• Title/Summary/Keyword: Cross-table Analysis

Search Result 97, Processing Time 0.022 seconds

Forecasting of Seasonal Inflow to Reservoir Using Multiple Linear Regression (다중선형회귀분석에 의한 계절별 저수지 유입량 예측)

  • Kang, Jaewon
    • Journal of Environmental Science International
    • /
    • v.22 no.8
    • /
    • pp.953-963
    • /
    • 2013
  • Reliable long-term streamflow forecasting is invaluable for water resource planning and management which allocates water supply according to the demand of water users. Forecasting of seasonal inflow to Andong dam is performed and assessed using statistical methods based on hydrometeorological data. Predictors which is used to forecast seasonal inflow to Andong dam are selected from southern oscillation index, sea surface temperature, and 500 hPa geopotential height data in northern hemisphere. Predictors are selected by the following procedure. Primary predictors sets are obtained, and then final predictors are determined from the sets. The primary predictor sets for each season are identified using cross correlation and mutual information. The final predictors are identified using partial cross correlation and partial mutual information. In each season, there are three selected predictors. The values are determined using bootstrapping technique considering a specific significance level for predictor selection. Seasonal inflow forecasting is performed by multiple linear regression analysis using the selected predictors for each season, and the results of forecast using cross validation are assessed. Multiple linear regression analysis is performed using SAS. The results of multiple linear regression analysis are assessed by mean squared error and mean absolute error. And contingency table is established and assessed by Heidke skill score. The assessment reveals that the forecasts by multiple linear regression analysis are better than the reference forecasts.

Direct displacement based seismic design for single storey steel concentrically braced frames

  • Salawdeh, Suhaib;Goggins, Jamie
    • Earthquakes and Structures
    • /
    • v.10 no.5
    • /
    • pp.1125-1141
    • /
    • 2016
  • The direct displacement based design (DDBD) approach is spreading in the field of seismic design for many types of structures. This paper is carried out to present a robust approach for the DDBD procedure for single degree of freedom (SDOF) concentrically braced frames (CBFs). Special attention is paid to the choice of an equivalent viscous damping (EVD) model that represents the behaviour of a series of full scale shake table tests. The performance of the DDBD methodology of the CBFs is verified by two ways. Firstly, by comparing the DDBD results with a series of full-scale shake table tests. Secondly, by comparing the DDBD results with a quantified nonlinear time history analysis (NLTHA). It is found that the DDBD works relatively well and could predict the base shear forces ($F_b$) and the required brace cross sectional sizes of the actual values obtained from shake table tests and NLTHA. In other words, when comparing the ratio of $F_b$ estimated from the DDBD to the measured values in shake table tests, the mean and coefficient of variation ($C_V$) are found to be 1.09 and 0.12, respectively. Moreover, the mean and $C_V$ of the ratios of $F_b$ estimated from the DDBD to the values obtained from NLTHA are found to be 1.03 and 0.12, respectively. Thus, the DDBD methodology presented in this paper has been shown to give accurate and reliable results.

Seismic and collapse analysis of a UHV transmission tower-line system under cross-fault ground motions

  • Tian, Li;Bi, Wenzhe;Liu, Juncai;Dong, Xu;Xin, Aiqiang
    • Earthquakes and Structures
    • /
    • v.19 no.6
    • /
    • pp.445-457
    • /
    • 2020
  • An ultra-high voltage (UHV) transmission system has the advantages of low circuitry loss, high bulk capacity and long-distance transmission capabilities over conventional transmission systems, but it is easier for this system to cross fault rupture zones and become damaged during earthquakes. This paper experimentally and numerically investigates the seismic responses and collapse failure of a UHV transmission tower-line system crossing a fault. A 1:25 reduced-scale model is constructed and tested by using shaking tables to evaluate the influence of the forward-directivity and fling-step effects on the responses of suspension-type towers. Furthermore, the collapse failure tests of the system under specific cross-fault scenarios are carried out. The corresponding finite element (FE) model is established in ABAQUS software and verified based on the Tian-Ma-Qu material model. The results reveal that the seismic responses of the transmission system under the cross-fault scenario are larger than those under the near-fault scenario, and the permanent ground displacements in the fling-step ground motions tend to magnify the seismic responses of the fault-crossing transmission system. The critical collapse peak ground acceleration (PGA), failure mode and weak position determined by the model experiment and numerical simulation are in relatively good agreement. The sequential failure of the members in Segments 4 and 5 leads to the collapse of the entire model, whereas other segments basically remain in the intact state.

A Comparative Study on Korean Connective Morpheme '-myenseo' to the Chinese expression - based on Korean-Chinese parallel corpus (한국어 연결어미 '-면서'와 중국어 대응표현의 대조연구 -한·중 병렬 말뭉치를 기반으로)

  • YI, CHAO
    • Cross-Cultural Studies
    • /
    • v.37
    • /
    • pp.309-334
    • /
    • 2014
  • This study is based on the Korean-Chinese parallel corpus, utilizing the Korean connective morpheme '-myenseo' and contrasting with the Chinese expression. Korean learners often struggle with the use of Korean Connective Morpheme especially when there is a lexical gap between their mother language. '-myenseo' is of the most use Korean Connective Morpheme, it usually contrast to the Chinese coordinating conjunction. But according to the corpus, the contrastive Chinese expression to '-myenseo' is more than coordinating conjunction. So through this study, can help the Chinese Korean language learners learn easier while studying '-myenseo', because the variety Chinese expression are found from the parallel corpus that related to '-myenseo'. In this study, firstly discussed the semantic features and syntactic characteristics of '-myenseo'. The significant semantic features of '-myenseo' are 'simultaneous' and 'conflict'. So in this chapter the study use examples of usage to analyse the specific usage of '-myenseo'. And then this study analyse syntactic characteristics of '-myenseo' through the subject constraint, predicate constraints, temporal constraints, mood constraints, negatives constraints. then summarize them into a table. And the most important part of this study is Chapter 4. In this chapter, it contrasted the Korean connective morpheme '-myenseo' to the Chinese expression by analysing the Korean-Chinese parallel corpus. As a result of the analysis, the frequency of the Chinese expression that contrasted to '-myenseo' is summarized into

    . It can see from the table that the most common Chinese expression comparative to '-myenseo' is non-marker patterns. That means the connection of sentence in Korean can use connective morpheme what is a clarifying linguistic marker, but in Chinese it often connect the sentence by their intrinsic logical relationships. So the conclusion of this chapter is that '-myenseo' can be comparative to Chinese conjunction, expression, non-marker patterns and liberal translation patterns, which are more than Chinese conjunction that discovered before. In the last Chapter, as the conclusion part of this study, it summarized and suggest the limitations and the future research direction.

  • Plan IE Design Of Extradosed Bridge Supported by Single Plane Cables (일면지지식 Extradosed교의 계획 및 설계)

    • 이종대;이두화;권소진;김종수;손준상
      • Proceedings of the Korea Concrete Institute Conference
      • /
      • 2001.11a
      • /
      • pp.615-620
      • /
      • 2001
    • The aim of this paper is to open up a relatively new type in bridge engineering by introducing plan and design of extradosed bridge which is implemented in Sungnam-Janghowon T/K project. The topic encompasses parametric study including the behavior of the bridge relevant to the cable layout, the distance from pier table to the first cable's location, the height of pylon, the stiffness of cross section and wind vibration to ascertain sectional type of bridge and span length. For the purpose of the knowledge base presented here, the important feature of design is recommended such as modeling method, camber control, finite element analysis and heat hydration of pier table. We can verify the issue related to the characteristics of extradosed bridge as a result of study and design endeavor.

    • PDF

    Analysis of Actual Cross-Sectional Area During Scanning According to MRI Bore Size (MRI 보어 구경에 따른 검사 시 실효 단면적 분석)

    • Jeong, Hyunkeun;Jeong, Hyundo;Kim, Seongho;Jeon, Mincheol;Yoo, Sejong;Ko, Hyuncheol;Cho, Yonghyun
      • Journal of Biomedical Engineering Research
      • /
      • v.41 no.6
      • /
      • pp.219-227
      • /
      • 2020
    • In this study, we tried to quantify the actual cross-sectional area inside the bore when scanning by the MRI system with various bore sizes. To this end, a comparative analysis was conducted by both of blueprint of each MRI equipment and actual measurement in the field. As a result of analysis, ACSA(Actual Cross-Sectional Area) in Ingenia CX, Elition X, uMR 780, Omega, Vida, Lumina, Architect, Premier is recorded as 171230, 232150, 242100, 309332, 230760, 230760, 229380 and 235990 ㎟, respectively ACSA% was 60.6, 60.3, 73.0, 70.0, 60.0, 60.0, 59.6, and 61,3%. In addition, DTB (Distance from Table top to Bore top) recorded 400, 407, 445, 495, 405, 405, 405, 403, and 412 mm. Through this study, it was confirmed that there is a difference between the bore size according to each MRI system and the actual cross-sectional area during MRI scanning. Accordingly, if we consider the internal actual area just not bore size at the clinical site, useful diagnostic images can be obtained in the end with better convenience.

    Tests of integrated ceilings and the construction of simulation models

    • Lyu, Zhilun;Sakaguchi, Masakazu;Saruwatari, Tomoharu;Nagano, Yasuyuki
      • Advances in Computational Design
      • /
      • v.4 no.4
      • /
      • pp.381-395
      • /
      • 2019
    • This paper proposes a new approach to model the screw joints of integrated ceilings via the finite element method (FEM). The simulation models consist of the beam elements. The screw joints used in the main bars and cross bars and in the W bars and cross bars are assumed to be rotation springs. The stiffness of the rotation springs is defined according to the technical standards proposed by the National Institute for Land and Infrastructure Management of Japan. By comparing the results of the sheer tests and the simulation models, the effectiveness and efficiency of the simulation models proposed in this paper are verified. This paper indicates the possibility that the seismic performance of suspended ceilings can be confirmed directly via beam element models using FEM if the stiffnesses of the screw joints of the ceiling substrates are appropriately defined. Because cross-sectional shapes, physical properties, and other variables of the ceiling substrates can be easily changed in the models, it is expected that suspended ceiling manufactures will be able to design and confirm the seismic performance of suspended ceilings with different cross-sectional shapes or materials via computers, instead of spending large amounts of time and money on shake table tests.

    Deadbeat Direct Active and Reactive Power Control of Three-phase PWM AC/DC Converters

    • Gandomkar, Ali;Seok, Jul-Ki
      • Journal of Power Electronics
      • /
      • v.18 no.6
      • /
      • pp.1634-1641
      • /
      • 2018
    • This study focuses on a high-performance direct active and reactive power controller design that is successfully applicable to three-phase pulse width modulation (PWM) AC/DC converters used in renewable distributed energy generation systems. The proposed controller can overcome the sluggish transient dynamic response of conventional controllers to rapid power command changes. Desired active and reactive powers can be thoroughly obtained at the end of each PWM period through a deadbeat solution. The proposed controller achieves an exact nonlinear cross-coupling decoupling of system power without using a predefined switching table or bang/bang hysteresis control. A graphical and analytical analysis that naturally leads to a control voltage vector selection is provided to confirm the finding. The proposed control strategy is evaluated on a 3 kW PWM AC/DC converter in the simulation and experiment.

    Analytical Prediction of Heating Temperature to Manufacture Rotor with Shrink Fit for Ultra High Speed Motor According to Change Dimension of Rotor (초고속기용 열박음 로터 제작을 위한 로터의 치수에 따른 가열온도의 해석적 예측)

    • Hong, Do-Kwan;Woo, Byung-Chul;Jeong, Yeon-Ho;Koo, Dae-Hyun;Ahn, Chan-Woo
      • Transactions of the Korean Society of Mechanical Engineers A
      • /
      • v.33 no.9
      • /
      • pp.963-968
      • /
      • 2009
    • This paper deals with shrink fit analysis of rotor by 2D cross-section, 2D axis-symmetry, and 3D FEM model. And this paper presents 2nd order approximation function of thermal expansion displacement by design variables (shape dimension, heating temperature, sleeve length, interference etc.), table of orthogonal array and RSM(response surface methodology). The possibility of the rotor with shrink fit is evaluated by thermal expansion displacement. If thermal expansion displacement is larger than interference, shrink fit enable to make the rotor. 2D axis-symmetry model and 3D model are more reasonable than 2D cross-section model, because stress and strain is different along length of shaft.

    Structural Analysis of Booms and Basket in the Multi-aerial Platform (복합 굴절차의 붐과 바스켓에 대한 구조 해석)

    • So, Soo-Hyun;Kang, Sung-Soo
      • Journal of the Korean Society of Manufacturing Technology Engineers
      • /
      • v.21 no.6
      • /
      • pp.885-891
      • /
      • 2012
    • In this study, some structural analysis using 3D CAD data, material properties, load conditions and boundary conditions are carried out to evaluate structural stability of the multi-aerial platform for high-rise fire fighting and rescue. We conduct structural analysis for the upper structures such as turn table, booms and basket, by using a universal structural analysis program NASTRAN. As the results, there is local stress exceeding the yield strength, but it is able to relax stress concentration in a way such as changing thickness of the structure or making larger inertia moment in cross section of booms.


    (34141) Korea Institute of Science and Technology Information, 245, Daehak-ro, Yuseong-gu, Daejeon