• Title/Summary/Keyword: Curing depth

Search Result 128, Processing Time 0.023 seconds

The Effect of Changes in Early Low-Temperatures in Early-Frost Damage Depth (초기 저온의 온도변화가 초기동해 깊이에 미치는 영향)

  • Kim, Tae-Woo;Kim, Min-Sang;Moon, Byeong-Yong;Lee, Jea-Hyun;Kim, Dong-Gyu;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.207-208
    • /
    • 2017
  • The current study assumed a condition in which concrete curing was not completed correctly in the winter, in order to analyze the effect of changes in early low-temperatures in early-frost damage depth. As a result, lower external temperature early on after depositing the concrete greatly reduced the temperature in the upper parts of the concrete, and it delayed the time during which the concrete temperature restored. In addition, for early-frost damages, lower early temperature increased the expansion of frozen water, which in turn relaxes the concrete structures and increases the absorption rate, ultimately extending the depth of early-frost damage.

  • PDF

A STUDY ON THE CHANGES IN DEGREE OF CONVERSION OF DUAL-CURE RESTORATIVE MATERIALS WITH TIME-ELAPSE (이중중합 수복재의 시간경과에 따른 중합도 변화)

  • Yang, Chul-Ho;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.3
    • /
    • pp.554-563
    • /
    • 1999
  • For the purpose of elucidating the polymerization modes of dual-cure restorative materials and comparing them with single-cure restorative materials, a study was performed on the light-cured composite resin, dual-cure composite resin, dual-cure glass ionomer cement and chemical-cure glass ionomer cement. By measuring the microhardness of each material at 0mm, 1mm and 3mm depth during initial 24 hours with predetermined interval, the state of polymerization and degree of conversion was indirectly evaluated for each material, and obtained results are as follows : 1. All of four materials tested showed significant increase in microhardness after 24hrs compared with just after curing starts. 2. In all materials except Ketac-fil, there showed a significant difference in microhardness between each depth at each time interval. 3. In the test of lap time till final curing for each material, the polymerization process was revealed to last longer in the dual-cure type materials than in single-cure type materials at 3mm depth. Based on the results above, it was demonstrated with materials of dual-cure mode that the degree of conversion increases by successive curing reactions even in the deeper layers where sufficient curing light is impermeable.

  • PDF

THE POLYMERIZATION RATE AND THE DEGREE OF CONVERSION OF COMPOSITE RESINS BY DIFFERENT LIGHT SOURCES (광원의 종류에 따른 복합레진의 중합거동 및 중합률에 관한 연구)

  • Ryoo, Joo-Hee;Lee, In-Bog;Yoo, Hyun-Mee;Kim, Mi-Ja;Seok, Chang-In;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.4
    • /
    • pp.386-398
    • /
    • 2004
  • Objectives: The purpose of this study was to observe the reaction kinetics and the degree of polymerization of composite resins when cured by different light sources and to evaluate the effectiveness of the blue Light Emitting Diode Light Curing Units (LED LCUs) compared with conventional halogen LCUs. Materials and Methods: First, thermal analysis was performed by a differential scanning calorimeter (DSC). The LED LCU (Elipar Freelight, $320{\;}mW/\textrm{cm}^2$) and the conventional halogen LCU (XL3000, $400{\;}mV/\textrm{cm}^2$) were used in this study for curing three composite resins (SureFil, Z-250 and AEliteFLO). Second. the degree of conversion was obtained in the composite resins cured according to the above curing mode with a FTIR. Third, the measurements of depth of cure were carried out in accordance with ISO 4049 standards. Statistical analysis was performed by two-way ANOVA test at 95% levels of confidence and Duncan's procedure for multiple comparisons. Results: The heat of cure was not statistically different among the LCUs (p > 0.05). The composites cured by the LED (Exp) LCUs were statistically more slowly polymerized than by the halogen LCU and the LED (Std) LCU (p < 0.05). The composite resin groups cured by the LED (Exp) LCUs had significantly greater degree of conversion value than by the halogen LCU and the LED (Std) LCU (p =0.0002). The composite resin groups cured by the LED (Std) LCUs showed significantly greater depth of cure value than by the halogen LCU and the LED (Exp) LCU (p < 0.05).

Mechanical Properties According to Curing Conditions of Mortar Using CO2 Hardening Cement (CO2 반응경화 시멘트 활용 모르타르의 양생조건에 따른 역학적 특성)

  • Ji-Seok Seo;Sun-Gyu Tae;Jun Lee;Bong-Chun Lee
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.4
    • /
    • pp.307-315
    • /
    • 2023
  • In this study, mortar test specimens were produced by varying the mixing ratio of CO2 reaction hardening cement (CSC) and general cement (OPC), and the mechanical and carbonation characteristics were evaluated by controlling the primary curing temperature and secondary curing CO2 pressure. Under all curing conditions, it was observed that the higher the CSC ratio in the binder, the lower the mechanical properties. Specifically, a first curing temperature of 60 ℃ yielded higher mechanical properties compared to the case of 20 ℃, and a greater carbonation penetration depth was also observed. At a first curing temperature of 60 ℃, it was noted that the curing pressure and bending strength during the second CO2 curing were inversely proportional, while the compressive strength showed a proportional relationship. This phenomenon is believed to be due to excessive carbonation, which reduces mechanical properties, and the fact that flexural strength is more sensitive to these properties compared to compressive strength. However, based on the evaluation of the limited curing conditions, it is evident that future test conditions need to be expanded and reviewed more thoroughly.

An Experimental Study on the Carbonation Depth of Cement Paste Using Carbonation Reaction Accelerator (탄산화 반응 촉진제를 이용한 시멘트 페이스트의 탄산화 깊이에 관한 실험적 연구)

  • Seok-Man Jeong;Wan-Hee Yang;Dong-Cheol Park
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.4
    • /
    • pp.349-354
    • /
    • 2023
  • This study wa s conducted a s pa rt of ma ximizing the use of ca rbon dioxide by a pplying CCU(Ca rbon Ca pture, Utiliza tion) a mong technologies for reducing CO2 in the cement industry. In a carbon dioxide curing environment, changes in carbonation depth and changes in basic physical properties by age due to the mixing of carbonation reaction accelerators were usually targeted at Portland cement paste. In addition, in order to check the fixed amount of CO2 in the concrete field, a thermal analysis method was applied to evaluate CaCO3 decarbonization at high temperatures. As a result of the evaluation, it was confirmed that the carbonation depth in the cured body significantly increased due to the incorporation of CRA in the carbonation depth diffusion performance. In addition, it was confirmed that the weight reduction rate increased by 23.8 % and 40.77 %, respectively, compared to Plain, in the order of curing conditions for constant temperature and humidity and curing conditions for carbonation chambers, so it was confirmed that the amount of excellent CaCO3 produced by the addition of CRA increased as the concentration of CO2 increased.

THE INFLUENCE OF CURING WITH LIGHT TRANSMITTING WEDGE INSERTED INTO THE COMPOSITE RESIN BODY ON THE DEGREE OF MICROLEAKAGE AND MICROHARDNESS (광 전달 쐐기를 이용한 중합 방법이 레진 충전물의 미세 누출과 미세 경도에 미치는 효과)

  • Suh, Yong-Seok;Kim, Yong-Kee;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.4
    • /
    • pp.731-748
    • /
    • 1998
  • The purpose of this study was to test the hypothesis that the more thorough cure of lightactivated composite resin could be obtained if a new way of delivering the light source deep through the resin body is developed when compared to the conventional bulk cure or incremental cure. Using cylindrical resin blocks and natural teeth, various curing conditions were tested for their effects on the degree of microleakage and microhardness. Data were analyzed statistically using One-Way ANOVA and Scheff's Multiple Range test. The results of the present study were as follows: 1. The increment of reduction in microhardness with depth was shown to be higher in group I and II than in group II and V. 2. At the level of lower inner surface and the bottom surface, significantly lower microhardness values were obtained in group I and II when compared to group III, IV and V. Group IV showed the lowest value among three groups(III, IV, V) representing the only statistically significant difference from group V(p<05). 3. Differences between groups in the degree of microleakage detected were shown to be statistically significant (p<05) with the exception of group IV and V at both occlusal and gingival margins. 4. Based upon the above-mentioned results, commonly cited recommendation of incremental curing is strongly supported and the light-transmitting wedge insertion method can be considered as a effective and feasible clinical procedure for the better curing of composite resin. However, more studies under a variety of conditions should be completed before this method is applied actually to the clinical setting.

  • PDF

EFFECT OF LIGHT SOURCE AND SHADE ON DEPTH OF CURE OF COMPOSITES (중합광원과 레진 색상이 복합레진의 중합깊이에 미치는 영향)

  • Na, Joon-Sok;Jeong, Sun-Wa;Hwang, Yun-Chan;Kim, Sun-Ho;Yun, Chang;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.6
    • /
    • pp.561-568
    • /
    • 2002
  • Purpose of this research is estimating polymerization depth of different source of light. XL 3000 for halo-gen light, Apollo 95E for plasma arc light and Easy cure for LED light source were used in this study. Different shade (B1 & A3) resin composites (Esthet-X, Dentsply, U.S.A.) were used to measure depth of cure. 1, 2, and 3 mm thick samples were light cured for three seconds, six seconds or 10 seconds with Apollo 95E and they were light cured with XL-3000 and Easy cure for 10 seconds, 20 seconds, or 40 seconds. Vicker's hardness test carried out after store samples for 24 hours in distilled water. Results were as following. 1. Curing time increases from al1 source of lights, oui$.$ing depth increased(p<0.05). 2. Depth (that except 1mm group and 2mm group which lighten to halogen source of light) deepens in all groups, Vickers hardness decreased(p<0.05). 3. Vicker's hardness of A3 shade composite was lower in all depths more than B1 shade composites in group that do polymerization for 10 seconds and 20 seconds using halogen source of light(p<0.05), but group that do polymerization lot 40 seconds did not show difference(p>0.05). 4. Groups that do polymerization using Plasma arc and LED source of light did not show Vicker's hardness difference according to color at surface and 1mm depth(p>0.05), but showed difference according to color at 2mm and 3mm depth(p<0.05). The results showed that Apollo 95E need more polymerization times than manufacturer's recommendation (3 seconds), and Easy cure need polymerization time of XL-3000 at least.

A study on the drying characteristics of conductive ink by oven drying system and the hot-air drying system (Oven형 건조 및 열풍건조에 대한 전도성 잉크의 건조 특성에 관한 연구)

  • Hong, Seung-Chan;Lee, Jai-Hyo;Jung, Gil-Yong
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1429-1434
    • /
    • 2009
  • Recently electronic circuit pattern printing technologies like antennas of RFID process are paid attention. oven drying system is being used since drying and curing time of RFID Tag Gravure printing normally takes from 5 minutes and up to 30 minutes long. In this case the parental material which is of a sheet shape is possible, however, for a massive and a continuous production drying and curing process must be done on-line. This research compared and analyzed the an oven type drying device and a traditional hot-air drying device. Considering the experiment result, the cell depth that shows low resistivity, which doesn't consider the pattern difference, is $31{\sim}33{\mu}m$. Also, oven drying system showed some resistivity after around 120 seconds of drying time, and showed much better performance in minimum resistivity compared to the hot-air drying system.

  • PDF

Comparison of polymerization by time of light curing for dental 3D printing (치과 3D 프린팅용 광중합 시간에 따른 중합도 비교)

  • Kim, Dong-Yeon;Lee, Gwang-Young
    • Journal of Technologic Dentistry
    • /
    • v.44 no.3
    • /
    • pp.76-80
    • /
    • 2022
  • Purpose: The purpose of this study is to analyze the depth according to curing using photocurable resin for dental three-dimensional printing. Methods: A stainless mold with a height of 4 mm was prepared. Ultraviolet (UV) polymerization resin was injected into the mold. Photocuring was then performed for 5 minutes using a photopolymerizer, and the height was measured using a digital measuring instrument (first group). Second, light polymerization was also performed outside the mold for 5 minutes, and the height was measured using a digital measuring instrument. Third, light polymerization was further performed for 5 minutes, and the height was measured using a digital measuring instrument. Statistical analysis was performed with the Kruskal-Wallis test, which is a nonparametric test (α=0.05). Results: The third group had the largest measurement length, whereas the first group had the smallest. However, the difference between groups was not statistically significant (p>0.05). The color of the first group was different from that of the second and third groups. Conclusion: All of the 4-mm-thick photocured specimens had a curing reaction, but the part that was not directly irradiated with UV did not show its original color.

Geotechnical behaviour of nano-silica stabilized organic soil

  • Kannan, Govindarajan;Sujatha, Evangelin Ramani
    • Geomechanics and Engineering
    • /
    • v.28 no.3
    • /
    • pp.239-253
    • /
    • 2022
  • Suitable techniques to stabilize organic soil and improve its engineering behaviour are in demand. Despite various alternatives, nano-additives proved to be an effective stabilizer owing to their strength enhancing properties. The study focuses on using nano-silica as a potential stabilizer to improve organic silt. Soil was treated with four dosages of nano-silica namely 0.2%, 0.4%, 0.6% and 0.8% of dry weight of the soil. Nano-silica treated soil showed a strength increase of nearly 25% at a dosage of 0.4% after curing for two hours. Strength of the treated soil improved with age. Strength improved by nearly 62.9% after 28 days of curing and 221.4% after 180 days of curing due to formation of Calcium - Silicate - Hydrate (CSH) gel in the soil matrix. Dosage of 0.6% nano-silica is observed to be the optimum dosage. Coefficient of permeability and compression index showed an increase by 13.32 and 5.5 times respectively owing to aggregation of particles and creation of void spaces as visualized from the scanning electron micrographs. Further model foundation study and numerical parametric studies using PLAXIS 2D indicate that optimized and economic results can be obtained by varying the additive dosage with depth.