Crowbar 장치를 이용한 최초 단시간뇌격전류 발생기술 및 뇌격전류발생기 개발 (Development of Lightning Current Generator and Technology for Generating the First Short Stroke Lightning Current Using a Crowbar Device)

  • 엄주홍;이태형;권기량;조성철
    • 조명전기설비학회논문지
    • /
    • 제25권1호
    • /
    • pp.93-100
    • /
    • 2011
  • This paper presents a technical study for the first short stroke lightning current generator using a crowbar device. The so-called crowbar-technology is most common to make 10/350[${\mu}s$] impulse currents with high amplitude, and the lightning current generator with crowbar device has an economic advantage than the nominal RLC current generator. But both the operating efficiency and the operating reliability of crowbar spark gap are very important to design the current generator. So, the peaking circuit which consists of small capacitors and a spark gap is applied. And the multi-step coil for controlling the circuit constant at the different test conditions is used. The presented test facility is designed to perform impulse tests with amplitudes up to 50[kA] of 10/350[${\mu}s$].

고속 방전·충전 스위칭 전원차단회로 설계 제작 및 특성분석 (Implementation of crowbar circuit for high-speed discharge·charge switching and its characteristic analysis)

  • 이민웅;조성익;이남호;정상훈
    • 한국정보통신학회논문지
    • /
    • 제21권5호
    • /
    • pp.885-892
    • /
    • 2017
  • 본 논문에서는 기존 전원차단회로의 공급전원 차단 복귀 시간 지연 문제를 해결하기 위하여 고속 방전 충전 스위칭 기능을 갖는 새로운 전원차단회로를 제안하였다. 제안된 전원차단회로는 공급전원 고속 차단 후 복귀(충전) 속도를 증가시키도록 설계함으로써 전자시스템의 방사선 노출 시간과 펄스 방사선이 지나간 후 정상동작하기 위한 시간을 줄였다. 하드웨어를 구현하기 전 방전 충전 시간의 시뮬레이션은 Cadence 사의 pspice tool을 이용하여 진행하였으며 소자레벨에서 DUT(Device Under Test) 보드를 제작하였다. 전원차단회로의 비교 측정은 24V용 인공위성 전자소자를 대상으로 수행되었다. 그 결과, 제안된 회로는 기존 회로에 비하여 방전속도 96.8%, 복귀속도 27.3% 향상으로 고속 기능이 구현됨을 확인하였다.

쎄타핀치장치의 crowbar 실험에 관한 연구 (A Study on Crowbar Experiment of Theta Pinch Device)

  • 한봉석;장용무;정운관;강형부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.307-308
    • /
    • 1987
  • A low-Pressure gap decoupling crow-bar switch was designed and operated to obtain prolonged current pulses by discharging 50kJ condeser banks. And air core Rogowski coil was used for measuring high current.

  • PDF

Parameters Optimization of Impulse Generator Circuit for Generating First Short Stroke Lightning Current Waveform

  • Eom, Ju-Hong;Cho, Sung-Chul;Lee, Tae-Hyung
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.286-292
    • /
    • 2014
  • This paper presents the parameters optimization technology for generating the first short stroke lightning current waveform($10/350{\mu}s$) which is necessary for the performance tests of components of lightning protection systems, as required under IEC 62305 and the newly amended IEC 62561. The circuit using the crowbar device specified in IEC 62305 was applied to generate the lightning current waveform. To find the proper parameters of the circuit is not easy because the circuit consists of two parts; circuit I, which relates to the front of current waveform, and circuit II, which relates to the tail. A simulation in PSpise was carried out to find main factors related to the front and tail of $10/350{\mu}s$. The lightning current generator was developed by utilizing the circuit parameters found in the simulation. In the result of experiments, new parameters of the circuits need to be changed because of the difference between the simulation and the experiment results. Using the iterative method, the optimized parameters of the circuits was determined. Also a multistage-type external coil and a damping resistor were proposed to make the efficiency of generation to enhance. According to the result in this paper, an optimized first short stroke lightning current waveform was obtained.

Comparative Study between Two Protection Schemes for DFIG-based Wind Generator Fault Ride Through

  • Okedu, K.E.;Muyeen, S.M.;Takahashi, R.;Tamura, J.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권1호
    • /
    • pp.8-16
    • /
    • 2012
  • Fixed speed wind turbine generators system that uses induction generator as a wind generator has the stability problem similar to a synchronous generator. On the other hand, doubly fed induction generator (DFIG) has the flexibility to control its real and reactive powers independently while being operated in variable speed mode. This paper focuses on a scheme where IG is stabilized by using DFIG during grid fault. In that case, DFIG will be heavily stressed and a remedy should be found out to protect the frequency converter as well as to allow the independent control of real and reactive powers without loosing the synchronism. For that purpose, a crowbar protection switch or DC-link protecting device can be considered. This paper presents a comparative study between two protective schemes, a crowbar circuit connected across the rotor of the DFIG and a protective device connected in the DC-link circuit of the frequency converter. Simulation analysis by using PSCAD/EMTDC shows that both schemes could effectively protect the DFIG, but the latter scheme is superior to the former, because of less circuitry involved.