• Title/Summary/Keyword: Crown

Search Result 3,196, Processing Time 0.025 seconds

Relationships between the upper central incisor crown forms and degree of labial inclination, overbite, and overjet in Japanese young adults

  • Kurita, Takeshi;Mizuhashi, Fumi;Sato, Toshihide;Koide, Kaoru
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.6
    • /
    • pp.338-343
    • /
    • 2020
  • PURPOSE. The present study aimed to investigate the relationships between the crown form of the upper central incisor and their labial inclination, overbite, and overjet. MATERIALS AND METHODS. Maxillary and mandibular casts of 169 healthy dentitions were subjected to 3D dental scanning, and analyzed using CAD software. The crown forms were divided into tapered, square, and ovoid based on the mesiodistal dimensions at 20% of the crown height to that at 40%. The degree of labial inclination of the upper central incisor was defined as the angle between the occlusal plane and the line connecting the incisal edge and tooth cervix. The incisal edges of the right upper and lower central incisor that in contact with lines parallel to the occlusal plane were used to determine the overbite and overjet. One-way ANOVA was performed to compare the labial inclination, overbite, and overjet among the crown forms. RESULTS. The crown forms were classified into three types; crown forms with a 20%/40% dimension ratio of 1.00±0.01 were defined as square, >1.01 as tapered, and <0.99 as ovoid. The labial inclination degree was the greatest in tapered and the least in square. Both overbite and overjet in tapered and ovoid were higher than those in square. CONCLUSION. Upper central incisor crown forms were related to their labial inclination, overbite, and overjet. It was suggested that the labial inclination, overbite, and overjet should be taken into consideration for the prosthetic treatment or restoring the front teeth crowns.

The study on the Costumes in Crown Prince Chac-Rac-Do-Gam Eui-gue(책체도감의궤) and Eigt Folding Screens for Chac Rae(책체) (책체도감의궤와 책체도병에 나타난 복식에 관한연구)

  • 유송옥
    • Journal of the Korean Society of Costume
    • /
    • v.35
    • /
    • pp.265-279
    • /
    • 1997
  • Through eight folding screens for Chac Rae and ban Cha Do we have learned the costumes of people who participate in Chac Rae ceremonty being accompanied by social positions. Firstly the costumes of crown prince can be classified in two parts. One is costumes of Chac Rae befor Kwan Rae the other is costumes of Chac Rae after Kwan Rae Also we know the costumes of Chac Rae before kwan Rae is consisted of SSangdonggae Gong-jungchak Chilchangbok Mean-while the crown prince wore Myunbok at chac rae after Kwan rae. Second Chakbongdo tell us various types of Youngbok by blue-black and red colored chulik Third we can see Uijangsu who wore Sangbok on Chakbongdo and know their brilliant costume colors on ban Cha Do through Hongmo on Chunguei Chungmo on honguei Hongmo on Honguei violet-Lip on honguei mean-while Kyokun wears Hongmo on Honguei and hoimo on Hoiuei. Forth regarding the costume of Byulgam Chakbongdo appears Chogun on Hongpo belting blue belt wearing blackboots Meantime ban Cha Do shows Chogun on Hongpo wearing shoes. As reviewed above we know various color and types of costumes through Chakbongdo & Ban Cha Do on Crown prince Chacraedogam and would lide to deepen Chac Rae of crown prince including the costumes of Chac Rae of the crown princess the eldest son of the crown price the eldest brother of the king.

  • PDF

MARGINAL ADAPTATION OF THE CONICAL INNER CROWN FABRICATED WITH CAD/CAM (CAD/CAM으로 제작한 코누스내관의 변연적합)

  • Kim In-Sup;Kang Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.1
    • /
    • pp.30-41
    • /
    • 2002
  • This study was to evaluate the fabrication method and marginal adaptation of the conical inner crown fabricated with CAD/CAM. The informations on abutment teeth were transferred to a computer with a micro contact digitizer, which had a $50{\mu}m$ accuracy on the master die. A conical inner crown was designed on a computer and a real crown was machined based on this design using CAM. The marginal fit of a computer-machined conical inner crown was assessed using electron microscopy Measurement of the marginal gap between the conical inner crown and the abutment was performed on four different locations (mesial, distal, buccal, and lingual surfaces) of the finish line. The evaluation was based on 10 test specimens. The results were as follow. 1 The mean marginal gap between the conical inner crown and abutment tooth was $83.2{\pm}43{\mu}m$, 28.9% of the specimen showed marginal gap over $100{\mu}m$. 2. The fabrication method using CATRS and CAM provided clinically acceptable marginal fitness compared to conventional casting method (P<0.05).

Finite element analysis of stress distribution on supporting bone of posterior implant partial dentures by loading location (유한요소 분석을 이용한 하중 위치에 따른 구치부 임플란트 국소의치 지지골의 응력 분포 연구)

  • Son, Sung-Sik;Kim, Young-Jick;Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.29 no.1
    • /
    • pp.93-101
    • /
    • 2007
  • The purpose of this study is to evaluate the effect of three different oblique mechanical loading to occlusal surfaces of posterior implant partial dentures on the stress distributions in surrounding bone, using 3-dimensional finite element method. A 3-dimensional finite element model of a posterior implant partial dentures composed of three unit implants, simplified 3 gold alloy crown and supporting bone was developed according to the design of AVANA self tapping implant for this study. Three kinds of surface distributed oblique loads(300 N) are applied to following occlusal surfaces in the three crowns; 1) All occlusal surfaces in the three crown(load of 300 N was shared to three crown), 2) Occlusal surface of centered crown (load of 300 N was applied to a centered crown), 3) Occlusal surface of proximal crown(load of 300 N was applied to a distal proximal crown). In the results, 141 MPa of maximum von Mises stress was calculated at third loading condition and 98 MPa of minimum von Mises stress was calculated at first loading condition. From the results, location and type of occlusive loading conditions are important for the safety of supporting bone.

  • PDF

원내에서 5축 밀링기로 가공한 PMMA temporary crown의 다양한 임상적 활용

  • Suh, Sangjin
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.26 no.2
    • /
    • pp.68-83
    • /
    • 2017
  • With the increasing popularity of dental CAD / CAM, the kinds of materials that can be used and the range that can be utilized are also increasing. One of the biggest advantages of a dental CADCAM is that you can make a final prosthesis with one visit, but in case of zirconia or a complex aesthetic prosthesis, it is often difficult to make it in one day. In this case, temporary PMMA material can be used to provide a temporary crown with aesthetic and functional properties to the patient and can be used as a test crown or template for the final prosthesis. And if you are with a 5-axis milling machine in a clinic, you can make a temporary crown precisely to a large extent in a short time. In this article, various applications and clinical cases of PMMA temporary crown in the clinic will be presented.

Automatic Detection of the Middle Tooth Crown Part for Full Automatic Tooth Segmentation in Dental CT Images

  • Lee, Chan-Woo;Chae, Ok-Sam
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.3
    • /
    • pp.17-23
    • /
    • 2018
  • In this paper, we propose the automatic detection method which find the middle part of tooth crown to start individual tooth segmentation. There have been many studies on the automation of individual tooth segmentation, but there are still many problems for full automation. Detection of middle part of tooth crown used as initial information for individual tooth segmentation is closely related to performance, but most studies are based on the assumption that they are already known or they can be represented by using a straight line. In this study, we have found that the jawbone curve is similar to the tooth alignment curve by spatially analyzing the CT image, and propose a method to automatically detect the middle part of tooth crown. The proposed method successfully uses the jawbone curves to successfully create a tooth alignment curve that is difficult to detect. As the middle part of tooth crown is in the form of a tooth alignment curve, the proposed method detects the middle part of tooth crown successfully. It has also been verified by experiments that the proposed method works well on real dental CT images.

Incidence of Severe Crown Gall Disease on Tetraploid Cultivars of Grape in Korea

  • Park, Kwang-Hoon;Jeong, Kyu-Sik;Cha, Jae-Soon
    • The Plant Pathology Journal
    • /
    • v.16 no.5
    • /
    • pp.290-293
    • /
    • 2000
  • The main grape producing regions in Korea were surveyed for the occurrence and relative incidence of crown gall disease on grapevine. The results of the survey showed that the disease tended to affect tetraploid cultivars, which produce a large and sweet fruit but are very weak to cold weather. Incidence of crown gall disease was high on the tetraploid cultivars, Kyoho (Gerbong), Daebong, and Black Olympia while it was low on the diploid cultivars, Cambell Early and Sheridan. The disease incidence was very high on Anseong, Cheonan, and Chincheon, where the major growing areas of tetraploid cultivars and grapevines were burried in the winter to protect from freeze injury, whereas it was low in Yungdong, Kimcheon, and Nonsan. Crown gall disease did not increased with grapevine age on both Cambell Early and Kyoho. It remained low in Cambell Early, but high for all ages on Kyoho, Galls were found on the crown region and mid part of the trunk, but more galls were on small branches and canes on Kyoho grapevines. More than one third of ZKyoho grapevines inspected had galls on multiple locations on grapevines. On Kyoho, 56.3% of the galls covered more than 50% of the crown gall disease affects severely on the cultivar.

  • PDF

Clinical outcomes of rigid and non-rigid telescopic double-crown-retained removable dental prostheses: An analytical review

  • Seo, Jeong-Gyo;Cho, Jin-Hyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.1
    • /
    • pp.38-48
    • /
    • 2020
  • PURPOSE. The objective of this literature review was to analyze the cumulative survival rates (CSRs) of rigid and non-rigid double-crown-retained removable dental prostheses. MATERIALS AND METHODS. Screening of the literature published from January 1995 to December 2019 was performed by using electronic data base (Pubmed) and manual search. The CSRs of rigid and non-rigid double crown removable dental prostheses were investigated. RESULTS. A total of 403 articles were reviewed and 56 relevant articles of them were selected. Subsequently, 25 articles were included for data extraction. These articles were classified according to rigid and non-rigid type double crowns and further subdivided into teeth, implants, and teeth-implant combination types. The CSRs of rigid type double crown ranged from 68.9% to 95.1% of 5 to 10 years in tooth abutments, 94.02% to 100% over a 3-year mean observation periods in implant abutments, and 81.8% to 97.6% in tooth-implant combination. Non-rigid type double crowns had various CSR ranges from 34% to 94% maximum during 10 years observation in teeth abutment. The CSRs of non-rigid type had over 98% in implant abutments, and ranged from 85% to 100% in tooth-implant combination. CONCLUSION. The CSRs of double crowns varies according to types. With accurate evaluation of the remaining teeth and plan of the strategic implant placement, it could be successful treatment alternatives for partially or completely edentulous patients.

Effects of Children's Drinks on the Color Stability of Strip and Zirconia crown (어린이 음료수가 레진관과 지르코니아 기성관의 색조에 미치는 영향)

  • Jeong, Ilyong;Yi, Seoksoon;Lee, Haney;Lee, Daewoo;Yang, Yeonmi;Kim, Jaegon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.3
    • /
    • pp.306-316
    • /
    • 2017
  • The purpose of this study was to evaluate the effects of exposure to various children's drinks on the color stability of anterior primary teeth and different esthetic restorative materials clinically used in pediatric dentistry. Exfoliated maxillary primary central incisors that had been unaffected by caries were chosen as control group. Maxillary primary central incisor-shaped specimens made of strip crown and Nu-smile zirconia crowns were chosen as test groups. Polished strip resin crowns were additionally prepared to compare with unpolished strip resin crown. Each specimen and teeth were divided into 4 groups in which the test samples (n=5 each) were immersed in 4 different drinks (distilled water, cola, grape juice, jelly juice) for 6 days. In all 4 drink groups, all specimens generally showed increasing ${\Delta}E^*$ value (color difference) with time. Polished resin strip crown had higher ${\Delta}E^*$ value than the unpolished in cola, grape juice and jelly juice groups. ${\Delta}E^*$ value of zirconia crown in cola, grape juice and jelly juice groups were significantly different (p < 0.05). In conclusion, dietary control of children's drinks is required for preventing discoloration of restorative materials.

Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crown

  • Ji, Min-Kyung;Park, Ji-Hee;Park, Sang-Won;Yun, Kwi-Dug;Oh, Gye-Jeong;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.4
    • /
    • pp.271-277
    • /
    • 2015
  • PURPOSE. This study was to evaluate the marginal fit of two CAD-CAM anatomic contour zirconia crown systems compared to lithium disilicate glass-ceramic crowns. MATERIALS AND METHODS. Shoulder and deep chamfer margin were formed on each acrylic resin tooth model of a maxillary first premolar. Two CAD-CAM systems (Prettau$^{(R)}$Zirconia and ZENOSTAR$^{(R)}$ZR translucent) and lithium disilicate glass ceramic (IPS e.max$^{(R)}$press) crowns were made (n=16). Each crown was bonded to stone dies with resin cement (Rely X Unicem). Marginal gap and absolute marginal discrepancy of crowns were measured using a light microscope equipped with a digital camera (Leica DFC295) magnified by a factor of 100. Two-way analysis of variance (ANOVA) and post-hoc Tukey's HSD test were conducted to analyze the significance of crown marginal fit regarding the finish line configuration and the fabrication system. RESULTS. The mean marginal gap of lithium disilicate glass ceramic crowns (IPS e.max$^{(R)}$press) was significantly lower than that of the CAD-CAM anatomic contour zirconia crown system (Prettau$^{(R)}$Zirconia) (P<.05). Both fabrication systems and finish line configurations significantly influenced the absolute marginal discrepancy (P<.05). CONCLUSION. The lithium disilicate glass ceramic crown (IPS e.max$^{(R)}$press) had significantly smaller marginal gap than the CAD-CAM anatomic contour zirconia crown system (Prettau$^{(R)}$Zirconia). In terms of absolute marginal discrepancy, the CAD-CAM anatomic contour zirconia crown system (ZENOSTAR$^{(R)}$ZR translucent) had under-extended margin, whereas the CAD-CAM anatomic contour zirconia crown system (Prettau$^{(R)}$Zirconia) and lithium disilicate glass ceramic crowns (IPS e.max$^{(R)}$press) had overextended margins.