• Title/Summary/Keyword: Cryochamber

Search Result 8, Processing Time 0.023 seconds

Thermal Analysis of a Cryochamber for an Infrared Detector Considering a Radiation Shield (적외선 검출기용 극저온 챔버에서 복사 차폐막을 고려한 열해석)

  • Kim Young-Min;Kang Byung-Ha
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.8
    • /
    • pp.672-677
    • /
    • 2006
  • The steady cooling characteristics of a cryochamber for infrared (IR) detector have been investigated analytically, considering radiation shields. The thermal modeling considers the conduction heat transfer through cold finger, the gaseous conduction due to out-gassing, and the radiation heat transfer. The cooling load of the cryochamber is obtained by using a fin equation. The results obtained indicate that the gaseous conduction plays an important role in determining the steady cooling load. The steady cooling load is increased as the gas pressure is increased. It is also found that the cooling load is substantially decreased with a radiation shield. The most thermal load of a cryochamber occurs through the cold finger.

An Experimental Study on the Effects of a Radiation Shield on the Thermal Load of a Cryochamber (복사 차폐막이 극저온 용기의 부하에 미치는 영향에 관한 실험적 연극)

  • Kim, Young-Min;Park, Seong-Je;Kang, Byung-Ha
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.365-370
    • /
    • 2005
  • Infrared (lR) detectors are widely used for such applications as thermoelstic stress analysis, medical diagnostics and temperature measurement. Infrared detectors commonly need to be refrigerated below 80 K, and thus a cooling system should be equipped together with the detector system. The cooling load, which should be removed by the cooling system to maintain the nominal operating temperature of the detector, critically depends on the insulation efficiency of the cryochamber housing the detector. Cryochamber considers the conduction heat transfer through a cold finger, the gases conduction and radiation heat transfer. The thermal loads of an infrared detector Cryochamber with radiation shield are investigated experimentally in present study. Since the effect of radiation heat transfer on thermal loads is significant, radiation shields is installed in the cold finger part to protect heat input through radiation. It is found that the thermal load can be substantially reduced by increasing the number of radiation shield.

  • PDF

An Experimental Study on the Thermal Load of a Cryochamber with Radiation Shields (복사 차폐막이 설치된 극저온 용기의 열부하 특성에 관한 실험적 연구)

  • Kim, Young-Min;Kang, Byung-Ha;Park, Seong-Je
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.1
    • /
    • pp.11-16
    • /
    • 2008
  • Infrared (IR) detectors are widely used for such applications as thermoelastic stress analysis, medical diagnostics and temperature measurement. Infrared detectors commonly need to be refrigerated below 80 K, and thus a cooling system should be equipped together with the detector system. The cooling load, which should be removed by the cooling system to maintain the nominal operating temperature of the detector, critically depends on the insulation efficiency of the cryochamber housing the detector. Thermal load of a cryochamber is attributed to the conduction heat transfer through a cold finger, the gases conduction and radiation heat transfer. The thermal loads of an infrared detector cryochamber with a radiation shield are investigated experimentally in present study. Since the effect of radiation heat transfer on thermal loads is significant, radiation shields is installed in the cold finger part to protect heat input through radiation.

An Experimental Study on the Cooling Characteristics of an Infrared Detector Cryochamber (적외선 센서용 극저온 용기의 냉각특성에 관한 실험적 연구)

  • Kang Byung Ha;Lee Jung Hoon;Kim Ho-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.889-894
    • /
    • 2004
  • Infrared (IR) detectors are widely used for many applications, such as temperature measurement, intruder and fire detection, robotics and industrial equipment, thermoelstic stress analysis, medical diagnostics, and chemical analysis. Quantum detectors commonly need to be refrigerated below 80 K, and thus a cooling system should be equipped together with the detector system. The cooling load, which should be removed by the cooling system to maintain the nominal operating temperature of the detector, critically depends on the insulation efficiency of the cryochamber housing the detector. Thermal analysis of cryochamber includes the conduction heat transfer through a cold well, the gases conduction and gas outgassing, as well as radiation heat transfer, The transient cooling characteristics of an infrared detector cryochamber are investigated experimentally in the present study. The transient cooling load increases as the gas pressure is increased. Gas pressure becomes significant as the cooling process proceeds. Cool down time is also increased as the gas pressure is increased. It is also found that natural convection effects on cool down time become significant when the gas pressure is increased.

Friction of Superconductor Bearing (초전도 베어링의 마찰계수 측정)

  • ;J. R Hull
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.237-239
    • /
    • 2003
  • A high-temperature superconductor (HTS) journal bearing was studied for loss. Two HTS bearings support the rotor at top and bottom. The rotor weight is 4 kg and the length is about 300 mm. Both the top and bottom bearings have two permanent magnet (PM) rings with an iron pole piece separating them. Each HTS journal bearing is composed of six pieces of superconductor blocks of size 35$\times$25$\times$10 mm. The HTS blocks are encased in a cryochamber through which liquid nitrogen flows. The inner spool of the cryochamber is made from G-10 to reduce eddy current loss, and the rest of the cryochamber is stainless steel. The magnetic field from the PM rings < 10 mT on the stainless part. The rotational drag was measured over the same speed range. Results indicate that the 10 mT design criteria for magnetic field on the stainless part of the cryochamber is too high.

  • PDF

Numerical Analysis on the Transient Cooling Characteristics of an Infrared Detector Cryochamber (적외선 센서 냉각용 극저온 용기의 과도 냉각 특성에 관한 수치해석)

  • 이정훈;김호영;강병하
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.2
    • /
    • pp.68-72
    • /
    • 2002
  • This work investigates the transient cooling characteristics of an Infrared (IR) detector cryochamber, which has a critical effect on the cooling load. The current thermal modeling considers the conduction heat transfer through a cold well. the gaseous conduction due to outgassing. and the radiation heat transfer. The transient cooling Performance. i.e. the penetration depth and cooling load, is determined using a finite difference method. It is found that the penetration depth increases as the bore conductivity increases. Gaseous conduction and radiation hardly affect the penetration depth. The transient cooling load increases as the bore conductivity increases. The effects of gaseous conduction and radiation on transient heat transfer are weak at initial stages of cooling. However, their effects become significant as the cooling Process Proceeds.