• Title/Summary/Keyword: Current Compensation

Search Result 1,238, Processing Time 0.023 seconds

Development of a Work-Related Injury and Illness Monitoring Geographic Information System using Workers' Compensation Insurance Big Data (산재보험 빅데이터를 활용한 산재 모니터링 지리정보시스템 개발)

  • Yoo, Dong Hee;Chung, Suk Hoon;Lee, Jeong Hwa;Choi, Keun Ho
    • The Journal of Information Systems
    • /
    • v.31 no.2
    • /
    • pp.217-238
    • /
    • 2022
  • Purpose This study aims to develop a work-related injury and illness monitoring geographic information system that analyzes and visualizes the types of work-related injury and illness based on workers' compensation insurance big data. Design/methodology/approach Using the developed system, we explained the process of monitoring the areas of the applied workplace, medical care application, index, and medical care institution. We also showed examples of analyzing the index and medical care institution area. By applying the system, we can intuitively recognize the current status of workers' compensation insurance and confirm the basic information necessary for managing the current status of workers' compensation insurance. Findings We generated more helpful information by combining workers' compensation insurance data and designated medical care institution data. We were able to apply the severity score and the vulnerability index of work-related injury and illness to the system as a demonstration. To efficiently manage workers' compensation insurance, it was necessary to integrate workers' compensation insurance and designated medical care institution data, as well as the data from various sources.

Dead Time Compensation Algorithm for the 3-phase Inverter (3상 인버터에 대한 간단한 데드타임 보상 알고리즘)

  • Kim, Hong Min;Baek, Seung Ho;Ahn, Jin Woo;Lee, Dong Hee
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.71-72
    • /
    • 2011
  • This paper presents a novel and direct dead time compensation method of the 3 phase inverter using space vector pulse width modulation(SVPWM) topology. In the turn on time calculation of the effective voltage, the dead time effect is directly compensated according to the current direction of the midium voltage reference. Since the turn on time of the effective voltage vector is affected by the dead time, the loss time is compensated to turn on time of the effective voltage vector. And the dead time is added to the calculated voltage vector switching times according to the current direction. For the more effective compensation, the direction of the midium phase current is considered by the practical direction and voltage drops in the power devices. The proposed method can compensate the dead time which is considered feedback error or direction of middle phase current without coordinate transform in added controller. The proposed dead time compensation scheme is verified by the computer simulation and experiments of 3 phase R L load.

  • PDF

A 32nm and 0.9V CMOS Phase-Locked Loop with Leakage Current and Power Supply Noise Compensation

  • Kim, Kyung-Ki;Kim, Yong-Bin
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.7 no.1
    • /
    • pp.11-19
    • /
    • 2007
  • This paper presents two novel compensation circuits for leakage current and power supply noise (PSN) in phase locked loop (PLL) using a nanometer CMOS technology. The leakage compensation circuit reduces the leakage current of the charge pump circuit which becomes more serious problem due to the thin gate oxide and small threshold voltage in nanometer CMOS technology and the PSN compensation circuit decreases the effect of power supply variation on the output frequency of VCO. The PLL design is based on a 32nm predictive CMOS technology and uses a 0.9V power supply voltage. The simulation results show that the proposed PLL achieves a 88% jitter reduction at 440MHz output frequency compared to the PLL without leakage compensator and its output frequency drift is little to 20% power supply voltage variations. The PLL has an output frequency range of $40M{\sim}725MHz$ with a multiplication range of 11023, and the RMS and peak-to-peak jitter are 5ps and 42.7ps, respectively.

A Study on the Legal System of Compensation for Fishery Loss caused by Public Works (우리나라 어업손실 보상제도에 대한 정선방안 연구;-법제도를 중심으로-)

  • 이원갑
    • The Journal of Fisheries Business Administration
    • /
    • v.25 no.1
    • /
    • pp.19-35
    • /
    • 1994
  • The objective of this study is to analize the system of legal compensation for the fishery loses caused by public works and to suggest alternatives on the current compensation system. Korea government has been performing reclamation activities in coastal region to conduct farm, urban and industrial area, and such activities are still going on in Yeongjongdo airport area, Saemangeum area and so on. Reclamation interrupts fishing activities in or around the reclaiming area, therefore, the compensation for fishery losses incurred by fishermen should be made. The system of legal compensation in Korea, however, is based on the land compensation, and the regulation of the compensation for fishery losses in the Fishery Act can not be applied for the compensation of public works because the procedure of the compensation in the Fishery Act is different from its cause of action. Therefore, this study is caried out to suggest a resonable compensation procedure and to provide a basis for establishing legal system.

  • PDF

A Study on the Reform Measures for the Act on the Acqusition of Land for the Public Undertakings and Compensation : Focused on the Case of Harbor Construction ("공익사업을 위한 토지 등의 취득 및 보상에 관한 법률"에 의한 어업보상 적용사례와 문제점 및 개선방안에 대한 연구 : 항만 개발사업을 중심으로)

  • Moon, Jeong-Gab;Kang, Yong-Joo
    • The Journal of Fisheries Business Administration
    • /
    • v.37 no.3 s.72
    • /
    • pp.85-108
    • /
    • 2006
  • The government enforced 'Act on the acquisition of land for the public undertakings and compensation' commenced on the 1st of January 2003 to faithfully protect the property right of people and to scheme the effiecient drive of public works by systematizing the procedures and the standards of compensation and reforming irrational systems. The previous act regulated to compensate a rightful person of fishery right, who is in a nearby area of public works enforcement zone for actual loss according to the level of damage. On the contrary, as for the fishery damage happened at the outside of public works enforcement zone, the act regulates to compensate for a loss when it is actullay occurred and affirmed. So, the related act was amended as, so called, Post Factum Compensation. With regard to the Post Factum Compensation regulation for the fishery damage occurred at the outside of this public works enforcement zone, many objections and problems are raised as it is not clearly understood of the nature of the fishery compensation. However, this paper is not intended to mention the right or wrong of the current law, but to discuss the problems or remedies of 'Act on the acquisition of land for the public undertakings and compensation' after examining cases of public works which was enforced for the fishery compensation within the current law.

  • PDF

Compensation of an Air-Gapped Current Transformer in the steady state (정상상태에서 공극 변류기의 보상)

  • Kang, Yong-Cheol;Park, Ji-Youn;So, Soon-Hong;Jang, Sung-Il;Kim, Yong-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.15-17
    • /
    • 2006
  • This paper proposes a compensation method for an air gapped current transformer (CT) in the steady state. An air gapped CT is used in order to reduce a remanent flux in the case of auto-reclosure. It causes larger ratio and angle errors than the closed core CT because the magnetizing inductance of an air-gapped CT is even smaller than the closed-core CT. The core flux is calculated and used to estimate the exciting current in accordance with the hysteresis curve of the air-gapped CT The correct current is obtained by adding the estimated exciting current to the measured secondary current. The performance of the method was investigated for the air gapped CTs with a gap of 0.083mm and 0.249mm for the 120%, 100% and 20% of the rated current. Various test results indicate that the proposed compensation algorithm can improves the accuracy significantly.

  • PDF

New current memory cell with clock-feedthrough reduction scheme (클럭-피드쓰루를 개선한 새로운 전류 기억 소자)

  • 민병무;김재완;김수원
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.1
    • /
    • pp.30-34
    • /
    • 1997
  • An improved clock-feedthrough compensation scheme for switche dcurrent system is proposed. Both the signal dependent and the constant clock-feedthrough terms are cancelled by using both NMOS and PMOS current samplers and by adopting a source replication technique. The proposed current memory cell was fabricated with 0.6$\mu$m CMOS process. Both experimental and theoretical results on clock-feedthrough error reveal substantial reduction over the existing compensation schemes.

  • PDF

Eliminating the Neutral Current by the Instantaneous Reactive Power Compensation (순시무효전력 보상에 의한 중성선 전류의 제거)

  • Kim, Hyo-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.131-133
    • /
    • 1998
  • This paper, proposed the p-q-r coordinate system where the instantaneous active power p, and the two instantaneous reactive powers $q_{q}$, $q_{r}$ were defined. The three power components are linearly independent, so the compensation for the two instantaneous reactive powers leads to control the two components of the current space vector. With the theory, the neutral current of the three-phase four-wire system can be eliminated by only compensating the instantaneous reactive power using no energy storage element.

  • PDF

An Integrated Compensation Algorithm for PCC Voltage Fluctuation and Unbalance with Variable Limit of Positive and Negative Sequence Currents

  • Im, Ji-Hoon;Song, Seung-Ho;Cho, Sung-Min
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.751-760
    • /
    • 2017
  • This paper proposes a point of common coupling (PCC) voltage compensation algorithm using a current limitation strategy for use in distributed generation (DG). The proposed strategy maintains the PCC voltage by prioritizing currents when an output current reference is larger than the current capacity of the power condition system (PCS) of the DG. With this strategy, the DG outputs the active current, reactive current, and the negative sequence current. The DG uses the reactive current for maintaining the PCC voltage within a normal range; the negative sequence current is used for reducing the PCC voltage unbalance. The proposed method was verified using PSIM simulation and experimental results.

Analysis and Specifications of Switching Frequency in Parallel Active Power Filters Regarding Compensation Characteristics

  • Guopeng, Zhao;Jinjun, Liu
    • Journal of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.749-761
    • /
    • 2010
  • The switching frequency of a power device is a very important parameter in the design of a parallel active power filter (PAPF), but so far, very little discussion has been conducted on it in a quantitative manner in previous publications. In this paper, an extensive analysis on the effects of the switching frequency on the performance of a PAPF is made, and a specification of the switching frequency values with different compensation results is presented. A first-order inertia element and a second-order oscillation element are considered as approximate models of a PAPF, respectively. The compensation characteristic for each order of harmonic current is obtained at different switching frequencies. Then, the THDs of each model for the system loads of a rectifier with resistance and inductance loads are proposed. The compensation results of a PAPF controlled as a first-order inertia element are better than those of a PAPF controlled as a second-order oscillation element. With two types of system loads which are rectifier with resistance and inductance loads and rectifier with resistance, inductance and capacitance loads, the THDs of the source current after compensation are presented with different switching frequencies. The compensation characteristics for the most widely used digital control system are investigated. The situation with an analog control is the theoretical characteristic and it is the best situation. The compensation characteristic of the digital control is worse than the compensation characteristic of the theoretical characteristic. Based on these analyses, the specifications of compensation characteristics with different switching frequencies are quite straightforward. Finally, a practical design example is studied to verify the application.