• 제목/요약/키워드: Crown condition

검색결과 225건 처리시간 0.029초

Co-Cr-Ti 합금으로 제작한 conical telescope 외관의 변연적합도와 유지력에 관한 연구 (MARGINAL DISCREPANCY AND RETENTION FORCE OF CONICAL TELESCOPE OUTER CROWN WITH CO-CR-TI ALLOY)

  • 정희찬;정창모;전영찬;임장섭
    • 대한치과보철학회지
    • /
    • 제38권2호
    • /
    • pp.214-225
    • /
    • 2000
  • The purpose of this study was to investigate the effects of investing conditions on the marginal discrepancy of conical telescope outer crown with Co-Cr-Ti alloy(Dentitan) and to compare the marginal discrepancy and the retention force of outer crowns using different pattern materials(plastic foil, casting wax, pattern resin). To evaluate the effects of investing conditions on the marginal discrepancy, patterns with plastic foil were invested under three different liquid/powder ratio conditions using phosphate bonded investment(Univest-nonprecious): standard, 10% decreased and 10% increased. At each liquid/powder ratio condition, metal ring was lined with single or double layers of ceramic ring liner. The marginal discrepancy of outer crown at different investing conditions was measured by ${\times}100$ compact measuring microscope(STM5, Olympus, Japan). For measurement of the marginal discrepancy and the retention force of outer crown using different pattern materials, the investing condition of 10% decreased liquid/powder ratio and double layers of ring liner was selected because this investing condition resulted in the best fit of outer crown. Marginal discrepancy was measured in the same way above and retention force on universal testing machine. Under the conditions of this study, the following conclusions were drawn: 1. The thickness of ring liner had more influence on the marginal discrepancy of outer crown than the liquid/powder ratio, and the acceptable marginal fitness could not be expected at the investing condition directed by investment manufacturer 2. There were no differences in the marginal discrepancy of outer crown among three different pattern materials(P>0.05). 3. Casting wax showed the greatest retention force(1640g) of outer crown, followed by pattern resin(1110g), plastic foil(820g). However, there was no significant difference between plastic foil and pattern resin(P>0.05). 4. Plastic foil showed the least variation in marginal discrepancy and retention force.

  • PDF

乳齒(유치)에 있어서 Stainless steel crown Amalgam과 充塡(충전)과의 비교연구(比較硏究) (EVALUATION OF CONSERVATIVE TREATMENT BETWEEN AMALGAM FILLING AND STAINLESS STEEL CROWN IN PRIMARY TEETH.)

  • 우원섭
    • 대한소아치과학회지
    • /
    • 제4권1호
    • /
    • pp.35-38
    • /
    • 1977
  • The study was performed to evaluate effects of Conservative treatment between amalgam filling and stainless steel crown. The selected subjects for this study was 350 children who have amalgam filling or stainless steel crown. The obtained results are as followings. 1. In amalgam filling teeth, 120 teeth (60.0%) showed marginal leakage, 57 teeth (28.5%) showed fracture of filling material and 28 teeth (14.0%) teeth showed periapical lesion. 2. In crowned teeth, 6 teeth (3.0%) showed hole on the surface of crown, 29 teeth (14.5%) showed avulsion of crown and 10 teeth (5.0%) showed periapical lesion. 3. After 12 months from examining date, 69 teeth (34.5%) showed sound condition in amalgam filling teeth and 155 teeth (75.2%) showed sound condition in crowned teeth.

  • PDF

A study on the Development of Energy-Saving Device "Crown Duct"

  • Lee, Kwi-Joo;An, Jung-Sun;Yang, Sun-Hee
    • 한국해양공학회지
    • /
    • 제26권5호
    • /
    • pp.1-4
    • /
    • 2012
  • A energy saving device "Crown duct" has been developed and its efficiency gain has been verified experimentally in the towing tank of SSPA. The preswirl stator is well known as one of energy saving devices, which recovering the rotational energy of propeller slipstream. Crown duct has two functions of recovers the rotational energy by three blades on top of duct and of flow concentration by semi-duct. The model tests showed 4.4% efficiency gain with Crown Duct at full load condition and 6.9% at ballast condition compared with the bare hull ones for the middle class tanker.

유한요소 분석을 이용한 하중 위치에 따른 구치부 임플란트 국소의치 지지골의 응력 분포 연구 (Finite element analysis of stress distribution on supporting bone of posterior implant partial dentures by loading location)

  • 손성식;김영직;이명곤
    • 대한치과기공학회지
    • /
    • 제29권1호
    • /
    • pp.93-101
    • /
    • 2007
  • The purpose of this study is to evaluate the effect of three different oblique mechanical loading to occlusal surfaces of posterior implant partial dentures on the stress distributions in surrounding bone, using 3-dimensional finite element method. A 3-dimensional finite element model of a posterior implant partial dentures composed of three unit implants, simplified 3 gold alloy crown and supporting bone was developed according to the design of AVANA self tapping implant for this study. Three kinds of surface distributed oblique loads(300 N) are applied to following occlusal surfaces in the three crowns; 1) All occlusal surfaces in the three crown(load of 300 N was shared to three crown), 2) Occlusal surface of centered crown (load of 300 N was applied to a centered crown), 3) Occlusal surface of proximal crown(load of 300 N was applied to a distal proximal crown). In the results, 141 MPa of maximum von Mises stress was calculated at third loading condition and 98 MPa of minimum von Mises stress was calculated at first loading condition. From the results, location and type of occlusive loading conditions are important for the safety of supporting bone.

  • PDF

경기도 평택시 보호수의 생육실태와 관리방안 연구 (Analysis of Growth Condition and Some Suggestions for Its Maintenance of Legally Protected Trees Grown in Pyungtack City, Kunggi Province, Korea)

  • 이종범;두철언;이재근
    • 한국환경복원기술학회지
    • /
    • 제15권3호
    • /
    • pp.45-54
    • /
    • 2012
  • This study intended to analyze growth condition of each object by protected tree's ground for 45 places registered to Pyeongtaek protected tree list in locational characteristics, conduct exchange analysis for impediment extent rate in crown area and tree type to the result and suggest the measures to manage artificial impediment which is an effect on protected tree condition. In this study, the tree whose area of impediment for crown area is less than 21% is tree condition of grade 1~2, less than 21~50% is grade 2~3 and more than 50% is grade 3~5. The more impediment is, the more inconvenience causes on growth and development. So, it verified that the area rate must maintain less than 21% for the root system management of protected tree. For the standard of managing artificial impediment which is an effect on the tree condition of protected trees, the below matters intend to be suggested. The first, the impediment in crown area should be less than 21%. But, if there is not artificial impediment out of crown area, the rate of impediment area is considered to increase somewhat. The second, growth space of protected tree should be maintained by crown area at least and impediment should be established out of the crown area. The third, during the national project and land development, surroundings of protected tree must be applied as park, resting place, etc. and the establishment area of impediment (artificial impediment and natural impediment) in crown area must be limited. The forth, publicity for regional people (especially, land owner) is necessary for the protection of natural inheritance and the value of dependence on local government and village which are the subject of management must be announced widely through the internet media, etc, so its importance must be recognized. The fifth, the matters related to protected tree management must be able to limit artificial damage which is for surroundings of protected tree through the mutual connection among the local governments; construction, civil engineering, architecture, water and sewage, agriculture and forest and others. Also, following studies on the effects of kinds, thickness, etc. of impediment around the protected tree on trees should be continued.

유한요소법을 이용한 임플란트 고정체의 삼각배열에 따른 지지골의 응력 분석 (Finite element stress analysis on supporting bone by tripodal placement of implant fixture)

  • 손성식;이명곤
    • 대한치과기공학회지
    • /
    • 제31권1호
    • /
    • pp.7-15
    • /
    • 2009
  • Purpose: This study was to propose the clear understanding for stress distribution of supporting bone by use of staggered buccal offset tripodal placement of fixtures of posterior 3 crown implant partial dentures. We realized posterior 3 crown implant fixed partial dentures through finite element modeling and analysed stress effect of implant arrangement location to supporting bone under external load using finite element method. Method: To understand stress distribution of 3 crown implant fixed partial dentures which have 2 different arrangement by finite element analysis. In each model, for loading condition, we applied $45^{\circ}$ oblique load to occlusal surface of crown and applied 100 N for 3 crown individually(total 300 N) for imitating possible oral loading condition. at this time, we calculated Von Mises stress distribution in supporting bone through finite element method. Result: When apply $45^{\circ}$ oblique load to in-line arrangement model, maximum stress result for 100 N for each 3 crown 47.566MPa. In tripodal placement, result for 1mm buccal offset tripodal placement implant model was maximum distributed load 51.418MPa, so result was higher than in-line arrangement model. Conclusion: In stress distribution result by placement of implant fixture, the most effective structure was in-line arrangement. The tripodal placement does not effective for stress distribution, gap cause more damage to supporting bone.

  • PDF

Comparative Study between Results of Theoretical Calculation and Model Test for Performance Confirmation of "Crown Duct"

  • Lee, Kwi-Joo;An, Jung-Sun;Kwak, Han-Joung
    • 한국해양공학회지
    • /
    • 제28권1호
    • /
    • pp.1-5
    • /
    • 2014
  • Chosun University, in cooperation with SPP shipyard, has developed an energy saving device based on a new concept: "Crown Duct." Crown Duct is composed of a semi-duct with short struts inside and outside the duct. Theoretical calculations for two different designs were carried out using the CFD code "Ship Flow." The design selected from these two different forms by the CFD code analysis was tested in a towing tank at SSPA. The results showed about 4% efficiency gain under a full-load condition and about 7% gain under a ballast condition in the towing tank test.

의과적 문제가 있고 소수 잔존치를 가지는 환자에서의 치주보철 임상증례: 프릭션핀을 이용한 하이브리드 텔레스코픽 이중관법 (Periodontal prosthesis on medically compromised patient with few remaining teeth: hybrid telescopic double crown with friction pin method)

  • 하석준;이청희;조진현
    • 대한치과보철학회지
    • /
    • 제52권4호
    • /
    • pp.359-365
    • /
    • 2014
  • 치아가 얼마 남지 않은 부분 무치악 환자들에 있어 이중관(Double crown)을 이용한 치료의 성공적인 결과에 대해서 여러 문헌에서 보고 되고 있다. 이중관 가철성국소의치(Double crown removal partial denture)는 잔존치의 치주적인 상태가 좋지 않은 환자에게 치료의 대안이 될 수 있다. 이중관 가철성 국소의치는 특히 치주상태가 좋지 않고, 임플란트를 식립하기에는 의과적으로 문제가 있는 환자(Medically compromised patient)에게는 수술에 대한 부담 없이 치료할 수 있어 심리적이고 경제적인 이점이 존재한다. 본 증례에서는 상악은 다수의 치아가 잔존하여 고정성 보철물로 수복이 가능한 상태였고, 하악은 소수 잔존치만 남아있고 치주 상태가 매우 불량하여 잔존치를 이용한 클라스프 가철성 국소의치로는 수복하는 것이 거의 불가능하였다. 또한 환자는 1년 전에 하악 전치부 부위의 골수염으로 인한 수술병력으로 임플란트 식립이 어려운 상황이었다. 이러한 악조건에서 하악의 소수 잔존치를 이용한 이중관 의치는 2년이상의 기간동안 기능적, 심미적인 면에서 만족스러운 결과를 얻었기에 이를 보고하고자 한다.

상악의 소수 잔존치와 실패한 하악의 임플란트 오버덴처의 재수복 임상증례: 프릭션핀을 이용한 하이브리드 텔레스코픽 이중관법 (Hybrid telescopic double crown denture on maxillary few remaining teeth and 2 mandibular implants in case of failed implant overdenture)

  • 하석준;조진현
    • 대한치과보철학회지
    • /
    • 제54권3호
    • /
    • pp.246-252
    • /
    • 2016
  • 이중관 가철성 국소의치는 지대치 간의 이차고정(secondary splinting), 응력의 수직 방향, 지대치 지렛점(fulcrum)의 내 외관 margin 부위 위치로 인한 지렛대 길이(the length of lever arm)의 감소로 소수 잔존치이거나 지대치의 상태가 좋지 않은 경우에도 성공적으로 사용될 수 있다. 또한 이중관(double crown)을 이용한 의치는 치아가 얼마 남지 않은 부분 무치악 환자 뿐만 아니라, 소수의 임플란트를 식립한 임플란트 오버덴처에 있어서 성공적인 치료결과를 보여주고 있다. 본 증례에서는 상악은 소수 치아가 잔존했고, 하악은 치조골 흡수 및 수축이 심하고 임플란트가 실패한 상태였다. 상악의 소수 잔존치는 치주적으로 불량하였고, 하악에는 2개의 임플란트만을 다시 식립하였다. 이러한 불리한 조건에서 이중관 가철성 국소의치를 이용한 치료를 계획하였다. 1년여 정도의 관찰 기간 동안 기능적, 심미적으로 만족스러운 결과를 얻을 수 있었으며, 이중관 가철성 국소의치의 효용성을 증명하였기에 본 증례를 보고하고자 한다.

금관보철물 변연의 위치가 치은조직에 미치는 영향에 관한 임상적 연구 (A CLINICAL STUDY ON THE GINGIVAL REPSONSE TO THE LOCATION OF THE CROWN MARGIN)

  • 박순욱;장익태;김광남
    • 대한치과보철학회지
    • /
    • 제25권1호
    • /
    • pp.341-353
    • /
    • 1987
  • The purpose of this study was to investigate the gingival response to the location of the crown margin and the gingival response to the period of crown placement. Twenty one patients were selected for this study. The patients fitted into the research condition. The crown margins of anterior teeth were located at crest and supragingivally. The crown margins of posterior teeth were located at crest, subgingivally and supragingivally. Plaque index and gingival index were measured before tooth preparation and 1 week,4 weeks, 6 weeks after crown placement. The results were as follows: 1. There was no significance in the gingival response to the location of crown margin in short term period. 2. As the period of crown placement was extended, plaque index and gingival index were gradually increased. 3. Plaque index and gingival index of tooth surfaces were increased in the order of the interproximal surfaces, lingual surfaces and buccal or labial surfaces.

  • PDF