• Title/Summary/Keyword: Csl(TI)

Search Result 6, Processing Time 0.018 seconds

Monte Carlo Studies on an Amorphous Silicon (a-Si:H) Digital X-Ray Imaging Device (무정형 실리콘(a-Si : H) 디지털 X-선 영상기기의 개발을 위한 Monte Carlo 컴퓨터 모의실험연구)

  • 이형구;신경섭
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.225-232
    • /
    • 1998
  • Results of Monte Carlo simulations on amorphous silicon based x-ray imaging arrays are described. In order to investigate the characteristics of amorphous silicon x-ray imaging devices and to provide the optimum design parameter, Monte Carlo simulations were performed. Monte Carlo simulation codes for our purpose were developed and various combinations of x-ray peak voltages, aluminum filter thicknesses, CsI(TI) thicknesses, and amorphous silicon photodiode pixel sizes were tested in connection with detection efficiency and spatial resolution of the amorphous silicon based x-ray imager. With usual Csl(TI) thickness of 300${\mu}{\textrm}{m}$-500${\mu}{\textrm}{m}$, detection efficiency was in the range of 70%-95% and energy absorption efficiency was in the range of 40%-70% for 60kVp-120kVp x-ray. From the simulations it was found that amorphous silicon pixel size and Csl(TI) thickness were the most important parameters which determine the resolution of the imager. By use of our simulation results we could provide proper combinations of Csl(TI) thicknesses and pixels sizes for optimum sensitivity and resolution.

  • PDF

Effect of Silicon on Intergranular Corrosion Resistance of Ti-stabilized 11 wt% Cr Ferritic Stainless Steels (11 wt% 크롬이 함유된 Ti 첨가 페라이트스테인리스강의 입계부식에 미치는 규소의 영향)

  • Hyun, Youngmin;Kim, Heesan
    • Corrosion Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.265-273
    • /
    • 2013
  • Ti-stabilized 11 wt% Cr ferritic stainless steels (FSSs) for automotive exhaust systems have been experienced intergranular corrosion (IC) in some heat-affected zone (HAZ). The effects of sensitizing heat-treatment and silicon on IC were studied. Time-Temperature-Sensitization (TTS) curves showed that sensitization to IC was observed at the steels heat-treated at the temperature lower than $650^{\circ}C$ and that silicon improved IC resistance. The sensitization was explained by chromium depletion theory, where chromium is depleted by precipitation of chromium carbide during sensitizing heat-treatment. It was confirmed with the results from the analysis of precipitates as well as the thermodynamical prediction of stable phases. In addition, the role of silicon on IC was explained with the stabilization of grain boundary. In other words, silicon promoted the formation of the grain boundaries with low energy where precipitation was suppressed and consequently, the formation of Cr-depleted zone was retarded. The effect of silicon on the formation of grain boundaries with low energy was proved by the analysis of coincidence site lattice (CSL) grain boundary, which is a typical grain boundary with low energy.

Effects of Scintillation Crystal Surface Treatments on Small Gamma Camera Imaging (섬광체 옆 표면처리가 소형 감마카메라 영상에 미치는 효과)

  • Kim, J. H.;Choi, Y.;Kim, J. Y.;Oh, C. H.;Kim, S. E.;Choe, Y. S.;Lee, K. H.;Joo, K. S.;Kim, B. T.
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.6
    • /
    • pp.515-521
    • /
    • 1999
  • Scintillator crystal is an important part and detcrmines performance characteristics of the gamma camera. We investigated the offects of scintillation crystal surface treatment on gamma camera imaging. Nal(TI) and Csl(Tl) scintillators. 20 mm diameter and 10 mm thickness, applied with two different surface treatments, white and black reflcetors, were applied to Nal(Tl) and Csl(Ti). The optical properties of generated scintillation light were evaluated by Monte Carlo simulation method and by actual measurement using a position sensitive photomultiplier tube (PSPMT). We measured sensitivity, energy resolution and spatial resolution of gamma camera with the various scintillators coupled to a PSPMT. In the simulation. Nal(Tl)-white prosented the best sensitivity. In the measurements, the sensitivities and the intrinsic spatial resolutions of Nal(Tl)-white, Nal(Tl)-black. CsI(Tl)-white, CsI(Tl)-black were 2920, 2322, 1754, 1401 cps/$\mu$ci and 5.2, 4.5, 7.0, 6.3 mm FWHM. respectively. Their intrinsic energy resolutions were mesured 12.5, 23.5, 20.5, 33.3% FWHM at 140 keV Tc-99m. In this study, we investigated the offects of a side surface treatment of the scintillator on the gamma camera imaging. Simulation and measurement prescnted similat trends. Based on the results, we concluded that the surface of th NaI(Tl)seintillator must be treated by absorptive materials in order to develop the gamma camera having good spatial resolution.

  • PDF

Micro-CT System for Small Animal Imaging (소동물영상을 위한 마이크로 컴퓨터단층촬영장치)

  • Nam, Ki-Yong;Kim, Kyong-Woo;Kim, Jae-Hee;Son, Hyun-Hwa;Ryu, Jeong-Hyun;Kang, Seoung-Hoon;Chon, Kwon-Su;Park, Seong-Hoon;Yoon, Kwon-Ha
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.102-112
    • /
    • 2008
  • We developed a high-resolution micro-CT system based on rotational gantry and flat-panel detector for live mouse imaging. This system is composed primarily of an x-ray source with micro-focal spot size, a CMOS (complementary metal oxide semiconductor) flat panel detector coupled with Csl (TI) (thallium-doped cesium iodide) scintillator, a linearly moving couch, a rotational gantry coupled with positioning encoder, and a parallel processing system for image data. This system was designed to be of the gantry-rotation type which has several advantages in obtaining CT images of live mice, namely, the relative ease of minimizing the motion artifact of the mice and the capability of administering respiratory anesthesia during scanning. We evaluated the spatial resolution, image contrast, and uniformity of the CT system using CT phantoms. As the results, the spatial resolution of the system was approximately the 11.3 cycles/mm at 10% of the MTF curve, and the radiation dose to the mice was 81.5 mGy. The minimal resolving contrast was found to be less than 46 CT numbers on low-contrast phantom imaging test. We found that the image non-uniformity was approximately 70 CT numbers at a voxel size of ${\sim}55{\times}55{\times}X100\;{\mu}^3$. We present the image test results of the skull and lung, and body of the live mice.

  • PDF

The Comparative Study of Effect on Speech before and after Orthognathic Surgery of Patients (악교정 환자의 악교정 수술전후 발음양상에 대한 비교연구)

  • Kwon, Kyung-Hwan;Kim, Soo-Nam;Lee, Dong-Keun;Cho, Yong-Min;Lee, Suk-Hyang
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.2
    • /
    • pp.191-205
    • /
    • 2000
  • The purpose of this study was undertaken to determine the effects of orthognathic surgery on speech. The hyposis stated herein is that functional behaviors of the dentofacial complex, such as speech production, may be adversely affected by deviations of a structural nature(especially, Class III malocclusion). Twenty adults with Class III malocclusion(13 female and 7 male) were studied preoperative, immediate postoperative and either 6 or 12 months postoperative lateral cephalograms. They had mandibular prognathism and had undergone mandible setback operation. The position of tongue, soft palate(Uvula), hyoid bone, respiratory track width, and pharyngeal depth were assessed on lateral cephalograms with 23 cephalometric variables, ANOVA, Paired t-tests and Pearson's product-moment correlation coefficient tests were used to evalute the operative changes in all cephalometric parameters. A experienced speech and language pathologists performed narrow phonetic transcriptions of tape-recorded words and sentences produced by each of the ninth patients and the recording tapes were analyzed by phonetic computer program(Computerized Speech Lab(CSL) Model 4300BI(U.S.A.)) These judges also recorded their ratings of each patient's overall consonants, hypernasality, hyponasality, and articulation proficiency. The results obtained are as follows; 1. There were significant changes in distance of posterior pharyngeal wall to tongue (TI-TW2, TS-TW3) after the surgery at 6 months postoperatively(each p<0.01 p<0.05). 2. The posterior tongue point(TI, TS, PPT) moved posteriorly after surgery and remained to its changed position at 6 months postoperatively(p<0.05). The displacement of tongue was correlated with the movement of mandibular setback amount(p<0.05). The hyoid bone moved posteriorly superiorly after immediate postoperative period. There was significant changes in hyoid bone movement after immediated postoperative period(p<0.05), but returned to its original position during the follow-up period(p>0.05) 3. The soft palate was displaced posteriorly superiorly after immediated operative period and remained to its changed position at 6 months postoperatively(p<0.05). ANS-PNS-SPT angle increasing, PPU-PPPo distance narrowing was showed after surgery, and remained its appearance 6 months postoperatively(p<0.05). 4. There were significant changes in formant value and squre diagram of vowel sound after the orthognathic surgery and the follow-up period. There were significant changes in /ㅅ/sound and posterior tongue sound. 5. The posterior movement of tongue and the posteriosuperior movement of soft palate was correlated with mandibular setback amount after orthognathic surgery. On the vowel squre diagram, the author found that the place of articulation after operation moved downward, backward, upward. 6. In assessing speech abnormalities, dental occlusion should be considered as a contributing factor. The vast majority of subjects with preoperative misarticulations eliminated or reduced their errors following orthognathic surgery. There was significant difference in speech impovement between pre- and postoperation.

  • PDF

An Iterative Method for Flat-Field Correction of Digital Radiography When Detector is at Any Position (반복적인 방법을 이용한 임의의 DR detector 위치에서의 flat field correction 방법 연구)

  • Kim, Do-Il;Lee, Hyoung-Koo;Kim, Sung-Hyeon;Park, Dae-Sop;Choe, Bo-Young;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.64-66
    • /
    • 2004
  • When examing patients with DRs it is necessary to remove bad pixels and lines and to correct non-uniform offsets and x-ray field. For non-uniformity correction a flat field x-ray image is needed, and to obtain it the center of detector is usually aligned with the focal spot of the x-ray tube, which is conserved when examing patients to preserve the flat field. In some of radiographic techniques, however, it is necessary to move the x-ray tube off the center position of detector or tilt the detector. We investigated the effect of detector tilting on the non-uniformity correction, and propose a method to reduce the effect using a new algorithm. The flat field of X-ray in the DR detector could be guaranteed with this result.

  • PDF