• Title/Summary/Keyword: Cross Tension Type Joint

Search Result 7, Processing Time 0.025 seconds

Fatigue Design of Various Type Spot Welded Lap Joints Using the Maximum Stress

  • Jung, Wonseok;Bae, Dongho;Sohn, Ilseon
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.106-113
    • /
    • 2004
  • Recently, a new issue in designing spot welded structures such as automobile and train car bodies is to predict an economical fatigue design criterion. One of the most typical and traditional methods is to use a ΔP-N$\sub$f/ curve. However, since the fatigue data on the ΔP-N$\sub$f/ curve vary according to the welding conditions, materials, geometry of joint and fatigue loading conditions, it is necessary to perform the additional fatigue tests for determining a new fatigue design criterion of spot-welded lap joint having specific dimension and geometry. In this study, the stress distributions around spot welds of various spot welded lap joints such as in-plane bending type (IB type), tension shea. type (TS type) and cross tension type (CT type) were numerically analyzed. Using these results, the ΔP-N$\sub$f/ curves Previously obtained from the fatigue tests for each type were rearranged into the Δ$\sigma$-N$\sub$f/ relations with the maximum stresses at the nugget edge of the spot weld.

An Experimental Study on the Static Load Capacity of T-Type Tension Joints with High Tension Bolt (고장력볼트 T-인장이음의 정적내력에 관한 실험적 연구)

  • Lee, Seung Yong;Choi, Jun Hyeok;Kim, Kyong Tae
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.1
    • /
    • pp.53-61
    • /
    • 2015
  • The tension type joint is a mechanically very efficient connection method, as it directly uses the load capacity of base metal or high tension bolt, the reduction of the number of drilling hole and fastening and the fatigue resistance. It is applied to the joint of girder and cross beam, horizontal joints of towers, beam to column joints, the secondary member joints of deck floor ends, and brackets. In this paper, static load tests for the T-type tension joint were conducted to investigate the structural behavior of the joint. The parameters were bolt diameter, flange thickness, and the reduction of clamping force of the joint. The failure modes and load capacity of joints and the effects of flange thickness, bolt diameter and clamping force were investigated.

A Study on Fatigue Design of CT-Type Spot Welded Lap Joint (CT형 점용접 이음재의 피로설계에 관한 연구)

  • Baek, Seung-Yeb
    • Journal of Welding and Joining
    • /
    • v.28 no.2
    • /
    • pp.91-95
    • /
    • 2010
  • Stress distribution and deformation on the CT-type(Cross Tension type) spot welded lap joint subjected to out of plane tensile load were investigated by finite element method. Using the maximum principal stresses at the nugget edge obtained by FEM analysis, evaluated the fatigue strength of the CT-type spot welded lap joints having various dimensions and materials. and also, the influence of the geometrical parameters of CT-type spot welded lap joints on stress distribution and fatigue strength must be evaluated. thus, in this paper, ${\Delta}P-N_f$ curve were obtained by fatigue tests. Using these results, ${\Delta}P-N_f$ curve were systematically rearranged in the $\Delta\sigma-N_f$ relation with the hot spot stresses at the CT-type spot welded lab joints. It was found that the proposed $\Delta\sigma-N_f$ relation could provide a more reasonable fatigue design criterion for the CT-type spot welded lap joints.

Optimum topology design of geometrically nonlinear suspended domes using ECBO

  • Kaveh, A.;Rezaei, M.
    • Structural Engineering and Mechanics
    • /
    • v.56 no.4
    • /
    • pp.667-694
    • /
    • 2015
  • The suspended dome system is a new structural form that has become popular in the construction of long-span roof structures. Suspended dome is a kind of new pre-stressed space grid structure that has complex mechanical characteristics. In this paper, an optimum topology design algorithm is performed using the enhanced colliding bodies optimization (ECBO) method. The length of the strut, the cable initial strain, the cross-sectional area of the cables and the cross-sectional size of steel elements are adopted as design variables and the minimum volume of each dome is taken as the objective function. The topology optimization on lamella dome is performed by considering the type of the joint connections to determine the optimum number of rings, the optimum number of joints in each ring, the optimum height of crown and tubular sections of these domes. A simple procedure is provided to determine the configuration of the dome. This procedure includes calculating the joint coordinates and steel elements and cables constructions. The design constraints are implemented according to the provision of LRFD-AISC (Load and Resistance Factor Design-American Institute of Steel Constitution). This paper explores the efficiency of lamella dome with pin-joint and rigid-joint connections and compares them to investigate the performance of these domes under wind (according to the ASCE 7-05), dead and snow loading conditions. Then, a suspended dome with pin-joint single-layer reticulated shell and a suspended dome with rigid-joint single-layer reticulated shell are discussed. Optimization is performed via ECBO algorithm to demonstrate the effectiveness and robustness of the ECBO in creating optimal design for suspended domes.

Application of Hinged Transarticular External Skeletal Fixator (HTAESF) for Proximal Tibial Physeal Fracture in a Dog (개의 근위 경골 성장판 골절에서 경첩 관절경유 외고정의 적용)

  • Kim, Kwan;Heo, Su-Young;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • v.29 no.6
    • /
    • pp.502-505
    • /
    • 2012
  • An 8-month-old, 3.5 kg intact female Toy Poodle was presented for non-weight-bearing lameness on left hindlimb. In radiological testing, left proximal tibal type II Salter-Harris physeal fracture and fibular fracture were seen. Following open reduction, the fracture was stabilized with cross-pins, tension band wires, and a hinged transarticular external skeletal fixator (HTAESF). The range of the HTAESF was increased to $25^{\circ}$ at 7 days postsurgery and to $70^{\circ}$ at 14 days post-surgery. The HTAESF was removed 3 weeks after surgery. At 6 weeks post-surgery, the fracture was successfully healed with no complications and the patient recovered a normal gait. Seven months post-surgery, the patient had a normal gait and a normal stifle joint range of motion compared to the contralateral normal limb. This is a case in which the combined use of cross-pins, tension band wires, and HTAESF was successful for treatment of a proximal tibial physeal fracture in a dog. It is thought that these methods are beneficial for stability of fracture site and recover of joint's normal range of motion through early joint movement.

Treatment of Transverse Patella Fracture with Minimally Invasive Load-Sharing Patellar Tendon Suture and Cannulated Screws (최소 침습 기법 슬개건 부하 분산 봉합술과 유관 나사못을 이용한 슬개골 횡골절의 치료)

  • Lee, Beom-Seok;Park, Byeong-Mun;Yang, Bong-Seok;Kim, Kyu-Wan
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.6
    • /
    • pp.540-545
    • /
    • 2021
  • A transverse fracture is the most common type of displaced patella fracture requiring surgery. These fractures are commonly fixed with parallel Kirschner wires or screws that cross the fracture line, often with an additional tension band. Nevertheless, conventional fixation methods of patella fractures have prevalent complications caused by the protrusion of wires or pins. These complications necessitate additional surgery for hardware removal, increase medical cost, and can limit the function of the knee joint. This paper reports cases treated with a minimally invasive load-sharing percutaneous suture of the patella tendon. The procedure provides reliable fixation for transverse patella fractures, minimizes soft tissue injuries, preserves blood flow, and reduces postoperative pain. In addition, the procedure also reduces the irritation and pain caused by the internal fixture, thereby reducing the risk of restricted knee joint movement.

Analysis of Structural Performance of Wood Composite I and Box Beam on Cross Section Component (II) - Calculation and Analysis of Ultimate Loads - (단면구성요소(斷面構成要素)에 관(關)한 목질복합(木質複合) I 및 Box형(形) 보의 구조적(構造的) 성능(性能) 분석(分析) (II) - 최대하중(最大荷重)의 계산(計算) 및 해석(解析) -)

  • Oh, Sei-Chang;Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.62-71
    • /
    • 1991
  • An evaluation of bending test of composite I and Box beams for determining the ultimate strength limit design criteria was presented. Maxium loads of composite I beams were found in beams composed of thicker upper flanges and/or vertical LVL flanges. These loads of plywood web beams were greater than those of PB web beams. Maximum loads of unsymmetrical box beams were less than those of symmetrical box beams. Thus, it took on different phase in box type beams. Ultimate loads of composite beams were greater than those of solid. The failure of composite beams were abrupt and failure mode was classified into following categories; Edgewise shear failure in web, delamination in flange-web joint, tension failure and tearing in LVL flanges, and web delamination. These failures of composite beams were appeared at the mixed mode. The influence factor affecting the performance of tested composite beams was shear strength of PB-web composite beams and compressive strength in plywood-web composite beams. It was also assumed that the influence factors on structural performance on composite beams were flange quality, web material and geometry of cross section. As one of the design methods resisting to compressive stress that was required in the case of small span to depth ratio and deep beams. composite I-beams composed of thicker upper flanges comparing to lower flanges were very effective in structural performance.

  • PDF