• Title/Summary/Keyword: Critical current

Search Result 3,048, Processing Time 0.03 seconds

Critical current and AC loss characteristic of Coated Conductor under bending (Coated Conductor의 굽힘변형에 따른 임계전류 및 교류손실 특성)

  • Kim, Hae-Joon;Sim, Ki-Deok;Kim, Seok-Ho;Cho, Jeon-Wook;Jang, H.M.;Lee, S.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.3
    • /
    • pp.23-26
    • /
    • 2008
  • Constructions of coated conductor which is differently from Bi-2223 is comprised multiple coatings on a base material or substrate and designed to achieve the highest degree of alignment possibility of the atoms in the superconductor material. In this study, we are measured and analyzed degradations of critical current according to diameter. In addition to study the effects of bending strain, we observed the AC loss of coated conductor and carried out analytical study for relation between Ic degradation and AC loss as well. The measurement of AC loss and numerical calculation was carried out based on Norris theory to compare with experimental results. The relationship between critical current and AC loss of HTS tapes with partial deformation by mechanical stress was studied. These results will amount the most important basis data in the of HTS cable, magnet, etc that winding work is required.

A Study on the DC Critical Current Test Method for 22.9kV/50MV A Superconducting Power Cable Considering the Uncertainty (불확도를 고려한 22.9kV, 50MVA급 초전도 전력케이블의 직류 임계전류 측정방법에 관한 연구)

  • Choi, S.J.;Lee, S.J.;Sim, K.D.;Cho, J.W.;Lee, S.K.;Yang, B.M.;Ko, T.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.46-49
    • /
    • 2009
  • A 3-phase 100m long, 22.9kV class HTS power transmission cable system was developed by Korea Electrotechnology Research Institute (KERI) and LS cable Ltd. those are participated in the 21st Century Frontier project R&D Program of Korea. It is important to test the DC critical current related with its power capacity before applying to the real power grid. In 1995, several international standards organizations including International Electrotechnical Commission (IEC), decided to unify the use of statistical terms related with 'accuracy' or 'precision' in their standards. It was decided to use the word 'uncertainty' for all quantitative (associated with a number) statistical expressions. In this paper, we measured DC critical current of 22.9kV/50MVA superconducting power cable with several voltage tap and analyzed the uncertainty with these results.

Optimized LCL filter Design Method of Utility Interactive Inverter (계통연계형 인버터의 LCL필터 최적 설계기법)

  • Jung, Sang-Hyuk;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.103-109
    • /
    • 2013
  • The conventional LCL filter design method of the utility interactive inverter considers only harmonics attenuation of the current injected to the grid. However, in case of utility-interactive inverter with critical load the voltage quality of the critical load should also be considered for LCL filter design. Also, considering cost and volume of LCL filters. it is important to have minimum values of inductance and capacitance as far as the harmonic standards are satisfied. In this paper a LCL filter design method is proposed to satisfy not only the harmonic standards of the grid current during the grid-connected mode but the voltage quality of the critical load during grid-connected mode and stand-alone mode. With the proposed method optimized values of LCL filters could be obtained by applying weighting factor to voltage ripple across the critical load, inductor volume, amount of reactive current and system bandwidth.

Effect of Heat Treatment on Superconducting Properties on Bi2212/Ag Wire (Bi2212/Ag 선재의 초전도 특성에 대한 열처리의 영향)

  • Kim, S.C.;Ha, D.W.;Song, K.J.;Oh, S.S.;Lee, N.J.;Han, I.Y.;Oh, J.G.;Sohn, H.S.
    • Progress in Superconductivity
    • /
    • v.8 no.1
    • /
    • pp.54-58
    • /
    • 2006
  • We have fabricated double stacked 385 filamentary Bi2212/Ag round wires which have different Ag ratios. The wires have been heat-treated at the maximum temperature($T_{max}$) of $882{\sim}896^{\circ}C$ for 0.5 h. Effect of heat treatment on critical current density and critical temperature on Bi2212/Ag round wires has been studied. Critical current density of the wire heat -treated at $890^{\circ}C$ showed 206,250 $A/cm^2$ at 4.2 K, 0 T and critical temperature of the wire was 83 K. Microstructure of the wires also has been studied via optical microscopy and SEM.

  • PDF

Flux pinning and critical current density in $TiO_2$-doped $MgB_2$ superconductor

  • Gang, Ji-Hun;Park, Jeong-Su;Park, Jin-U;Lee, Yeong-Baek;Prokhorov, V.G.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.172-172
    • /
    • 2010
  • $MgB_2$ doped with $TiO_2$ was prepared by the in-situ solid state reaction to study the effects of $TiO_2$ dopant on the flux pinning behavior of $MgB_2$ superconductor. From the field-cooled and the zero-field-cooled temperature dependences of magnetization, the realms of vortex-glass and vortex-liquid states of $TiO_2$-doped $MgB_2$ were determined in the H-T diagram (the temperature dependence of upper critical magnetic field and irreversibility line). The critical current density was estimated from the width of hysteresis loops in the framework of Beam's model at different temperatures. The results indicate that nano-scale $TiO_2$ inclusions play a role of the effective pinning centers and lead to the enhanced upper critical field and critical current density. It is suggested that the grain-boundary pinning mechanism is realized in $TiO_2$-doped $MgB_2$ superconductor.

  • PDF

Investigation on Effective Operational Temperature of HTS Cable System considering Critical Current and AC loss

  • Kim, Tae-Min;Yim, Seong-Woo;Sohn, Song-Ho;Lim, Ji-Hyun;Han, Sang-Chul;Ryu, Kyung-Woo;Yang, Hyung-Suk
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.307-310
    • /
    • 2016
  • The operational cost for maintaining the superconductivity of high-temperature superconducting (HTS) cables needs to be reduced for feasible operation. It depends on factors such as AC loss and heat transfer from the outside. Effective operation requires design optimization and suitable operational conditions. Generally, it is known that critical currents increase and AC losses decrease as the operational temperature of liquid nitrogen ($LN_2$) is lowered. However, the cryo-cooler consumes more power to lower the temperature. To determine the effective operational temperature of the HTS cable while considering the critical current and AC loss, critical currents of the HTS cable conductor were measured under various temperature conditions using sub-cooled $LN_2$ by Stirling cryo-cooler. Next, AC losses were measured under the same conditions and their variations were analyzed. We used the results to select suitable operating conditions while considering the cryo-cooler's power consumption. We then recommended the effective operating temperature for the HTS cable system installed in an actual power grid in KEPCO's 154/22.9 kV transformer substation.

Determination of Critical Chloride Content of Ordinary Portland Cement Concrete by Linear Polarization Technique (선형분극법을 이용한 보통프틀랜드시멘트 콘크리트의 임계염화물량)

  • Kim, Hong-Sam;Cheong, Hai-Moon;Ahn, Tae-Song
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.9
    • /
    • pp.524-528
    • /
    • 2007
  • The results of evaluating steel corrosion in concrete containing chloride content of various levels indicated that the more chloride content in concrete leads to the lower potential and higher corrosion current density. However, the open circuit potential of steel varied with time and exposure condition, and the corelation between the open circuit potential and corrosion current density was not obvious. In order to determine the critical threshold content of chloride of steel corrosion in concrete, the concept of average corrosion current density was employed. The range of critical chloride content in portland cement concretes was about $1.56{\sim}1.77%$($Cl^-$, %, wt of cement content) along with water-cement ratio, and higher water-cement ratio resulted in reduction in critical threshold chloride content.

Analysis on Current Distribution in Bi-2223/Ag Tapes with Applied Alternating Over-critical Current

  • Yim, Seong-Woo;Kim, Hye-Rim;Hwang, Si-Dole
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.6
    • /
    • pp.678-682
    • /
    • 2004
  • Generally Bi-2223/Ag tapes have a broad S/N transition region and their sheath is a good electric conductor. In this study, the current distribution between superconductor and metal sheath in HTS tapes were investigated. AC with its peak value above 10 times $I_{c}$ was applied to HTS tapes for around 6 cycles and V-I characteristics were measured. Using the resistance of the sheath and V-I curves, the current distribution between superconductor and metal sheath was calculated. When 150 $A_{p}$ was applied, more than 2/3 of the current flows through superconductor. However, in the case of 304 $A_{p}$, most of the applied current came to flow through the metal sheath at the 6th cycle.e.e.e.

Stability characteristics of DyBCO coated conductor stabilized with stainless steel

  • Dixit, Manglesh;Kim, Tae-Hyung;Oh, Sang-Soo;Song, Kyu-Jeong;Kim, Ho-Min;Park, Kwon-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.288-289
    • /
    • 2005
  • As high temperature superconductor applications became a reality due to increase in coated conductor performance, it is important to understand their stability behavior to design safe electrical power systems. We have experimentally studied the dependence of quench and recovery characteristics of coated conductors on the amplitude of current and duration time. The sample used in the present study is stabilized with stainless steel. Stability tests of 3 cm long sample were performed in a liquid nitrogen bath cooling condition by applying a short period over current pulses for 50 and 100 ms, with amplitude up to ~ 6 times of the critical current. The transport current that follows before and after the current pulse was fixed about ~85% the critical current. We analyzed the quench recovery using the current voltage characteristic.

  • PDF

안정화 층에 따른 YBCO 박막형 선재의 통전 특성에 관한 연구

  • Du, Ho-Ik;Kim, Min-Ju;Kim, Yong-Jin;Lee, Dong-Hyeok;Han, Byeong-Seong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.214-214
    • /
    • 2009
  • While critical properties of BSCCO wires rely considerably on grid direction upon BSCCO and have very complicated mechanism of generating a superconducting phase, making it difficult to improve properties of wires, YBCO thin-film wires which can be formed in a superconducting phase upon metal board through vapor deposition processing can get excellent direction and reduce manufacturing costs with more flexibility in improving critical properties; thus, they will be suitable for instrument application in the future. Contrary to BSCCO wires for which thick silver alloy covering materials should inevitably be used, moreover, YBCO thin-film wires have an advantage of making thickness and quality of covering materials different by usage. Such a property can be an important element to widen application of wires by presenting possibility of using thin-film wires as superconducting material for fault current limiter as well as for high power current application. In this study we intend to prepare YBCO thin-film wires with different stabilizer layers to analyze current application and current restriction properties by stabilizer layers on the basis of detailed researches on changes in current classification properties below critical value.

  • PDF