• Title/Summary/Keyword: Cross-sectional geometry

Search Result 109, Processing Time 0.023 seconds

Experimental investigation on the high frequency flow-induced vibration and pressure drop of cylindrical tube bundle with plate type supporting structures (플레이트형 지지구조체로 지지된 실린더형 관 군의 고주파 유동유발진동 및 압력손실에 대한 실험적 고찰)

  • Lee, Kang-Hee;Kim, Hyung-Kyu;Yoon, Kyung-Ho;Eom, Kyong-Bo;Kim, Jin-Sun;Suh, Jung-Min
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1367-1372
    • /
    • 2008
  • A plate type supporting structure of a tube bundle in axial flow generates a certain band of a high frequency periodic excitation of a vortex shedding and/or a flow separation due to sharp edge of the plate thickness and a severe pressure drop due to a cross-sectional area of the supports. With a design consideration of the low vibration and a small flow resistance, the analysis method is uniquely confined to an experimental approach because a complex geometry of a cylindrical tube bundle and/or physical phenomena related to the fluid-structure interaction of tube bundle in a flow impede a theoretical or a numerical approach. A 5x5 cylindrical tube bundle with 5 supports which were discretely located along the bundle's axis was tested in the FIVPET hydraulic test loop for a design evaluation and an analysis perspectives. A high frequency flow-induced vibration of the supporting structures of the cylindrical tube bundle was measured at a outer surface of a supporting structure through a transparent flow housing by the laser dopper vibrometer. Pressure drop in-between three measurement distances was measured by the differential pressure transmitter. High frequency vibration and pressure drop fairly depends on the geometric design of supporting structure. So, these two parameters would be used as a qualitative design variables for design evaluation and analysis.

  • PDF

Effect of plasma oxidation time on TMR devices prepared by a ICP sputter (ICP 스퍼터를 이용한 TMR 소자 제작에서 절연막의 플라즈마 산화시간에 따른 미세구조 및 자기적 특성 변화)

  • Lee, Yeong-Min;Song, O-Seong
    • Korean Journal of Materials Research
    • /
    • v.11 no.10
    • /
    • pp.900-906
    • /
    • 2001
  • We prepared tunnel magnetoresistance(TMR) devices of Ta($50\AA$)/NiFe($50\AA$)/IrMn(150$\AA$)/CoFe($50\AA$)/Al ($13\AA$)-O/CoFe($40\AA$)/NiFe($400\AA$)/Ta(50$\AA$) structure which has 100$\times$100 $\mu\textrm{m}^2$ junction area on $2.5\Times2.5 cm^{2}$ $Si/SiO_2$ ($1000\AA$) substrates by a inductively coupled plasma(ICP) magnetron sputter. We fabricated the insulating layer using a ICP plasma oxidation method by varying oxidation time from 80 sec to 360 sec, and measured resistances and magnetoresistance(MR) ratios of TMR devices. We used a high resolution transmission electron microscope(HRTEM) to investigate microstructural evolution of insulating layer. The average resistance of devices increased from 16.38 $\Omega$ to 1018 $\Omega$ while MR ratio decreased from 30.31 %(25.18 %) to 15.01 %(14.97 %) as oxidation time increased from 80 sec to 360 sec. The values in brackets are calculated values considering geometry effect. By comparing cross-sectional TEM images of 220 sec and 360 sec-oxidation time, we found that insulating layer of 360 sec-oxidized was 30 % and 40% greater than that of 150 sec-oxidized in thickness and thickness variation, respectively. Therefore, we assumed that increase of thickness variation with oxidation time is major reason of MR decrease. The resistance of 80 sec-oxidized specimen was 160 k$\Omega$$\mu\textrm{m}^2$ which is appropriate for industrial needs of magnetic random access memory(MRAM) application.

  • PDF

Numerical and Experimental Studies on the Fluidic Characteristics and Performance of Liner-type Microtube

  • Kim, Jin Hyun;Woo, Man Ho;Kim, Dong Eok
    • Journal of Biosystems Engineering
    • /
    • v.42 no.1
    • /
    • pp.1-11
    • /
    • 2017
  • Purpose: Methods: Three-dimensional CFD modeling was conducted to analyze the flow structure and discharge flow rate corresponding to the variation in the geometry of the flow channel in a microtube. Additionally, experiments were carried out, and the discharge flow rate was measured at various inlet pressures and inclination angles of the microtube. Results: The quantitative data of velocity distribution and discharge flow rate were obtained. As the width and length of the microtip increased, the discharge flow rate decreased significantly because of the increase in the loss of pressure along the microtube. As the depth of the microtip increased, the flow rate also increased because of the reduction in the flow resistance. However, in this analysis, the variation in the angle of the microtip did not influence the flow rate. From the experimental results, it was observed that the flow rate increased linearly with the increase in the inlet pressure, and the effects of the inclination angle were not clearly observed in those test cases. The values of the flow rate obtained from the experiments were significantly lower than that obtained from the CFD analysis. This is because of the distortion of the shape of the flow path inside the microtube during the fabrication process. The distortion of the flow path might decrease the flow cross-sectional area, and it would increase the flow resistance inside the microtube. The variation in the flow rate corresponding to the variation in the inlet pressure showed similar trends. Conclusions: Therefore, the results of the numerical analysis obtained from this study can be efficiently utilized for optimizing the shape of the microtip inside a microtube.

Acoustic Rhinometric Comparison of Cleft Side with Non-cleft Side after Repair of Unilateral Cleft Lip Nose Deformity (일측 구순열비변형에서 음향비계측법(acoustic rhinometry)의 이용: 개열측과 비개열측의 비교)

  • Han, Ki Hwan;Kwon, Hyuk Joon;Kim, Hyun Ji;Kim, Jun Hyung;Son, Dae Gu
    • Archives of Plastic Surgery
    • /
    • v.33 no.1
    • /
    • pp.75-79
    • /
    • 2006
  • The upper and lower lateral cartilages provide the key to the lower cartilaginous portion of the nose. Lifting the cartilages is essential procedure for correction of unilateral cleft lip nose deformity. After correction of cleft lip nose deformity, authors used acoustic rhinometry (AR) to compare the lower nasal cavity of cleft side with non-cleft side. AR is a well known new, non-invasive diagnostic technique in which nasal geometry is assessed by means of acoustic reflection. From June 1996 to January 2004, we performed acoustic rhinometric analysis after correction of unilateral cleft lip nose deformity. This study involved 40 children of age ranged from 3 months to 8 years. Subjects were divided into the group of incomplete unilateral cleft lip nose deformity(20 subjects), and the group of complete unilateral cleft lip nose deformity(20 subjects). Results show that lower nasal cavity volume between non-cleft side and cleft side has no difference, and better results were obtained when nasal molding prong was applied at cleft side nostril. The results between incomplete type and complete type have no significant difference. In conclusion, AR is an effective method to calibrate cross sectional area and nasal cavity volume of unilateral cleft lip nose deformity, and furthermore effective in comparing the volume of cleft side with non-cleft side after unilateral cleft lip nose deformity correction with lifting the lower lateral cartilages to the upper lateral cartilages.

Screw-in forces during instrumentation by various file systems

  • Ha, Jung-Hong;Kwak, Sang Won;Kim, Sung-Kyo;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.4
    • /
    • pp.304-309
    • /
    • 2016
  • Objectives: The purpose of this study was to compare the maximum screw-in forces generated during the movement of various Nickel-Titanium (NiTi) file systems. Materials and Methods: Forty simulated canals in resin blocks were randomly divided into 4 groups for the following instruments: Mtwo size 25/0.07 (MTW, VDW GmbH), Reciproc R25 (RPR, VDW GmbH), ProTaper Universal F2 (PTU, Dentsply Maillefer), and ProTaper Next X2 (PTN, Dentsply Maillefer, n = 10). All the artificial canals were prepared to obtain a standardized lumen by using ProTaper Universal F1. Screw-in forces were measured using a custom-made experimental device (AEndoS-k, DMJ system) during instrumentation with each NiTi file system using the designated movement. The rotation speed was set at 350 rpm with an automatic 4 mm pecking motion at a speed of 1 mm/sec. The pecking depth was increased by 1 mm for each pecking motion until the file reach the working length. Forces were recorded during file movement, and the maximum force was extracted from the data. Maximum screw-in forces were analyzed by one-way ANOVA and Tukey's post hoc comparison at a significance level of 95%. Results: Reciproc and ProTaper Universal files generated the highest maximum screw-in forces among all the instruments while M-two and ProTaper Next showed the lowest (p < 0.05). Conclusions: Geometrical differences rather than shaping motion and alloys may affect the screw-in force during canal instrumentation. To reduce screw-in forces, the use of NiTi files with smaller cross-sectional area for higher flexibility is recommended.

Experimental Study of Discharge Coefficient and Cavitation for Different Nozzle Geometries (노즐 오리피스 형상에 따른 Discharge Coefficient와 Cavitation에 관한 실험적 연구)

  • Kim, Sung-Ryoul;Ku, Kun-Woo;Hong, Jung-Goo;Lee, Choong-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.10
    • /
    • pp.933-939
    • /
    • 2010
  • The purpose of this study is to investigate the generation and development of cavitation in circular and elliptical nozzles. In order to investigate the influence of cavitation, the experiment was conducted with a set of elliptical nozzles that had the same cross-sectional area, different orifice aspect ratios (a/b). Each nozzle was made of acrylic so that visualization was possible. With the injection pressure, the internal flow of the nozzle was classified into the no-cavitation, cavitation, and hydraulic-flip regions. Regardless of the nozzle geometry, with the injection pressure, the flow rate in the no-cavitation and cavitation regions increased and the discharge coefficient decreased. However, the flow rate was constant in the hydraulic-flip region. In the elliptical nozzles, the generation and development of cavitation occurred at higher cavitation number than that in the case of a circular nozzle.

Prediction of River Bed Variation using Numerical Model (수치모형을 이용한 하상변동 예측)

  • An, Sang-Jin;Yoon, Seok-Hwan;Beack, Nam-Dae
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.6
    • /
    • pp.693-701
    • /
    • 2002
  • In this study, one dimensional sediment movement numerical model(HEC-6) and semi-two dimensional sediment movement numerical model(GSTARS 2.1) were applied to solve the change of channel geometry in Bocheong stream. GSTARS 2.1 model was applied for the three selected sediment transport formulas(Ackers and White's, Engelund and Hanson, Yang formula) from 1993 to 2000 measured data on each section. The simulation results of Ackers and White formula for long -term bed changes are good when compared to the measured data. The HEC-6 model was applied for the simulation of one dimensional sediment movement for the same period. Comparison of the long-term simulations by GSTARS 2.1 and HEC-6 models with measured data shows that simulations by both models are in fair agreement with measured data in overall trend of the river bed changes. Comparisons of simulated cross sectional bed-elevations with measured data shows that GSTARS 2.1 model gives better agreement with than simulated results bed changes on the HEC-6 model.

Derivation of Channel and Floodplain Width Regression Reflecting Korean Channel Shapes in SWAT Model (국내 하천 형상을 반영한 SWAT 모형 내 하천폭 및 홍수터폭 산정 회귀식 도출)

  • Lee, Hyeon-Gu;Han, Jeongho;Lee, Dongjun;Lim, Kyoung-Jae;Kim, Jonggun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.4
    • /
    • pp.33-42
    • /
    • 2019
  • In this study, the channel and floodplain widths are indirectly measured for three different watersheds using satellite images to reflect the shape of Korean channels in the Soil and Water Assessment Tool (SWAT) model. For measuring the channel and floodplain widths, multiple satellite images were referred to ensure the widest width of certain points. In the single channel, the widths at the multiple points were measured. Based on the measured data, the regression equations were derived to estimate the channel and floodplain widths according to watershed areas. Applying these developed equations, this study evaluated the effect of the change of channel and floodplain widths on the SWAT simulation by comparing to the measured streamflow data. The developed equations estimated larger channel width and smaller floodplain compared with those calculated in the current SWAT model. As shown in the results, there was no considerable changes in the predicted streamflow using the current and developed equations. However, the flow velocity and channel depth calculated from the developed equations were smaller than those of the current equations. The differences were caused by the effect of different channel geometries used for calculating the hydraulic characteristics. The channel geometries also affected the water quality simulation in channels because the hydraulic characteristics calculated by the channel geometries are directly related to the water quality simulation. Therefore, application of the river cross-sectional regression equation reflecting the domestic stream shape is necessary for accurate water quantity / quality and water ecosystem simulation using hydrological model.

Blood Flow Simulation in Bifurcated Geometry of Abdominal and Iliac Arteries Based on CT Images (CT영상에 기반한 복부대동맥과 장골동맥 분기관 모델의 혈류유동 해석)

  • Hong Y. S.;Kim M. C.;Kang H. M.;Lee C. S.;Kim C. J.;Lee J. M.;Kim D. S.;Lee K.
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.497-503
    • /
    • 2004
  • Numerical simulation of blood flow has been conducted based on real vessel geometries generated front DICOM medical images of abdominal and iliac bifurcated arteries of a healthy man. A program was developed to read cross sectional images of the three dimensional arteries and smoothly extract boundary coordinates of vessels. Commercial programs were employed for mesh generation and flow simulation. Pressures, velocities, and flow distributions were found to lie within normal physiological ranges. Peak velocity measured in the iliac artery by ultrasound was 20% smaller than that obtained by simulation. The trend of velocity variation in a cardiac cycle was fairly similar between the simulation and the ultrasonic measurements. Simulation based on real vessel geometry of individual patient provides information on pressure, velocity, and its distribution in the diseased arteries or arteries to be surgically treated. The results of simulation may help surgeons to better understand hemodynamic status and surgical need of the patient by revealing variation of the hemodynamic parameters. Futhermore, they may serve as basic data for surgical treatment of arteries. This research is expected to develop to a program in the future that early diagnose atherosclerosis by showing distribution of a hemodynamic index closely related to atherosclerosis in arteries.

Exploring Job Aptitude through Analyzing the Relationship between Six Types of GEOPIA and MBTI's four Function Types (도형심리검사 GEOPIA 6가지 유형과 MBTI 4기능 유형 간 관계연구를 통한 직업적성탐구)

  • Oh, Mi-Ra;Choi, Jeang-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.82-92
    • /
    • 2019
  • The purpose of this study was to analyze the relationship and degree of agreement between the six types of Geometry Psychological Assessment (GEOPIA) and four functions of the Myers-Briggs Type Indicator (MBTI) personality test, and to investigate the appropriate level of vocational aptitude commonly recommended by each tool. A total of 377 adult men and women from Korea, aged between 19 and 70 years, were tested using GEOPIA and the MBTI. Cronbach's alpha was calculated to verify the validity and reliability of the measuring tools, and the mean and standard deviation of each variable were calculated. Also, a cross-sectional analysis was conducted to examine the relationship between GEOPIA and the MBTI. The results showed that Round/Triangle (RT) types, Round/Box (RB) types, Triangle/Box (TB) types and Box/Curve (BC) types among the GEOPIA personality types are highly related to MBTI's Sensing/Thinking (ST) types. GEOPIA RC types were related to Intuition/Feeling (NF) and Sensing/Feeling (SF) types, and TC types were highly related to Intuition/Thinking (NT) types. Based on the common characteristics of the two tests, the findings suggest appropriate levels of vocational aptitude. Through this research, it was confirmed that GEOPIA (a Korean psychology and personality test) can be used in counseling, coaching, and education, and above all, is a reliable tool for vocational psychological assessment to search for career aptitude.