• Title/Summary/Keyword: Critical current

Search Result 3,048, Processing Time 0.026 seconds

Fundamental characteristic analysis on 6 T-class high-temperature superconducting no-insulation magnet using turn-distributed equivalent circuit model

  • Liu, Q.;Choia, J.;Sim, K.;Kim, S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.4
    • /
    • pp.44-48
    • /
    • 2021
  • In order to obtain ultra-high resolution MRI images, research and development of 11 T or higher superconducting magnets have been actively conducted in the world, recently. The high-temperature superconductor (HTS), first discovered in 1986, was very limited in industrial application until mid-2010, despite its high critical current characteristics in the high magnetic field compared to the low-temperature superconductor. This is because HTS magnets were unable to operate stably due to the thermal damage when a quench occurred. With the introduction of no-insulation (NI) HTS magnet winding technology that does not burn electrically, it could be expected that the HTS magnets are dramatically reduced in weight, volume, and cost. In this paper, a 6 T-class NI HTS magnet for basic characteristic analysis was designed, and a distributed equivalent circuit model of the NI coils was configured to analyze the charging current characteristics caused by excitation current, and the charge delay phenomenon and loss were predicted through the development of a simulation model. Additionally, the critical current of the NI HTS magnets was estimated, considering the magnetic field, its angle and temperature with a given current. The loss due to charging delay characteristics was analyzed and the result was shown. It is meaningful to obtain detailed operation technology to secure a stable operation protocol for a 6T NI HTS magnet which is actually manufactured.

Development of Evidence Based Clinical Practice Guideline to Improve Quality of Critical Care Nursing (중환자 간호실무 질 향상을 위한 근거중심 임상실무지침서의 개발)

  • Park, Myong-Hwa
    • Journal of Korean Critical Care Nursing
    • /
    • v.2 no.2
    • /
    • pp.68-78
    • /
    • 2009
  • Evidence based clinical practice guideline are designed to help healthcare practitioners evaluate and implement the increasing amount of evidence on best practice. Critical care area is one of the clinical sites where evidence based clinical practice guideline is needed most. This paper reviewed the definition of evidence based clinical practice guidelines, the development method of evidence based clinical practice guideline, and the current trends in guideline developing. Traditional method of guideline development is consensus based but it moves into evidence based development. Evidence based guideline is based on best available evidence and uses the strongest method to determine its effect on clinical outcomes. The current trends in guidelines is to develop the guideline at regional/national level and do subsequent modification to suit local circumstances. There is an urgent need of exploring the method of guideline development and adaptation which are appropriate for Korean clinical setting.

  • PDF

The Critical Characteristics Attributed to the Slow Cooling and Annealing Time in the Melting Growth (용융성장시 서냉시간과 후열처리시간에 따른 임계특성)

  • 임성훈;최명호;강형곤;정동철;박종광;한병성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.4
    • /
    • pp.327-333
    • /
    • 1998
  • The influence of slow cooling and annealing time in $O_2$in MPEG process on $J_c$ was investigated. From the measurement of $J_c$,SEM and XRD, it was observed that the critical current density was related with the slow cooling time and annealing time in $O_2$. The value of $J_c$ was the highest at slow cooling time of 40 hour. And also, the value of $J_c$ along the annealing time in $O_2$in the case of the slow cooling time of 40 hours was inclined to increase with annealing time. Consequently, it can be suggested that proper slow cooling time and annealing time after slow cooling in MPMG process be important to improve the critical characteristics.

  • PDF

Line-shaped superconducting NbN thin film on a silicon oxide substrate

  • Kim, Jeong-Gyun;Suh, Dongseok;Kang, Haeyong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.4
    • /
    • pp.20-25
    • /
    • 2018
  • Niobium nitride (NbN) superconducting thin films with the thickness of 100 and 400 nm have been deposited on the surfaces of silicon oxide/silicon substrates using a sputtering method. Their superconducting properties have been evaluated in terms of the transition temperature, critical magnetic field, and critical current density. In addition, the NbN films were patterned in a line with a width of $10{\mu}m$ by a reactive ion etching (RIE) process for their characterization. This study proves the applicability of the standard complementary metal-oxide-semiconductor (CMOS) process in the fabrication of superconducting thin films without considerable degradation of superconducting properties.

Simplified Calculation for Lightning Performance of Transmission Lines (송전선로뇌사고율의 간략화계산)

  • 지철근;이홍식
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.32 no.5
    • /
    • pp.170-175
    • /
    • 1983
  • A simplified method for the estimation of lightning performance of transmission Lines is described. Only one stroke current wave shape was used and the potentials of tower top and crossarms were computed at the two time points to obtain the critical stroke current for insulator flashover. Variation of the critical stroke current due to power frequency voltage was also takes into account. An applied example on 345KV Line model was shown and the calculated result was compared with the estimating curve suggested by Clayton & Young.

  • PDF

An Optimal Scheduling Method Using Probability on the Estimation of Construction Duration (확률적 공기산정에 의한 공정계획 합리화 방안)

  • Kim Sang-Joong;Lee Jae-Soeb
    • Korean Journal of Construction Engineering and Management
    • /
    • v.5 no.6 s.22
    • /
    • pp.72-79
    • /
    • 2004
  • Critical Path-based project management has been applied to the construction projects with a goal of delivering projects within original costs and time estimates. These current project management methods, rarely make early finishes of construction Projects. In addition, current practices on time management seems not to take advantages of early finishes concepts due to student syndrome and Parkinson's Law, This research study applied the Theory of Constraints(n) in the estimation of construction project duration. While the TOC includes variety of management techniques, in this study, it refers to critical chain that has been used to develop the specific management technique in scheduling. The concept of critical chain is applied to this study to solve the problems associated with the current scheduling method. The efforts focus to solve the p개blems associated with current construction project scheduling methods by adopting both stochastic estimation technique and the concept of schedule buffer,

Development of EMTDC model component for HTS power cable considering critical current, critical temperature and recovery time (임계전류, 임계온도 및 회복시간을 고려한 초전도 전력케이블의 EMTDC 모델 컴포넌트 개발)

  • Bang, Jong-Hyun;Kim, Jae-Ho;Sim, Ki-Deok;Cho, Jeon-Wook;Yoon, Jae-Young;Park, Min-Won;Yu, In-Keun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.1
    • /
    • pp.39-44
    • /
    • 2006
  • Before applying HTS power cable to the real utility. system analysis should be carried out by some simulation tools . Hereby the electrical power system analysis is very important for practical use of HTS devices. Nowadays PSCAD/EMTDC simulation tool is one of the most popular and useful analysis tool for the electrical power system analysis. Unfortunately the model component for HTS power cable is not provided in the PSCAD/EMTDC simulation tool In this paper. the EMTDC model component for HTS power cable has been developed considering critical current, critical temperature and recovery time constant that depend on the sorts of HTS wire. The numerical model of HTS Power cable in PSCAD/EMTDC was designed by using the real experimented data obtained from the real HTS 1G wire test. The utility application analysis of HTS power cable was also performed using the developed model component and the parameters of the real utility network in this study. The author's got good results. The developed model component for HTS power cable could be variously used when the power system includes HTS power cable, especially it will be readily analyzed by PSCAD/EMTDC in order to obtain the data for the level of fault current power flow, and power losses, and so on.

Inundation Analysis of Agricultural Basin Considering Agricultural Drainage Hydrological Plan and Critical Rainfall Duration (농지배수 수문설계 기준과 임계지속기간을 고려한 농업 소유역 침수분석)

  • Kim, Kwihoon;Jun, Sang-Min;Kang, Moon Seong;Choi, Jin-Yong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.4
    • /
    • pp.25-32
    • /
    • 2023
  • KDS (Korean Design Standard) for agricultural drainage is a planning standard that helps determine the appropriate capacity and type of drainage facilities. The objective of this study was to analyze the inundation of the agricultural basin considering the current design standard and the critical rainfall duration. This study used the rainfall durations of 1-48 hour, and the time distribution method with the Chicago and the modified Huff model. For the runoff model, the NRCS (Natural Resources Conservation Service) unit hydrograph method was applied, and the inundation depth and duration were analyzed using area-elevation data. From the inundation analysis using the modified Huff method with different rainfall durations, 4 hours showed the largest peak discharge, and 11 hours showed the largest inundation depth. From the comparison analysis with the current method (Chicago method with a duration of 48 hours) and the modified Huff method applying critical rainfall duration, the current method showed less peak discharge and lower inundation depth compared to the modified Huff method. From the simulation of changing values of drainage rate, the duration of 11 hours showed larger inundation depth and duration compared to the duration of 4 hours. Accordingly, the modified Huff method with the critical rainfall duration would likely be a safer design than the current method. Also, a process of choosing a design hydrograph considering the inundation depth and duration is needed to apply the critical rainfall duration. This study is expected to be helpful for the theoretical basis of the agricultural drainage design standards.

A Study on Empowerment and Critical Thinking of the 1st Emergency Medical Technician (1급 응급구조사의 임파워먼트와 비판적 사고성향에 관한 연구)

  • Park, Dae-Sung;Kim, Eun-Ju
    • The Korean Journal of Emergency Medical Services
    • /
    • v.10 no.3
    • /
    • pp.5-20
    • /
    • 2006
  • Purpose: This study examines the degree of empowerment recognized by the 1st paramedics and the trend of their critical thinking, analyzes correlations between empowerment and critical thinking to reveal whether there is statistically significant difference between them and then is to provide basic materials necessary for research on empowerment and critical thinking. Method: This study distributes 105 structured self-report questionnaires to the 1st emergency medical technicians working at fire fighting police boxes, general hospitals, clinics and emergency medical information centers in G Metropolitan City and J province from April 29 to May 28, 2006, collects their responses directly and analyzes results with t-test, F-test(ANOVA) and Pearson's Correlation Coefficient. Result: 1. First, average score of empowerment of subjects was 4.68 out of 6 and according to scores by area, capacity 5.98 was highest, followed by significance 5.41, self- determination 4.44 and effectiveness 3.79. 2. degree of empowerment according to general characteristics of subjects showed statistically significant differences in final education(F=2.714, p= .049), level of salary (F=3.298, p= .014) and satisfaction of current job (F=5.399, p= .001). 3. average score of critical thinking of subjects was 3.28 out of 7 and according to areas, no bias 3.95 was highest, followed by maturity 3.68, structure 3.35, inquisitiveness 3.11, pursuit of truth 3.07, critical thinking and self-confidence 3.00, analyticity 2.98. 4. degree of critical thinking by general characteristics of subjects showed statistically significant differences in age(F=2.577, p= .041), final education (F=7.877, p= .000), current workplace (F=3.513, p= .018), level of salary(F=4.628, p= .002), satisfaction with current job(F=6.879, p= .000) and intention to transfer current job(t=15.21, p=.000). 5. as a result of correlations between empowerment and critical thinking of subjects, Pearson correlation coefficients between whole empowerment and critical thinking were r= .21, p=.013. Conclusion: It is considered that the 1st paramedic managers must seek how to keep and manage empowerment and development of education and training program which can enhance critical thinking is needed. Further, emergency educators must develop educational program based on the concept of empowerment to establish early awareness of a desirable organization culture and increase understanding of empowerment in the process of education.

  • PDF