$ from 1 V supply. Compared to the conventional charge pump, it is shown that the reference spur is improved by dB through minimizing the turn-on time. Theoretical analysis is described to show that the measured results agree well with the theory.

Reference compensating current estimation for active power filters in DC traction system (DC 급전 전철시스템에서의 능동전력필터 기준보상전류 추정)

  • Bae, Chang-Han
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.224-226
    • /
    • 2004
  • Digital Kalman filter is presented as a powerful approach to obtain the reference estimation of the control current for shunt active power filter. This algorithm provides the best estimate of the fundamental and harmonic frequency components from the sampled values of the line current or voltage. By adopting of the digital Kalman filtering algorithm, the structure of the control algorithm eliminates the need of a Phase locked loop(PLL) for the synchronization of the reference signal used in the compensation and it not sensitive to the distortion of the line voltage. The effectiveness of the algorithm is confirmed by the computer simulations.

  • PDF

A study of the reference compensating current estimation for active power filter (능동전력필터의 기준보상전류 추정에 관한 연구)

  • Bae Chang-han;Han Mun-seub;Kim Yong-ki;Bang Hyo-jin
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1480-1485
    • /
    • 2004
  • In this paper, a real-time digital kalman filtering algorithm is used to obtain the reference estimation of the control current for shunt active power filter. This algorithm provides the best estimate of the fundamental and harmonic frequency components from the sampled values of the line current or voltage waveform. By adopting of the digital Kalman filtering algorithm, the structure of the control algorithm eliminates the need of a Phase locked loop(PLL) for the synchronization of the reference signal used in the compensation and it not sensitive to the distortion of the line voltage. The effectiveness of the algorithm is confirmed by the computer simulations.

  • PDF

Dual-mode CMOS Current Reference for Low-Voltage Low-Power (저전압 저전력 듀얼 모드 CMOS 전류원)

  • Lee, Geun-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.4
    • /
    • pp.917-922
    • /
    • 2010
  • In this paper, a new temperature-insensitive CMOS dual-mode current reference for low-voltage low-power mixed-mode circuits is proposed. The temperature independent reference current is generated by summing a proportional to absolute temperature(PTAT) current and a complementary to absolute temperature(CTAT) current. The temperature insensitivity was achieved by the mobility and the other which is inversely proportional to mobility. As the results, the temperature dependency of output currents was measured to be $0.38{\mu}A/^{\circ}C$ and $0.39{\mu}A/^{\circ}C$, respectively. And also, the power dissipation is 0.84mW on 2V voltage supply. These results are verified by the $0.18{\mu}m$ n-well CMOS parameter.

Effect of Initial (Reference) Welding Current for Adaptive Control and It's Optimization to Secure Proper Weld Properties in Resistance Spot Welding

  • Ashadudzzaman, Md.;Choi, Il-Dong;Kim, Jae-Won;Nam, Dae-Geun;Park, Yeong-Do
    • Journal of Welding and Joining
    • /
    • v.33 no.6
    • /
    • pp.13-20
    • /
    • 2015
  • Many automotive companies are endeavoring to improve the quality of resistance spot welding by updating body-in-white (BIW) production line with adaptive control spot welding system to compensate the process disturbances such as gap, electrode wear, oxidized surfaces, poor fit up and adhesive etc. Most of the commercial adaptive weld controllers require proper "Initial Welding Schedule" or "Reference weld" to achieve compensation in welding parameters during real time welding. In this study, the compensation of a commercial adaptive weld controller had been observed and analyzed thoroughly for various process disturbances to find optimal initial welding schedule. It was observed that 90 percent of the expulsion current in constant current control as reference welding schedule conferred the maximum button diameter in adaptive control welding. Finally, effects of each disturbance in combined field disturbances system with adaptive control had also been confirmed with the design of experiment (DOE) by minitab(R)16 for combined disturbances situation and suitability of optimum initial weld current had also established with real body part validation test.

Design Methodology of the CMOS Current Reference for a High-Speed DRAM Clocking Circuit (초고속 DRAM의 클록발생 회로를 위한 CMOS 전류원의 설계기법)

  • Kim, Dae-Jeong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.2
    • /
    • pp.60-68
    • /
    • 2000
  • This paper describes a design methodology for the CMOS current source which can be implemented in standard memory process. The proposed techniques provide a good characteristic against the power-supply variation by utilizing a self-bias circuit and the reduction of the first-order component of the temperature variation through the new temperature compensation technique and include a new current-sensing start-up circuit enabling a robust operation against the voltage noise generated during the operation of the chip. In addition to the circuit-design technology, techniques where the proposed CMOS current-reference circuit can be applied to the clocking circuits of a very high-speed DRAM are presented. The feasibility of the suggested design methodology for the CMOS current reference is demonstrated by both the analytical method and the circuit simulation.

  • PDF

Air-pressure Control of Diaphragm using Variable Frequency Current Control (가변 주파수 전류 제어에 의한 다이어프램의 압력제어)

  • Lim, Geun-Min;Lee, Dong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.258-265
    • /
    • 2011
  • This paper presents a variable frequency current control scheme for the air-pressure control of diaphragm. Differ from the conventional air-pressure control of diaphragm, the proposed method uses a single-phase inverter to control the phase current and frequency. The phase current is adjusted to keep the reference air-pressure of the diaphragm. And the current frequency is changed to reduce the mechanical vibration. In order to smooth change of the operation with a constant air-pressure, the frequency is changed according to the voltage reference from the current controller. When the phase current is satisfied to the constant air-pressure, the current frequency is increased to reduce the vibration of the diaphragm. When the reference voltage to keep the phase current is over than the set value, the current frequency is decreased to keep the air-pressure. The proposed control scheme is verified by the experimental test of a commercial diaphragm.

Cooperative System for Virtual Reference Shelves of the University Libraries (대학도서관 가상참고서가의 협동구축)

  • Park Joon-Shik
    • Journal of Korean Library and Information Science Society
    • /
    • v.36 no.4
    • /
    • pp.5-25
    • /
    • 2005
  • This study is designed to research principles for establishing cooperatively virtual reference shelves of university libraries. To achieve the goal, this study establishes theoretical foundations for virtual reference shelves. Also, we discuss why the virtual reference shelves are necessary via cultural subject of libraries. Second, this study investigates current circumstances of virtual reference shelves' usages. This Investigation is conducted in terms of nine evaluation indexes. The results are used to justify the cooperative establishment for virtual reference shelves. Last, this study discusses actual methods and procedures for establishing cooperatively virtual reference shelves, associating with roles of related institutions.

  • PDF

The Perceived Benefits of Electronic/digital Reference Services in Nigerian University Libraries: a survey

  • Uzoigwe, Comfort U.;Eze, Jacintha U.
    • International Journal of Knowledge Content Development & Technology
    • /
    • v.8 no.2
    • /
    • pp.49-65
    • /
    • 2018
  • Are the benefits derived from ICT based reference and information service worth the financial and other commitments devoted to it? In an attempt to answer this, this study delved into finding out the perceived benefits; the rational for ICT based reference services in Nigerian university libraries. The main objectives were to find out the purposes for using ICT facilities in reference services delivery and the perceived benefits derived from using ICT resources in reference and information services. Being a survey, questionnaire was used to collect data from the librarians of twelve (12) universities; two (2) each sampled from the six geopolitical zones of Nigeria. Data was analyzed using frequencies, mean scores and standard deviations. ANOVA statistical analysis was used to test the hypothesis of no significance difference in the benefits derived from ICT based reference services using p-value of 0.05 to calculate the level of significance. Findings showed that librarians and library users made use of ICT facilities for different reference purposes especially to obtain information they need using the internet. Other reference needs for which patrons used the ICT facilities included: - access to current e-books and e - journals, user education and access to global information in other libraries. Provision of current awareness services (CAS) and selective dissemination of information services (SDI), on-line searching using workstations in the library, provision of on-line public access catalogue (OPAC) services, keeping statistics of users of the reference section and compilation of bibliographies. Further findings showed that the librarians and library users derive a lot of benefits from their use of ICT facilities in reference services. The results showed that easy retrieval and dissemination of information to patrons were ranked highest by the librarians amongst others.