• Title/Summary/Keyword: Crown dental

Search Result 879, Processing Time 0.029 seconds

EFFECTS OF DENTAL THERAPEUTIC AGENTS ON THE RESPONSE OF THE PULP NERVE (치과치료용 약물이 치수신경의 반응에 미치는 영향)

  • Kwon, Oh-Yang;Yoon, Soo-Han;Lee, Jong-Heun
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.1
    • /
    • pp.1-15
    • /
    • 1990
  • The aim of this study was to investigate the effect of dental therapeutic agent on conduction velocity and threshold current of intradental A- and C-fibers in the cat. Inferior alveolar nerve of cat anesthetized with sodium pentobarbital was exposed and dissected until response of functional single pulp nerve until could be evoked by monopolar electrical stimulation of the crown of the lower left canine teeth. 10ms rectangular pulse was used to determine the threshold current and 1ms rectangular pulse was used to determine conduction velocity. After application of calcium chloride (1, 2, 6M), calcium hydroxide mixed with saline, potassium chloride (0.2, 0.8, 1.6M), eugenol, zinc oxide eugenol to the cavity on the labial surface, conduction velocity and threshold current of single pulp nerve unit were compared with the control. In 10 cats, 24 $A{\delta}$- and 11 C- pulp nerve units were recorded. The mean conduction velocities of $A{\delta}$- and C-fibers were 7.5m/sec (SD=5.8) and 1.2m/sec (SD=0.4), respectively. The mean threshold current was $12.3{\mu}A$ (SD=5.3) for $A{\delta}$-fibers and $24.9{\mu}A$ (SD=8.1) for C-fibers. 1, 2, 6M calcium chloride caused decrease of conduction velocity and remarkable increase of threshold current in $A{\delta}$- and C-fibers. The effect of calcium hydroxide mixed with saline was similar but smaller than calcium chloride solution. 0.2M potassium chloride had insignificant effect. In 0.8M potassium chloride, the threshold current was increased although conduction velocity was not affected. In 1.6M potassium chloride, the threshold current was increased and the conduction velocity was slowed down. Spontaneous activity was recorded frequently for first 5 min but gradually reduced both in $A{\delta}$- and C-fibers. Eugenol had irreversible effect on pulp nerve in that initially there were not certain changes in the conduction velocity and threshold current of $A{\delta}$- and C-fibers, but the responses to electrical stimulation were abruptly disappeared after sustained application and were not recovered. Contrary to eugenol, zinc oxide eugenol did not caused significant increase of the threhold current and caused time dependent decrease of the conduction velocity, and did not show any irreversible change.

  • PDF

ENDODONTIC TREATMENT OF A PERIRADICULAR LESION ON AN INVAGINATED TYPE III MAXILLARY LATERAL INCISOR (Type III 치내치를 동반한 상악 측절치에 이환된 치근단 병소의 근관 치료)

  • Kim, Ki-Rim;Lee, Jae-Ho;Kim, Seong-Oh;Song, Je-Seon;Choi, Byung-Jai;Kim, Seung-Hye;Choi, Hyung-Jun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.2
    • /
    • pp.181-185
    • /
    • 2012
  • Dens invaginatus is a developmental anomaly resulting in a deepening or invagination of the enamel organ into the dental papilla prior to calcification of the dental tissues. The most widely used classification of dens invaginatus is the system described by Oehler categorizes invaginations into three classes as determined by how far they extend radiographically from the crown into the root. Oehler's classification type III is that the invagination extends through the root and communicates with the periodontal ligament. There is usually no communication with the pulp. In Type III lesions, any infection within the invagination can lead to an inflammatory response within the periodontal tissues giving rise to a 'peri-invagination periodontitis'. In the cases presented here, we treated two patients who were refered for 'peri-invagination periodontitis' on maxillary lateral incisor with Oehler's type III invagination by different approaches each, and they have shown satisfactory outcomes. Although there are several approaches to the management of dens invaginatus, the most important objective is to preserve the health of the pulp, which can be achieved by early diagnosis and the prophylactic treatment regardless of severity. When disease has developed, decision has to be made whether to treat the invagination and the pulp separately.

Age Estimation by Dental Radiographs in Korean Adults (한국 성인에서 치과용 방사선사진에 의한 연령감정)

  • Jeon, Hee-Sun;Tea, Il-Ho;Ko, Myung-Yun;Ahn, Yong-Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.2
    • /
    • pp.179-188
    • /
    • 2009
  • Aim of this study is to examine correlation between size of the coronal pulp cavity and chronological age in adult. Total 716 teeth (218 mandibular canines, 230 first premolars, 268 second premolars) free from pathologies and dental restorations were selected from 276 patients (111 males, 165 females), ranging from 20-69 years. Using periapical X-ray, the height (mm) of the crown (CH=coronal height) and the height (mm) of the coronal pulp cavity (CPCH=coronal pulp cavity height) of the teeth were measured. The tooth-coronal index (TCI) after Ikeda et al (Jpn. J. For. Med. 1985;39:244-250) was computed for each tooth and regressed on real age. With increasing age, the TCI was relatively decreased, indicating the reduction of length of the pulp chamber. Even reduction of the TCI with aging was found in combined group rather than in each sex and type of tooth separately. The most definite reduction was in canine of combined group. The correlation coefficient was strongest when measurement from canines of females (r2=0.247).

Clinical Convergence Angle of Prepared Tooth for full Veneer Crowns (전부 피개관의 치아 형성 시 축면 경사각에 대한 조사)

  • Kim, Sung-Jin;Pae, Ah-Ran;Woo, Yi-Hyung;Kim, Hyeong-Seob
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.1
    • /
    • pp.21-32
    • /
    • 2010
  • The convergence angle of a prepared tooth is a very important factor in the retention and resistance of a crown restoration. But various intraoral environments and clinician's techniques make it difficult to obtain the ideal inclination. Therefore, in this study, clinical convergence angle of a prepared tooth was investigated. The data was collected from the patient models of prosthodontic residents and the patient models of general practitioners. The images of mesiodistal and buccolingual surfaces were taken with a digital camera to evaluate the convergence angle on 'ImageJ' program. The images were classified according to the criteria (1. Clinician group, 2. Position in the dental arch, 3. The purpose of abutment preparation)and then analyzed. The mean convergence angle of a prepared tooth for Korean clinicians was $15.02^{\circ}$ (${\pm}10.13^{\circ}$). 1. It was significant in the convergence angle between the general practitioner group and the prosthodontic resident group(p<0.05). 2. It was significant between the mesiodistal and buccolingual surface in the the prosthodontic resident group(p<0.05). 3. For the general practitioner group, it was significant when anteriors and premolars were compared with molars(p<0.05). For the prosthodontic resident group, it was significant when anteriors and premolars were compared with molars (p<0.05). 4. When divided into upper and lower arches, for the general practitioner group, it showed significant difference in the buccolingual aspect(p<0.05). Also in the prosthodontic resident group, it showed significant difference in the buccolingual aspect(p<0.05). 5. Dividing left and right sides of the arches, there was no significant difference in the general practitioner group and the prosthodontic resident group(p>0.05). 6. In the general practitioner group, it was significant in the mesiodistal axial convergence angle of single crown abutment and 3 unit bridge abutment(p<0.05). In the prosthodontic resident group, it was significant in the mesiodistal and overall axial convergence angle of single crown abutment and 3 unit bridge abutment(p<0.05). Clinical convergence angle of prepared tooth in Korea was included in agreement with other studies investigating convergence angle that ranged from 10 to 22 degrees, achieved in clinical practice.

Comparison of micro CT and cross-section technique for evaluation of marginal and internal fit of lithium disilicate crowns (전부 도재관의 변연 및 내면 간극에 대한 micro CT와 절단 시편 측정법의 비교)

  • Ko, In-Seok;Kim, Jeong-Mi;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.226-233
    • /
    • 2016
  • Purpose: The purpose of this study was to evaluate the adaptation of lithium disilicate crowns fabricated by CAD-CAM (computer aided design-computer aided manufacturing) and heat-press technique to compare two different measurement methods in assessing fit of the ceramic crowns: micro CT and cross-section technique. Materials and methods: A prepared typodont mandibular molar for ceramic crown was duplicated and ten dies were produced by milling the PMMA (polymethylmethacrylate) resin. Ten vinyl polysiloxane impressions were made and stone casts were produced. Five dies were used for IPS e.max Press crowns with heat-press technique. The other five dies were used for IPS e.max CAD crowns with CAD-CAM technique. Ten lithium disilicate crowns were cemented on the resin dies using zinc phosphate cement with finger pressure. The marginal and internal fits in central buccolingual plane were evaluated using a micro CT. Then the specimens were embedded and cross-sectioned and the marginal and internal fits were measured using scanning electronic microscope. The two measurement methods and two manufacturing methods were compared using Mann-Whitney U test (SPSS 22.0). Results: The marginal and internal fit values using micro CT and cross-section technique were similar, showing no significant differences. There were no significant differences in adaptation between lithium disilicate crowns fabricated with CAD-CAM and heat-press technique. Conclusion: Both micro CT and cross-section technique were acceptable methods in the evaluation of marginal and internal fit of lithium disilicate crown. There was no difference in adaptation between lithium disilicate crowns fabricated with CAD-CAM and heat-press technique except occlusal fit.

Evaluation of reverse torque value of abutment screws on CAD/CAM custom-made implant abutments (CAD/CAM을 이용한 맞춤형 임플란트 지대주의 나사 풀림 토크 평가)

  • Lee, Chang-Jae;Yang, Sung-Eun;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.128-134
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the screw joint stability between the CADCAM custom-made implant abutment and the prefabricated implant abutment by measuring the reverse torque value after cyclic loading. Materials and methods: Twelve screw type implants (Implantium, Dentium Co., Seoul, Korea) were embedded in aluminum cylinder with acrylic resin. The implant specimens were equally divided into 3 groups, and connected to the prefabricated titanium abutments (Implantium, Dentium Co., Seoul, Korea), CADCAM custom-made titanium abutments (Myplant, Raphabio Co., Seoul, Korea) and CADCAM custom-made zirconia abutments (Zirconia Myplant, Raphabio Co., Seoul, Korea). The CAD-CAM milled titanium crown (Raphabio Co., Seoul, Korea) was cemented on each implant abutment by resin cement. Before cyclic loading, each abutment screw was tightened to 30 Ncm and the reverse torque value was measured about 30 minutes later. After the crown specimen was subjected to the sinusoidal cyclic loading (30 to 120 N, 500,000 cycles, 2 Hz), postloading reverse torque value was measured and the reverse torque loss ratio was calculated. Kruskal-Wallis test was used for statistical analysis of the reverse torque loss ratio. Results: The CADCAM custom-made titanium abutments presented higher values in reverse torque loss ratio without statistically significant differences than the prefabricated titanium abutments ($P$>.05). Reverse torque loss ratio of the custom-made zirconia abutments was significantly higher compared to that of the prefabricated titanium abutments ($P$=.014). Conclusion: Within the limitation of the present $in-vitro$ study, it was concluded that there was no significant difference in screw joint stability between the CADCAM custom-made titanium abutments and the prefabricated titanium abutments. On the other hand, the CADCAM custom-made zirconia abutments showed lower screw joint stability than prefabricated titanium abutments.

INFLUENCE OF SEVERAL POSTS AND IPS-EMPRESS INGOT THICKNESS ON THE FINAL SHADE OF ALL-CERAMIC CROWNS (수종의 post와 IPS-Empress Ingot 두께가 전부 도재 수복물 최종색조에 미치는 영향)

  • Bok Won-Mi;Choi Keun-Bae;Park Charn-Woon;Ahn Seung-Geun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.514-523
    • /
    • 2004
  • Statement of problem: All-ceramic restorations have been advocated for superior esthetics. Various post and core systems have been used to improve the strength of damaged teeth, but it is unclear whether they affect the final shade of finished all-ceramic restorations. Purpose: The influence of different types of post and core systems on light transmission through all-ceramic crowns was assessed by spectrophotometric analysis. Also the masking effect of different thickness of ceramic ingot was evaluated. Material and Methods : Forty-five sample disks (15mm in diameter) at several thickness(1.0, 1.5, 2.0mm) and value(shade 100, 200, 300) were made in heat pressed ceramic(IPS-Empress). Background specimens simulating gold-alloy cast posts(Type III casting gold alloy), metal posts(Ni-Cr casting alloy) and ceramic posts(CosmoPost) were fabrica-ted. Resin composite(Z250, A3 shade) was used as a tooth substrate reference. For each combination, the change in color was measured with a spectrophotometer. Readings were performed for 2 conditions (1) ability of ceramic to mask the core in relation to its thickness(1.0, 1.5, or 2.0mm) ; (2) influence of post and core types on the final color of the ceramic. Data were recorded according to the CIE $L^*a^*b^*$ systems and color difference($\Delta$E) was calculated. Results: 100 shade ingot: when ceramic thickness was 1.0mm, $\Delta$E value for ceramic post larger than 1 but $\Delta$E value for metal and gold post was larger than 2. For ceramic thickness of 1.5mm, only $\Delta$E value for metal was larger than 2, and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 2. 200 shade ingot: when ceramic thickness was 1.0mm, $\Delta$E value for ceramic post was smaller than 1 but $\Delta$E value for metal and gold post was larger than 2. For ceramic thickness of 1.5 mm, only the $\Delta$E value for metal was larger than 2, and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 1. 300 shade ingot: when ceramic thickness was 1.0mm, only $\Delta$E value for metal was larger than 2 and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 1.5mm, $\Delta$E values for all specimens was smaller than 1. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 1. Conclusion: The final esthetic result of the IPS-Empress glass-ceramic restoration was not affected by the presence of different core materials when the thickness was more than 2.0 mm. When ceramic thickness decreases to 1.5mm, it is advised to take the substrate aspects into consideration. If the ceramic thickness is less than 1.0mm, using the tooth color matched substrate is strongly recommended.

AN EPIDEMIOLOGIC STUDY ON THE PEDIATRIC PATIENTS IN DEPARTMENT-OF PEDIATRIC DENTISTRY, CHOSUN UNIVERSITY DENTAL HOSPITAL FOR LAST 10 YEARS(1990-1999) (최근 10년간 조선대학교 치과병원 소아치과에 내원한 신환에 관한 역학적 연구(1990-1999))

  • Ryu, Hyun-Seop;Kim, Hyo-Suck;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.345-354
    • /
    • 2001
  • The purpose of this study was to make public oral health plan more effective and the improvement of the hospital management system for better clinical dental practice. Distribution and trends were examined in all patients who had been examined and diagnosed at Department of Pedodontics, Dental Hospital, Chosun University over 10 year-period from 1990 to 1999 Results were as follows, 1. The number of patients per year was increasing trend after 1996 and higher visiting rate in male(55.9%) than in female(44.1%). 2. Age distribution had shown $3\sim4$ year-old cup being the largest (23.4%) and each percentage of $5\sim6,\;7\sim8,\;0\sim2,\;9\sim10,\;11\sim12,\;13\sim14,\;above\sim15$ year-old group was 19.9%, 17.7%, 14.6%, 12.6%, 8.0%, 3.3%. 0.5%. 3. Geographic distribution showed a majority of patients in Kwang-Ju (83.0%). Group in the suburbs of Kwang-Ju(Jang-Sung group) was 5.4%. 4. Dental caries showed the highest percentage(40.5%) in chief complaints and percentage of oral exam, orthodontic problem, oral pain, trauma, supernumerary teeth, swelling was 13.9% 12.6%, 8.8%, 7.4%, 5.5%, 4.9%. 5. In all patients with traumatic problem, crown fracture showed the highest percentage(41.4%) and percentage of subluxation was 19.4%. 6. Majority(78.7%) of patients were not refered, and percentage of patients refered from local clinic was 20.5%. 7. Patients who had periodic check-up comprised 19.6%, and percentage of after 3, 6, 9, 12, 18, 24month was 36.7%, 22.2%, 13.5%, 11.3%, 5.4%, 11.0%.

  • PDF

Effect of thread design on the marginal bone stresses around dental implant (임플란트 나사산 디자인이 변연골 응력에 미치는 영향)

  • Lee, Sang-Hyun;Jo, Kwang-Heon;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.316-323
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the effect of different thread designs on the marginal bone stresses around dental implant. Materials and methods: Standard ITI implant(ITI Dental Implant System; Straumann AG, Waldenburg, Switzerland), 4.1 mm in diameter and 10 mm in length, was selected as control. Test implants of four different thread patterns were created based on control implant, i.e. maintaining all geometrical design of control implant except thread pattern. Four thread designs used in test implants include (1) small V-shape screw (model A), (2) large V-shape screw (model B), (3) buttress screw (model C), and (4) trapezoid screw (model D). Surface area for unit length of implant was 14.4 $mm^2$ (control), 21.7 (small V-shape screw), 20.6 (large V-shape screw), 17.0 (buttress screw) and 28.7 $mm^2$ (trapezoid screw). Finite element models of implant/bone complex were created using an axisymmetric scheme with the use of NISA II/DISPLAY III (Engineering Mechanics Research Corporation, Troy, MI, USA). A load of 100 N applied to the central node on the crown top either in parallel direction or at 30 degree to the implant axis (in order to apply non-axial load to the implant NKTP type 34 element was employed). Quantification and comparison of the peak stress in the marginal bone of each implant model was made using a series of regression analyses based on the stress data calculated at the 5 reference points which were set at 0.2, 0.4, 0.6, 0.8 and 1.0 mm from implant wall on the marginal bone surface. Results: Results showed that although severe stress concentration on the marginal bone cannot be avoided a substantial reduction in the peak stress is achievable using different thread design. The peak marginal bone stresses under vertical loading condition were 7.84, 6.45, 5.96, 6.85, 5.39 MPa for control and model A, B, C and D, respectively. And 29.18, 26.45, 25.12, 27.37, 23.58 MPa when subject to inclined loading. Conclusion: It was concluded that the thread design is an important influential factor to the marginal bone stresses.

EXPRESSION PATTERN OF RUNX2 IN MURINE TOOTH DEVELOPMENT (Mouse의 치아 발육시 Runx2의 발현 양상)

  • Kim, Tae-Wan;Ryoo, Hyun-Mo;Nam, Soon-Hyeun;Kim, Young-Jin;Kim, Hyun-Jung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.651-658
    • /
    • 2004
  • Runx2 is a transcription factor in homologous with Drosophila runt gene and it is essential for bone formation during embryogenesis and a critical gene for osteoblast differentiation and osteoblast function. Runx2-haploinsufficency causes cleidocranial dysplasia (CCD). CCD is an autosomal-dominant inherited disorder characterized by hypoplastic clevicle and delayed ossification in fontanelles and wormian bones. Dental defects are possibly shown to CCD patients : multiple supernumerary teeth, irregular and compressed permanent tooth crowns, hypoplastic and hypomineralized defects in enamel and dentin, an excess of epithelial root remnants, the absence of cellular cementum, and abnormally shaped roots. In addition, delayed eruption of the secondary dentition is a constant finding. The aim of this study is to evaluate the role of Runx2 in the tooth development and eruption through analyzing the expression pattern of Runx2 by in situ hybridization during crown (late bell stage) and root formation of tooth, using postnatal day 1, 4, 7, 14 and 21 mice mandibular molar teeth. mRNA of Runx2-full length is expressed in dental follicle and surrounding tissue at postnatal day1 and 4. At postnatal day 7, it is expressed in ameloblasts of occlusal surface of enamel and bone area surrounding the tooth. In comparison with previous stage, at postnatal day 14, it is expressed in ameloblasts of proximal surface of enamel. At postnatal day 21 it's expression is observed only in bone area. mRNA of Runx2-typeII is not expressed. At postnatal day 1 and 7. At postnatal day 14 and 21, it's expression is observed in the bone area. In this study, we suggest that Runx2 have a relation of ameloblasts differentiation and an important role to tooth eruption made by dental follicle during intraosseous eruption stage. Also we can confirm that Runx2 has a role to bone formation.

  • PDF