• Title/Summary/Keyword: Crown retention

Search Result 77, Processing Time 0.03 seconds

Case report: Application of Implant Supported Removable Partial Denture due to Multiple Dental Implant Loss of the Fixed Implant Supported Prosthesis (다수의 임플란트발거로 임플란트 고정성 보철이 실패한 환자에서의 잔존 임플란트를 이용한 부분 가철성 국소의치 수복증례)

  • Kang, Jeong Kyung;Nam, Gi Hoon
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.23 no.1
    • /
    • pp.34-40
    • /
    • 2014
  • There are several treatment options for rehabilitation of partial edentulism including the use of conventional or implant-retained fixed prostheses. However, such prosthetic options cannot always be possible because of compromised general and oral health (i.e. loss of supporting tissues, medical reasons, extensive surgical protocol and osseointegration failure of dental implant) as well as the affordability of patients. In some cases, removable partial denture provides easier access for oral hygiene procedures and the ability to correct discrepancies in dental arch relationships than implant fixed prosthesis. Recently, Implant Supported Removable Partial Denture (ISRPD) where to place dental implant in strategic position has been suggested to improve the limitation and shortcomings of conventional RPD. ISPRD can overcome mechanical limition of conventional RPD by placing implant in a favorable position and can be cost-effective, prosthetic solution for partially edentulous patients who are not immediate candidates for extensive, fixed implant supported restorations. Incorporation of dental implants to improve the RPD support and retention and to enhance patient acceptance should be considered when treatment planning for RPD. In this case, 59 years old male patient who received dental treatment of implant fixed prosthesis on both side of the upper jaw and implant overdenture on lower jaw showed implant abutment screw fracture on #15i and osseointegration failure on multiple number of implants. After removing failed implants, we planned ISRPD using #15i,24i,25i,26i and #23 natural tooth for RPD abutment. We fabricated #23 surveyed crown,#24i=25i=26i surveyed bridge and #15i gold coping for support,retention and stability for RPD. Periodic follow up check for 2years has been performed since the ISRPD delivery to the patient. No sign of screw loosening, fracture or bone resorption around abutment implants were detected.

Clinical Convergence Angle of Prepared Tooth for full Veneer Crowns (전부 피개관의 치아 형성 시 축면 경사각에 대한 조사)

  • Kim, Sung-Jin;Pae, Ah-Ran;Woo, Yi-Hyung;Kim, Hyeong-Seob
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.1
    • /
    • pp.21-32
    • /
    • 2010
  • The convergence angle of a prepared tooth is a very important factor in the retention and resistance of a crown restoration. But various intraoral environments and clinician's techniques make it difficult to obtain the ideal inclination. Therefore, in this study, clinical convergence angle of a prepared tooth was investigated. The data was collected from the patient models of prosthodontic residents and the patient models of general practitioners. The images of mesiodistal and buccolingual surfaces were taken with a digital camera to evaluate the convergence angle on 'ImageJ' program. The images were classified according to the criteria (1. Clinician group, 2. Position in the dental arch, 3. The purpose of abutment preparation)and then analyzed. The mean convergence angle of a prepared tooth for Korean clinicians was $15.02^{\circ}$ (${\pm}10.13^{\circ}$). 1. It was significant in the convergence angle between the general practitioner group and the prosthodontic resident group(p<0.05). 2. It was significant between the mesiodistal and buccolingual surface in the the prosthodontic resident group(p<0.05). 3. For the general practitioner group, it was significant when anteriors and premolars were compared with molars(p<0.05). For the prosthodontic resident group, it was significant when anteriors and premolars were compared with molars (p<0.05). 4. When divided into upper and lower arches, for the general practitioner group, it showed significant difference in the buccolingual aspect(p<0.05). Also in the prosthodontic resident group, it showed significant difference in the buccolingual aspect(p<0.05). 5. Dividing left and right sides of the arches, there was no significant difference in the general practitioner group and the prosthodontic resident group(p>0.05). 6. In the general practitioner group, it was significant in the mesiodistal axial convergence angle of single crown abutment and 3 unit bridge abutment(p<0.05). In the prosthodontic resident group, it was significant in the mesiodistal and overall axial convergence angle of single crown abutment and 3 unit bridge abutment(p<0.05). Clinical convergence angle of prepared tooth in Korea was included in agreement with other studies investigating convergence angle that ranged from 10 to 22 degrees, achieved in clinical practice.

The prosthetic approach and principle for an collapsed VDO ; A clinical case of pseudo Class III patient (저위교합환자의 보철적 접근법과 이론 : Pseudo Class III 교합환자 증례)

  • Kwon, Kung-Rock;Choi, Dae-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.20 no.2
    • /
    • pp.121-134
    • /
    • 2004
  • This article describes a clinical protocol for the conventional rehabilitation of patient diagnosed with partial anodontia. A combined dental therapy approach was used and included endodontic therapy and root capping on the maxillary central incisors, fabrication of a maxillary overdenture, and fabrication of mandibular konus overdenture supported by 3 konus abutments. Within this protocol, tooth-supported overdenture prostheses are used for 2 purposes: first, to obtain the most rigid retention and function at an established maxillary-mandibular relationship; and second, to continuously maintain function and esthetic appearance applying immediate dentures after teeth extraction. The idea behind this protocol and its associated clinical procedures is presented along with a discussion compared with implant therapy. In the case introduced, and after 7 years of observation, the therapy can be seen as a success. We increased the occlusal vertical height in this case, but it would be more appropriate to see this as recovering the occlusal vertical height that was lost. The process of increasing the occlusal vertical height, that is restoration of the face, modification of the extrinsic occlusion of the incisors, and retraction of the mandible is very difficult and important. Ultimately, class III malocclusion is fixed, adequate occlusal vertical height is gained, and the retracted posterior anodontial portion is restored by prosthodontic dentures based on the rigid support theory. The result of the therapy done on the later-achieved malocclusion with partial anodontia on the posterior portion must consider the following in order to maintain the safety of the esthetics of the tooth and face for a period of time: 1) occlusal restoration with an ideal occlusal vertical height, 2) allowance of the final occlusion induced by the functional relationship of the upper and lower jaw, 3)final occlusion functionally induced by the lip competence limit.

Finite Element Stress Analysis of Implant Prosthesis of Internal Connection System According to Position and Direction of Load (임플랜트-지대주의 내측연결 시스템에서 하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소 응력분석)

  • Jang, Jong-Seok;Jeong, Yong-Tae;Chung, Chae-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.1
    • /
    • pp.1-14
    • /
    • 2005
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis of internal connection system(ITI system) according to position and direction of load, under vertical and inclined loading using finite element analysis (FEA). The finite element model of a synOcta implant and a solid abutment with $8^{\circ}$ internal conical joint used by the ITI implant was constructed. The gold crown for mandibular first molar was made on solid abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric cusp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant under both vertical and oblique loading but stresses in the cancellous bone were low under both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. So, the relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 4. In this internal conical joint, vertical and oblique loads were resisted mainly by the implant-abutment joint at the screw level and by the implant collar. Conclusively, It seems to be more important that how long the distance is from center of rotation of the implant itself to the resultant line of force from occlusal contact (leverage). In a morse taper implant, vertical and oblique loads are resisted mainly by the implant-abutment joint at the screw level and by the implant collar. This type of implant-abutment connection can also distribute forces deeper within the implant and shield the retention screw from excessive loading. Lateral forces are transmitted directly to the walls of the implant and the implant abutment mating bevels, providing greater resistance to interface opening.

ECTOPIC ERUPT10N OF TRANSPOSED MANDIBULAR PERMANENT LATERAL INCISOR (이소 맹출한 하악 측절치의 교정적 치험례)

  • Lim, Hyun-Hwa;Kim, Yong-Soo;Jang, Ki-Taek;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.3
    • /
    • pp.438-443
    • /
    • 2000
  • Ectopic eruption should be understood as a change in the course of the normal eruption path of a dental bud at any moment its origin. An example of this alteration is the dental transposition, a rare and more specific dental anomaly that may be defined as a change of position between two teeth. This case shows ectopic eruption of transposed mandibular lateral incisor beneath primary first molar at the first transitional period of the mixed dentition The crown of the lateral incisor has tipped distally, compelling root resorption and exfoliation of the adjacent primary cuspid and primary first molar. The reason for such eruption is not clearly understood, but it may involve; (1)trauma history, (2)prolonged retention of the deciduous teeth, (3)premature exfoliation of the deciduous teeth, and (4)genetic factor. Treatment is divided into interceptive and definitive treatment. Ectopically erupting mandibular incisor tends to become transposed with the adjacent cuspid and thus seems to warrant early orthodontic intervention. Early treatment may obviate later extraction or transposition of the incisor and canine in the permanent dentition. Timing is an important factor to be considered regarding in the correction of the lateral incisor transposition. This case advocates treatment with an active orthodontic therapy at the early stage of the mixed dentiton, before the eruption of the permanent cuspid.

  • PDF

Restoration of IARPD in partially edentulous patients with bone defects due to osteomyelitis treatment (골수염 치료로 인해 골결함이 있는 부분무치악 환자에서 IARPD 수복)

  • Park, Se-Hyun;Sung, Han-Gyul;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.359-369
    • /
    • 2021
  • Implant prostheses and removable partial dentures are mainly used as treatment methods for partial edentulous patients who have lost a number of teeth. The implant-assisted removable partial denture (IARPD) is strategically selected. The defect in maxillofacial structure due to osteomyelitis, a type of facial bone infection, causes dysfunction such as mastication, swallowing, and pronunciation, as well as social and psychological effects, so a removable restoration is required to restore the supporting tissue. Design of abutment and partial dentures is an essential factor in the success of treatment. In this case, IARPD, which has superior retention and stability compared to traditional removable partial dentures, can have a good prognosis. In a partial edentulous patient with bone defects due to osteomyelitis treatment, the stability of the denture was secured with IARPD restoration. Moreover, maintenance problem that may occur in the future was minimized by providing an appropriate denture design and occlusal scheme through several provisional restorations. This case can be expected to have a favorable prognosis in the long term.

MICROLEAKAGE AND WATER STABILITY OF RESIN CEMENTS

  • Choi Sun-Young;Lee Sun-Hyung;Yang Jae-Ho;Han Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.369-378
    • /
    • 2003
  • Statement of Problem: Recently, resin cements have become more widely used and have been accepted as prominent luting cements. Current resin cements exhibit less microleakage than conventional luting cements. However, the constant contact with water and exposure to occlusal forces increase microleakage even in resin cements inevitably. Most bonding resins have been modified to contain a hydrophilic resin such as 2-hydroxyethylmethacrylate (HEMA) to overcome some of the problems associated with the hydrophobic nature of bonding resins. By virtue of these modifications, bonding resins absorb a significant amount of water, and there may also be significant stresses at bonding interfaces, which may adversely affect the longevity of restorations. Therefore the reinforcement of water stability of resin cement is indispensable in future study. Purpose: This study was conducted to examine the influence of water retention on microleakage of two resin cements over the period of 6 months. Materials and Methods: 32 extracted human teeth were used to test the microleakage of a single full veneer crown. Two resin cements with different components and adhesive properties - Panavia F (Kuraray Co., Osaka, Japan) and Super-Bond C&B (Sun Medical Co., Kyoto, Japan)- were investigated. The storage medium was the physiological saline solution changed every week for 1 month, 3 months, and 6 months. One group was tested after storage for 1 day. At the end of the each storage period, all specimens were exposed to thermocycling from $5^{\circ}C$ to $55^{\circ}C$ of 500 cycles and chewing simulation of 50,000 cycles, and then stained with 50% silver nitrate solution. The linear penetration of microleakage was measured using a stereoscopic microscope at ${\times}40$ magnification and a digital traveling micrometer with an accuracy of ${\pm}3{\mu}m$. Values were analyzed using two-way ANOVA test, Duncan's multiple range tests (DMRT). Results : Statistically significant difference of microleakage was shown in the 3-month group compared with the1-day or 1-month group in both systems (p<0.05) and there were statistically significant differences in microleakage between the 3-month group and the 6-month group in both systems (p<0.05). The two systems showed different tendency in the course of increased microleakage during 3 months. In Panavia F, microleakage increased slowly throughout the periods. In Super-Bond C&B, there was no significant increase of microleakage for 1 month, but there was statistically significant increase of microleakage for the next 2 months. For the mean microleakage for each period, in the 3-month group, microleakage of Super-Bond C&B was significantly greater than that of Panavia F. On the other hand, in the 6-month group, microleakage of Panavia F was significantly greater than that of Super-Bond C&B (p<0.05). Conclusion: Within the limitation of this study, water retention of two different bonding systems influence microleakage of resin cements. Further studies with the longer observation periods in viro are required in order to investigate water stability and the bonding durability of the resin cement. CLINICAL IMPLICATIONS Microleakage at the Cement-tooth interfaces did not necessarily result in the failure of the crowns. But it is considered to be a major factor influening the longerity of restorations. Further clinical approaches for decreasing the amount of microleakage are required.