• Title/Summary/Keyword: Crush strength

Search Result 59, Processing Time 0.021 seconds

An Experimental Study on the Properties of Fresh and Hardened Ready Mixed Concrete Using EEZ sand and Crush sand (EEZ모래와 부순모래를 사용한 레미콘의 굳지않은 성상 및 경화성상에 관한 연구)

  • Shin Seung-Bong;Koo Kyung-Mo;Na Chul-Sung;Ryu Jae-Chul;Kim Gyu-Yong;Kim Moo-Han
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.05a
    • /
    • pp.53-56
    • /
    • 2006
  • Recently, trouble of sand supplying is occurred according to exhaustion of natural sand resources. Therefore various measures are proposed for solution of trouble of sand supply and crushed sand among measures is used as one of most universal measures. But because crushed sand have poor particle shape and plenty of makes micro particle, the quality of concrete using crushed sand deteriorated. Therefore, this study evaluated engineering property of concrete with replacement ratio of crushed sand and EEZ sand and applied evaluation result to fundamental data for quality control of concrete using crushed sand and EEZ sand. The result of this study have shown that quality of concrete using crushed sand and EEZ sand and The compressive strength of concrete up to 50, 70% EEZ sand replacement by crush sand, nearly equal to that of general sand.

  • PDF

A Study of the usage of Corrugated Fiberboard Cartons for Domestic Fresh Produce and Their Physical Properties: Focused on a Gyeongsan City, North Gyeongsan Province (국내 신선 농산물 포장용 골판지 상자의 이용 실태 및 물리적 특성 연구: 경북 경산 소재 지역 중심으로)

  • Kim, Minhwi;Lee, Myungho;Boonsiriwit, Athip;Lee, Youn Suk
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.1
    • /
    • pp.55-66
    • /
    • 2022
  • In this study, forty corrugated fiberboard (CF) boxes for fresh produce were collected from farms located in Gyeongsan city and evaluated its characterizations and physical properties according to Korean Standard (KS). The basis weight, flute, and paperboard combination were determined for the characterizations of CF boxes. The measured basis weights of all samples were within the tolerance limit referred to KS and the flutes were B/F, EB/F, and AB/F flute, respectively. The bursting strength (BS), edgewise crush resistance (ECR), and compression strength (CS) were tested to evaluate the physical properties. There are four single-walled (SW) CF boxes showed BS and ECR higher than 638 kPa and 3.30 kN/m, respectively. One SW CF boxes showed BS and ECR higher than 785 kPa and 3.43 kN/m, respectively. In case of double-walled (DW) CF boxes, sixteen CF boxes showed BS and ECR higher than 785 kPa, 4.96 kN/m (AB flute), or 4.90 (EB flute), respectively. The other nineteen CF boxes showed BS and ECR higher than 981 kPa, 5.29 kN/m (AB flute), or 5.20 (EB flute), respectively. All the CF boxes except two samples showed the acceptable compression strength in reference to the guideline of KS.

Energy Absorption Characteristics and Optimal Welding Space of Square Hat Type Thin-walled Tube (정사각 모자형 박판튜브의 에너지흡수특성 및 최적 용접간격)

  • Lee, Hyung-Yil;Kim, Bum-Joon;Han, Byoung-Kee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.12
    • /
    • pp.2703-2714
    • /
    • 2002
  • In this work, energy absorption characteristics and optimal welding space of spot-welded square hat type tube are investigated via quasi-static crush experiments and finite element (FE) analyses. A FE model reflecting the crush characteristics is established based on the experimentally observed crush mechanisms of specimens with welding spaces (20, 30 & 45 mm) and (25,40 & 55 mm) respectively for two specimen widths (60, 75 mm). The established FE model is then applied to other crush models of widths (50, 60 & 75 mm) with various welding spaces (20, 25, 30, 40, 45, 55, 75, 150, 300 mm) respectively. We examine the energy absorption characteristics with respect to the welding space for each specimen width. The outcome suggests an optimal spot welding space of square hat type thin-walled tube. Energy absorption is also presented in terms of yield strength of base metal, specimen thickness, width, and mean crushing force of spot-welded square hat type thin-walled tube.

Improvement of Multiply Board Properties with Starch Spraying (전분 분무기술을 통한 다층지의 물성개선)

  • Lee, Hak-Lae;Ryu, Jeong-Yong
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.39 no.3
    • /
    • pp.12-23
    • /
    • 2007
  • Frequently spraying of natural starch slurry onto the formed wet web has been adopted to improve properties of paperboards. This conventional starch spraying technique, however, becomes less effective in strength improvement. In this study the effects of various factors including wet web dryness, quantity of starch slurry sprayed, and drying temperature on paperboard properties were investigated. Migration of starch granules into the webs appeared to cause a reduction in plybond strength when the web dryness was lower than this level. Wet webs should contain enough water to swell the starch granules, and at the same time they should be heated to a temperature high enough for complete cooking of the sprayed starches to occur. This suggested that preheating of the wet web can be employed to improve the plybond strength.

Compression Strength Design Program of Boxes for Agricultural Products Packaging (농산물 포장상자의 압축강도설계 프로그램)

  • Park, Jong-Min;Kim, Man-Su;Kim, Tae-Uk
    • Food Science and Preservation
    • /
    • v.3 no.2
    • /
    • pp.195-202
    • /
    • 1996
  • The compression strength of the corrugated fiberboard boxes is very important information to the manufacturers and the end users. The computer program being used to design the compression strength of the boxes was developed by using Korean Standards for the corrugated fiberboard box and some other data. The developed computer program could be applied to only the boxes produced according to the Korean Standards. Also this program needs to be revised continuously by the newly added and developed data.

  • PDF

Improvement of Bonding Strength and Water Resistance of Corrugated Board (전분 접착제의 접착 효율 및 골판지의 내수성 향상을 위한 첨가제의 적용)

  • Jang, Dong-Wook;Park, Jong-Moon
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.48 no.1
    • /
    • pp.61-66
    • /
    • 2016
  • In order to improve the bonding efficiency of starch adhesives and water resistance of corrugated board, mixing ratio of additives dosage was changed and its effects were analyzed. When the additives dosage was increased, bonding strength, vertical compression strength, bursting strength and water resistance were increased, because of hydroxyl groups or acetyl groups in starch adhesives and cellulose fibers of corrugated board were cross-linked by additives. When 1.0% glyoxal dosage was added, flat crush strength and vertical compression strength were increased. With 1.5% glyoxal, bonding strength and bursting strength were increased. However, 2.0% glyoxal dosage was added, most of strength except bursting strength were decreased. Thus, when the appropriate amount of additives are added during corrugated board production process, increased bonding efficiency of starch adhesives and higher water resistance of corrugated board can be achieved.

Compressive Strength Reduction Characteristics of Linerboard as Influenced by Temperature and Humidity (온도 및 습도 변화에 따른 라이너원지의 압축강도 열화에 관한 연구)

  • 이준호;김수일;하영선
    • Food Science and Preservation
    • /
    • v.6 no.3
    • /
    • pp.303-307
    • /
    • 1999
  • Compressive strength reduction characteristics of 4 different linerboards(SC, KA, SK and IK) as influenced by temperature and humidity were investigated by ring crush test. No significant effect of temperature on the reduction of compressive strength was found for samples prepared at 5$^{\circ}C$ and 30$^{\circ}C$. At the relative humidity of 66 percents, IK linerboard showed the lowest reduction of the compressive strength. At the relative humidity of 93 percents, KA linerboard lost 40 percents of its initial compressive strength while SK linerboard lost its strength up to 56 percents. The result indicated that KA linerboard was the most cost effective and material with the highest compressive strength among tested linerboards.

  • PDF

The Effects of Horizontal Vibration on the early Age Concrete under Kinds of Fine Aggregate (수평진동이 잔골재의 종류에 따른 초기재령 콘크리트에 미치는 영향)

  • 정병훈;김이훈;장희석;김종수;김명식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.623-628
    • /
    • 2001
  • The objective of this study is to find out the effect of Horizontal vibration on the compressive strength for 7 days and 28 days cured concrete specimens according to the kind of fine aggregates and the variation of vibration velocities, and times began to vibrate. Three kinds of fine aggregate(river sand, sea sand, crush sand), three types of vibration velocities(0.25, 0.5 0.1kine(cm/sec)), and four steps of times(0, 3, 6, 9 hours after concrete casting) were chosen as the experimental parameters in this study, the vibrations are applied for 30 minutes in each case. From this study, the variation with type of fine aggregate doesn't show tendency and the compressive strength decreases with increasing vibration velocity. When the vibration force time is more than 6 hour, It shows that compressive strength decreases under the condition of vibration velocity which the value is 0.5 kine and 1 kine, respectively.

  • PDF

집합체 SSE/LOCA해석을 위한 지지격자 충격시험

  • 전상윤;김용환;전경락;김재원
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05b
    • /
    • pp.703-708
    • /
    • 1995
  • 지진 및 냉각재상실사고와 같은 외력에 대한 집합체 구조적 건전성 분석을 위한 해석시 필요한 지지격자의 동적 특성치들을 얻기 위해 17$\times$17 JDFA 중간지지격자에 대한 충격시험을 수행하였으며, 지지격자에 대한 허용충격하중값(Crush Strength)을 구하고 Impact Duration Method를 이용하여 집합체 구조해석에 필요한 지지격자의 동적 강성도 (Dynamic Stiffness)를 구하였다.

  • PDF

Connection Structure Between Center Pillar and Roof Center Rail (거셋일체형 센터필러 어퍼 루프레일 연결구조 개발)

  • Lee, Hae Hoon;Chung, Pil Sang;Kang, Chong Ku
    • Journal of Auto-vehicle Safety Association
    • /
    • v.13 no.4
    • /
    • pp.26-32
    • /
    • 2021
  • This study is intended to augment the Roof strength test being evaluated by IIHS (Insurance Institute for Highway Safety). In order to find solutions for increasing Roof Crashworthiness Evaluation SWR (Strengthto-weight ratio). This study introduces that Integrated Connection Structure Between Center Pillar and Roof Center Rail is proposed as a critical solution.