• Title/Summary/Keyword: Crown dental

Search Result 880, Processing Time 0.021 seconds

Comparison of marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures fabricated from solid working casts and working casts from a removable die system (가철성 다이 시스템으로 제작된 작업 모형과 솔리드 작업 모형 상에서 제작된 지르코니아 3본 고정성 치과 보철물의 변연 및 내면 적합도 비교)

  • Wan-Sun Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.72-81
    • /
    • 2024
  • Purpose: This study aimed to assess the marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures (FPDs) fabricated via computer-aided design and computer-aided manufacturing (CAD/CAM) from solid working casts and removable die system. Materials and Methods: The tooth preparation protocol for a zirconia crown was executed on the mandibular right first premolar and mandibular right first molar, with the creation of a reference cast featuring an absent mandibular right second premolar. The reference cast was duplicated using polyvinyl siloxane impression, from which 20 working casts were fabricated following typical dental laboratory procedures. For comparative analysis, 10 FPDs were produced from a removable die system (RD group) and the remaining 10 FPDs from the solid working casts (S group). The casts were digitized using a dental desktop scanner to establish virtual casts and design the FPDs using CAD. The definitive 3-unit monolithic zirconia FPDs were fabricated via a CAM milling process. The seated FPDs on the reference cast underwent digital evaluation for marginal and internal fit. The Mann-Whitney U test was applied for statistical comparison between the two groups (α = 0.05). Results: The RD group showed significantly higher discrepancies in fit for both premolars and molars compared to the S group (P < 0.05), particularly in terms of marginal and occlusal gaps. Color mapping also highlighted more significant deviations in the RD group, especially in the marginal and occlusal regions. Conclusion: The study found that the discrepancies in marginal and occlusal fits of 3-unit monolithic zirconia FPDs were primarily associated with those fabricated using the removable die system. This indicates the significant impact of the fabrication method on the accuracy of FPDs.

Fracture resistances of zirconia, cast Ni-Cr, and fiber-glass composite posts under all-ceramic crowns in endodontically treated premolars

  • Habibzadeh, Sareh;Rajati, Hamid Reza;Hajmiragha, Habib;Esmailzadeh, Shima;Kharazifard, Mohamadjavad
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.3
    • /
    • pp.170-175
    • /
    • 2017
  • PURPOSE. The aim of the present study was to evaluate the fracture resistances of zirconia, cast nickel-chromium alloy (Ni-Cr), and fiber-composite post systems under all-ceramic crowns in endodontically treated mandibular first premolars. MATERIALS AND METHODS. A total of 36 extracted human mandibular premolars were selected, subjected to standard endodontic treatment, and divided into three groups (n=12) as follows: cast Ni-Cr post-and-core, one-piece custom-milled zirconia post-and-core, and prefabricated fiber-glass post with composite resin core. Each specimen had an all-ceramic crown with zirconia coping and was then loaded to failure using a universal testing machine at a cross-head speed of 0.5 mm/min, at an angle of 45 degrees to the long axis of the roots. Fracture resistance and modes of failure were analyzed. The significance of the results was assessed using analysis of variance (ANOVA) and Tukey honest significance difference (HSD) tests (${\alpha}=.05$). RESULTS. Fiber-glass posts with composite cores showed the highest fracture resistance values ($915.70{\pm}323N$), and the zirconia post system showed the lowest resistance ($435.34{\pm}220N$). The corresponding mean value for the Ni-Cr casting post and cores was reported as $780.59{\pm}270N$. The differences among the groups were statistically significant (P<.05) for the zirconia group, as tested by ANOVA and Tukey HSD tests. CONCLUSION. The fracture resistance of zirconia post-and-core systems was found to be significantly lower than those of fiber-glass and cast Ni-Cr post systems. Moreover, catastrophic and non-restorable fractures were more prevalent in teeth restored by zirconia posts.

THE EFFECT OF INTERNAL IMPLANT-ABUTMENT CONNECTION AND DIAMETER ON SCREW LOOSENING

  • Ha, Chun-Yeo;Kim, Chang-Whe;Lim, Young-Jun;Jang, Kyung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.379-392
    • /
    • 2005
  • Statement of problem. One of the common problems of dental implant prosthesis is the loosening of the screw that connects each component, and this problem is more common in single implant-supported prostheses with external connection, and in molars. Purpose. The purposes of this study were: (1) to compare the initial abutment screw detorque values of the six different implant-abutment interface designs, (2) to compare the detorque values of the six different implant-abutment interface designs after cyclic loading, (3) to compare the detorque values of regular and wide diameter implants and (4) to compare the initial detorque values with the detorque values after cyclic loading. Material and methods. Six different implant-abutment connection systems were used. The cement retained abutment and titanium screw of each system were assembled and tightened to 32Ncm with digital torque gauge. After 10 minutes, initial detorque values were measured. The custom titanium crown were cemented temporarily and a cyclic sine curve load(20 to 320N, 14Hz) was applied. The detorque values were measured after cyclic loading of one million times by loading machine. One-way ANOVA test, scheffe’s test and Mann-Whitney U test were used. Results. The results were as follows : 1. The initial detorque values of six different implant-abutment connections were not significantly different(p>0.05). 2. The detorque values after one million dynamic cyclic loading were significantly different (p<0.05). 3. The SS-II regular and wide implant both recorded the higher detorque values than other groups after cyclic loading(p<0.05). 4. Of the wide implants, the initial detorque values of Avana Self Tapping Implant, MIS and Tapered Screw Vent, and the detorque values of MIS implant after cyclic loading were higher than their regular counterparts(p<0.05). 5. After cyclic loading, SS-II regular and wide implants showed higher detorque values than before(p<0.05).

Severe Recurrent Gingival Bleeding and Toothache Control in a Patient with Liver Cirrhosis and Oral Metastatic Hepatoma: Report of a Case (간경화증과 구강전이 간암환자에서 과도한 재발성 치은출혈과 치통조절: 증례보고)

  • Lee, Chun-Ui;Mo, Dong-Yub;Yoo, Jae-Ha;Choi, Byung-Ho;Kim, Jong-Bae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.6
    • /
    • pp.592-596
    • /
    • 2010
  • The common local causes of active gingival bleeding are the vessel engorgement and erosion by severe inflammation and injury to hypervascularity lesion. Abnormal gingival bleeding is also associated with systemic bleeding disorders (liver disease, leukemia etc.). There are many conventional methods for gingival bleeding control, such as, direct pressure, packing, electrocoagulation, tight suture and application of hemostatic agents. If the continuous gingival bleeding is not stopped in spite of the all local application methods, the medical consultation should be obtained for systemic condition care and the major feeding arterial embolization. This is a case report of severe gingival bleeding and periodontitis control in a patient with liver cirrhosis and oral metastatic lesion of hepatocellular carcinoma. The bleeding lesion was placed in left buccal mucosa and gingiva of the left mandibular molars. The control methods were dental crown removal, primary endodontic drainage, gingival sulcus drainage and maxillary arterial embolization with medical consultation.

RESTORATION OF MISSED MAXILLARY CENTRAL INCISOR USING AUTOTRANSPLANTATION OF MESIODENS : A CASE REPORT (정중과잉치의 자가이식을 통한 상실된 상악 중절치의 수복 : 증례보고)

  • Kim, Hye-Kyoung;Park, Ho-Won;Lee, Ju-Hyun;Seo, Hyun-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.3
    • /
    • pp.519-525
    • /
    • 2007
  • Supernumerary tooth is developed from overgrowth of dental laminar and is mainly observed in the maxillary anterior area, named 'mesiodens. Mesiodens cause many problems such as malposition of permanent anterior tooth, diastema, formation of cyst, and eruption to oral or nasal cavity. Extraction, therefore, is generally recommended choice of treatment. This case report describes that the patient is a 9 years and 8 months old boy, whose unilateral maxillary incisor was missing due to trauma, and he had a mesiodens. We practiced autotransplantation of the mesiodens to the missing maxillary central incisor area and then restored with prosthetics, substantially kept out alveolar bony resorption and provided esthetic appearance. Mesiodens was too small to be used as an abutment because its length is totally 14mm, so that poor prognosis was anticipated due to bad crown/root ratio. However, we observed clinically acceptable result during the observation period of 8 months after operation.

  • PDF

Immediate loading of mandibular single implant by using surgical guide and modeless digital prosthesis: a case report (수술용 가이드와 modeless 디지털 보철물을 이용한 하악 구치부 단일 임플란트 즉시 하중 증례)

  • Lim, Hyun-jeong;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.299-306
    • /
    • 2017
  • In this case report, immediate loading of an implant-supported single-tooth prosthesis through complete digital workflow. A patient presented for restoration of missing a single tooth in the mandibular first molar. The digital impression was made with intraoral scanner and implant was placed using surgical guide pre-fabricated with pre-operative computed tomography (CT) and scan data. After 1 week later, prefabricated customized abutment and provisional restoration were connected for immediate loading. After 8 weeks later, abutment level impression was taken by intraoral scanner. At 3 months later from implant installation, monolithic zirconia crown were fabricated. This clinical report presents satisfying result in accuracy and patient satisfaction. A completely modeless digital procedure met expectations regarding precision, esthetics, and functionality.

RECONSTRUCTION OF SEVERE BUCCO-LINGUAL BONE RESORPTION AREA USING "RIDGE SPLITTING TECHNIQUE" (심한 협-설골 위축에서 치조골 수평 확장술을 이용한 골 재건)

  • Yeo, Duck-Sung;Lim, So-Yeon;Lee, Hyun-Jin;Ahn, Mi-Ra;Sohn, Dong-Seok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.6
    • /
    • pp.590-594
    • /
    • 2006
  • Dental implant has become one of the important option for completely or partially edentulous patients, But it is challenging to reconstruct the severely atrophic ridge. Insufficient bone volume could restrict to place the wide and long implant and because of excessive interocclusal clearance, improper prosthetics could be produced. In this case bone augmentation for implant dentistry is necessary procedure to improve the insufficient bone volume. Therefore, bone augmentation or GBR is the most important procedure for successful implant placement and for ideal crown- root ratio. There are various bone augmentation techniques have been introduced recently; like block bone graft, distraction osteogenesis, inlay graft, onlay graft, etc.... In severe bucco-lingual resorption area, ridge splitting is the first choice of the treatment, because it provides a place for implantation and also has compaction effect. This technique may be indicated for sharp mandible and maxillary ridges in patients whose bone quantity is inadequate for primary stabilization. We report that the clinical experience of bone augmentation using ridge splitting technique in bucco-lingual bone resorption area.

The maxillary incisor labial face tangent: clinical evaluation of maxillary incisor inclination in profile smiling view and idealized aesthetics

  • Naini, Farhad B.;Manouchehri, Shaadi;Al-Bitar, Zaid B.;Gill, Daljit S.;Garagiola, Umberto;Wertheim, David
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.31.1-31.7
    • /
    • 2019
  • Background: To test the hypothesis that in profile smiling view, for ideal aesthetics, a tangent to the labial face of the maxillary central incisor crowns should be approximately parallel to the true vertical line and thereby perpendicular to the true horizontal line. Methods: An idealized female image was created with computer software and manipulated using the same software to construct an "ideal" female profile image with proportions, and linear and angular soft tissue measurements, based on currently accepted criteria for idealized Caucasian profiles. The maxillary incisor labial face tangent was altered in 5° increments from 70 to 120°, creating a range of images, shown in random order to 70 observers (56 lay people and 14 clinicians), who ranked the images from the most to the least attractive. The main outcome was the preference ranks of image attractiveness given by the observers. Results: The most attractive inclination of a tangent to the labial face of the maxillary incisor crowns in profile view in relation to the true horizontal line was 85°, i.e. 5° retroclined from a perpendicular 90° inclination. The most attractive range appears to be between 80 and 90°. Excessive proclination appeared to be less desirable than retroclination. Beyond 105° most observers recommend treatment. Conclusion: In natural head position, the ideal inclination of the maxillary incisor crown labial face tangent in profile view will be approximately parallel to the true vertical line and thereby approximately perpendicular to the true horizontal line.

Skeletal and dentoalveolar changes after miniscrew-assisted rapid palatal expansion in young adults: A cone-beam computed tomography study

  • Park, Jung Jin;Park, Young-Chel;Lee, Kee-Joon;Cha, Jung-Yul;Tahk, Ji Hyun;Choi, Yoon Jeong
    • The korean journal of orthodontics
    • /
    • v.47 no.2
    • /
    • pp.77-86
    • /
    • 2017
  • Objective: The aim of this study was to evaluate the skeletal and dentoalveolar changes after miniscrew-assisted rapid palatal expansion (MARPE) in young adults by cone-beam computed tomography (CBCT). Methods: This retrospective study included 14 patients (mean age, 20.1 years; range, 16-26 years) with maxillary transverse deficiency treated with MARPE. Skeletal and dentoalveolar changes were evaluated using CBCT images acquired before and after expansion. Statistical analyses were performed using paired t-test or Wilcoxon signed-rank test according to normality of the data. Results: The midpalatal suture was separated, and the maxilla exhibited statistically significant lateral movement (p < 0.05) after MARPE. Some of the landmarks had shifted forwards or upwards by a clinically irrelevant distance of less than 1 mm. The amount of expansion decreased in the superior direction, with values of 5.5, 3.2, 2.0, and 0.8 mm at the crown, cementoenamel junction, maxillary basal bone, and zygomatic arch levels, respectively (p < 0.05). The buccal bone thickness and height of the alveolar crest had decreased by 0.6-1.1 mm and 1.7-2.2 mm, respectively, with the premolars and molars exhibiting buccal tipping of $1.1^{\circ}-2.9^{\circ}$. Conclusions: Our results indicate that MARPE is an effective method for the correction of maxillary transverse deficiency without surgery in young adults.

AN EXPERIMENTAL STUDY OF BOND STRENGTH OF GLASS IONOMER LUTING CEMENT UNDER THE FUNCTIONAL LOADS ON THE CROWN (기능 하중 하에서 접착용 Glass Ionomer 시멘트의 결합강도에 대한 비교연구)

  • Jun Joong-Hyun;Kang Woo-Jin;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.2
    • /
    • pp.225-232
    • /
    • 1992
  • The purpose of this study was to compare the bond strength of the glass ionomer luting cements after the functional loads were applied to the crowns respectively 10 min, 30 min, 1 hr, 24 hrs later after mixing of cements. The conventional (GC Fuji I; GC Int. Co., Japan), water hardening type (Ketac Cem; ESPE, W. Germany) glass ionomer luting cement and C-dent ZPC (Confi-Dental Products Co., U.S.A.) as a control were used. The results of this study were obtained as follows: 1. In the bond strength of GC Fuji I, 24 hr-group was highest and there were no statistically significant differences among 10 min-, 30 min- and 1 hr- groups. 2. l3 the bond strength of Ketac Cem and C-dent ZPC, there was no statistically significant differences among 10 min-, 30 min-, 1 hr- and 24 hr-groups respectively. 3. Comparing the bond strength among cements in 10 min-, 30 min-groups respectively, GC Fuji I was lowest and there was no statistically significant difference between Ketac Cem and C-dent ZPC. 4. The bond strengths between GC Fuji I and Ketac Cem were not significantly different in 1 hr-, 24 hr-group. 5. The bond strengths among 3 types of cements were not significantly different in 24 hr-groups.

  • PDF