• Title/Summary/Keyword: Ct-parameter

Search Result 138, Processing Time 0.034 seconds

The Difference of Standardized Uptake Value on PET-CT According to Change of CT Parameters (PET-CT에서 CT의 관전압 및 관전류에 따른 SUV값의 변화)

  • Shin, Gyoo-Seul;Dong, Kyeong-Rae
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.373-379
    • /
    • 2007
  • Purpose : There is difference between PET and PET/CT method on their transmission image for attenuation correction. The CT image is used for attenuation correction on PET/CT and the parameters of CT may be affected on PET image. We performed the phantom study to evaluate whether the change of CT parameters(kilovolts peak and milliampere) affect standardized uptake value(SUV) on PET image. Material and Method: The data spectrum lung phantom containing diluted [18F]fluorodeoxyglucose ([18F]FDG) solution(1.909 mCi for phantom 1, $913\;{\mu}Ci$ for phantom 2) was used. The CT images of phantom were acquired with varying parameters (80, 100, 120, 140 for kVp, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100 for mA). The PET images were reconstructed with the each CT images and SUVs were compared. Result : The SUVs of phantom 1 reconstructed with each 80, 100, 120 and 140 kVp showed $12.26{\pm}0.009$, $12.27{\pm}0.005$, $12.27{\pm}0.006$ and $12.27{\pm}0.009$, respectively. The SUVs of phantom 2 revealed $4.52{\pm}0.043$, $4.53{\pm}0.004$, $4.52{\pm}0.007$ and $4.52{\pm}0.005$ with elevation of voltage. There was no statistically significant difference of SUVs between groups based on various kVp. Also SUVs of phantom 1 and 2 showed no significant change with elevation of milliampere in CT parameter. Conclusion : The parameters of CT did not significantly affect SUV on PET image in our study. Therefore we can apply various parameters of CT appropriated for clinical conditions without significant change of SUV on PET CT image.

  • PDF

Influence of Regularization Parameter on Algebraic Reconstruction Technique (대수적 재구성 기법에서 정규화 인자의 영향)

  • Son, Jung Min;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.679-685
    • /
    • 2017
  • Computed tomography has widely been used to diagnose patient disease, and patient dose also increase rapidly. To reduce the patient dose by CT, various techniques have been applied. The iterative reconstruction is used in view of image reconstruction. Image quality of the reconstructed section image through algebraic reconstruction technique, one of iterative reconstruction methods, was examined by the normalized root mean square error. The computer program was written with the Visual C++ under the parallel beam geometry, Shepp-Logan head phantom of $512{\times}512$ size, projections of 360, and detector-pixels of 1,024. The forward and backward projection was realized by Joseph method. The minimum NRMS of 0.108 was obtained after 10 iterations in the regularization parameter of 0.09-0.12, and the optimum image was obtained after 8 and 6 iterations for 0.1% and 0.2% noise. Variation of optimum value of the regularization parameter was observed according to the phantom used. If the ART was used in the reconstruction, the optimal value of the regularization parameter should be found in the case-by-case. By finding the optimal regularization parameter in the algebraic reconstruction technique, the reconstruction time can be reduced.

Evaluation of Standardized Uptake Value applying EQ PET across different PET/CT scanners and reconstruction (PET/CT 장비와 영상 재구성 차이에 따른 EQ PET을 이용한 표준섭취계수의 평가)

  • Yoon, Seok Hwan;Kim, Byung Jin;Moon, Il Sang;Lee, Hong Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.35-42
    • /
    • 2018
  • Purpose Standardized uptake value(SUV) has been widely used as a quantitative metric of uptake in PET/CT for diagnosis of malignant tumors and evaluation of tumor therapy response. However, the SUV depends on various factor including PET/CT scanner specifications and reconstruction parameter. The purpose of this study is to validate a EQ PET to evaluate SUV across different PET/CT systems. Materials and Methods First, NEMA IEC body phantom data were used to calculate the EQ filter for OSEM3D with PSF and TOF reconstruction from three different PET/CT systems in order to obtain EARL compliant recovery coefficients of each spheres. The Biograph true point 40 PET/CT images were reconstructed with a OSEM3D+PSF reconstruction, images of the Biograph mCT 40 and Biograph mCT 64 PET/CT scanners were reconstructed with a OSEM3D+PSF, OSEM3D+TOF, OSEM3D+PSF+TOF. Post reconstructions, the proprietary EQ filter was applied to the reconstruction data. Recovery coefficient can be estimated by ratio of measured to true activity concentration for spheres of different volume and coefficient variability(CV) value of RC for each sphere was compared. For clinical study, we compared SUVmax applying different reconstruction algorithms in FDG PET images of 61 patients with lung cancer using Biograph mCT 40 PET/CT scanner. Results For the phantom studied, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.05, 0.04, 0.04 and 0.03 respectively for RC. Application of the proprietary EQ filter, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.04, 0.03, 0.03 and 0.02 respectively for RC. Clinical study, there were no statistical significance of the difference applying EQ PET on SUVmax of 61 patients FDG PET image. (p=1.000) Conclusion This study indicates that CV values of RC in phantom were decreased after applying EQ PET for different PET/CT system and The EQ PET reduced reconstruction dependent variation in SUVs for 61 lung cancer patients, Therefore, EQ PET will be expected to provide accurate quantification when the patient is scanned on different PET/CT system.

Seasonal Variation in Carcass Characteristics of Korean Cattle Steers

  • Piao, M.Y.;Baik, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.28 no.3
    • /
    • pp.442-450
    • /
    • 2015
  • Climate temperature affects animal production. This study was conducted to evaluate whether climatic conditions affect beef carcass characteristics of Korean cattle steers. The monthly carcass characteristics of Korean cattle steers (n = 2,182,415) for 8 yr (2006 through 2013) were collected from the Korean Institute for Animal Products Quality Evaluation. Daily climate temperature (CT) and relative humidity (RH) data were collected from the Korean Meteorological Administration. Weather conditions in South Korea during summer were hot and humid, with a maximum temperature of $28.4^{\circ}C$ and a maximum RH of 91.4%. The temperature-humidity index (THI), calculated based on CT and RH, ranges from 73 to 80 during summer. Winter in South Korea was cold, with a minimum temperature of $-4.0^{\circ}C$ and a wind-chill temperature of $-6.2^{\circ}C$. Both marbling score (MS) and quality grade (QG) of Korean cattle steer carcasses were generally best (p<0.05) in autumn and worst in spring. A correlation analysis showed that MS and QG frequencies were not associated (p>0.05) with CT. Yield grade (YG) of Korean cattle steer carcasses was lowest (p<0.05) in winter (November to January) and highest in spring and summer (May to September). A correlation analysis revealed that YG frequency was strongly correlated ($r{\geq}0.71$; p<0.01) with CT and THI values. The rib eye area, a positive YG parameter, was not associated with CT. Backfat thickness (BT), a negative YG factor, was highest in winter (November and December). The BT was strongly negatively correlated ($r{\leq}-0.74$; p<0.01) with CTs. Therefore, the poor YG during winter is likely due in part to the high BT. In conclusion, YG in Korean cattle steer carcasses was worst in winter. QGs were not associated with winter or summer climatic conditions.

Optimization of Exposure Parameters in Brain Computed Tomography (두부 전산화단층촬영에서 노출 파라미터의 최적화)

  • Ko, Seong-Jin;Kang, Se-Sik
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.355-362
    • /
    • 2010
  • This study determines a range of CT parameter values in Brain CT which are minimizing patient absorption dose without compromising the image quality and optimal exposure condition. We measured dose and image noise using conventional CT parameters in Brain CT. In additon, we evaluated dose, SNR and PSNR of head phantom images while changing kVp and rotation time. In this study, effectiveness of dose that was achieved from dose reproducible experiments in conventional head CT condition is determined by changing kVp and rotation time. Dose and PSNR is related to low dose-high resolution condition. In conclusion, we suggest that using proposed conditions is effective for imaging to compare with conditions proposed by the manufacturer.

Quantitative Analysis of Factors Affecting Cobalt Alloy Clip Artifacts in Computed Tomography

  • Sim, Sook Young;Choi, Chi Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.5
    • /
    • pp.400-404
    • /
    • 2014
  • Objective : Clip artifacts limit the visualization of intracranial structures in CT scans from patients after aneurysmal clipping with cobalt alloy clips. This study is to analyze the parameters influencing the degree of clip artifacts. Methods : Postoperative CT scans of 60 patients with straight cobalt alloy-clipped aneurysms were analyzed for the maximal diameter of white artifacts and the angle and number of streak artifacts in axial images, and the maximal diameter of artifacts in three-dimensional (3-D) volume-rendered images. The correlation coefficient (CC) was determined between each clip artifact type and the clip blade length and clip orientation to the CT scan (angle a, lateral clip inclination in axial images; angle b, clip gradient to scan plane in lateral scout images). Results : Angle b correlated negatively with white artifacts (r=-0.589, p<0.001) and positively with the angle (r=0.636, p<0.001) and number (r=0.505, p<0.001) of streak artifacts. Artifacts in 3-D images correlated with clip blade length (r=0.454, p=0.004). Multiple linear regression analysis revealed that angle b was the major parameter influencing white artifacts and the angle and number of streak artifacts in axial images (p<0.001), whereas clip blade length was a major factor in 3-D images (p=0.034). Conclusion : Use of a clip orientation perpendicular to the scan gantry angle decreased the amount of white artifacts and allowed better visualization of the clip site.

Variation of A2 with Crack Propagation in a Ductile Metal; Experimental Evaluation (연성재료의 균열진전에 따른 A2의 변화; 실험적 측정)

  • Kim, Heon-Joong;Kim, Dong-Hak;Yang, Kyeong-Jin;Kang, Ki-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.1
    • /
    • pp.119-125
    • /
    • 2003
  • A way to measure the second parameter $A_2$of CT specimens is described. The displacement $\delta$$_{5}$ which is measured continuously from visual images of the lateral surface during crack growth is used to calculate the A, as a function of crack growth. The crack length is measured by DCPD(Direct Current Potential Drop) method and the J-resistance curve is determined according to ASTM standard E1737-96. To prove the validity of this method, three dimensional finite element analyses were performed, and variations of the displacements $\delta$$_{5}$ and $A_2$along the thickness were explored. As the result, it has been shown that the $\delta$$_{5}$ measured from the visual images of the lateral surface and the corresponding $A_2$can be regarded as the average through the thickness for 1T and 1/2T specimens of SA106Gr.C steel.steel.

An Experimental Method for Measuring Q (Q의 실험적 측정법)

  • Kim, Dong-Hak;Lee, Jeong-Hyun;Kang, Ki-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.9
    • /
    • pp.1607-1613
    • /
    • 2003
  • An experimental method to measure Q-parameter in-situ is described. The basic idea comes from the fact that the side necking near a crack tip indicates the loss of stress triaxiality, which can be scaled by Q. From the out-of-plane displacement and the in-plane strain near the surface of side necking, stress field averaged through the thickness is calculated and then Q is determined from the difference between the stress field and the HRR field corresponding to the identical J-integral. To prove the validity, three-dimensional finite element analysis has been performed for a CT configuration with side-groove. Q-value which was calculated directly from the near-tip stress field is compared with that determined by simulating the experimental procedure according to the proposed method, that is, the Q-value determined from the lateral displacement and the in-plane strain. In addition, the effect of location where the displacement and strain are measured is explored.

A Study on Development of 3D Analysis Tool for Estimation of Body Segment Parameter (인체분절계수 추정을 위한 CT 영상기반 3D 분석도구 개발에 관한 연구)

  • Park, Seong Bin;Chung, Kyung-Ryul;Choi, Chunho;Kim, sa-yup
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2011.05a
    • /
    • pp.325-326
    • /
    • 2011
  • 인체의 질량분포, 부피, 무게중심 등은 운동역학적 변인들을 분석하기위한 중요한 파라미터로 활용된다. 본 연구는 이러한 파라미터, 즉 인체분절계수를 추정하기 위한 분석도구의 개발에 관한 연구이다. 분석은 CT촬영을 통해 얻어진 2차원 의료영상데이터에 대해, 영상정보를 읽어 watershed 알고리즘을 통해 체성분에 따라 지방조직, 뼈조직, 근육조직에 따른 영역경계를 반 자동으로 구분할 수 있다. 분절계수의 추정은 최종적으로 확보한 영상에 대해, 분절경계면을 구분하여 이에 따른 질량, 부피 및 무게중심에 대한 비율을 계산하고 결과는 CSV 타입으로 저장한다. 개발된 분석도구는 연구목적에 따라 다양하게 분절화가 가능할 뿐만 아니라 영상데이터의 확보를 통해 인체분절계수 데이터베이스의 확장 구축에 기여할 수 있다.

  • PDF

Effects of Taurine Supplementation on Performance, Egg Quality, Blood Parameter and Liver Lipid and Lipid Peroxidation Levels of Laying Hens Fed High Fat Diet (고지방 사료에 타우린 첨가가 산란계의 생산성, 계란 품질, 혈액 성상, 간 조직의 지질 및 지질과산화물 수준에 미치는 영향)

  • Shim, Kwan-Seob;Park, Garng-Hee;Na, Chong-Sam;Ji, Joong-Ryong;Choe, Ho-Sung
    • Korean Journal of Poultry Science
    • /
    • v.37 no.4
    • /
    • pp.337-345
    • /
    • 2010
  • The current study was conducted to estimate the effect of dietary taurine on performance, egg quality, blood parameter, liver lipids and lipid peroxidation level of laying hens fed high fat diet. Two hundred eighty laying hens, forty five weeks of age, were allocated to four treatment groups with seven replicates of 10 each per treatment for 4 weeks. Experimental diets were assigned to each of the four groups: control diet (CON), CON with 0.5% taurine (CT), CON with 5% soybean oil (HF), and CON with 5% soybean oil and 0.5% taurine (HFT). Egg weight was significantly lower in the control than the CT (P<0.05). However, the HFT was similar to the level compared to both control and HF. Serum concentrations of total cholesterol, triglyceride and glutamic oxaloacetic transaminase (GOT) were significantly decreased by about 30%, 36% and 20%, respectively in the HFT compared to the HF (P<0.05). In the liver tissue, triglyceride concentration tended to be lower by about 28% in the HFT compared to the HF (P<0.05). The hepatic lipid peroxidation level was significantly decreased by about 25% in the HFT compared to the HF (P<0.05). These results indicated that taurine supplementation improved the serum total cholesterol, triglyceride concentration, and decreased hepatic lipid peroxidation level without affecting performance in laying hens fed high fat diet.