• Title/Summary/Keyword: Critical distance

Search Result 620, Processing Time 0.028 seconds

Estimation of a transition point of sound propagation condition using transmission loss data measured in SAVEX15 (SAVEX15 실험 해역에서 측정된 전달손실 자료를 이용한 음파 전달 조건의 변환점 추정)

  • Kwon, Hyuckjong;Choi, Jee Woong;Kim, Byoung-Nam
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.1
    • /
    • pp.1-11
    • /
    • 2018
  • Sound propagation in shallow water changes from spherical spreading to cylindrical spreading, depending on boundary conditions, and this point is defined as a transition point of the sound propagation condition. Theoretically, the transition point can be estimated using the transmission loss as a function of source-receiver range. In this paper, the transmission loss curve in a Pekeris waveguide is predicted using a parabolic-equation based acoustic propagation model and using this transmission loss curve, the range from the source of the transition point is estimated, which is compared to the critical distance calculated using the sound speed ratio of water to sediment. In addition, the effects of the sound speed profile and source depth change on the transition point are investigated. Finally, the transition point is estimated using the transmission loss data measured during the period of the SAVEX15 (Shallow Water Acoustic Variability EXperiment 2015) conducted 65 km southwest of Jeju Island in May 2015, and it is compared to the ocean environmental parameters to understand the properties of sound propagation in the experimental area.

Distributed UORA Scheme for Autonomous Train Communication in Congested Environment (자율주행 열차의 혼잡 상황 통신을 위한 분산형 UORA 기법)

  • Ahn, Woojin;Kim, Ronny Yongho
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.6
    • /
    • pp.542-547
    • /
    • 2019
  • Autonomous train is investigated to increase the capacity of railroad, and the reliability of wireless communication plays a critical role in terms of decreasing the inter-train distance. In this paper, we propose a transmission scheme for autonomous train communication in highly congested environment. The proposed scheme, namely distributed uplink orthogonal frequency division multiple access (OFDMA) random access (UORA), applies the triggered uplink access (TUA) and the UORA, introduced in the sixth generation WLAN standard, IEEE 802.11ax, for communication devices on vehicle and platform in a distributed manner. The simulation results show that the proposed scheme efficiently improves the packet transmission success rate in highly congested channel conditions compared to the conventional enhanced distributed channel access (EDCA) transmission scheme.

Development of Fiber Optic Accelerometer for Third-Party Damage Detection (타공사 감시를 위한 광섬유 가속도계의 개발)

  • Park, Ho-Rim;Choe, Jae-Bung;Kim, Yeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.10
    • /
    • pp.1551-1558
    • /
    • 2001
  • Recently, a number of underground pipelines have been drastically increased. The integrity of these buried pipelines, especially gas transmitting pipelines, is of importance due to an explosive characteristic of natural gas. The third party damage is known as one of the most critical factor which causes fatal accidents. For this reason, a number of systems detecting third party damage are under development. The major concern in the development of third party damage detection system is to transmit vibration signals out of accelerometer to signal conditioner and data acquisition system without any interference caused by noise. The objective of this paper is to develope a fiber optic accelerometer applicable to third party damage detection system. A fiber optic accelerometer was developed by use of combining principles of one degree of freedom vibration model and an extrinsic Fabry-Perot interferometer. The developed fiber optic accelerometer was designed to perform with a sensitivity of 0.06mVg, a frequency range of less than 6kHz and an amplitude range of -200g to 200g. The developed, accelerometer was compared with a piezoelectric accelerometer and calibrated. In order to verify the developed accelerometer, the field experiment was performed. From the field experiment, vibration signals and the location of impact were successfully detected. The developed accelerometer is expected to be used for the third party damage detection system which requires long distance transmission of signals.

A Prospective Analysis of Dynamic Loss of Breast Projection in Tissue Expander-Implant Reconstruction

  • Mioton, Lauren M.;Jordan, Sumanas W.;Kim, John Y.S.
    • Archives of Plastic Surgery
    • /
    • v.42 no.3
    • /
    • pp.309-315
    • /
    • 2015
  • Background Breast projection is a critical element of breast reconstruction aesthetics, but little has been published regarding breast projection as the firm expander is changed to a softer implant. Quantitative data representing this loss in projection may enhance patient education and improve our management of patient expectations. Methods Female patients who were undergoing immediate tissue-expander breast reconstruction with the senior author were enrolled in this prospective study. Three-dimensional camera software was used for all patient photographs and data analysis. Projection was calculated as the distance between the chest wall and the point of maximal projection of the breast form. Values were calculated for final tissue expander expansion and at varying intervals 3, 6, and 12 months after implant placement. Results Fourteen breasts from 12 patients were included in the final analysis. Twelve of the 14 breasts had a loss of projection at three months following the implant placement or beyond. The percentage of projection lost in these 12 breasts ranged from 6.30% to 43.4%, with an average loss of projection of 21.05%. Conclusions This study is the first prospective quantitative analysis of temporal changes in breast projection after expander-implant reconstruction. By prospectively capturing projection data with three-dimensional photographic software, we reveal a loss of projection in this population by three months post-implant exchange. These findings will not only aid in managing patient expectations, but our methodology provides a foundation for future objective studies of the breast form.

A Dose Analysis on the Ovary According to the Type of Shielding Material and the Change of Additional Filter in Radiography Using Diagnostic X-ray (진단용 X선을 이용한 방사선검사에서 차폐체 모양과 부가필터 변화에 따른 난소의 선량 분석)

  • Choi, Joon-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.429-434
    • /
    • 2019
  • The gonads are directly affected by radiation exposure during radiography of the pelvis, abdomen, and spine. Exposure of the gonads to radiation can cause genetic mutations and can result in the occurrence of malignant tumors. In this study, we created three types of shielding material shapes for shielding of the ovaries, which are the gonads of female during radiography of the pelvis, and comparative evaluations using shadow shielding methods. The source surface distance(SSD) was 100 cm and the field size was 42 cm × 43 cm. The three types of shielding material shapes(type 1, 2 and 3) were assessed and the entrance surface dose in the ovaries were measured. The thickness of the shielding material was expanded from 0.3 mm to 2.4 mm and after five repetitions, radiation values were measured and mean values were calculated. The mean dose were 3.09 mGy for type 1, 3.54 mGy for type 2, and 3.19 mGy for type 3, indicating that the measurements were the lowest for type 1. When an additional filter of 0.2 Cu + 1 Al was used, the dose were 3.72 mGy for type 1, 5.43 mGy for type 2, and 4.05 mGy for type 3, indicating that the measurements were the lowest for type 1. The results show that, even if the shielding material is not thick, in other words, even with a thickness of 2.94 mGy for the SN 3(0.9 mm) of type 1, shielding can be achieved, with a patient dose lower than the diagnostic reference level(3.42 mGy). Additionally, among the three types of shielding material, the type 1 appeared to be the most appropriate shielding material. It is thought that the use of shielding material could reduce the risk factors for stochastic effects or critical effects of ionizing radiation during pelvic or lumbar radiography.

Preparation of High $J_c$ YBCO Films on LAO by Spray Pyrolysis Process Using Nitrate Precursors (질산염 무기금속 화합물의 분무열분해법에 의한 High-$J_c$ YBCO 박막 제조)

  • Hong, Suk-Kwan;Kim, Jae-Gun;Kim, Ho-Jin;Cho, Han-Woo;Yu, Seok-Koo;Ahn, Jin-Hyun;Joo, Jin-Hoo;Lee, Hee-Gyoun;Hong, Gye-Won
    • Progress in Superconductivity
    • /
    • v.8 no.1
    • /
    • pp.71-74
    • /
    • 2006
  • High $J_c$ over 1 $MA/cm^2$ YBCO film has been successfully prepared using nitrate precursors by spray pyrolysis method. Aerosol drolpets generated using a concentric spray nozzle were directly sprayed on a $LaAlO_3$(100) single crystal substrate. The cation ratio of precursor solution was Y:Ba:Cu=1:2.65:1.35. The distance between nozzle and substrate was 15 cm. Deposition temperature was ranging from $750^{\circ}C\;to\;800^{\circ}C$. Deposition pressure was 100 Torr, and oxygen partial pressure was varied from 10 Torr to 50 Torr. The microstructure, phase formation, texture development and superconducting properties of deposited films were largely changed with oxygen partial pressure. Deposited films showed a texture with(001) planes parallel to substrate plane. High quality film was obtained when film was deposited at $760^{\circ}C$ with an oxygen partial pressure of 30 Torr. The critical current density($J_c$) of the YBCO film was 1.75 $MA/cm^2$ at 77 K and self-field.

  • PDF

Development of the Empirical Model for Estimating the Delivered Pollutant Loads Considering Geomorphic and Hydraulic Characteristics (유역형상과 수리특성을 고려한 경험론적 유달부하식 개발)

  • Park, Ji Hyoung;Kong, Dong Soo;Min, Kyung Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.913-919
    • /
    • 2007
  • This study was conducted to develop a model equation to estimate the delivered point and nonpoint pollutant loads, which are critical factor to determine the water quality of watersheds. The model equation was developed by considering various factors such as biological removal and delivered distance of pollutants, basin shape and geomorphic runoff condition. The parameters for the model equation were estimated in 3 periods, which are October to March, April to June, and July to September. As a parameter, ${\alpha}_p$, ${\alpha}_n$, ${\beta}$, a and b for $BOD_5$-delivered pollutant loads were estimated to be 0.010~0.0155, 0.051, -0.033, 0.018~0.050 and 0.93, respectively. For T-N, ${\alpha}_p$, ${\alpha}_n$, ${\beta}$ a and b were estimated to be 0.0060~0.0140, 0.014, -0.02, 0.044~0.079 and 0.93, respectively. The same parameters for T-P were estimated to be 0.0160, 0.014, -0.0250, 0.015 and 1.21, respectively. The relationship, $E^2$ (Model efficiency), between observed and calculated delivered pollutant loads showed 0.65 for $BOD_5$, 0.81 for T-N, and 0.66 for T-P, respectively. Consequently, the model equation is effective to estimate delivered pollutant loads for TMDL.

User control based OTT content search algorithms (사용자 제어기반 OTT 콘텐츠 검색 알고리즘)

  • Kim, Ki-Young;Suh, Yu-Hwa;Park, Byung-Joon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.5
    • /
    • pp.99-106
    • /
    • 2015
  • This research is focused on the development of the proprietary database embedded in the OTT device, which is used for searching and indexing video contents, and also the development of the search algorithm in the form of the critical components of the interface application with the OTT's database to provide video query searching, such as remote control smartphone application. As the number of available channels has increased to anywhere from dozens to hundreds of channels, it has become increasingly difficult for the viewer to find programs they want to watch. To address this issue, content providers are now in need of methods to recommend programs catering to each viewer's preference. the present study aims provide of the algorithm which recommends contents of OTT program by analyzing personal watching pattern based on one's history.

STM Tip Catalyzed Adsorption of Thiol Molecules and Functional Group-Selective Adsorption of a Bi-Functional Molecule Using This Catalysis

  • Min, Yeong-Hwan;Jeong, Sun-Jeong;Yun, Yeong-Sang;Park, Eun-Hui;Kim, Do-Hwan;Kim, Se-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.197-197
    • /
    • 2011
  • In this study, in contrast with cases in which Scanning Tunneling Microscopy (STM) tip-induced reactions were instigated by the tunneling electrons, the local electric field, or the mechanical force between a tip and a surface, we found that the tungsten oxide (WO3) covered tungsten (W) tip of a STM acted as a chemical catalyst for the S-H dissociative adsorption of phenylthiol and 1-octanethiol onto a Ge(100) surface. By varying the distance between the tip and the surface, the degree of the tip-catalyzed adsorption could be controlled. We have found that the thiol head-group is the critical functional group for this catalysis and the catalytic material is the WO3 layer of the tip. After removing the WO3 layer by field emission treatment, the catalytic activity of the tip has been lost. 3-mercapto isobutyric acid is a chiral bi-functional molecule which has two functional groups, carboxylic acid group and thiol group, at each end. 3-Mercapto Isobutyric Acid adsorbs at Ge(100) surface only through carboxylic acid group at room temperature and this adsorption was enhanced by the tunneling electrons between a STM tip and the surface. Using this enhancement, it is possible to make thiol group-terminated surface where we desire. On the other hand, surprisingly, the WO3 covered W tip of STM was found to act as a chemical catalyst to catalyze the adsorption of 3-mercapto isobutyric acid through thiol group at Ge(100) surface. Using this catalysis, it is possible to make carboxylic acid group-terminated surface where we want. This functional group-selective adsorption of bi-functional molecule using the catalysis may be used in positive lithographic methods to produce semiconductor substrate which is terminated by desired functional groups.

  • PDF

A STUDY ON THE ILLUMINATION OF DENTAL CLINIC (치과 진료실의 조명에 관한 실태 조사연구)

  • Choi Jong-In;Kim Yu-Lee;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.374-382
    • /
    • 2006
  • Purpose: This study was designed to investigate the present conditions of illumination techniques in dental clinics in order to contribute improvement of operating environment. This study also aimed exploring qualitative and quantitative luminous intensity required for color temperature in dental clinic illumination, which was a critical part of esthetic dentistry. Materials and methods: A total of forty-eight local dental clinics were selected for sampling a) luminous intensity, and b) color temperature. The author measured the luminous intensity and the color temperature with lux meter and color meter respectively between 12pm and 2pm. The dental unit chair placed in the general operation positions were kept the distance 60 cm then all dental units were measured three times and averaged. The author measured the luminous intensity and color temperature with both common dental operating light and then without operating light in different office environments. The study was conducted under three conditions: 1 artificial illumination in clear day light 2. artificial illumination in cloudy day light, and 3. artificial illumination alone. Results : The results obtained were as follows. 1. The average luminous intensity in dental clinic lighting was 425 lux which was not sufficient to produce the optimal shade of the patient's teeth. Furthermore, the average luminous intensity even in full operating lighting was 9532 lux which fell short of the required level of 10,000 lux. 2. The average color temperature of all dental clinics surveyed was 5169 K which met the optimal range. However, only 33.3% fell in the correct region between 5,000-5,500 K as 25% were over 5,500 K and 41.6% were below 5,000 K. As a result, 66.7% were under insufficient color temperature conditions. 3. The dental unit chair placed next to a window, hence exposure to natural lighting, had significantly higher luminous intensity and color temperature compared to the dental unit chair which didn't have a window or natural lighting. 4. The data analysis revealed that only 6.3% of the dental clinic were met the standard of the average luminous intensity and color temperature.