• Title/Summary/Keyword: Cross flow response

Search Result 76, Processing Time 0.022 seconds

Instability of pipes and cables in non-homogeneous cross-flow

  • Riera, Jorge D.;Brito, J.L.V.
    • Wind and Structures
    • /
    • v.1 no.1
    • /
    • pp.59-66
    • /
    • 1998
  • The vibrations of bodies subjected to fluid flow can cause modifications in the flow conditions, giving rise to interaction forces that depend primarily on displacements and velocities of the body in question. In this paper the linearized equations of motion for bodies of arbitrary prismatic or cylindrical cross-section in two-dimensional cross-flow are presented, considering the three degrees of freedom of the body cross-section. By restraining the rotational motion, equations applicable to circular tubes, pipes or cables are obtained. These equations can be used to determine stability limits for such structural systems when subjected to non uniform cross-flow, or to evaluate, under the quasi static assumption, their response to vortex or turbulent excitation. As a simple illustration, the stability of a pipe subjected to a bidimensional flow in the direction normal to the pipe axis is examined. It is shown that the approach is extremely powerful, allowing the evaluation of fluid-structure interaction in unidimensional structural systems, such as straight or curved pipes, cables, etc, by means of either a combined experimental-numerical scheme or through purely numerical methods.

Heat Transfer Response of an Isothermal Cylinder to Fluctuating Cross Flow (맥동류에 놓인 등온 원통의 열전달 응답)

  • 권영필;이병호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.5
    • /
    • pp.706-712
    • /
    • 1986
  • The unsteay heat transfer from an isothermal circular cylinder in fluctuating cross flow is simulated numerically, for the case where the amplitude of the oscillating velocity is small compared with the mean velocity. By solving the linear perturbation equations derived from the unsteady full Navier-Stokes and the energy equations, the amplitude and the phase of heat transfer response are obtained in the range of Reynolds number R$_{3}$ < 40. The effects of the velocity, the cylinder radius and the frequency on the response are expressed graphically in terms of the normalized velocity and the cylinder radius.

Some aspects of the dynamic cross-wind response of tall industrial chimney

  • Gorski, Piotr
    • Wind and Structures
    • /
    • v.12 no.3
    • /
    • pp.259-279
    • /
    • 2009
  • The paper is concerned with the numerical study of the cross-wind response of the 295 m-tall six-flue industrial chimney, located in the power station of Belchatow, Poland. The response of the chimney due to turbulent wind flow is caused by the lateral turbulence component and vortex excitation with taking into account motion-induced wind forces. The cross-wind response has been estimated by means of the random vibration approach. Three power spectral density functions suggested by Kaimal, Tieleman and Solari for the evaluation of the lateral turbulence component response are taken into account. The vortex excitation response has been calculated by means of the Vickery and Basu's model including some complements. Motion-induced wind forces acting on a vibrating chimney have been modeled as a nonlinear aerodynamic damping force. The influence of three components mentioned above on the total cross-wind response of the chimney has been investigated. Moreover, the influence of damping ratios, evaluated by Multi-mode Random Decrement Technique, and number of mode shapes of the chimney have been examined. Computer programmes have been developed to obtain responses of the chimney. The numerical results and their comparison are presented.

Characteristics of fluctuating lift forces of a circular cylinder during generation of vortex excitation

  • Kim, Sangil;Sakamoto, Hiroshi
    • Wind and Structures
    • /
    • v.9 no.2
    • /
    • pp.109-124
    • /
    • 2006
  • This paper describes the characteristics of the fluctuating lift forces when a circular cylinder vibrates in the cross-flow direction. The response characteristics on elastically supported the circular cylinder was first examined by a free-vibration test. Next, flow-induced vibrations obtained by the free-vibration test were reproduced by a forced-vibration test, and then the characteristics of the fluctuating lift forces, the work done by the fluctuating lift, the behavior of the rolling-up of the separated shear layers were investigated on the basis of the visualized flow patterns. The main findings were that (i) the fluctuating lift forces become considerably large than those of a stationary circular cylinder, (ii) negative pressure generates on the surface of the circular cylinder when the rolling-up of separated shear layer begins, (iii) the phase between the fluctuating lift force and the cylinder displacement changes abruptly as the reduced velocity $U_r$ increases, and (iv) whether the generating cross-flow vibration becomes divergent or convergent can be described based on the work done by the fluctuating lift force. Furthermore, it was found that the generation of cross-flow vibration can be perfectly suppressed when the small tripping rods are installed on the surface of the circular cylinder.

FLUID-ELASTIC INSTABILITY OF ROTATED SQUARE TUBE ARRAY IN AN AIR-WATER TWO-PHASE CROSSFLOW

  • CHUNG HEUNG JUNE;CHU IN-CHEOL
    • Nuclear Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.69-80
    • /
    • 2006
  • Fluid-elastic instability in an air-water two-phase cross-flow has been experimentally investigated using two different arrays of straight tube bundles: normal square (NS) array and rotated square (RS) array tube bundles with the same pitch-to-diameter ratio of 1.633. Experiments have been performed over wide ranges of mass flux and void fraction. The quantitative tube vibration displacement was measured using a pair of strain gages and the detailed orbit of the tube motion was analyzed from high-speed video recordings. The present study provides the flow pattern, detailed tube vibration response, damping ratio, hydrodynamic mass, and the fluid-elastic instability for each tube bundle. Tube vibration characteristics of the RS array tube bundle in the two-phase flow condition were quite different from those of the NS array tube bundle with respect to the vortex shedding induced vibration and the shape of the oval orbit of the tube motion at the fluid-elastic instability as well as the fluid-elastic instability constant.

Mobile app Loyalty of Cross-over Shoppers: A Comparison of Korean and Chinese (한·중 크로스오버 쇼퍼들의 모바일 앱 충성도에 대한 탐색적 연구)

  • Park, Eunjoo;Jin, Gu;Park, Shinyoung
    • Fashion & Textile Research Journal
    • /
    • v.20 no.3
    • /
    • pp.293-303
    • /
    • 2018
  • Since 2009, consumers could access a new shopping channel called 'mobile shopping' with the generalization of smartphones. Mobile shopping (based on wireless communication technology), emphasizes convenience differentiated from internet shopping. A recent report introduced fashion products as powerful global drivers for mobile shopping sales. Korea and China have the highest percentage of consumer mobile shopping experiences compared to other countries. This study investigates the effects of cross-over shopping orientation, perception of app attributes, and flow on app loyalty that compared Korean and Chinese consumers. We obtained 652 usable questionnaires from two local college students; subsequently, data were analyzed by using factor analysis, Cronbach's alpha, and regression analysis using SPSS 21.0 Package. The study results showed that the cross-over shopping orientation affected perception of app attributes that included Review/Information, Design, Response and Product. Product only affected Flow, which reflected a high similarity between Korean and Chinese consumers. However, Korean and Chinese consumers showed remarkable differences in the factors related to app loyalty. Therefore, the results indicate that retailers of fashion products have developed strategies to improve mobile sales and increase the app loyalty of cross-over shopping orientation consumers.

Unsteady Flow Rate Measurement by Using Hydraulic Pipeline Dynamics (유압관로의 동특성을 이용한 비정상 유량계측)

  • 김도태
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.411-416
    • /
    • 1999
  • The measurement of unsteady flow rate is of vital importance to clarify and improve the dynamic characteristics in pipeline, hydraulic components and system. There is also demand for a real time flow sensor of ability to measure unsteady flow rate with high accuracy and fast response to realize feedback control of flow rate in fluid power systems. In this paper, we propose an approach for estimating unsteady flow rate through a pipeline and components under high pressure condition. In the method, unsteady flow rate is estimated by using hydraulic pipeline dynamics and the measured pressure values at two distant points along the pipeline. The distributed parameter model of hydraulic pipeline is applied with consideration of frequency dependent viscosity friction and unsteady velocity distribution at a cross section of a pipeline. By using the self-checking functions of the method, the validity is investigated by comparison with the measured and estimated pressure waveforms at the halfway section on the pipeline. The results show good agreement between the estimated flow rate waveforms and theroetical those under unsteady laminar flow conditions. the method proposed here is useful in estimating unsteady flow rate through an arbitray cross section in hydraulic pipeline and components without installing an instantaneous flowmeter.

  • PDF

The use of laser Doppler blood flow to assess the effect of acute administration of vitamin D on micro vascular endothelial function in people with diabetes

  • Petrofsky, Jerrold;Alshammari, Faris;Khowailed, Iman Akef;Lodha, Riya;Deshpande, Pooja;Rajaram, Praveen;Gaikwad, Mahendra;Vadera, Vidhi
    • Physical Therapy Rehabilitation Science
    • /
    • v.2 no.2
    • /
    • pp.63-69
    • /
    • 2013
  • Objective: To assess the effect of vitamin D administration on the skin blood flow response to occlusion and heat. Design: Cross-sectional study. Methods: Twenty age matched subjects; 10 who had diabetes and 10 who were controls were administered 4,000 IU of vitamin D3 for 3 weeks at breakfast. The function of the endothelial cells was evaluated in 2 ways; first, the response to 4 minutes of vascular occlusion of the skin was measured with a laser Doppler flow meter. Second, the skin blood flow response to local heat at 42 degrees C for 6 minutes was examined. Results: The results of the experiments showed that the blood flow response to heat was reduced after 3 weeks administration of vitamin D in the subjects with diabetes and in the control subjects (p<0.05). The response to occlusion was not significantly different within each group before and after vitamin D administration, but the group with diabetes had a significantly lower blood flow response to occlusion than did the controls (p<0.05). Conclusions: Acute doses of vitamin D may impair nitric oxide production and reduce blood flow to tissue during stressors in people with diabetes.

Hydrodynamic Masses of HANARO Flow Tubes (하나로 유동관의 동적유체질량)

  • 류정수;김두기
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.14 no.4
    • /
    • pp.413-422
    • /
    • 2001
  • In this study, the effect of hydrodynamic masses is investigated in the dynamic characteristics and earthquake response analyses of the submerged HANARO flow tubes. First, the consistent hydrodynamic masses of the surrounding water are obtained by finite element method. Then, modal analyses and response spectrum analyses are performed and verified by comparing the results with those measured from an experiment. Arbitrary cross-sections of submerged structures and boundary conditions of the surrounding fluid can be considered by using the general benefits of a finite element method comparing with the conventional analytical methods. Practical criteria based on parametric studies are proposed to evaluate the dynamic characteristics of HANARO flow tubes including the hydrodynamic masses.

  • PDF

An experimental study of a circular cylinder's two-degree-of-freedom motion induced by vortex

  • Kim, Shin-Woong;Lee, Seung-Jae;Park, Cheol-Young;Kang, Donghoon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.8 no.4
    • /
    • pp.330-343
    • /
    • 2016
  • This paper presents results of an experimental investigation of vortex-induced vibration (VIV) of a flexibly mounted and rigid cylinder with two-degrees-of-freedom with respect to varying ratio of in-line natural frequency to cross-flow natural frequency, $f^*$, at a fixed low mass ratio. Combined in-line and cross-flow motion was observed in a sub-critical Reynolds number range. Three-dimensional displacement meter and tension meter were used to measure dynamic responses of the model. To validate the results and the experiment system, x and y response amplitudes and ratio of oscillation frequency to cross-flow natural frequency were compared with other experimental results. It has been found that the higher harmonics, such as third and more vibration components, can occur on a certain part of steel catenary riser under a condition of dual resonance mode. In the present work, however, due to the limitation of a size of circulating water channel, the whole test of a whole configuration of the riser at an adequate scale for VIV phenomenon was not able to be conducted. Instead, we have modeled a rigid cylinder and assumed that the cylinder is a part of steel catenary riser where the higher harmonic motions could occur. Through the experiment, we have found that even though the cylinder was assumed to be rigid, the occurrence of the higher harmonic motions was observed in a small reduced velocity ($V_r$) range, where the influence of the in-line response is relatively large. The transition of the vortex shedding mode from one to another was examined by using time history of x and y directional displacement over all experimental cases. We also observed the influence of in-line restoring force power spectral density with $f^*$.