• Title/Summary/Keyword: Curing Apparatus

Search Result 24, Processing Time 0.02 seconds

The Effect of Jakamchotang(炙甘草湯) on Isolated rat herts under langendorff apparatus (자감초탕(炙甘草湯)이 재관류장치하에서 흰쥐의 적출심장(摘出心臟)에 미치는 영향(影響))

  • Moon, Hyung-Kun;Moon, Sang-Kwan;Ko, Chang-Nam;Cho, Ki-Ho;Kim, Young-Suk;Bae, Hyung-Sup;Lee, Kyung-Sup
    • The Journal of Korean Medicine
    • /
    • v.18 no.2
    • /
    • pp.340-354
    • /
    • 1997
  • Background : The stenosis of the coronary artery results in a decrease in the myocardial oxygen supply, ischemia and infarction. Jakamchotang as a drug of liquid is generally regarded to have the effect of arrythmia, palpitation from Heart disease and promoting the flow of Ki and Blood. Methods : The purpose of this experimental study is to find whether Jakamchotang is effective or not in curing ischemia in isolated perfused rat hearts and to measure the degree of its curing effect. In this study, under the Langendorff apparatus, ischemia was induced in isolated Sprague-Dawley rat hearts by ceasing the perfusion for 20 minites. Subjects were divided into a normal saline orally administered group(control group), an Jakamchotang orally 100mg administered group (sample A), an Jakamchotang orally 300mg administered group (sample B), and an Jakamchotang injection perfused group(sample C). The heart rates, left ventricular pressure, myocardial dilatation/contraction, cardiac perfusion flow and cardiac ezyme(LDH, CPK) of the four group were measured and compared in order to assess the influence of Jakamchotang on isolated perfused rat hearts recovering abillity from ischemia and infarction. results : 1. Heart rates were increased significantly in Jakamchotang orally 100mg administered group, Jakamchotang orally 300mg administered group and Jakamchotang injection perfused group on perfusion and reperfusion(p<0.01). 2. Left ventricular pressure were increased significantly in Jakamchotang orally 100mg administered group and 300mg administered and Jakamchotang injection perfused group(p<0.01) in comparison with control group on perfusion, but every group did not significant on reperfusion. 3. While there were no differances in each group's abillities of myocardial dilatation, the ability of myocardial constriction of Jakamchotang 100mg administered group only on perfusion was significantly greater than that of control group(p<0.05). 4. CBF was no significant on perfusion and reperfusion in comparison with control group(N.S.) 5. LDH was not significantly decreased on perfusion, but significactly decreased in Jakamchotang orally 100mg administered group, Jakamchotang orally 300mg administered group on reperfusion. 6. CPK was significantly decreased in Jakamchotang orally 100mg administered group, 300mg administered and Jakamchotang injection perfused group on perfusion(p<0.01), but was not significantly in Jakamchotang 300mg administered group only on reperfusion(P<0.05) Conclusion : According to the result above, Jakamchotang have an effect to recover in the isolated perfused rat hearts. Especially, the effect of Jakamchotang in orally adminstered group is greater than that of Jakamchotang injection perfused group on preischemia. The followings are the two important results of this study: First, the effect of Jakamchotang used traditionally on heart disease was proved statistcally under the Langendorff apparatus. Second, on the basis of this study, the effect of other type medications on myocardial ischemia can be evaluted in further studies.

  • PDF

Effects of soaking on a lime stabilized clay and implications for pavement design

  • Bozbey, Ilknur;Kelesoglu, M. Kubilay;Oztoprak, Sadik;Komut, Muhammet;Comez, Senol;Ozturk, Tugba;Mert, Aykan;Ocal, Kivilcim
    • Geomechanics and Engineering
    • /
    • v.24 no.2
    • /
    • pp.115-127
    • /
    • 2021
  • This paper investigates the effects of soaking on a lime stabilized high plasticity clay and evaluates the implications for pavement design. In this context, the soil was stabilized by 4%, 6% and 9% hydrated lime. The soil was pulverized in two different gradations so that representative field gradations could be simulated. Both soil pulverization levels passed the relevant field gradation criteria. Curing durations were chosen as 7 days, 28 days and 56 days. Two groups of samples were prepared and were tested in unconfined compression test apparatus to measure the strength and secant modulus at failure values. One of the groups was tested immediately after curing. The other group of samples were first cured and then subjected to soaking for ten days before testing. Visual observations were made on the samples during the soaking period. The results showed the superiority of fine soil pulverization over coarse soil pulverization for unsoaked conditions in terms of strength and modulus values. Soaking of the samples affected the unconfined compressive strength and modulus values based on lime content, curing duration and soil pulverization level. In soaked samples, fine soil pulverization resulted in higher strength and modulus values compared to coarse soil pulverization. However, even with fine soil pulverization, effects of soaking on modulus values were more significant. A new term named as "Soaking Influence Factor (SIF)" was defined to compare the reduction in strength and modulus due to soaking. The data was compared with the relevant design guidelines and an attempt was made to include Soaking Influence Factors for strength and modulus (SIFS and SIFM) into pavement design processes. Two equations which correlated secant modulus at failure to unconfined compressive strength were proposed based on the samples subjected to soaking. The results of this study showed that in order to decrease the diverse effects of soaking for lime stabilized soils, soil pulverization level should be kept as fine as possible in the field. Importance of proper drainage precautions in the pavements is highlighted for better performance of the pavements.

Development of Material Switching System for Microstructure with Multiple Material in Projection Microstereolithography (전사방식 마이크로 광 조형에서 복합 재료의 미세구조물 제작을 위한 수지 교한 시스템 개발)

  • Jo, Kwang-Ho;Park, In-Baek;Ha, Young-Myoung;Kim, Min-Sub;Lee, Seok-Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.8
    • /
    • pp.1000-1007
    • /
    • 2011
  • For enlarging the applications of microstereolithography, the use of diverse materials is required. In this study, the material switching system (MSS) for projection microstereolithography apparatus is proposed. The MSS consists of three part; resin level control, resin dispensing control, and vat level control. Curing characteristic of materials used in fabrication has been identified. Through repeated fabrication of test models, the critical fabrication error is investigated and a possible solution to this error is suggested. The developed system can be applied to improve the strength of microstructure and extended to fabricate an array of microstructures with multiple materials.

Application of 3D printer in dental clinic (치과 진료실에서 3D 프린트의 활용)

  • Kim, Hyun Dong
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.27 no.2
    • /
    • pp.82-96
    • /
    • 2018
  • 3D printing is a process of producing 3d object from a digital file in STL format by joining, bonding, sintering or polymerizing small volume elements by layer. The various type of 3d printing is classified according to the additive manufacturing strategies. Among the types of 3D printer, SLA(StereoLithography Apparatus) and DLP(Digital Light Processing) 3D printer which use polymerization by light source are widely used in dental office. In the previous study, a full-arch scale 3d printed model is less precise than a conventional stone model. However, in scale of quadrant arch, a 3d printed model is significantly precise than a five-axis milled model. Using $3^{rd}$ Party dental CAD program, full denture, provisional crowns and diagnostic wax-up model are fabricated by 3d printer in dental office. In Orthodontics, based on virtual setup model, indirect bracket bonding tray can be generated by 3d printer. And thermoforming clear aligner can be fabricated on the 3d printed model. 3D printed individual drilling guide enable the clinician to place the dental implant on the proper position. The development of layer additive technology enhance the quality of 3d printing object and shorten the operating time of 3D printing. In the near future, traditional dental laboratory process such as casting, denture curing will be replaced by digital 3D printing.