• Title/Summary/Keyword: Current(A)

Search Result 64,787, Processing Time 0.07 seconds

DC Current sensor using the saturable magnetic cores (자성체포화를 이용한 DC전류센서)

  • Park, Y.T.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.699-702
    • /
    • 2002
  • A DC current sensor is disclosed in which two pairs of saturable cores are provided so as enclose a conductor carrying a direct current to be measured. On each of the saturable cores, a bias winding, a feedback winding and an output winding are wound. Circuit for detection of an asymmetry in the magnetization current, generated by a reference alternating voltage, in a signal-conditioner. The reference alternating voltage is fed to the respective series circuits such that no resultant induction current is induced in the modulating current. The voltages over the resistor form input signals for two peak value detectors, the strength of the output signal of which represents the degree of asymmetry of magnetization current. This paper describes the development a DC current sensor and its signal-conditioner.

  • PDF

Current Limiting Characteristics of Superconducting Fault Current Limiter for Reduction of Unsymmetrical Fault Current in a Three-Phase Power System (삼상전력계통의 비대칭고장전류 저감을 위한 초전도한류기의 전류제한특성)

  • Kim, Min-Yeong;Lim, Sung-Hun;Hwang, Jong-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.8-8
    • /
    • 2010
  • In this paper, the limiting characteristics of the fault current in a power system with a superconducting fault current limiter(SFCL) applied into neutral line of main transformer in a distribution power line were analyzed. The SFCL applied into the neutral line of main transformer power system can limit the unsymmetrical fault current from the single-line ground fault or the double-line ground fault. In addition, it could be decreased a number of SFCL and a load. This method could be expected to reduction of a power loss in the neutral line, because of a neutral line current is zero in ordinary times.

  • PDF

A CMOS Rail-to-Rail Current Conveyer and Its Applications to Current-Mode Filters

  • Kurashina, Takashi;Ogawa, Satomi;Watanabe, Kenzo
    • Proceedings of the IEEK Conference
    • /
    • 2002.07b
    • /
    • pp.755-758
    • /
    • 2002
  • This paper presents a second-generation CMOS current conveyor (CCII) consisting of a rail-to-rail complementary N- and P-channel differential input stage for the voltage input, a class AB push-pull stage for the current input, and current mirrors far the current outputs. The CCII was implemented using a double-poly triple-metal 0.6 ${\mu}$m n-well CMOS process, to confirm its operation experimentally. A prototype chip achieves a rail-to-rail swing ${\pm}$2.4 V under ${\pm}$2.5 V power supplies and shows the exact voltage and current following performances up to 100 MHz. Because of its high performances, the CCII proposed herein is quite useful for a building block of current-mode circuits. The applications of the proposed CCII to current-mode filters are also described.

  • PDF

Novel Current Compensation Technique for Harmonic Current Elimination (고조파 전류 제거를 위한 새로운 전류 보상 기법)

  • Jeong Gang-Youl
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.587-591
    • /
    • 2004
  • This paper proposes a novel current compensation technique that can eliminate the harmonic currents included in line currents without computation of harmonic current components. A current controller with fast dynamics for an active filter is described. Harmonic currents are directly controlled without the need for sensing and computing the harmonic current of the load current, thus simplifying the control system. Current compensation is done in the time domain, allowing a fast time response. The DC voltage control loop keeps the voltage across the DC capacitor constant. High power factor control by an active filter is described. All control functions are implemented in software using a single-chip microcontroller, thus simplifying the control circuit. Any current-controlled synchronous rectifier can be used as a shunt active filter through only the simple modification of the software and the addition of current sensors. It is shown through experimental results that the proposed controller gives good performance for the shunt active filter.

  • PDF

Determination of Polarization Resistance by Harmonic Current Measurements (조화 전류 측정에 의한 분극 저항 평가)

  • Kim, Jong Jip;Yu, Mi Young
    • Corrosion Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.247-256
    • /
    • 2012
  • Harmonic current was measured for a dummy cell with various values of resistance, and the procedure developed through the measurements was applied to the investigation of effects of the amplitude of applied frequency and applied potential on the harmonic current of a stainless steel and a carbon steel in chloride containing solutions. From the measurements of harmonic current in the dummy cell, the optimum values of applied frequency and applied potential in harmonic current measurements were found to be 1 mHz and 20 mV (or lower), respectively. Increase in harmonic current with applied frequency was observed in the case where the level of harmonic current is low as in a stainless steel. Decrease in polarization resistance was also noted in this corrosion system with either increasing applied frequency or decreasing applied potential. However, no obvious effects of applied frequency was observed on harmonic current and polarization resistance in a carbon steel in which the level of harmonic current is high.

A Study on Railway Electric Traction Protection System (전철용 보호계전기 시스템에 관한 연구)

  • Lee, Hee-Yong;Kim, Wang-Gon;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1390-1395
    • /
    • 2004
  • Recently, the load increasement and new regenerative systems of electrified railway system make it a difficult to distinguish between the load current and fault current. The failure of traction system perhaps causes over-current to flow. The high current can collapse other railway systems. If failures of the traction system takes place, the failures are detected and protected lest it should provoke high current flow. The over current from such a traction system failure permit to charge high tension voltage and produces high temperature arc, voltage instability, current cutting, and break down railway systems. The traction system failures detect and the system has to immediately cut off from over-current flow. To isolate the failure, the system can distinguish failure current from current flows. It forces us to adapt such as a new intelligent protection system. The protective system in traction system play a role of detecting and isolating failure points. In this paper, we proposed intelligent algorithm for discriminating normal and abnormal situation instead of the system being operated abnormally.

  • PDF

Quench characteristics of HTS tapes applied over-current (과전류 인가 시 고온초전도 선재의 ?치 특성)

  • 임성우;최용선;황시돌;한병성
    • Progress in Superconductivity
    • /
    • v.4 no.2
    • /
    • pp.184-188
    • /
    • 2003
  • Voltage-current characteristics of High Temperature Superconductor(HTS) tapes after applying the current beyond their critical current was investigated. When over-current is applied, the current begins to flow through the metal sheath instead of superconductor. The HTS tapes quenched were analyzed using V-I curve with various magnitudes of current. Two kinds of tapes were compared with each other to examine the influence of critical current on quench development. As a result, it was found that the resistance of superconductors and joule heat due to the over-current affect current distribution in HTS tapes. Critical current of HTS tapes was considered as a main factor deciding over-current characteristics.

  • PDF

Reduction of Minimum Switching Duration in the Measurement of Three Phase Current with DC-Link Current Sensor (DC링크 전류센서를 이용한 삼상전류 측정 방식에서 최소 스위칭 시간의 단축)

  • 김경서
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.12
    • /
    • pp.649-654
    • /
    • 2003
  • The simplest method for measuring output currents of the three phase inverters is to measure them with three current sensors such as hall sensors. This method requires at least two current sensors, and these types of sensors are somewhat expensive. More economical method is measuring DC link current with a simple shunt resistor, then, reconstructing output current using the DC link current value and the switching status. However, in low speed region, the measurement becomes difficult and even impossible due to the requirement of minimum switching duration for A/D conversion. These problems can be overcome by limitation of switching duration. Limitation of switching, however, causes voltage and current distortion. Owing to compensation, distortion can be effectively suppressed. However these increase acoustic noise due to increment of current ripple. In this paper, a current measurement method is proposed, which can reduce minimum switching duration resulting in reduction of acoustic noise. The validity of proposed method is confirmed through experiment.

Analysis on the Short Circuit Current of a Low Voltage Direct Current(DC) Distribution System using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 저전압 직류 배전 시스템의 단락 고장 전류 분석)

  • Ahn, Jae-Min;Jeon, Jeong-Chay;Lim, Young-Bae;Bae, Seok-Myeong;Byeon, Gil-Sung;Lee, Kyoung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.473-476
    • /
    • 2010
  • In this paper, we analyzed the short circuit current of a low voltage direct current distribution system. For the analysis, we performed the modeling of the low voltage direct current distribution system with a 6-pulse three-phase thyristor rectifier using the PSCAD/EMTDC, surveyed impedance of sources, transformers and distribution lines to run a simulation. A result of the simulation is that short circuit currents of the direct current distribution system with the rectifier decreased due to a thyristor-ON-resistance(Ron). But in case of the low thyristor-ON resistance, output fault current of the rectifier increased over three-phase short circuit current of an AC power system without a rectifier by regular ratio of the rectifier. Because the output fault current of the rectifier can increase over interrupting the capacity of circuit breakers, studying short circuit currents of a low voltage direct current distribution system with a rectifier is necessary for introducing the direct current distribution systems.

A Modified Current Differential Relay for Transformer Protection (변압기 보호용 수정 전류차동 계전방식)

  • 강용철;김은수;원성호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.2
    • /
    • pp.80-86
    • /
    • 2004
  • During magnetic inrush or over-excitation, saturation of the core in a transformer draws a large exciting current, which can cause mal-operation of a differential relay. This paper proposes a modified current differential relay for transformer protection. The relay calculates core-loss current from the induced voltage and the core-loss resistance; the relay calculates the magnetizing current from the core flux and the magnetization curve. Finally, the relay obtains the modified differential current by subtracting the core-loss and the magnetizing currents from the conventional differential current. Comparison study with the conventional differential relay with harmonic blocking is also shown. The proposed technique not only discriminates magnetic inrush and over-excitation from an internal fault, but also improves the speed of the conventional relay.