• Title/Summary/Keyword: Current Path Distribution

Search Result 91, Processing Time 0.023 seconds

A Study on Improving the Current Density Distribution of the Cathode by the Bipolar Phenomenon of the Auxiliary Anode through the Hull Cell Experiment (헐셀을 통한 보조 양극의 바이폴라 현상에 의한 음극의 전류밀도 분포 개선 영향성 연구)

  • Young-Seo Kim;Yeon-Soo Jeong;Han-Kyun Shin;Jung Han Kim;Hyo-Jong Lee
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.1
    • /
    • pp.71-78
    • /
    • 2023
  • The possibility of improving plating thickness distribution was investigated through quantitative consideration of bipolar electrodes without external power applied. By having the cathode tilted with respect to the anode, the potential distribution in the electrolyte solution adjacent to the cathode is different due to the difference in iR drop due to the path difference to the anode in each region of the cathode. The purpose of this study is to observe the bipolar characteristics in the case of an auxiliary anode for the non-uniform potential distribution of such a Hull cell. In particular, in order to evaluate the possibility of improving the non-uniform thickness distribution of the cathode by utilizing these bipolar characteristics, it was verified through experiments and simulations, and the electric potential and current density distribution around the bipolar electrode were analyzed. The electroplating in a Hull cell was performed for 75 min at a current density of 10 mA/cm2, and the average thickness is about 16 ㎛. The standard deviation of the thickness was 10 ㎛ in the normal Hull cell without using the auxiliary anode, whereas it was 3.5 ㎛ in the case of using the auxiliary cathode. Simulation calculations also showed 8.9 ㎛ and 3.3 ㎛ for each condition, and it was found that the consistency between the experimental and simulation results was relatively high, and the thickness distribution could be improved through using the auxiliary anode by the bipolar phenomenon.

An Empircal Model of Effective Path Length for Rain Attenuation Prediction (강우감쇠 유효경로 길이 예측을 위한 경험 모델)

  • 이주환;최용석;박동철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.5
    • /
    • pp.813-821
    • /
    • 2000
  • The engineering of satellite communication systems at frequencies above 10GHz requires a method for estimating rain-caused outage probabilities on the earth-satellite path. A procedure for predicting a rain attenuation distribution from a point rainfall rate distribution is, therefore, needed. In order to predict rain attenuation on the satellite link, several prediction models such as ITU-R, Global, SAM, DAH model, have been developed and used at a particular propagation condition, they may not be appropriate to a propagation condition in Korean territory. In this paper, a new rain attenuation prediction method appropriate to a propagation condition in Korea is introduced. Based on the results from ETRI measurements, a new method has been derived for an empirical approach with an identification on the horizontal correction factor as in current ITU-R method, and the vertical correction factor has been suggested with decreasing power law as a function of rainfall rate. This proposed model uses the entire rainfall rate distribution as input to the model, while the ITU-R and DAH model approaches only use a single 0.01% annual rainfall rate and assume that the attenuation at other probability levels can be determined from that single point distribution. This new model was compared with several world-wide prediction models. Based on the analysis, we can easily know the importance of the model choice to predict rain attenuation for a particular location in the radio communication system design.

  • PDF

Study on Time and Spatial Distribution of Typhoon Storms (태풍성(颱風性) 강우(降雨)의 시공간(時空間) 분포(分布)에 관(關)한 연구(硏究))

  • Yoon, Kyung-Duck;Suh, Seung-Duk
    • Current Research on Agriculture and Life Sciences
    • /
    • v.15
    • /
    • pp.53-67
    • /
    • 1997
  • The objective of this study is to provide with the hydro-meteological and probabilistic characteristics of the storms of typhoons that have been passed through the Korean peninsula during the last twenty-three years since 1961. The paths and intensities of the typhoons were analyzed. Fifty weather stations were selected and the rainfall data during typhoon periods were collected. Rainfall data were analyzed for the patterns and probabilistic distributions. The results were presented to describe the areal distributions of probabilistic characteristics. The results obtained from this study can be summarized as follows: 1. The most frequent typhoon path that has passed through the Korean peninsula was type E, followed by types CWE, W, WE, and S. The most frequent typhoon intensity was type B, followed by A, super A, and e types, respectively. 2. The third quartile typhoon rainfall patterns appear most frequently followed by the second, first, and last quartiles, respectively, in Seoul, Pusan, Taegu, Kwangju and Taejon. The single typhoon rainfalls with long rainfall durations tended to show delayed type rainfall patterns predominantly compared to the single rainfalls with short rainfall durations. 3. The most frequent probabilistic distribution of typhoon rainfall event is Pearson type-III, followed by Two-parameter lognormal distribution, and Type-I extremal distribution. 4. The most frequent probability distribution model of seashore location was Pearson type-III distribution. The most frequent probability distribution model of inland location was two parameter lognormal distribution.

  • PDF

The Inflow Path of the East Sea Intermediate Water into the Ulleung Basin in July 2005

  • Shin, Chang-Woong
    • Ocean and Polar Research
    • /
    • v.28 no.2
    • /
    • pp.153-161
    • /
    • 2006
  • To investigate inflow path of the East Sea Intermediate Water (ESIW) into the Ulleung Basin, hydrographic data surveyed in July 2005 were analyzed. The ESIW was characterized by the Salinity Minimum Layer (SML) within a depth range of 100 to 360 meters. Averaged potential temperature and salinity of the SML were $1.835^{\circ}C$ and 34.049 psu, respectively. Mean potential density $({\sigma}_{\theta})$ of the SML was 27.221 with a standard deviation of 0.0393. On isopycnal surfaces of 27.14 and 27.18 $({\sigma}_{\theta})$ which correspond to upper layers of the ESIW, the coastal low salinity water was separated from the offshore low salinity water by the relatively warm and saline water which might be affected by the Tsushima Warm Current Water. Relatively cold and fresh water, however, intruded into the Ulleung Basin from the region of Korean coast on isopycnal surfaces of 27.22 and 27.26 which was lower layer of the ESIW. The salinity distribution in the isopycnal layer of $27.14{\sim}27.26$ with acceleration potential on 27.22 up surface also showed clearly that the low salinity water flowed from the coastal area and intruded into the Ulleung Basin. This implies that the ESIW flows ken the north to the south along the east coasts of Korea and spreads into the Ulleung Basin in summer.

Comparison of the fluid simulation with experimental data of excited Xe species density in PDP cell

  • Yang, Sung-Soo;Ko, Sang-Woo;Kim, Hyun-Chul;Mukherjee, Sudeshna;Lee, Jae-Koo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.739-742
    • /
    • 2003
  • We have compared 2-D and 3-D fluid simulation results of alternating current plasma display panel (AC-PDP) cell with experimentally measured two kinds of excited Xe species $Xe^{\ast}(^{3}P_{1})$ and $Xe^{\ast}(^{3}P_{2})$ characteristics. Although direct experimental access and diagnostics of the discharge in a PDP cell is problematic due to the small cell size, some of experimental technologies have made it possible to diagnose the behavior of excited Xe species [1, 2]. The simulation shows the similar characteristics to the experimental results in the excited Xe species density distribution and the number of excited Xe atoms in anode and cathode region. In certain cases, we obtained the arch-shaped discharge path between two sustain electrodes due to the additional pulse applied to address electrode analogous to experiment. This long path discharge induced higher luminous and discharge efficiency compared to the standard case.

  • PDF

AC transport current loss analysis for anti-parallel current flow in face-to-face stacks of superconducting tapes

  • Yoo, Jaeun;Han, Young-Hee;Kim, Hey-Rim;Park, Byung-Jun;Yang, Seong-Eun;Kim, Heesun;Yu, Seung-Duck;Park, Kijun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.2
    • /
    • pp.42-46
    • /
    • 2014
  • In this study we investigated ac transport current losses in the face to face stack for the anti-parallel current flow, and compared the electromagnetic properties with those of the single SC tape as well as those of the same stack for the parallel current path. The gap between the SC tapes in the stack varied in order to verify the electromagnetic influence of the neighbors when current flows in opposite direction, and the model was implemented in the finite element method program by the commercial software, COMSOL Multiphysics 4.2a. Conclusively speaking, the loss was remarkably decreased for the anti-parallel current case, which is attributed the magnetic flux compensation between the SC layers due to the opposite direction of the current flows. As the gap between SC tapes was increased, the loss mitigation became less effective. Besides, the current density distribution is very flat cross the sample width for the narrower gap case, which is believed to be benefit for the power electric system. These results are all in good agreement with those predicted theoretically for an infinite bifilar stack.

Domestic Efforts for SFCL Application and Hybrid SFCL (국내 초전도 한류기 요구와 하이브리드 초전도 한류기)

  • Hyun, O.B.;Kim, H.R.;Yim, Y.S.;Sim, J.;Park, K.B.;Oh, I.S.
    • Progress in Superconductivity
    • /
    • v.10 no.1
    • /
    • pp.60-67
    • /
    • 2008
  • We present domestic efforts for superconducting fault current limiter (SFCL) application in the Korea Electric Power Corporation (KEPCO) grid and pending points at issue. KEPCO's decision to upgrade the 154 kV/22.9 kV main transformer from 60 MVA to 100 MVA cast a problem of high fault current in the 22.9 kV distribution lines. The grid planners supported adopting an SFCL to control the fault current. This environment friendly to SFCL application must be highly dependent upon the successful development of SFCL having specifications that domestic utility required. The required conditions are (1) small size of not greater than twice of 22.9 kV gas insulated switch-gear (GIS), (2) sustainability of current limitation without the line breaking by circuit breakers (CB) for maximum 1.5 seconds. Also, optionally, recommended is (3) the reclosing capability. Conventional resistive SFCLs do not meet (1) $\sim$ (3) all together. A hybrid SFCL is an excellent solution to meet the conditions. The hybrid SFCL consists of HTS SFCL components for fault detection and line commutation, a fast switch (FS) to break the primary path, and a limiter. This characteristic structure not only enables excellent current limiting performances and the reclosing capability, but also allows drastic reduction of HTS volume and small size of the cryostat, resulting in economic feasibility and compactness of the equipment. External current limiter also enables long term limitation since it is far less sensitive to heat generation than HTS. Semi-active operation is another advantage of the hybrid structure. We will discuss more pending points at issues such as maintenance-free long term operation, small size to accommodate the in-house substation, passive and active control, back-up plans, diagnosis, and so on.

  • PDF

Implementation of Leakage Monitoring System Using ZigBee (ZigBee를 적용한 누전상태 모니터링시스템 구현)

  • Ju, Jae-han;Na, Seung-kwon
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.1
    • /
    • pp.107-112
    • /
    • 2017
  • In recent years, electric shock accidents due to electric leakage currents of household appliances such as computers, TVs, refrigerators, and LED lights are continuously occurring in homes and industrial buildings. And it is not easy to check the leakage current of each household appliances connected in parallel at the rear end of the module. In addition, the leakage current flowing through the path of the normal current other than the existing current leakage circuit breakers are installed in the distribution box, only the function to cut off the power when the leakage. Therefore, there are various disasters such as electric shock and fire caused by short circuit of household appliances, and the risk of such leakage current is seriously presented. In this paper, we propose a method to implement a leakage monitoring system that can be monitored at all times using Zigbee communication based on IEEE 80215.4, which has advantages in low power and low cost among short range wireless communication systems.

Channel characteristics of multi-path power line using a contactless inductive coupling unit (비접촉식 유도성 결합기를 이용한 다중경로 전력선 채널 특성)

  • Kim, Hyun-Sik;Sohn, Kyung-Rak
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.799-804
    • /
    • 2016
  • Broadband powerline communication (BPLC) uses distribution lines as a medium for achieving effective bidirectional data communication along with electric current flow. As the material characteristics of power lines are not good at the communication channel, the development of power line communication (PLC) systems for internet, voice, and data services requires measurement-based models of the transfer characteristics of the network suitable for performance analysis by simulation. In this paper, an analytic model describing a complex transfer function is presented to obtain the attenuation and path parameters for a multipath power line model. The calculated results demonstrated frequency-selective fading in multipath channels and signal attenuation with frequency, and were in good agreement with the experimental results. Inductive coupling units are used as couplers for coupling the signal to the power line to avoid physical connections to the distribution line. The inductance of the ferrite core, which depends on the frequency, determines the cut-off frequency of the inductive coupler. Coupling loss can be minimized by increasing the number of windings around the coupler. Coupling efficiency was improved by more than 6 dB with three windings compared to the results obtained with one winding.

An Analysis of Structural Relationships among Financial Indicators of Hospitals in Korea: Applying Structural Equation Modeling(SEM) (병원 재무비율 지표들 간의 구조적인 관계 분석)

  • Jung, Min-Soo;Lee, Keon-Hyung;Choi, Man-Kyu
    • Health Policy and Management
    • /
    • v.18 no.2
    • /
    • pp.19-38
    • /
    • 2008
  • Financial ratios are key indicators of an organization's financial and business conditions. Among various financial indicators, profitability, financial structure, financial activity and liquidity ratios are frequently used and analyzed. Using the structural equation modeling(SEM) technique, this study examines the structural causal relationships among key financial indicators. Data for this study are taken from complete financial statements from 142 hospitals that passed the standardization audit undertaken by the Korean Hospital Association from 1998 to 2001 for the purpose of accrediting teaching hospitals. In order to improve comparability, ratio values are standardized using the Blom's normal distribution. The final model of the SEM has four latent constructs: financial activity(total asset turnover, fixed asset turnover), liquidity(current ratio, quick ratio, collection period), financial structure(total debt to equity, long-term debt to equity, fixed assets to fund balance), and profitability(return on assets, normal profit to total assets, operating margin to gross revenue, normal profit to gross revenue). While examining several model fit indices(Chi-square (df) = 178.661 (40), likelihood ratio=4.467, RMR=.11, GFI=.849, RMSEA=.157), the final SEM we employed shows a relatively good fit. After examining the path coefficient of the constructs, the financial structure of the hospital affects the hospital's profitability in a statistically significant way. A hospital which utilizes its liabilities, more specifically fixed liabilities, and makes a stable investment decision for fixed assets was found to have a higher profitability than other hospitals. Then, the standard path coefficients were examined to directly compare the influence of variables. It was found that there were no statistically significant path coefficients among constructs. When it comes to variables, however, statistically significant relationships were found. between. financial activity and. fixed. asset turnover, and between profitability and normal profit to gross revenue. These results show that the observed variables of fixed asset turnover and normal profit to gross revenue can be used as indicators representing financial activity and profitability.