• Title/Summary/Keyword: Crown dental

Search Result 879, Processing Time 0.032 seconds

A Study on Clinical Crown Angulation and Inclination of Females in the Twenties with Normal Occlusion (20대 여성 정상교합자에서 임상치관의 순·설측 경사도와 근·원심 경사도에 관한 연구)

  • Cho, Hong-Kyu
    • Journal of Technologic Dentistry
    • /
    • v.35 no.4
    • /
    • pp.415-424
    • /
    • 2013
  • Purpose: This study is to present a standard value for clinical crown angulation and inclination required in laboratory process and see if the value can be used for actual laboratory process. Methods: In order to find out a standard value for clinical crown angulation and inclination, this study made a study model of normal occlusion of 21 females in twenties. The clinical crown angulation and inclination of both six-maxillary and six-mandibular anterior teeth are measured by Set-up Model Checker. From the measured value above, the mean and standard deviation of the twelve teeth are obtained, and then the mean of the teeth between right and left side is calculated. Results: Each clinical crown angulation of maxillary central incisor, lateral incisor, and canine is like this; $1.0^{\circ}{\pm}1.3^{\circ}$, $3.0^{\circ}{\pm}1.3^{\circ}$, and $5.0^{\circ}{\pm}1.4^{\circ}$. In case of mandibular, each degree is like this; $0.6^{\circ}{\pm}1.1^{\circ}$, $1.5^{\circ}{\pm}1.1^{\circ}$, and $4.1^{\circ}{\pm}1.1^{\circ}$. Each clinical crown inclination of maxillary central incisor, lateral incisor, and canine is like this; $6.1^{\circ}{\pm}1.8^{\circ}$, $4.5^{\circ}{\pm}1.9^{\circ}$, and $-6.2^{\circ}{\pm}1.4^{\circ}$. In case of mandibular, each degree is like this; $0.3^{\circ}{\pm}1.5^{\circ}$, $0.3^{\circ}{\pm}1.8^{\circ}$, and $-7.5^{\circ}{\pm}1.8^{\circ}$. Conclusion: As the result, the mean value for clinical crown angulation and inclination can be referred to actual laboratory process. However, the mean value is different from those of the precedent study and an unsatisfied one for adopting the standard value.

Observation of Occlusal Relations for Production to Dental Prosthetics of Dogs (중형견 치과보철물 제작을 위한 교합관계 관찰)

  • Park, Yu-Jin;Choi, Sung-Min
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.203-208
    • /
    • 2016
  • Purpose: This study introduces the production process of dog's dental prosthesis using an automated dental prosthetics technology. The occlusal interaction of dog's dental prosthesis was observed. Methods: This study was proceeded with dog's the mandibular first molar teeth. The 3D CAD designed to 3D model specimens was observed by CAD software. and The specimens designed to 3D model specimens was observed occlusal interaction by using articulator. Results: Occlusal contact point in prosthetic specimens were observed in buccal surface. and 98% of the size of the crown is the best occlusal relationship. Conclusion: Observation of occlusal relations result to 98% of the size of the crown is the best.

Esthetic Restoration of Deciduous Teeth Using Prefabricated Zirconia Crown in Children with Early Childhood Caries: A Report of Three Cases

  • An, So-Youn;Shim, Youn-Soo
    • Journal of dental hygiene science
    • /
    • v.18 no.3
    • /
    • pp.194-200
    • /
    • 2018
  • Early childhood caries is a widespread condition that requires attention; however, its treatment remains a challenge in terms of child behavior management. This study describes the usefulness of customized zirconia crowns for the restoration of deciduous teeth through the evaluation of some cases. Three cases are described: a 29-month-old girl who presented with severe early childhood caries affecting anterior tooth, a 50-month-old boy who presented with extensive caries of his anterior tooth, and 70-month-old girl who presented with extensive caries of his primary posterior dentition. These prefabricated, zirconium-based ceramic crowns ($Nusmile^{TM}$ NuSmile) are available in various sizes, shapes and colors. Before the treatment, radiographs and intraoral photographs were taken to evaluate the appropriateness of treatment. Our findings indicate that customized zirconia crowns may be appropriate for restoring the deciduous teeth. Further long-term clinical studies are required to clarify the usefulness of this restorative method.

Management of a permanent maxillary first molar with unusual crown and root anatomy: a case report

  • Chowdhry, Prateeksha;Reddy, Pallavi;Kaushik, Mamta
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.3
    • /
    • pp.35.1-35.7
    • /
    • 2018
  • The aim of this article was to showcase the endodontic management of a maxillary first molar with an unusual crown and root anatomy. Clinical diagnosis of the roots and root canal configuration was confirmed by a cone-beam computed tomography (CBCT) and the detection of the canals was made using a dental operating microscope. CBCT images revealed the presence of 5 roots with Vertucci type I canal configuration in all, except, in the middle root which had 2 canals with type IV configuration. The 6 canal orifices were clinically visualized under the dental operating microscope. Clinicians should familiarize themselves with the latest technologies to get additional information in endodontic practice in order to enhance the outcomes of endodontic therapy.

Tribological Characteristics of Dental Metal Alloys (치과 보철용 금속 합금의 마찰 마멸 특성)

  • Kim, J.H.;Choi, W.S.
    • Tribology and Lubricants
    • /
    • v.29 no.4
    • /
    • pp.235-241
    • /
    • 2013
  • The tribological characteristics of dental metal alloys and zirconia were studied by carrying out a friction and wear performance test. In this study, a pin-on-disk-type tester was used and dead weight was employed as the normal load applied to the test specimen. The friction coefficient of dental metal alloys was investigated in terms of their weight and sliding velocity. Microscopic observations were carried out on worn surfaces of specimens. The results indicated that among all metal alloys, Super-A had the highest friction coefficient. Super-A had the lowest amount of wear among all metal alloys, and the amount of wear increased in the following order: Crown & Bridge, Porcelain, and Partial. Crown & Bridge had the best friction coefficient, but the hardness of Crown & Bridge was lower than that of Porcelain and Partial. Experimental measurement results indicated that the disk weight before and after the experiment was the same.

A comparative study on the correlation between Korean foods and the fractures of PFG and all ceramic crowns for posterior applications (구치용 도재소부금관과 전부도재관에 파절을 일으키는 한국음식에 관한 연구)

  • Kim, Jeong-Ho;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.156-163
    • /
    • 2009
  • Statement of problem: Recently, there have been increased esthetic needs for posterior dental restorations. The failure of posterior dental ceramic restoration are possible not only by the characters of the component materials but also by the type of food. Purpose: The research aim was to compare the in vitro fracture resistance of simulated first molar crowns fabricated using 4 dental ceramic systems, full-porcelain-occlusal-surfaced PFG, half-porcelain-occlusal-surfaced PFG, Empress 2, Ice Zirkon and selected Korean foods. Material and methods: Eighty axisymmetric crowns of each system were fabricated to fit a preparation with 1.5- to 2.0-mm occlusal reduction. The center of the occlusal surface on each of 15 specimens per ceramic system was axially loaded to fracture in a Instron 4465, and the maximum load(N) was recorded. Afterwards, selected Korean foods specimens(boiled crab, boiled chicken with bone, boiled beef rib, dried squid, dried anchovy, round candy, walnut shell) were prepared. 15 specimens per each food were placed under the Instron and the maximum fracture loads for them were recorded. The 95% confidence intervals of the characteristic failure load were compared between dental ceramic systems and Korean foods. Afterwards, on the basis of previous results, 14Hz cyclic load was applied on the 4 systems of dental ceramic restorations in MTS. The reults were analyzed by analysis of variance and Post Hoc tests. Results: 95% confidence intervals for mean of fracture load 1. full porcelain occlusal surfaced PFG Crown: 2599.3 to 2809.1 N 2. half porcelain occlusal surfaced PFG Crown: 3689.4 to 3819.8 N 3. Ice Zirkon Crown: 1501.2 to 1867.9 N 4. Empress 2 Crown: 803.2 to 1188.5 N 5. boiled crab: 294.1 to 367.9 N 6. boiled chicken with bone: 357.1 to 408.6 N 7. boiled beef rib: 4077.7 to 4356.0 N 8. dried squid: 147.5 to 190.5 N 9. dried anchovy: 35.6 to 46.5 N 10. round candy: 1900.5 to 2615.8 N 11. walnut shell: 85.7 to 373.1 N under cyclic load(14Hz) in MTS, fracture load and masticatory cycles are: 1. full porcelain occlusal surfaced PFG Crown fractured at 95% confidence intervals of 4796.8-9321.2 cycles under 2224.8 N(round candy)load, no fracture under smaller loads. 2. half porcelain occlusal surfaced PFG Crown fractured at 95% confidence intervals of 881705.1-1143565.7 cycles under 2224.8 N(round candy). no fracture under smaller loads. 3. Ice Zirkon Crown fractured at 95% confidence intervlas of 979993.0-1145773.4 cycles under 382.9 N(boiled chicken with bone). no fracture under smaller loads. 4. Empress 2 Crown fractured at 95% confidence intervals of 564.1-954.7 cycles under 382.9 N(boiled chicken with bone). no fracture under smaller loads. Conclusion: There was a significant difference in fracture resistance between experimental groups. Under single load, Korean foods than can cause fracture to the dental ceramic restorations are boiled beef rib and round candy. Even if there is no fracture under single load, cyclic dynamic load can fracture dental posterior ceramic crowns. Experimental data with 14 Hz dynamic cyclic load are obtained as follows. 1. PFG crown(full porcelain occlusion) was failed after mean 0.03 years under fracture load for round candy(2224.8 N). 2. PFG crown(half porcelain occlusion) was failed after mean 4.1 years under fracture load for round candy(2224.8 N). 3. Ice Zirkon crown was failed after mean 4.3 years under fracture load for boiled chicken with bone(382.9 N). 4. Empress 2 crown was failed after mean 0.003 years under fracture load for boiled chicken with bone(382.9 N).

Influence of Crown Margin Design on the Stress Distribution in Maxillary Canine Restored by All-Ceramic Crown: A Finite Element Analysis

  • Ozer, Zafer;Kurtoglu, Cem;Mamedov, Amirullah M.;Ozbay, Ekmel
    • Journal of Korean Dental Science
    • /
    • v.8 no.1
    • /
    • pp.28-35
    • /
    • 2015
  • Purpose: To investigate the influence of crown margin design on the stress distribution and to localize critical sites in maxillary canine under functional loading by using three dimensional finite element analysis. Materials and Methods: The bite force of 100 N, 150 N, and 200 N was applied with an angulation of $45^{\circ}$ to the longitudinal axis of tooth. Six models were restored with IPS e.max (Ivoclar Vivadent, Schaan, Liechtenstein) with a different margin design. With lingual ledge and various thicknesses, three different core ceramics were designed in each model. Result: In the core ceramic, the maximum tensile stresses were found at the labiocervical region. In the veneering ceramic the maximum tensile stresses were found at the area where the force was applied in all models. Conclusion: Shoulder and chamfer margin types are acceptable for all-ceramic rehabilitations. A ledge on the core ceramic at cervical region may affect the strength of all-ceramic crowns.

The Effect of Restorative Method on Fracture Strength and Fracture Pattern in Endodontically Treated Teeth (근관 치료 후 수복 방법이 파절 강도와 파절 양상에 미치는 영향)

  • An, Dong-Gook;Cho, In-Ho;Shin, Soo-Youn
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.2
    • /
    • pp.133-142
    • /
    • 2005
  • The purpose of this study was to evaluate interaction of restorative method according to amount of remaining clinical crown length. For the study, sixty healthy mandibular premolars with no dental caries were chosen. Specimens with clinical crown length of 1 mm, 2 mm, 3 mm above the cemento-enamel junction(CEJ) were prepared and root canal treatment was conducted using Ni-Ti rotaty files. Thirty specimens were restored with $LuxaCore^{(R)}$ and thirty were restored with casting posts. All specimens were restored with full coverage crowns and the fracture strength was teseted with the MTS universal testing marchine. The fracture pattern was observed by measuring the distance between CEJ and fracture line. From the results above, the fracture strength seems to be influenced more by amount of remaining clinical crown length than restorative method. Good prognosis could be expected, when more than 2mm of clinical crown length is retained. In the future, the further studies on restorative method, to increase fracture strength of teeth will be necessary.

A Case Report of Dental Defects in Congenital Syphilis (선천 매독성 치아기형 1예 보고)

  • 김종열;정순민
    • Journal of Oral Medicine and Pain
    • /
    • v.7 no.1
    • /
    • pp.41-46
    • /
    • 1982
  • The patient, 11 yeats old male was examined for routine oral health care. He had been hospitalized for treatment of nephritis. Hos physical condition os mental retarded & undergrowth state. In oral examination, notch on cutting edge and screw-driver shaped crown of maxillary central incisors, narrow crown and dwarfed & pinched occlusal surface of lower first molars and scars(rhagades) on the angle of the lip were shown. We diagnosed the above symptoms as dental defects of congenital syphilis; Huchinson's inscisors and mulberry molar.

  • PDF

A multidisciplinary approach to restore crown-root fractured maxillary central incisors: orthodontic extrusion and surgical extrusion (치관-치근 파절이 발생한 상악 중절치를 수복하기 위한 다각적 접근법: 교정적 정출술과 외과적 정출술)

  • Kwon, Eun-Young;Kim, So-Yeun;Jung, Kyoung-Hwa;Choi, Youn-Kyung;Kim, Hyun-Joo;Joo, Ji-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.262-271
    • /
    • 2020
  • To restore a tooth with a fracture line extending below the marginal bone level, a surgical crown lengthening procedure accompanied by ostectomy could be considered to expose the fracture line and reestablish the biologic width. However, this procedure could lead to esthetic failure, especially in the anterior teeth. Therefore, orthodontic extrusion, which elevates the fracture line from within the alveolar socket without sacrificing the supporting bone and gingiva, is recommended. This technique allows for the proper placement of the crown on a sound tooth structure, with the reestablishment of the biologic width. Alternatively, surgical extrusion is an one-step procedure that is simpler and less time-consuming than orthodontic extrusion; placing and adjusting the orthodontic appliance does not require multiple visits. This study presents successful restoration in 2 cases with a crown-tooth root fracture of the maxillary central incisor treated using a multidisciplinary approach through orthodontic extrusion or surgical extrusion followed by successful restoration.