• Title/Summary/Keyword: Critical Condition

Search Result 2,005, Processing Time 0.035 seconds

Massive Hemoptysis Cases Intubated with the Univent$^{(R)}$ Bronchial Blocker for Lung Protection (건측 폐보호를 위해 Univent$^{(R)}$튜브를 사용한 대량객혈환자의 증례)

  • Moon, Jae-Young;Lee, Young-Seok;Lyu, Ji-Won;Huh, Jin-Won;Hong, Sang-Bum;Kim, Sang-We;Lim, Chae-Man;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.72 no.2
    • /
    • pp.212-217
    • /
    • 2012
  • Massive hemoptysis is a life-threatening condition and sometimes leads to death due to airway obstruction rather than exsanguinations. In a critical hemoptysis, endotracheal intubation may be necessary to maintain adequate gas exchange and protect the unaffected side of the lung. Bronchial blockers (BBs), commonly used technique for one-lung ventilation in thoracic or cardiac surgeries, are valuable devices for protecting the airway in massive endobronchial bleeding. We report three cases intubated with BBs, Univent$^{(R)}$, in massive hemoptysis. We suggest that BBs are one of the indispensable equipments for respiratory specialized wards and intensive care units.

Evaluation of Critical Pressure Ratios Sonic Nozzle at Low Reynolds Numbers (음속 노즐의 임계 압력비에 대한 저 레이놀즈수의 영향)

  • Choe, Yong-Mun;Park, Gyeong-Am;Cha, Ji-Seon;Choe, Hae-Man;Yun, Bok-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.11
    • /
    • pp.1535-1539
    • /
    • 2000
  • A sonic nozzle is used as a reference flow meter in the area of gas flow rate measurement. The critical pressure ratio of sonic nozzle is an important factor in maintaining its operating condition. ISO9300 suggested the critical pressure ratio of sonic nozzle as a function of area ratio. In this study, 13 sonic nozzles were made by the design of ISC9300 with different half diffuser angles of 2。 to 8。 and throat diameters of 0.28 to 4.48 mm. The test results of half diffuser angles below 8。 ar quite similar to those of ISO9300. On the other hand, the critical pressure ratio for the nozzle of 8。 decreases by 5.5% in comparison with ISO9300. However, ISO9300 does not predict the critical pressure ratio at lower Reynolds numbers than 10(sup)5. Therefore, it is found that it is a better way for the flow of low Reynolds number to express the critical pressure ratio of sonic nozzle as a function of Reynolds number than area ratios. A correlation equation of critical pressure is introduced with uncertainty $\pm$3.2 % at 95% confidence level.

Pneumatosis Intestinalis Complicated by Pneumoperitoneum in a Patient with Asthma

  • Choi, Joon Young;Cho, Sung Bae;Kim, Hyun Ho;Lee, In Hee;Lee, Hea Yon;Kang, Hye Seon;Lee, Hwa Young;Lee, Sook Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.77 no.5
    • /
    • pp.219-222
    • /
    • 2014
  • Pneumatosis intestinalis (PI) is a very rare condition that is defined as the presence of gas within the subserosal or submucosal layer of the bowel. PI has been described in association with a variety of conditions including gastrointestinal tract disorders, pulmonary diseases, connective tissue disorders, organ transplantation, leukemia, and various immunodeficiency states. We report a rare case of a 74-year-old woman who complained of dyspnea during the management of acute asthma exacerbation and developed PI; but, it improved without any treatment.

Critical Heat Flux in Uniformly Heated Rod Bundle Under Wide Range of System Pressures (광범위한 압력조건하에서 균일 가열 수직 봉다발에서의 임계열유속)

  • Moon, Sang-Ki;Chun, Se-Young;Choi, Ki-Yong
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.195-200
    • /
    • 2001
  • An experimental study on critical heat flux (CHF) has been performed for water flow in a uniformly heated vertical 3 by 3 rod bundle under low flow and a wide range of pressure conditions. The objective of this study is to investigate the parametric trends of CHF with 3 by 3 rod bundle test section where three unheated rods exist. The general trends of the CHF are coincident with previous understandings. At low flow and system pressure above 3 MPa, some critical qualities are larger than 1.0 due to counter-current flow in test sections. Since there is a supply of water to the heated section from unheated section, the maximum CHFs at system pressure between 2 and 4 MPa are not shown.

  • PDF

Over critical current characteristics of HTS tapes (고온초전도 선재의 과전류 통전 특성)

  • 임성우;황시돌;최용선;최효상;현옥배;유재무
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.241-244
    • /
    • 2002
  • We investigated over critical current characteristics of HTS tapes fabricated by KIMM. The critical current (Ic) of the HTS tapes was 68A/cm. In order to acquire over current I-V characteristics of HTS tapes, we applied AC that is 2-7 times of Ic to these tapes. When applied AC whose peak value is twice of Ic, we found out that total resistance of HTS tapes aid not change. In case of 3 times of Ic, resistances of HTS tapes began to increase slowly. However, superconducting regions of them were maintained stably in this condition. In addition, 280 $A_{peak}$was applied, superconducting regions began to be decreased gradually. Finally, 0.62m$\Omega$ of resistance was measured in HTS tapes which was applied AC correspond to 7 times of Ic at first cycle.

  • PDF

Shape Optimization to Improve the Critical Current of HTS Solenoid (고온초전도 솔레노이드의 임계전류 향상을 위한 형상 최적화)

  • 강준선;이준호;나완수;박일한;권영길;손명환;김석환
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.274-276
    • /
    • 2002
  • To enhance the critical current of superconducting coil, the magnetic field experienced by superconductors in a coil should be minimized. This is true for both low $T_{c}$ and high $T_{c}$ superconductors, and the difference between the two lays in their isotropic/an-isotropic characteristics. In this paper, we propose a shape optimization algorithm to reduce radial magnetic field components in HTS solenoid to enhance the critical current of a solenoid. In the algorithm, finite element method and continuum shape design sensitivity formula were employed. The objective function is to minimize the maximum radial magnetic fields in a solenoid with a constraint of constant solenoid volume condition. In this paper, the details on algorithm are introduced and the calculated optimized shapes are presented.

  • PDF

Lung Regeneration Therapy for Chronic Obstructive Pulmonary Disease

  • Oh, Dong Kyu;Kim, You-Sun;Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.80 no.1
    • /
    • pp.1-10
    • /
    • 2017
  • Chronic obstructive pulmonary disease (COPD) is a critical condition with high morbidity and mortality. Although several medications are available, there are no definite treatments. However, recent advances in the understanding of stem and progenitor cells in the lung, and molecular changes during re-alveolization after pneumonectomy, have made it possible to envisage the regeneration of damaged lungs. With this background, numerous studies of stem cells and various stimulatory molecules have been undertaken, to try and regenerate destroyed lungs in animal models of COPD. Both the cell and drug therapies show promising results. However, in contrast to the successes in laboratories, no clinical trials have exhibited satisfactory efficacy, although they were generally safe and tolerable. In this article, we review the previous experimental and clinical trials, and summarize the recent advances in lung regeneration therapy for COPD. Furthermore, we discuss the current limitations and future perspectives of this emerging field.

An experimental study on the evaporation of paraffin family fuel droplet under high temperature and high pressure (고온 고압기류중을 비행하는 파라핀계 연료액적의 증발에 관한 연구)

  • ;川口修
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.2125-2131
    • /
    • 1991
  • Evaporation rate constant, obtained by in this experimental study, of freely falling liquid fuel droplet on the condition of hot and pressurized environment are converted to critical evaporation constant according to Eq. of Ranz and Marshall. Critical evaporation constant, on constant environment pressuire, actively increase almost linearly with environment temperature increasing, but, on constant temperature, increases more or less with pressure increasing. Multycomponent droplet mixed with the fine fuel having a different of boiling point evaporate in order to boiling point, and each evaporation rate constant of mixed fuel equal to each fuel.

Effect of Geometrical Discontinuity on Ductile Fracture Initiation Behavior under Static Leading

  • An, G.B.;Ohata, M.;Toyoda, M.
    • International Journal of Korean Welding Society
    • /
    • v.3 no.1
    • /
    • pp.51-56
    • /
    • 2003
  • It is important to evaluate the fracture initiation behaviors of steel structure. It has been well known that the ductile cracking of steel would be accelerated by triaxial stress state. Recently, the characteristics of critical crack initiation of steels are quantitatively estimated using the two-parameters, that is, equivalent plastic strain and stress triaxiality, criterion. This study is paid to the fundamental clarification of the effect of notch radius, which can elevate plastic constraint due to heterogeneous plastic straining on critical condition to initiate ductile crack using two-parameters. Hense, the crack initiation testing were conducted under static loading using round bar specimens with circumferential notch. To evaluate the stress/strain state in the specimens was used thermal elastic-plastic FE-analysis. The result showed that equivalent plastic strain to initiate ductile crack expressed as a function of stress triaxiality obtained from the homogeneous specimens with circumferential notched under static loading. And it was evaluated that by using this two-parameters criterion, the critical crack initiation of homogeneous specimens under static loading.

  • PDF

Design of Accelerated Degradation Test with Tightened Critical Values under Random Coefficient Degradation Rate Model (확률계수 열화율 모형하에서 판정가속을 도입한 가속열화시험의 설계)

  • Cho, You-hee;Seo, Sun-keun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.34 no.1
    • /
    • pp.23-31
    • /
    • 2008
  • This paper presents accelerated degradation test plans considering adoption of tightened critical values. Under arandom coefficient degradation rate and log-linear acceleration models, the asymptotic variance of an estimatorfor a lifetime quantile at the use condition as the optimization criterion is derived where the degradation ratefollows a lognormal and Reciprocal Weibull distributions, respectively and then the low stress level andproportions ofunits allocated to each stress level are determined. We also show that the developed test plans canbe applied to the multiplicative model with measurement error.